PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Similar documents
PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

UCI274C - Technical Data Sheet

UCI274H - Technical Data Sheet

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PM734F - Technical Data Sheet Winding 28

BCI184E - Technical Data Sheet

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

3790 en / d. Alternators LSA Pole. Electrical and mechanical data

IGSA POWER GENERATION SYSTEMS

STAMFORD Product Guide

CUKUROVA GENERATOR SYSTEMS

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Automatic Voltage Regulator User s Manual

SYNCHRONOUS MACHINES

Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

Lab 8: DC generators: shunt, series, and compounded.

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Physical Address: City: State: Zip Code:

CUKUROVA GENERATOR SYSTEMS

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

FIT TIER 2 Application

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

DIESEL GENERATOR SETS

Diesel Generator Set Model DFMB 60 Hz

Rules for Classification and Construction Additional Rules and Guidelines

AC-Synchronous Generator

CUMMINS SERIE 6B. Definiciónes. Potencia Prime. Potencia Stand by. Estos valores son aplicables para el suministro de energía eléctrica continua

Diesel Generator Set Model DFHC 60 Hz

Offshore Platform Powered With New Electrical Motor Drive System

Spark-ignited generator set

CUKUROVA GENERATOR SYSTEMS

FAULT FINDING MANUAL. For Stamford AC Generators

WIND TURBINE TECHNOLOGY

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

Generators TEM. for small hydroelectric power stations. Electric Machines

R448 & R448 V50 A.V.R.

Basics of Electricity

Welcome to Linear Controls Quarterly Training

The reliability of the grid

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

Paralleling Power Sources Which Share a Common Neutral

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

Power Quality Paper #3

3753 en /b VE/B - VE/RG Va V riable speed drives

Verification of Short Circuit Test Results of Salient Poles Synchronous Generator

Thyristor-controlled power supplies and battery chargers

Mounting Instructions. Torque Transducer. A en

C Standard AC Motors

Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting, excitation system

Diesel Generator Set Model DGDK 60 Hz

Diesel Engine Driven Generators Page 1 of 6

Application Information

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

How To Control A Power Command Powerplant

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

Diesel Generating Set

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

SX460. Generator Automatic Voltage Regulator Operation Manual

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

FREQUENCY CONTROLLED AC MOTOR DRIVE

FAULT FINDING MANUAL For Self Excited and Separately Excited Generators

Single-Phase AC Synchronous Generator

Torque motors. direct drive technology

How the efficiency of induction motor is measured?

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

Phase Modular Finally the benefits of Modular ups are for all

R438 A.V.R. Installation and maintenance R 438. This manual is to be given to. the end user T10. Armature 6- Field X2 Z1 X1 Z2 E+ E- 0V

Solving VFD-sourced Bearing Current Problems in AC Motors.

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Synchronous motor. Type. Non-excited motors

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

SAMPLE OF THE STUDY MATERIAL PART OF CHAPTER 3. Symmetrical Components & Faults Calculations

DIRECT CURRENT GENERATORS

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

Circulating Current Relay. Type IRXm

TABLE OF CONTENTS INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

A Single Source for all Power System Solutions

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

Transcription:

PI044E - Winding 311 Technical Data Sheet

PI044E SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-0, AS1359. Other standards and certifications can be considered on request. VOLTAGE REGULATOR AS480 AVR fitted as STANDARD TERMINALS & TERMINAL BOX Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted at the non-drive end of the generator. Dedicated single phase generators are also available. A sheet steel terminal box contains provides ample space for the customers' wiring and gland arrangements. Alternative terminal boxes are available for customers who want to fit additional components in the terminal box. SHAFT & KEYS With this self-excited system the main stator provides power via the AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by a surge suppressor against surges caused, for example, by short circuit or out-of-phase paralleling. The AS480 will support limited accessories, RFI suppession remote voltage trimmer and for the P1 range only a 'droop' Current Transformer (CT) to permit parallel operation with other ac generators. The AVR is can be fitted to either side of the generator in its own housing in the non-drive end bracket. Excitation Boost System (EBS) (OPTIONAL) The EBS is a single, self-contained unit, attached to the non-drive end of the generator. The EBS unit consists of the Excitation Boost Controller (EBC) and an Excitation Boost Generator (EBG). Under fault conditions, or when the generator is subjected to a large impact load such as a motor starting, the generator voltage will drop. The EBC senses the drop in voltage and engages the output power of the EBG. This additional power feeds the generator s excitation system, supporting the load until breaker discrimination can remove the fault or enable the generator to pick up a motor and drive the voltage recovery. WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion. All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. INSULATION / IMPREGNATION The insulation system is class 'H'. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 600-6-2:2001. At no time will the steady-state voltage regulation exceed 2%. DE RATES All values tabulated on page 9 are subject to the following reductions 5% when air inlet filters are fitted. 3% for every 500 metres by which the operating altitude exceeds 00 metres above mean sea level. 3% for every 5 C by which the operational ambient temperature exceeds 40 C. Note: Requirement for operating in an ambient exceeding 60 C must be referred to the factory. 5% For reverse rotation (Standard rotation CW when viewed from DE) NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing typical of product range. 2

