MSA Air-Line Respirators



Similar documents
Parts List: AirHawk II Air Mask

3M Air-Mate Self-Contained Breathing Apparatus (SCBA)

NITROUS TRANSFER PUMP INSTRUCTIONS

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

AUTOMATIC CHANGEOVER MANIFOLD Series 915

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Elgin Fire Department

QuickAir - 5, - 10 Minute Emergency Escape Breathing Apparatus. Operating Manual

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

SCBA Frequently Asked Questions

Brookings Fire Dept. SCBA Specifications

Hose Clamps & Fittings

Automated Test System SIMPLICITY COUNTS MSA s New GALAXY GX2 Automated Test System / Advanced Safety Management Effortless Operation

3Portable Compressed Air Filter and Regulator Panel , with Carbon Monoxide Filtration and Monitor

Temperature Adaptor. Vacuum Tree

KNC Model 3666 Automatic Pressure Calibration System

Continuous-Flow Supplied Air Respirator

SCOTT E-Z AIRLINE PRESSURE DEMAND TYPE C SUPPLIED AIR RESPIRATOR FOR USE WITH A SCOTT FULL FACEPIECE AIR INLET HOSE TO BREATHING REGULATOR

NIOSH approval labels key information to protect yourself By R. Metzler and J. Szalajda

tire inflator with pressure gauge

Self-Contained Breathing Apparatus (SCBA)

Ultrasonic Gas Leak Detection

System Accessories Pricing. Page 0 Effective 7/02

PA94 Plus Basic. System Overview. Accessories/Options. PA94 Plus Basic Quick Release LDV Coupling PA94 Plus Basic Fixed LDV

Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.

Hose & Coupling Solutions Dixon Europe

Complete Systems & Parts Automatic Oiler & Grease Bank

SIMPLAIR PIPING TOOL

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

Micro GC Fusion Pre-Installation Checklist

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

with installation dynafact boost GAUGE this manual is for use with systems

7500 Series. Important: Keep these user instructions for reference.

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

MODEL G300 BRAKE BLEEDER

CHEMICAL CLEANING UNIT Product number:

CHIPPING HAMMERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

High Pressure Equipment High Pressure Valves, Fittings and Tubing

Custom 4500 MMR and Ultralite MMR Air Masks Including Dual-Purpose Options, Quick-Fill Options and Accessories DESCRIPTION FEATURES

FIRE SERVICE CATALOG. Technology That Saves Lives

L /96. Haldex INSTALLATION INSTRUCTIONS HALDEX PURE AIR PLUS EXTENDED PURGE KIT (DQ6027) HEAVY DUTY CANISTER KIT (DQ6028)

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

Single Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Model 111 Mass Flow Instruments

MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

VAG 1687 Diagnostic Tool, Checking Intake System for Leaks. Condition. Service 00-A A353

RESPIRATORY PROTECTION SCBA, ESCAPE & AIRLINE

AMX300 DirectConnect Mixing Valve Kits

AIR LINE VALVES AND GAUGES

Fisher 377 Trip Valve

Personal Protection Equipment for Mold Remediation

RIVET BUSTERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

HEAD HARNESS & BUCKELS

Newloc Acetal. Plastic Push-to-Connect Fittings. Fluid Transfer Specialists

Occupational Health and Safety. Bulletin. Respiratory Protective Equipment: An Employer s Guide

All Safe, Inc. Sherwood Master Distributor Toll Free: Fax:

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

If you regularly wear a respirator on the job, OSHA requires your employer to provide:

PRODUCT RELEASE CKMTA12 / 24. Copyright 2011 by ARB Corporation Limited

Cajon VCR Fittings. Flanges, Fittings, & Components. Cajon & Swagelok Fittings. Cajon VCR Fittings. Nuts, Caps, & Plugs. Socket Weld Glands

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Dräger PSS 3000 Self Contained Breathing Apparatus

Used Fluid Handling Portable Used-Oil Gravity Drains

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

1998½-2007 Dodge Ram 5.9L Cummins

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions

INSTALLATION INSTRUCTIONS

Your safety and the safety of others are very important.

