BCI184E - Technical Data Sheet

Similar documents
UCI274C - Technical Data Sheet

UCI274H - Technical Data Sheet

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

PM734F - Technical Data Sheet Winding 28

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

3790 en / d. Alternators LSA Pole. Electrical and mechanical data

IGSA POWER GENERATION SYSTEMS

STAMFORD Product Guide

CUKUROVA GENERATOR SYSTEMS

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

SYNCHRONOUS MACHINES

Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Physical Address: City: State: Zip Code:

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

DIESEL GENERATOR SETS

CUMMINS SERIE 6B. Definiciónes. Potencia Prime. Potencia Stand by. Estos valores son aplicables para el suministro de energía eléctrica continua

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

AC-Synchronous Generator

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

CUKUROVA GENERATOR SYSTEMS

Automatic Voltage Regulator User s Manual

Basics of Electricity

FAULT FINDING MANUAL. For Stamford AC Generators

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

WIND TURBINE TECHNOLOGY

R448 & R448 V50 A.V.R.

Lab 8: DC generators: shunt, series, and compounded.

CUKUROVA GENERATOR SYSTEMS

Diesel Generator Set Model DFHC 60 Hz

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

Generators TEM. for small hydroelectric power stations. Electric Machines

Diesel Generator Set Model DFMB 60 Hz

Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting, excitation system

Paralleling Power Sources Which Share a Common Neutral

Mounting Instructions. Torque Transducer. A en

Verification of Short Circuit Test Results of Salient Poles Synchronous Generator

Rules for Classification and Construction Additional Rules and Guidelines

Spark-ignited generator set

FIT TIER 2 Application

R438 A.V.R. Installation and maintenance R 438. This manual is to be given to. the end user T10. Armature 6- Field X2 Z1 X1 Z2 E+ E- 0V

Single-Phase AC Synchronous Generator

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

FAULT FINDING MANUAL For Self Excited and Separately Excited Generators

Thyristor-controlled power supplies and battery chargers

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Diesel Engine Driven Generators Page 1 of 6

Torque motors. direct drive technology

Diesel Generator Set Model DGDK 60 Hz

CUKUROVA GENERATOR SYSTEMS

The reliability of the grid

FREQUENCY CONTROLLED AC MOTOR DRIVE

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

How To Control A Power Command Powerplant

Type SA-1 Generator Differential Relay

SUNON SPECIFICATION FOR APPROVAL

Offshore Platform Powered With New Electrical Motor Drive System

Solving VFD-sourced Bearing Current Problems in AC Motors.

SX460. Generator Automatic Voltage Regulator Operation Manual

Power Quality Paper #3

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

Synchronous motor. Type. Non-excited motors

Principles of Adjustable Frequency Drives

RM4TG20 three-phase network control relay RM4-T - range V

C Standard AC Motors

ST Style Generator. Owners/Operators Manual

Harmonics in your electrical system

Welcome to Linear Controls Quarterly Training

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

COMPUTER AIDED ELECTRICAL DRAWING (CAED) 10EE65

TABLE OF CONTENTS INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...

ET 332b Ac Electric Machines and Power Systems

Annex-A TECHNICAL SPECIFICATION

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

Understanding the Alternator

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION

Motor Fundamentals. DC Motor

3753 en /b VE/B - VE/RG Va V riable speed drives

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, HP

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

How the efficiency of induction motor is measured?

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

Circulating Current Relay. Type IRXm

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

INSTALLATION, SERVICE AND MAINTENANCE MANUAL

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

Transcription:

BCI184E - Technical Data Sheet

BCI184E SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359. Other standards and certifications can be considered on request. TERMINALS & TERMINAL BOX Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access. VOLTAGE REGULATORS SX460 AVR - STANDARD With this self excited control system the main stator supplies power via the Automatic Voltage Regulator (AVR) to the exciter stator. The high efficiency semiconductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three phase full wave bridge rectifier. This rectifier is protected by a surge suppressor against surges caused, for example, by short circuit. SA465 AVR The SA465 shares all the features of the SX460, but additionally will support a range of electronic accessories, such as a droop Current Transformer (CT) to permit parallel operation with other ac generators. Voltage regulation is improved by use of this AVR. SX421 AVR When the SX421 AVR is supplied for use with a BC generator, it will be supplied loose for fitting in the setbuilder s control panel. This AVR also operates in a self-excited system. It combines all the features of the SA465 with, additionally, three-phase rms sensing for improved regulation and performance. Over voltage protection is provided via a separate circuit breaker. An engine relief load acceptance feature is built in as standard. SHAFT & KEYS All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. INSULATION/IMPREGNATION The insulation system is class 'H'. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%. WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion. NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing typical of product range. 2