PI044E WINDING 311 CONTROL SYSTEM VOLTAGE REGULATION SUSTAINED SHORT CIRCUIT CONTROL SYSTEM SUSTAINED SHORT CIRCUIT STANDARD AS480 AVR (SELF EXCITED) ± 1.0 % SELF EXCITED MACHINES DO NOT SUSTAIN A SHORT CIRCUIT CURRENT AS480 AVR WITH OPTIONAL EXCITATION BOOST SYSTEM (EBS) REFER TO SHORT CIRCUIT DECREMENT CURVE (page 8) INSULATION SYSTEM CLASS H PROTECTION RATED POWER FACTOR STATOR WINDING WINDING PITCH WINDING LEADS STATOR WDG. RESISTANCE ROTOR WDG. RESISTANCE EXCITER STATOR RESISTANCE EXCITER ROTOR RESISTANCE EBS STATOR RESISTANCE R.F.I. SUPPRESSION WAVEFORM DISTORTION MAXIMUM OVERSPEED BEARING DRIVE END BEARING NON-DRIVE END BS EN 600-6-2 & BS EN 600-6-4,VDE 0875G, VDE 0875N. refer to factory for others WEIGHT COMP. GENERATOR 80 kg 78.3 kg 83 kg 81.3 kg WEIGHT WOUND STATOR 27 kg 27 kg 27 kg 27 kg WEIGHT WOUND ROTOR 27.87 kg 26.17 kg 28.87 kg 27.17 kg WR² INERTIA 0.0953 kgm 2 0.0952 kgm 2 0.097 kgm 2 0.0953 kgm 2 SHIPPING WEIGHTS in a crate 0 kg 98.3 kg 9 kg 7.3 kg PACKING CRATE SIZE TELEPHONE INTERFERENCE COOLING AIR IP23 0.8 DOUBLE LAYER CONCENTRIC TWO THIRDS 12 1.327 Ohms PER PHASE AT 22 C SERIES STAR CONNECTED 1 BEARING 71 x 51 x 67 (cm) 0.415 Ohms at 22 C 17.5 Ohms at 22 C 0.211 Ohms PER PHASE AT 22 C 12.9 Ohms at 22 C NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% WITH EBS 50 THF<2% 2250 Rev/Min BALL. 6309-2RS. (ISO) BALL. 6306-2RS. (ISO) 2 BEARING WITHOUT EBS WITH EBS WITHOUT EBS 71 x 51 x 67 (cm) 60 TIF<50 0.1 m³/sec 233cfm 0.135 m³/sec 286 cfm VOLTAGE SERIES STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277 VOLTAGE PARALLEL STAR 190/1 200/115 208/120 220/127 208/120 220/127 230/133 240/138 VOLTAGE SERIES DELTA 220/1 230/115 240/120 254/127 240/120 254/127 266/133 277/138 kva BASE RATING FOR REACTANCE VALUES 9.5 11 11.8 12.1 12.5 Xd DIR. AXIS SYNCHRONOUS 1.86 1.68 1.56 1.32 2.20 2.11 1.98 1.88 X'd DIR. AXIS TRANSIENT 0.19 0.17 0.16 0.13 0.22 0.21 0.20 0.19 X''d DIR. AXIS SUBTRANSIENT 0.12 0.11 0. 0.09 0.15 0.14 0.13 0.13 Xq QUAD. AXIS REACTANCE 0.89 0.80 0.74 0.63 1.06 1.02 0.95 0.90 X''q QUAD. AXIS SUBTRANSIENT 0.19 0.17 0.16 0.13 0.23 0.22 0.21 0.20 XL LEAKAGE REACTANCE 0.07 0.06 0.06 0.05 0.08 0.08 0.07 0.07 X2 NEGATIVE SEQUENCE 0.16 0.14 0.13 0.11 0.19 0.18 0.17 0.16 X0 ZERO SEQUENCE 0.08 0.07 0.07 0.05 0.09 0.09 0.08 0.08 REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED T'd TRANSIENT TIME CONST. T''d SUB-TRANSTIME CONST. T'do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. SHORT CIRCUIT RATIO 0.007 s 0.002 s 0.17 s 0.007 s 1/Xd 3