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

INSTALLATION AND OPERATION INSTRUCTIONS NOT FOR OXYGEN OR OTHER OXIDIZING GASES

Self-Contained Breathing Apparatus (SCBA) Program and Procedures for SCOTT AIR-PAK 75i

Many Products...One Source

HAND PUMP OPERATION, SERVICE AND PARTS INSTRUCTION MANUAL

Regulator Options and Accessories

Respiratory Protection in the Workplace. A Practical Guide for Small-Business Employers

General Purpose ph/orp Sensors

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

YELLOW JACKET Hose Adapters, Valves, and Parts right to the last detail

SAFETY SAFETY APPAREL 20,000 PSI

OSHA and Welding Exhaust

PARTS LIST T30 MODEL 2545 TWO STAGE INDUSTRIAL AIR COMPRESSOR

Escape Device Range. For a Safe Escape

TYPE E Main Valve Sizes 3 /8 through 12

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Dräger PSS 7000 SCBA Self-Contained Breathing Apparatus

Meritor Tire Inflation System (MTIS) by PSI

Your Portable Oxygen System. Use & Care Guide

The University will meet or exceed the legislated requirements made under the Alberta Occupational Health and Safety Act, Regulation and Code.

needle valves Needle Valves Index At a Glance 1

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION

Fisher 2625, 2625SST, and 2625NS Volume Boosters

cherne industries inc.

PNEUMATIC PLANISHING HAMMER

8D.1 BALL ANGLE METER VALVES - 3/4" & 1" P B E B B B-24267

Transcription:

MSA Air-Line Respirators Key Products Because every life has a purpose...

MSA Air-Line Systems Type C Supplied-Air Respirators, commonly called air-line respirators, provide long-duration respiratory protection. Systems generally consist of a full- or half-mask facepiece connected by air-supply hose to an air source. When connected, respirators deliver respirable air to users. This guide is designed to aid in understanding specific pressure-demand and constant flow air-line systems from air source to respirator. Complete air-line kits consisting of frequently-ordered systems for ease of ordering are listed as well. Type C Supplied-Air Respirators are approved by the National Institute for Occupational Safety and Health (NIOSH) for use in atmospheres not immediately dangerous to life and health (IDLH), or from which users can escape without wearing respirators, unless respirators are equipped with escape air cylinders. Not immediately dangerous to life and health means any hazardous atmosphere that may produce physical discomfort immediately, chronic poisoning after repeated exposure or acute adverse physiological symptoms after prolonged exposure. (42 CFR, Part 84 subpart A, 84.2(x)). Pressure-Demand vs. Constant Flow Respirators These systems differ in how supplied air is delivered to users. Pressure-demand systems deliver air to the respirator facepiece only as users require it; thus, pressure-demand devices afford greater breathing efficiency. Constant flow systems provide continuous air flow to the respirator facepiece and are generally used only with compressors for virtually unlimited air supply. Pressure-Demand Air-line Respirators: Maintain slight positive facepiece air pressure, helping to prevent contaminant entry. Require air supply from uncontaminated compressed-air sources conforming to at least Grade D of ANSI Standard Z86.1. Typically use large compressed air cylinders singly or cylinder cascade systems consisting of several air cylinders connected in a bank via pigtails. Constant Flow Air-line Respirators: Maintain slight positive facepiece air pressure, helping to prevent contaminant entry. Require air supply from uncontaminated compressed-air sources conforming to at least Grade D of ANSI Standard Z86.1. Maintain air flow at all times, rather than only on demand. Typically use compressors as their air source, as constant flow systems quickly exhaust air from compressed air cylinders. Are offered in two styles, tight-fitting facepiece or loose-fitting hood/helmet.

