ZU-Series, Electric Pumps



Similar documents
ZU4-Series, Portable Electric Pumps

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Cat Electronic Technician 2015C v1.0 Product Status Report 2/20/2016 4:34 PM

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

HYDROSTATIC TEST PUMPS

Centro-Matic Automatic Lubrication Systems System Controls

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Hydraulic Control Solutions

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

HPU14M-DS 2013 Daniels Manufacturing Corp., All Rights Reserved Page 1 of 17 REV. C 7/2013

Rexroth Hydraulic Pump A10VO Series User Manual

Magnum Mobile Generator MMG55 Specifications

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Hydraulic Flow Control Valves

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance

ETZGAR CONVEYOR COMPANY Controls Section v12.05

AIR OPERATED OIL PUMPS AND KITS

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Model 1210C Battery Powered Pump Shown. Description

Mini Hydraulic Excavator

The Secret of Hydraulic Schematics. BTPHydraulics

Electronic Pressure Switch EDS 3000

301.7D. Mini Hydraulic Excavator

Example. Fluid Power. Circuits

PRODUCT RELEASE CKMTA12 / 24. Copyright 2011 by ARB Corporation Limited

Electric Flow Boiler

PART 2 FORKLIFT HYDRAULIC SYSTEM

Desiccant Air Dryers Heatless, Heated and Heated Blower

Designed for multi-injector endurance testing, the

The Professional Choice. LDC With DC motor. OLAER LDC optimized for mobile use

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

KNC Model 3666 Automatic Pressure Calibration System

A U T O M O T I V E L I F T S

SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24

GROENEVELD AUTOMATIC GREASING SYSTEMS

Medical Air Systems: Scroll

USER S MANUAL HSC-24A

MovinCool Office Pro Series. The Portable Spot Cooling Solution

Goulds Water Technology

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

Chapter 7 Hydraulic System Troubleshooting

Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

MIT510/2, MIT520/2 and MIT1020/2

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

THE SIMPLEX HAND PUMP

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Dehumidifier Users manual. For Models: DH45S DH65S

Phone: Fax: Web: info@clrwtr.com

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

TITAN HYDRAULIC TORQUE WRENCHES

Diesel Engine Driven Generators Page 1 of 6

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

PC1131 Electric Air Compressor

Concrete Stressing Products. A complete solution designed for the challenging demands of concrete stressing

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

NAVIEN AMERICA INC FITCH AVENUE

NITROUS TRANSFER PUMP INSTRUCTIONS

ELLIOTT COLLET STYLE Baffle Expander With Hydraulic Power Supply

SunMaxx Solar Filling Station Operating Instructions

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

Troubleshooting Salt Generators

Hydraulic Troubleshooting PRESENTED BY

» 30,000 to 60,000 lb. capacity» Single and tandem axle

SMR Series Submicronic Removal Fluid Purifi cation Systems

Druck PV 62x pneumatic/hydraulic pressure stations

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments

Pressure Relief and Regulating Valves

Quiz On Information Learned From Chapter 1

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

ACCUMULATOR INSTALLATION

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

PC1130 Electric Air Compressor

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

400B SERIES DIAPHRAGM PUMP

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

Standard Hydraulic Piping Flushing Procedure

WHOLESALE DIRECT INC WEST 65TH STREET

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Unit 24: Applications of Pneumatics and Hydraulics

Brownie s. Tankfill. and. NitroxMakers

CSD WATER REMOVAL FILTERS FOR DIESEL

WIRE ROPE CUTTERS. Designed for new and unused wire rope. Since 1928

Pipe Cutting and Beveling Clamshells

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

P900 SERIES PORTABLE HYDROSTATIC TESTER

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

PRODUCT PROFILE FEATURES

Oil and Coolant Circulating Heating System. Model - OCSM

Transcription:

ZU-Series, Electric Pumps Shown from left to right: ZU4304MB, ZU4420SB-H, ZU4304PB-K eatures Z-Class high-efficiency pump design; higher oil flow and bypass pressure, cooler running and requires 18% less current draw than comparable pumps Powerful 1.7 hp universal electric motor provides high power-to-weight ratio and excellent low-voltage operating characteristics High-strength, molded composite shroud protects motor and electronics, while providing an ergonomic, non-conductive handle for easy transport Low-voltage pendant provides additional safety for the operator (remote control units) Pro Series pump only LCD readout provides pressure and torque display and a number of diagnostic and readout capabilities never before offered on a portable electric pump AutoCycle feature provides continuous cycle operation of the torque wrench as long as the advance button is pressed (pump can be used with or without auto cycle feature) COMMON PUMP MODELS or technical information and other options see next page. BASIC PUMP TYPES Select the model that suits your application. or special requirements contact your Enerpac office. Valve Ideal choice for most applications valve control, for single-acting or double-acting applications Motor control on shroud Valve with Pendant or light production and lifting applications valve control for single-acting or double-acting cylinders Low-voltage control pendant with 10-ft. cord for remote motor operation Dump Valve Ideal for punching, crimping and cutting or use when load-holding is not required Low-voltage control pendant with 10-ft. cord controls valve and motor Designed to be tough, the ZU4-Series with steel reservoirs will take the abuse of today s construction sites.the ZU4908JE is the ideal pump for post tensioning applications. or post tensioning tools see page 180. Solenoid Valve Ideal for lifting applications and where remote control is required Motor runs continuously on pumps with VE33 and VE43 valves. With VE32 valve, motor only runs during the advance function, while holding and retracting, the motor is off Low-voltage control pendant with 10 ft. cord for remote motor and valve operation 78 www.enerpac.com

ZU-Series, Electric Pumps Z-Class A Pump or Every Application Patented Z-Class pump technology provides high by-pass pressures for increased productivity important in applications using long hose runs and high pressure-drop circuits, like heavy lifting or certain double-acting tools. Enerpac ZU4 Hydraulic Pumps are built to power small to large-sized cylinders or hydraulic tools, or wherever highspeed, intermittent duty, remote hydraulic power is needed. Classic Electric Pump The Classic has traditional electro-mechanical components (transformers, relays and switches) in place of solid-state electronics. The Classic delivers durable, safe and efficient hydraulic power for demanding markets like construction, post-tensioning and foundation repair. Standard Electric Pump or applications that do not require digital display features of the Premium Pump. Available in all manual or jog versions. Pro Electric Pump Digital (LCD) display features a built-in hour meter and shows selfdiagnostic, cycle-count and low voltage warning information. Pressure can also be displayed when the pump is equipped with an optional pressure transducer. ZU Series Reservoir Capacity: -10.0 gal. low at Rated Pressure: 60 in 3 /min. Motor Size: 1.7 hp Operating Pressure: 10,000 psi Pump Type Used with Valve unction Valve Pump Control Usable Oil Cylinder Type 2) Capacity VM33 VM33 VM33 VE32D VE32D VE32D VE32 VE32 VE33 VE43 VE43 (Man.) (Man.) (Man.) (Man.) (Man.) (Man.) (gal) ZU4704RB ZU4708RB ZU4308RB ZU4320RB ZU4408RB ZU4420RB ZU4704PB ZU4708PB ZU4720PB ZU4308PB ZU4408PB ZU4420PB Model Number 115 VAC 3) 1 Phase Classic STD Electric Pro Electric ZU4704MB ZU4708MB ZU4308MB ZU4320MB ZU4408MB ZU4420MB ZU4204JB ZU4208JB ZU4220JB ZU4308JB ZU4408JB ZU4420JB All models meet CE safety requirements. E voltage versions also meet all requirements of the European EMC-Directive. 2) See valves section for technical information on valve types. 3) See custom order matrix for other voltage options. 4) Subtract 3 lbs. for STD Electric models. ZU4704LB ZU4708LB ZU4308LB ZU4320LB ZU4408LB ZU4420LB ZU4204KB ZU4208KB ZU4220KB ZU4308KB ZU4408KB ZU4420KB ZU4104DB ZU4108DB ZU4120DB ZU4204SB ZU4208SB ZU4308SB ZU4408SB ZU4420SB Pro Product Weight with oil 4) (lbs) 59 69 70 109 70 109 60 70 109 71 71 110 63 73 112 63 73 85 85 124 79