50 PI044E Winding 311 THREE PHASE EFFICIENCY CURVES 4

60 PI044E Winding 311 THREE PHASE EFFICIENCY CURVES 5

30 50 PI044E Winding 311 AS480 AVR Without EBS Locked Rotor Motor Starting Curves 346V 380V 400V 415V 440V 25 PER CENT TRANSIENT VOLTAGE DIP. 20 15 5 0 30 25 0 2 4 6 8 12 14 16 18 20 LOCKED ROTOR kva 60 380V 416V 440V 460V 480V PER CENT TRANSIENT VOLTAGE DIP. 20 15 5 0 0 2 4 6 8 12 14 16 18 20 22 24 26 LOCKED ROTOR kva 6

30 50 PI044E Winding 311 AS480 AVR With EBS fitted Locked Rotor Motor Starting Curves 346V 380V 400V 415V 440V 25 PER CENT TRANSIENT VOLTAGE DIP. 20 15 5 0 30 25 0 2 4 6 8 12 14 16 18 20 22 LOCKED ROTOR kva 60 380V 416V 440V 460V 480V PER CENT TRANSIENT VOLTAGE DIP. 20 15 5 0 0 5 15 20 25 30 LOCKED ROTOR kva 7

PI044E WITH EBS FITTED Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed Based on star (wye) connection. 50 00 SYMMETRICAL CURRENT (Amps) 0 ASYMMETRICAL 60 Sustained Short Circuit = 55 Amps 0.001 0.01 TIME (secs) 0.1 1 00 CURRENT (Amps) 0 SYMMETRICAL ASYMMETRICAL 0.001 0.01 TIME (secs) 0.1 1 Sustained Short Circuit = 69 Amps Note 1 The following multiplication factors should be used to adjust the values from curve between time 0.001 seconds and the minimum current point in respect of nominal operating voltage : Note 2 The following multiplication factor should be used to convert the values calculated in accordance with NOTE 1 to those applicable to the various types of short circuit : 50 60 3-phase 2-phase L-L 1-phase L-N Voltage Factor Voltage Factor Instantaneous x 1.00 x 0.87 x 1.30 380v X 1.00 416v X 1.00 Minimum x 1.00 x 1.80 x 3.20 400v X 1.05 440v X 1.06 Sustained x 1.00 x 1.50 x 2.50 415v X 1.09 460v X 1. Max. sustained duration sec. 5 sec. 2 sec. 440v X 1.16 480v X 1.15 All other times are unchanged The sustained current value is constant irrespective Note 3 of voltage level Curves are drawn for Star (Wye) connected machines. For other connection the following multipliers should be applied to current values as shown : Parallel Star = Curve current value X 2 Series Delta = Curve current value X 1.732 8

PI044E Winding 311 / 0.8 Power Factor RATINGS Class - Temp Rise Cont. F - 5/40 C Cont. H - 125/40 C Standby - 150/40 C Standby - 163/27 C 50 Series Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440 Parallel Star (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220 Series Delta (V) 220 230 240 254 220 230 240 254 220 230 240 254 220 230 240 254 kva 9.1 9.1 9.1 8.6.0.0.0 9.5.8.8.8.3 11.0 11.0 11.0.5 kw 7.3 7.3 7.3 6.9 8.0 8.0 8.0 7.6 8.6 8.6 8.6 8.2 8.8 8.8 8.8 8.4 Efficiency (%) 80.9 81.3 81.5 82.0 80.0 80.5 80.8 81.5 79.1 79.7 80.0 80.9 78.8 79.4 79.8 80.7 kw Input 9.0 9.0 8.9 8.4.0 9.9 9.9 9.3.9.8.8.2 11.2 11.1 11.0.4 60 Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480 Parallel Star (V) 208 220 230 240 208 220 230 240 208 220 230 240 208 220 230 240 Delta (V) 240 254 266 277 240 254 266 277 240 254 266 277 240 254 266 277 kva.0.7 11.0 11.4 11.0 11.8 12.1 12.5 11.9 12.7 13.1 13.5 12.1 12.9 13.3 13.8 kw 8.0 8.6 8.8 9.1 8.8 9.4 9.7.0 9.5.2.5.8 9.7.3.6 11.0 Efficiency (%) 81.4 81.5 81.7 81.7 80.8 80.8 81.0 81.1 80.1 80.1 80.3 80.4 80.0 80.0 80.1 80.1 kw Input 9.8.5.8 11.2.9 11.7 11.9 12.3 11.9 12.7 13.1 13.4 12.1 12.9 13.3 13.8 DIMENSIONS 9

Head Office Address: Barnack Road, Stamford Lincolnshire, PE9 2NB United Kingdom Tel: +44 (0) 1780 484000 Fax: +44 (0) 1780 4840 www.cumminsgeneratortechnologies.com Copyright 20, Cummins Generator Technologies Ltd, All Rights Reserved Stamford and AvK are registered trade marks of Cummins Generator Technologies Ltd Cummins and the Cummins logo are registered trade marks of Cummins Inc. PI044E-311-TD-EN-SG-A