MSA Pressure-Demand Respirators PremAire Cadet Respirator PremAire Cadet Respirator pressure-demand, Type-C, NIOSH-approved, supplied-air respirator with mask-mounted regulator responds quickly to wearers changing breathing requirements. Key applications include chemical, industrial, metals, power generation, water and wastewater treatment, public works, maintenance, and food processing. Basic air-supplied device is easily upgradeable to versatile PremAire System. May be used in non-idlh (Immediately Dangerous to Life or Health) environments only. Complete Assemblies All listed configurations include Ultra Elite (medium size, Hycar Rubber, rubber head harness) or Advantage 4000 (medium size, Hycar Rubber, net head harness) with Push-To-Connect Firehawk MMR and nylon belt assembly. Hose Fittings Ultra Elite Advantage 4000 30" IP (intermediate pressure) None 10054790 10081100 30" IP (intermediate pressure) Snap-Tite AL 10054793 10081098 42" IP (intermediate pressure) None 10054791 10081171 42" IP (intermediate pressure) Snap-Tite AL 10054792 10081099 Note: see page 8 to order quick-disconnects for use with PremAire and PremAire Cadet Systems (column 2 for plug and column 5 for socket assembly). PremAire Cadet Kits PremAire Cadet Respirator Kits include PremAire Cadet Respirator with Advantage 4000 (medium size, Hycar Rubber, polyester net head harness) with Push-To-Connect Firehawk MMR, nylon belt assembly, listed quick-disconnect for connecting respirator to air-supply hose, neoprene airsupply hose 50-ft section complete with corresponding plug to attach air-supply hose to air source. 3 Description Part Number PremAire Cadet Air-line Respirator with Foster steel quick-disconnects, neoprene air-supply hose 50-ft section with Foster steel plug PremAire Cadet Air-line Respirator with Snap-Tite aluminum quickdisconnects, neoprene air-supply hose 50-ft section with Snap-Tite aluminum steel plug 10108493 10108594 PremAire Cadet Air-Line Respirator with TransportAire Portable Air-Supply Assembly Description Part Number Low-pressure configuration Kit includes PremAire Cadet Respirator with Advantage 4000 (medium size, Hycar Rubber, polyester net head harness) with Push-To- Connect Firehawk MMR and nylon belt assembly, Snap-Tite quick-disconnect and low pressure TransportAire Portable Air Supply with 30-minute carbon fiber cylinder, and 8-ft coiled nylon air-supply hose. 10108495

Air-Line Respirators MSA Pressure-Demand Respirators PremAire Cadet Escape Respirator The PremAire Cadet Escape Respirator, Combination Supplied-Air Respirator with Escape Cylinder offers streamlined design for size, simplicity, comfort, and economy. Key applications include chemical, refinery, oil and gas drilling, maintenance, confined space entry, turnarounds, storage facilities, public works, and food processing. Low-profile escape cylinders may be worn on right or left hip. Choice of Ultra Elite Pressure-Demand or Advantage 4000 with APR conversion capability. Firehawk MMR Regulator offers choice of Push-To-Connect (PTC) or Slide-To-Connect (STC) attachments. Harness Cylinder Disconnect Part Number VALUE MODELS Nylon strap carrier Advantage 4000, Medium, Hycar Rubber, rubber head harness 5-minute aluminum Hansen 10092031 Nylon strap carrier Advantage 4000, Medium, Hycar Rubber, rubber head harness 5-minute aluminum Snap-Tite 10092033 Nylon strap carrier Advantage 4000, Medium, Hycar Rubber, net head harness 5-minute aluminum Hansen 10092034 Nylon strap carrier Advantage 4000, Medium, Hycar Rubber, net head harness 10-minute aluminum Snap-Tite 10092035 Nylon strap carrier Advantage 4000, Medium, Hycar Rubber, net head harness 10-minute aluminum Hansen 10092036 Nylon strap carrier Advantage 4000, Medium, Hycar Rubber, net head harness 15-minute carbon Snap-Tite 10092037 Nylon strap carrier Advantage 4000, Medium, Hycar Rubber, net head harness 15-minute carbon Hansen 10092038 The PremAire Cadet Escape is available in other configurations; for further information; please see bulletin 0103-12 or the MSA Safety Equipment catalog. PremAire Cadet Escape Kits PremAire Cadet Escape Respirator Kits include PremAire Cadet Escape Respirator with Advantage 4000 (medium size, Hycar Rubber, polyester net head harness) with Push-To-Connect Firehawk MMR and nylon harness, aluminum cylinder, and listed quick-disconnect for connecting respirator to air-supply hose, neoprene air-supply hose 50-ft section complete with corresponding plug to attach air-supply hose to air source. Description Part Number PremAire Cadet Escape Air-line Respirator, 5-minute aluminum egress cylinder, Hansen brass quick-disconnects, 50-ft section of neoprene air-supply hose with Hansen brass plug. PremAire Cadet Escape Air-Line Respirator, 10-minute aluminum egress cylinder, Hansen brass quick-disconnects, 50-ft section of neoprene air-supply hose with Hansen brass plug. 10108496 10108592 Additional MSA PremAire Air-Line Respirator Systems: Dual-supply (to eliminate additional hose lengths)