ZU Series, Specifications and Dimensions Motor Size (hp) Output low Rate (in 3 /min) 100 psi 700 psi 5000 psi 10,000 psi 1.7 700 535 76 60 ZU4 Performance Motor Electrical Specification ZU-4 Series with 1 and 2 gallon reservoirs (volts-ph-hz) 115-1-50/60 230-1-50/60 Sound Level (dba) Relief Valve Adjustment Range 85-90 2,000-10,000 12.50 Oil flow (in 3 /min) Oil low and Current vs. Pressure 700 25 600 500 400 300 200 100 115V 230V 20 15 10 5 Current (amps) 20.50 2.50 A 0 0 0 2000 4000 6000 8000 10,000 Pressure low (in 3 /min) Current (amps) 9.00 C 16.30 23.40 19.00 20 ZU-4 Series with 2.5, and 10.0 gallon reservoirs (Left view shown without side handle).50 B 3.75 D.25 19.40 20 9.45 10.50 A 1.30 C 17.60 24.00 B D E 4XØ.34 10 18.10.51 1 User adjustable relief valve 2 Oil fill port, SAE#10 3 Oil level sight gauge 4 Oil Drain, 1/2" NPT 5 M8 x 1.25 6 Handles on all 2.5,, and 10.0 gallon reservoirs actory installed features and options 7 Back-lit LCD Electric 8 Pressure transducer 9 Heat exchanger 10 Skid bar 11 Handle guard installed on all 2.5, 5, and 10 gallon reservoirs 12 Reservoir handles included on all 2.5, 5 and 10 gallon pumps Increased output flow and extended brush life increase productivity for posttensioning applications. Usable Reservoir Capacity (gal) 2.5 10.0 Pump Dimensions (in) A B C D E 16.7 5.6 1 6.0 - - 16.7 5.6 1 8.1 - - 17.3 6.2 16.5 1 15.1 1 18.3 7.1 16.5 16.6 19.7 15.6 21.7 10.6 15.7 19.9 22.7 18.9 80 www.enerpac.com

ZU-Series, Ordering Matrix CUSTOM BUILD YOUR ZU4 SERIES PUMP If the ZU4 Series pump that would best fit your application cannot be found in the chart on page 79, you can easily build your custom ZU4 Series pump here. This is how a ZU-Series pump model number is built up: Z U 4 4 08 L B - H K T 1 Product Type 2 Motor Type 3 low roup 1 Product Type Z = Pump Series 4 Valve Type 2 Motor Type U = Universal electric motor 3 low roup 4 = 60 in 3 /min @ 10,000 psi 5 Reservoir 6 Valve 7 Voltage Size Operation 4 Valve Type (see page 110 for more details) 1 Dump (VE32D) 2 3 way/2 position manual or electric (VM32 or VE32) 3 3 way/3 position manual or electric (VM33 or VE33) 4 4 way/3 position manual or electric ( or VE43) 6 3 way/3 position locking manual w/po check (VM33-L) 7 3 way/2 position manual () 8 4 way/3 position locking manual w/po check (-L) 9 4 way/3 position manual w/power seating (-LPS) 5 Reservoir Size (useable capacity) 04 = gallon 08 = gallon 10 = 2.5 gallon (includes side handles) 20 = gallon (includes side handles) 40 = 10.0 gallon (includes side handles) 6 Valve Operation D = Dump (solenoid valve w/pendant and LCD Electric) J = Jog (manual valve w/pendant and Standard Electric (i.e. w/o LCD) K = Jog (manual valve w/pendant and LCD Electric) L = valve w/lcd Electric (w/o pendant) P = valve w/pendant and classic electric (i.e.w/o LCD) R = valve w/classic electric (i.e. w/o LCD) [w/o pendant] M = valve w/standard Electric (i.e. w/o LCD) [w/o pendant] S = Solenoid valve w/pendant and LCD Electric 7 Voltage B = 115V, 1 ph, 50/60Hz E = 208-240V, 1 ph, 50/60 Hz (w/european plug and CE EMC compliant) I = 208-240V, 1 ph, 50/60 Hz (w/nema 6-15 plug) 8 Options and Accessories (see page 82 for possibilities) = ilter = 0-15,000 psi gauge (2 1/2") H = Heat exchanger K = Skidbar (1 and 2 gallon reservoirs only) L = Level/temp switch 2) 3) N = No reservoir handles (includes lifting eyes) R = Roll cage T = Pressure transducer 2) U = oot switch 8 Options and Accessories ZU Series Reservoir Capacity: -10.0 gal. low at Rated Pressure: 60 in 3 /min. Motor Size: 1.7 hp Operating Pressure: 10,000 psi Speed Chart To determine how a "Z" pump will operate your cylinder, see the Pump/Cylinder Speed Chart in the Yellow Pages. 251 Ordering Example Model Number: ZU4408LB-HKT ZU4408LB-HKT is a 60 in 3 /min at 10,000 psi pump with a 4-way, 3-position manual valve, a 2 gal. (8-liter) reservoir, operates on 115V, 1ph, 50/60 Hz and is specified with optional LCD electrical panel, heat exchanger, pressure transducer and skidbar. Torque Wrench Pumps System matched air and electric pumps provide control to operate Enerpac Torque Wrenches. 204 Pressure gauge not available on pump models with pressure transducer 2) These options require LCD electric 3) Not available on 1 and 2 gallon reservoirs 81