BCI184E WINDING 311 CONTROL SYSTEM A.V.R. VOLTAGE REGULATION SUSTAINED SHORT CIRCUIT INSULATION SYSTEM PROTECTION RATED POWER FACTOR STATOR WINDING WINDING PITCH WINDING LEADS STATOR WDG. RESISTANCE ROTOR WDG. RESISTANCE EXCITER STATOR RESISTANCE EXCITER ROTOR RESISTANCE R.F.I. SUPPRESSION WAVEFORM DISTORTION MAXIMUM OVERSPEED BEARING DRIVE END BEARING NON-DRIVE END WEIGHT COMP. GENERATOR WEIGHT WOUND STATOR WEIGHT WOUND ROTOR WR² INERTIA SHIPPING WEIGHTS in a crate SELF EXCITED STANDARD SX460 OPTIONAL SA465 SX421 (SUPPLIED LOOSE) ± 1.5 % ± 1.0 % ± 0.5 % SELF EXCITED MACHINES DO NOT SUSTAIN A SHORT CIRCUIT CURRENT CLASS H IP23 0.8 DOUBLE LAYER CONCENTRIC TWO THIRDS 12 0.354 Ohms PER PHASE AT 22 C SERIES STAR CONNECTED 0.64 Ohms at 22 C 20 Ohms at 22 C 0.105 Ohms PER PHASE AT 22 C BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% 2250 Rev/Min BALL. 6309-2RS. (ISO) BALL. 6306-2RS. (ISO) 1 BEARING 2 BEARING 128 kg 131 kg 43.6 kg 43.6 kg 40.69 kg 41.47 kg 0.1568 kgm 2 0.1568 kgm 2 133 kg 141 kg PACKING CRATE SIZE TELEPHONE INTERFERENCE 84 x 59 x 75 (cm) 50 THF<2% 84 x 59 x 75 (cm) 60 TIF<50 COOLING AIR 0.095 m³/sec 200 cfm 0.119 m³/sec 250 cfm VOLTAGE SERIES STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277 VOLTAGE PARALLEL STAR 190/110 200/115 208/120 220/127 208/120 220/127 230/133 240/138 VOLTAGE SERIES DELTA 220/110 230/115 240/120 254/127 240/120 254/127 266/133 277/138 kva BASE RATING FOR REACTANCE VALUES 22.5 22.5 22.5 17.5 27.5 28.8 28.8 30 Xd DIR. AXIS SYNCHRONOUS 1.873 1.690 1.570 1.796 2.294 2.148 1.965 1.880 X'd DIR. AXIS TRANSIENT 0.188 0.170 0.158 0.180 0.232 0.217 0.199 0.190 X''d DIR. AXIS SUBTRANSIENT 0.122 0.110 0.102 0.117 0.146 0.137 0.125 0.120 Xq QUAD. AXIS REACTANCE 0.931 0.840 0.780 0.892 1.135 1.063 0.972 0.930 X''q QUAD. AXIS SUBTRANSIENT 0.211 0.190 0.177 0.202 0.256 0.240 0.220 0.210 XL LEAKAGE REACTANCE 0.075 0.068 0.063 0.072 0.093 0.087 0.079 0.076 X2 NEGATIVE SEQUENCE 0.177 0.160 0.149 0.170 0.207 0.194 0.178 0.170 X0 ZERO SEQUENCE 0.081 0.073 0.068 0.077 0.099 0.093 0.085 0.081 REACTANCES ARE SATURATED T'd TRANSIENT TIME CONST. T''d SUB-TRANSTIME CONST. T'do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. SHORT CIRCUIT RATIO VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED 0.02 s 0.005 s 0.4 s 0.006 s 1/Xd 3

50 BCI184E Winding 311 THREE PHASE EFFICIENCY CURVES 4

BCI184E Winding 311 THREE PHASE EFFICIENCY CURVES 60 5

30 50 BCI184E Winding 311 Locked Rotor Motor Starting Curve 346V 380V 400V 415V 440V 25 PER CENT TRANSIENT VOLTAGE DIP 20 15 10 5 0 0 5 10 15 20 25 30 35 40 45 50 LOCKED ROTOR kva 30 60 380V 416V 440V 460 480V 25 PER CENT TRANSIENT VOLTAGE DIP 20 15 10 5 0 0 10 20 30 40 50 60 70 LOCKED ROTOR kva 6

BCI184E Page left blank intentionally 7

50 Class - Temp Rise BCI184E Winding 311 / 0.8 Power Factor RATINGS Cont. F - 105/40 C Cont. H - 125/40 C Standby - 150/40 C Standby - 163/27 C Series Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440 Parallel Star (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220 Series Delta (V) 220 230 240 254 220 230 240 254 220 230 240 254 220 230 240 254 kva 20.0 20.0 20.0 15.6 22.5 22.5 22.5 17.5 kw 16.0 16.0 16.0 12.5 18.0 18.0 18.0 14.0 Efficiency (%) 84.8 85.2 85.4 85.7 83.7 84.2 84.5 84.9 kw Input 18.9 18.8 18.7 18.7 21.5 21.4 21.3 21.2 N/A N/A 60 Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480 Parallel Star (V) 208 220 230 240 208 220 230 240 208 220 230 240 208 220 230 240 Series Delta (V) 240 254 266 277 240 254 266 277 240 254 266 277 240 254 266 277 kva 25.0 26.3 26.3 28.1 27.5 28.8 28.8 30.0 kw 20.0 21.0 21.0 22.5 22.0 23.0 23.0 24.0 Efficiency (%) 84.4 84.5 85.0 84.8 83.4 83.6 84.1 84.2 kw Input 23.7 24.9 24.8 26.5 26.4 27.6 27.4 28.5 N/A N/A DIMENSIONS 2004 Newage International Limited. Reprinted with permission of N.I. only. Printed in England. Barnack Road Stamford Lincolnshire PE9 2NB Tel: 00 44 (0)1780 484000 Fax: 00 44 (0)1780 484100 Website: www.newage-avkseg.com TD_BCI184E.GB_12.03_03_GB