Pressure-Demand System Optional locking quick-disconnects Sealing tape required on all pipe threads. Begin at second thread and wrap 1 to 1½ turns clockwise. * 2400 psig cascade system Select 1 outlet connection: E1, E2 or E3 Note: DO NOT use teflon sealing tape on straight threaded connections with O-ring seals. Note: Cascade cylinders are not normally used with constant flow systems due to excessive air usage 1 large (300- cu-ft) cylinder would last 1 working person only about 15 minutes. Therefore, using cascade cylinders with pressure-demand systems is recommended. OUTLET CONNECTIONS: E1 Pressure Demand System 1* Air cylinder NOT SUPPLIED BY MSA A Air tee block P/N 68850 or P/N 10081206 (see page 8) B Air pigtail P/N 68851 or P/N 10081205 (see page 8) C Audi-Larm Audible Alarm warning device P/N 85078 or P/N 492307 (see page 8) D Air-cylinder pressure regulator P/N 68858 or P/N 633352 (see page 8) E2 E3 Female socket P/N varies with type (see page 8) Nipple W" x W" NPT (needed only w/female socket) P/N 459867 2-outlet manifold: Foster steel P/N 84416 Snap-Tite aluminum P/N 486053 (see page 8) 4-outlet manifold: Foster steel P/N 47370 Snap-Tite aluminum P/N 93931 (see page 8) F Male plug with female W" NPT P/N varies with type (see page 8) G Union adapter (see page 8) H MSA air-supply hose P/N varies with type (see page 8) A Pocket Guide to Air-Line Systems This pocket-size booklet illustrates complete hookups of various MSA air-line systems, both constant flow and pressure-demand, from air source to respirator connection. Below each illustration, individual system parts are identified by title and part number. Readers are then referred to following pages for more information concerning specific MSA components. Visit to download your copy of A Pocket Guide to Air-Line Systems, bulletin 0114-14-MC. 5 I Optional locking quick-disconnect assemblies for interconnecting lengths of MSA air-supply hose CEJN locking quick-disconnect assembly (chrome) P/N 479009 Snap-Tite locking quick-disconnect assembly (aluminum) P/N 479010 J Female socket assembly P/N varies with type (see page 8)