ZU-Series actory Installed Options & Accessories Hoses Enerpac offers a complete line of high-quality hydraulic hoses. To ensure the integrity of your system, specify only Enerpac hydraulic hoses. 114 Pressure Transducer* More durable than analog gauges (against mechanical and hydraulic shock) More accurate than analog gauges (0.5% full scale of pump) Calibration can be fine tuned for certification Set pressure feature turns off motor at user defined pressure (or shifts valve to neutral on models with VE33/ VE43 valves) Display pressure in psi, bar, or MPa * Requires LCD Electric Level/Temperature Switch Ensures feedback on pump oil level and temperature Drop-in design allows for easy installation to pump reservoir Plugs directly into pump electrical enclosure Built-in thermal sensing shuts off pump when unsafe operating temperature is reached Oil level switch shuts down pump before oil reaches an unsafe operating level auges Minimize the risk of over loading and ensure long, dependable service from your equipment. Refer to the System Components section for a full range of gauges. 113 Kit Model Number Adjustable Pressure Range Switchpoint repeatability Deadband Model Number Operating Temperature ( ) Pressure Weight ZPT-U4 * 50-10,000 ± 0,5% 50 ZLS-U4 40-230 150.11 * Add suffix T for factory installation. * Add suffix L for factory installation. (lbs) oot Switch Hands-free remote control on solenoid dump and 3-position valves With 10 foot cord Kit No. Can be used on ZU4 Pumps with ZC-2 * Solenoid VE-Series valves * Add suffix U for factory installation. Roll Cage Protects pump Provides greater pump stability Kit Number its on Reservoir ZRC-04 * 1 and 2 gallon ZRC-04H * 1 and 2 gallon 2) ZRB-10 * 2.5 gallon ZRB-20 * 5 gallon ZRB-40 * 10 gallon * Add suffix R for factory installation. 2) Without heat exchanger With heat exchanger Ordering Example: Model No. ZU4208BB-QR Skidbar* Provides easy two-hand lift Provides greater pump stability on soft or uneven surfaces Also available as an add-on kit (model number SBZ-4) * 1 and 2 gallon reservoirs only or ZU-Series Pumps Wt. Kit No. with Reservoir (lbs) SBZ-4 * 1-2 gal. w/o heat exchanger SBZ-4L * 1-2 gal. with heat exchanger * Add suffix K for factory installation. 4.9 5.5 82 www.enerpac.com

ZU-Series actory Installed Options and Accessories ZU4-Series Options Kits can be installed by the customer. See chart below for all possible options on ZU4-Series pumps: Classic Electric, Standard (STD) Electric (no LCD) Pro Electric (with LCD). Refer to page 81 for ordering matrix. ZU Series ZU4-Series Options actory Installed Classic Standard Pro Electric Electric Electric Return Line ilter Skid Bar Roll Cage Heat Exchanger Pressure auge Pressure Transducer Level/Temperature Switch oot Switch K R H K R H K R H T L U Skid Bar not in combination with Roll Cage. Classic Electric ZP SBZ ZRC ZHE Kits Standard Electric ZP SBZ ZRC ZHE Pro Electric ZP SBZ ZRC ZHE ZPT-U4 ZLS-U4 ZC-2 Reservoir Capacity: -10.0 gal. low at Rated Pressure: 60 in 3 /min. Motor Size: 1.7 hp Operating Pressure: 10,000 psi Heat Exchanger Extends system life Stabilizes oil temperature at a maximum of 130 at 70 ambient temperature. Do not exceed maximum oil flow and pressure ratings. Heat exchanger is not suitable for water-glycol or high water based fluids. Return Line ilter 25 micron nominal filter removes contaminants from return oil flow before allowing it back into tank Internal by-pass valve prevents damage if filter is dirty With maintenance indicator Heat Exchanger Removes heat from the bypass oil to provide cooler operation Stabilizes oil viscosity, increasing oil life and reduces wear of pump and other hydraulic components Thermal Transfer * pressure oil flow Voltage Kit Model Number Pressure Oil low By-pass Setting Kit No. * Can be used on ZP * 200 (PM) 1 25 ZHE-U115 ZHE-U230 115V pumps 230V pumps * Add suffix for factory installation. * Add suffix H for factory installation. Btu/h (PM) (VDC) 900 900 7.0 12 * At PM at 70 ambient temperature. 83