Air-Line Respirators MSA Constant Flow Respirators Complete respirator assemblies are available with Advantage 4000, Ultravue or Ultra Elite Full-s, Comfo Half-Mask or Comfo Welder s, breathing tube, web support belt, and air-flow control valve with quick-disconnect assembly. Key applications include chemical, industrial, metals, power generation, maintenance, and pharmaceutical. NIOSH-approved. with Advantage 4000 Complete Assemblies with Ultra Elite with Ultravue with Comfo Choose facepiece, control valve and quick-disconnect assembly. Includes breathing tube and web support belt. with Welder s Comfo Quick-Disconnect Kits Advantage 4000 Ultra Elite Ultravue Comfo Welder s Comfo HIGH PRESSURE CONTROL VALVE (35-40 PSIG INLET PRESSURE FOR 8-300-FT OF HOSE) Snap-Tite aluminum 10088132 810829 460863 460865 460862 Foster steel 10088134 810831 461717 480466 480600 Hansen brass 10088136 486258 CEJN locking chrome-plated brass 10088135 810832 480629 480631 480671 LOW PRESSURE CONTROL VALVE (10-15 PSIG INLET PRESSURE FOR 8-50-FT OF HOSE) Snap-Tite aluminum 10088107 806775 463300 463302 463281 Foster steel 10088109 806776 480472 480474 480468 Hansen brass 10088121 806779 484836 484837 CEJN locking chrome-plated brass 10088110 806777 480637 480639 480645 Note: facepieces can also be ordered in silicone instead of Hycar Rubber. Three facepiece sizes are available. For belts, MSA air-supply hose and other accessories, see page 8. For separate quick-disconnect plugs and sockets, see page 8. See page 7 for typical constant flow air-line systems setup. Available by special order only. High pressure control valves are available with these special order quick-disconnects: Snap-Tite brass or stainless steel, Foster brass, Hansen brass, or stainless steel. Low pressure control valves are also available with Snap-Tite brass or stainless steel, Foster brass, and Hansen brass. Please contact your nearest MSA distributor for complete ordering information. Kits include constant flow air-line respirator with Advantage 4000 (medium size, Hycar Rubber, polyester net head harness) with high or low pressure flow control valve, breathing tube and nylon belt assembly, listed quick-disconnect for connecting respirator to air-supply hose, 50-ft neoprene air-supply hose section complete with corresponding plug to attach air-supply hose to air source. Description Part Number Constant flow air-line respirator, low pressure control valve, Foster steel quick-disconnects, 50-ft section neoprene air-supply hose with 10108494 Foster steel plug. Constant flow air-line respirator, high pressure control valve, Foster steel quick-disconnects, 50-ft section neoprene air-supply hose with 10108593 Foster steel plug.

Constant Flow Air-Line Kits Additional MSA constant flow respirators with loose-fitting hoods include Versa-Hood Air-Supplied Hood P\N 484690, Versa-Hood with Foster plug. Additional MSA constant flow respirators with tight-fitting facepieces include: Constant Flow Duo-Twin Air-Line Respirator, complete with Foster plug and socket - P/N 484087. Constant Flow Duo-Flo Air-Line Respirator, complete with Advantage 4000 - P/N 10091952. Abrasi-Blast Supplied-Air Respirator, models with waist-length Hypalon hood. - High pressure - P/N 468718 - Abrasi-Blast Respirator with Duo-Flo Respirator - P/N 478116 Constant Flow System REGULATED PLANT AIR COMPRESSOR Optional locking quick-disconnects Select 1 outlet connection: G1, G2 or G3 Constant-Flow System 1* Plant air compressor NOT SUPPLIED BY MSA A Outlet fitting for system varies with system 7 B Nipple (1/2 x 1/2 x 1 1/2 NPT) P/N 68833 C Air-line filter P/N 81857 E Pressure regulator P/N 66716 OUTLET CONNECTIONS: F G1 G2 Bushing (1/2" M x 1/4" F) P/N 625528 Female socket P/N varies with type (see page 6 column 1) Nipple 1/4" x 1/4" NPT (needed only w/female socket) P/N 459867 2-outlet manifold: Foster steel P/N 84416 Snap-Tite aluminum P/N 486053 (see page 8) H Male plug with male 1/4" NPT (see page 8 column 4) I Union adapter (see page 8 column 3) J MSA air-supply hose P/N varies with type (see page 8) K Optional locking quick-disconnect assemblies for interconnecting lengths of MSA air-supply hose CEJN locking quick-disconnect assembly (chrome) P/N 479009 Snap-Tite locking quick-disconnect assembly (aluminum) P/N 479010 L Female socket assembly P/N varies with type (see page 8 column 5)

MSA Air-Line Fittings, Hoses, Cascade Systems, and Accessories For complete listings of MSA air-line respirators, air sources, accessories, and system configurations, please see A Pocket Guide to Air-Line Systems, MSA bulletin #0114-14. Cascade System Accessories Audi-Larm Audible Alarm, low pressure CGA 346, 0-3000 psig 85078 Audi-Larm Audible Alarm, high pressure CGA 347, 0-5500 psig 492307 Air coupler tee - low pressure CGA 346, 0-3000 psig 68850 Air coupler tee - high pressure CGA 347, 0-5500 psig 10081206 Air pigtail - low pressure CGA 346, 0-3000 psig 68851 Air pigtail - high pressure CGA 347, 0-5500 psig 10081205 Air cylinder pressure regulator, dual-gauge, 0-3000 psig 68858 High pressure air cylinder regulator, dual-gauge, 0-5500 psig 633352 2-outlet manifold with Foster quick-disconnects 84416 2-outlet manifold with Snap-Tite quick-disconnects 486053 4-outlet manifold with Foster quick-disconnects 47370 4-outlet manifold with Snap-Tite quick-disconnects 93931 Air-Supply Hose MATERIAL HOSE COUPLING 100FT 50FT 25FT 15FT 8FT Neoprene Brass 455022 455021 455020 481071 Neoprene Stainless steel 481080 481079 481078 481077 PVC Brass 484225 471513 471512 471511 481051 PVC Stainless steel 481060 481059 481058 481057 Coiled nylon Brass 474043* 491515* 491514* 491513* * Recommended usable length, 4-25-ft. 1 2 3 4 5* QUICK-DISCONNECT TYPE Interchangeability Female socket 1/4" NPT Male plug w/female 1/4" NPT Union adapter 1/4" NPT x 3/4" UNF Male plug w/male 1/4" NPT (used when connecting inlet pressure gauge) Fe male socket assy. (used to connect air-supply hose to male plug on respirator) SNAP-TITE (AL) C 66272 66274 69542 66273 455019 SNAP-TITE (SST) C 629673 629672 808358 629671 471778 SNAP-TITE (BR) C 630305 630307 69542 630306 471777 HANSEN (SST) A 628768 628208 808358 473502 471779 HANSEN (BR) D 630311 630313 69542 630312 471501 FOSTER (S) B 628770 55716 69542 56549 467044 FOSTER (SST) B 636459 636460 808358 801016 FOSTER (BR) A 629980 629981 69542 473501 470194 SCHRADER (S) B SEE FOSTER(S) SEE FOSTER(S) SEE FOSTER(S) SEE FOSTER(S) SEE FOSTER(S) CEJN LOCKING (CHROME-PLATED BR) E 631870 479026 69542 479020 479001 SNAP-TITE LOCKING (AL) F 479027 69542 479032 SNAP-TITE LOCKING (SST) F 479028 808358 479022 479033 SNAP-TITE LOCKING (BR) F 479029 69542 479023 479034 FOSTER LOCKING (SST) D 636473 637851 808358 800805 AL=aluminum, SST=stainless steel, S=steel, BR=brass Fittings with the same letter code are interchangeable. * Socket assembly consists of socket from column 1 and brass union adapter P/N 69541 (3/4'' female x 1/4'' npt male). Exception: all SST fittings have SST union P/N 808360. Note: This bulletin contains only a general description of the products shown. While uses and performance capabilities are described, under no circumstances shall the products be used by untrained or unqualified individuals and not until the product instructions including any warnings or cautions provided have been thoroughly read and understood. Only they contain the complete and detailed information concerning proper use and care of these products. ID 0100-02-MC / October 2012 MSA 2012 Printed in U.S.A. Corporate Center 1000 Cranberry Woods Drive, Cranberry Township, PA 16066 USA Phone 724-776-8600 U.S. Customer Service Center Phone 1-800-MSA-2222 Fax 1-800-967-0398 MSA Canada Phone 1-800-672-2222 Fax 1-800-967-0398 MSA Mexico Phone 01 800 672 7222 Fax 52-44 2227 3943 MSA International Phone 724-776-8626 Toll Free 1-800-672-7777 Fax 724-741-1559 Email msa.international@msasafety.com Offices and representatives worldwide For further information: