Fire Doors Explained. Presented by - Peter Barker

Similar documents
Code of Practice for fire resisting metal doorsets

The Role of Fire Doors. BWF-Certifire Fire Door and Doorset Scheme

FIRE-RESISTANT GLAZING Mr Leslie O May Sales Consultant Wright Style Limited England

Guidance on loft conversions in two-storey houses

LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market

Fire-Rated Glass and Glazing START

Introduction to cable fire stopping

Fire Doors The Role of a Fire Door

ASFP Ireland - Fire Safety Certification. Colin Keeley Senior Site Inspector & Training Officer 22 nd September 2011

Fire Security Systems

ASFPI Fire Compartmentation Seminar

Fire Resistant Systems

Passive Fire Protection Guidance for the Fire Risk Assessor. Niall Rowan Technical Officer Association for Specialist Fire Protection

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

Fire and Security Products and Services

Safety Storage Cabinets

Approved Document Q: Security

GENERAL FIRE SAFETY TERMS & DEFINITIONS

Loss Prevention Standard

Fire Protection Of Ventilation Systems DAMPERS & AIR TRANSFER GRILLES A PRESENTATION BY PHILLIP HORTON OF FIRE ENGINEERING SOLUTIONS

Fire Stopping and Penetration Seals for the Construction Industry SECOND EDITION

- 5 - Table1. Maximum Compartment Volumes

Building Control Guidance Note

Fire safety in timber buildings

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

A Guide to Best Practice in the Specification and Use of Fire-Resistant Glazed Systems

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

How To Write A Fire Risk Assessment

REPORT ON THE TESTING OF SEALED UNITS TO VERIFY THE IMPACT OF PRESSURE EQUALISATION ON INSULATION VALUES.

The risk assessment of fire damper installations

SCHOTT PYRANOVA Planline System

Firecode fire safety in the NHS Health Technical Memorandum 05-02: Guidance in support of functional provisions for healthcare premises

the importance of fire consultancy

Fire Doors Basic Guidance & Checklist

Relevant British, European and International standards

Loss Prevention Standard

Fire Barriers & Fire Stopping

>active antimicrobial wall cladding for hygienic environments

FIRE RATED GLAZING System Guide

Ensuring Best Practice for passive fire protection in buildings

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

Colorcoat Technical Paper Fire performance of pre-finished steel cladding systems

Understanding fire-resistant glazing systems. Presented by Russell Day Technical officer The Glass and Glazing Federation

FIRE RISK ASSESSMENT COMPETENCY COUNCIL

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS

CERTIFICATE OF APPROVAL No CF 388 ALLEGION (UK) LIMITED

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

DOMESTIC WINDOW SECURITY

Gordon Cooke BSc PhD CEng MICE MIMechE FIFireE

The Danish Enterprise and Construction Authority to inspect CE marking of windows and pedestrian doors

Improving fire safety through engineering (rational designs)

Property Accreditation Standards 2014/2015

Security Dwellings. The Building Regulations edition for use in England* ONLINE VERSION APPROVED DOCUMENT ONLINE VERSION

Tremco Fire Protection Systems Group Technical Bulletin

ONLINE VERSION ONLINE VERSION

CI/SfB Ro8 (K3) February Fire-Resistant Glass Range. Pilkington Pyrostop Pilkington Pyrodur Pilkington Pyroshield

Loss Prevention Standard

Fire Safety Requirements for Child Care Centre

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

ISSUE 2. Installation Guide

Guide to the safe installation of downlighters in dwellings

Designing Out Crime Assessment

Preventing arson in buildings

INTERNATIONAL FIRE PROTECTION

CI/SfB (31.5) Xn (U46) 07/05. A complete range of

1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety.

An overview of mechanical lock and security related standards and why they re important to the Insurance Industry

Association of British nsurers LPC. A Code of Practice for the Protection of Business

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!

The FIRE BOOK. Passive fire protection solutions

Practice Note for Authorized Persons, Buildings Department Registered Structural Engineers and APP-13 Registered Geotechnical Engineers

Office of the State Fire Marshal. Fire Rated Doors

A Guide to the European Standard for Safety Storage Cabinets (BS EN )

Hygienic Doors for the Healthcare Sector

ON MOST schemes, the architectural design of. Flexible strategy. Case study. The Forum

ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website

The complete answer to secondary glazing. High performance secondary glazing solutions for new and refurbished buildings

London Borough of Barnet. Fire Safety in Houses in Multiple Occupation. A Guide to Landlords

Fire safety ONLINE VERSION APPROVED DOCUMENT VOLUME 2 BUILDINGS OTHER THAN DWELLINGHOUSES ONLINE VERSION. The Building Regulations 2010

Put us to the test. Construction testing and building investigations services from BRE.

FIRE DOORS - GENERAL SPECIFICATIONS / EMPLOYERS REQUIREMENTS (ERs) & QUICK OVERVIEW

A study of the nature of fire risks in tall buildings

The terms hazard and risk are often used, which we define as the following:

THE HONG KONG INSTITUTION OF ENGINEERS 香 港 工 程 師 學 會. Admission Requirements for the Fire Discipline (Normal Route) Item Description Remarks

English Version. Fire safety storage cabinets - Part 2: Safety cabinets for pressurised gas cylinders

Report Number BTC 17755F

Fire Safety Management Strategy

Terms and Definitions In Canada

A GUIDE TO WINDOW AND DOOR SELECTION

Electrical installations and their impact on the fire performance of buildings:

Fire Safety in High Rise Residential Blocks

Composite Panel Firewall Systems

A1 Example fire safety maintenance checklist

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

For the Design, Installation, Commissioning & Maintenance of Fixed Gaseous Fire Suppression Systems

Transcription:

Fire Doors Explained Presented by - Peter Barker

Objectives and Outline 1. The role of fire resisting doors 2. Proving the performance of fire resisting doors 3. Common problems and solutions

The Role of Fire Doors Building regulations Parts A-M Applies to new buildings and those undergoing substantial alteration or a change of use Functional building regulations Technical Document Guidance B

The Role of Fire Doors Part B of Building Regulations Provide building occupants with sufficient means of escape to reach places of safety before the environment becomes life threatening: - B1 Means of warning and escape - B2 Internal fire spread (linings) - B3 Internal fire spread (structure) - B4 External fire spread - B5 Access and facilities for the fire service

The Role of Fire Doors Section B3 of the Building Regulations requires: buildings are designed to maintain stability of construction walls are constructed to resist spread of fire between buildings internal fire spread to be inhibited by sub-division of the building and/or installation of fire suppression systems building designed to inhibit unseen spread of fire and smoke

The Role of Fire Doors Section B3 defined as: Compartmentation Passive and Active Fire Protection Built In Fire Protection Image source: PFPF Guide http://pfpf.org

Proving the Performance of Fire Doors Test standards for measuring fire resistance: BS 476: Part 22: 1987 (British Standard) BS EN 1634-1: 2008 (European Normative standard) To facilitate the use of the new European fire test methods within the approval process (CE marking) Both are acceptable within the ROI Came into effect on 1st March 2003 TGD B - Appendix A: Performance of materials and structures TGD B - Appendix B: Fire doors

Proving the Performance of Fire Doors A doorset may be called fire resisting if the complete design has been subjected to a full scale fire resistance test to one of the current test standards for non-loadbearing elements: - BS 476: Part 22: 1987 - BS EN 1634-1: 2008 It is important to understand that the test standards are a measure of performance: - They do not detail constructional requirements - There is no such thing as a blue print for a fire door

Proving the Performance of Fire Doors Evidence to show compliance with building regulations may be obtained via: A destructive fire test to BS or EN standards An assessment Fire resistance tests will be carried out at independent, nationally accredited laboratories. Typically UKAS (United Kingdom Accreditation Service) accredited laboratories - such as Chiltern International Fire Assessments are to be written by qualified fire consultants

Proving the Performance of Fire Doors Fully Developed Compartment Fire with Combustible Linings

Proving the Performance of Fire Doors 1200 1000 B1 B3 945 C 1006 C B4 1049 C 800 842 C Temperature ( C) 600 400 781 C Melting point of aluminium Critical temperature of structural steel B2 350-650 C Auto ignition of timber 200 200-300 C Flash ignition of timber Intumescent seals begin to activate B5 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Time (min)

Proving the Performance of Fire Doors A report of the test will then normally be written stating: conditions under which the test was conducted construction details of the specimen and installation a record of the data obtained during the test, including: - thermocouple temperatures - distortion measurements - a graph showing the temperature curve - observations of the test engineer most importantly, the report will state the integrity and insulation performance of a construction in terms of minutes to failure.

Proving the Performance of Fire Doors Test reports are statements of fact and therefore only apply to exactly what has been tested - no more and no less. Assessments, however, are statements of expert opinion based on observed test performance. They allow both engineering expertise and the experience accumulated from other tests to be added to the facts of a particular test. There are two basic types of assessment: Global and Job Specific.

Proving the Performance of Fire Doors Manufacturers choose to have global assessments produced because: they provide a definite range of cover for the doorset they avoid the need to re-test for minor changes they provide confidence that the manufacturer is maximising their test data

Proving the Performance of Fire Doors Job specific assessments needed when: a project specific document is required by the client or local authority the requirements of the proposed construction fall outside the boundaries of a global assessment the fire authorities may want specific confirmation of fire resistance a site survey is needed to assess existing doors

Emirates Stadium

St Pancras Station

Common Problems Understand what is being asked for (unusual design? Specific hardware or additional performance requirement?) Ensure it is supported by test evidence or assessment of performance Correct construction of fire doors Correct installation of fire doors Correct maintenance of fire doors Fire risk assessments The relevance of 3 rd Party Certification

Common Problems

Common Problems

Common Problems Typical FD30 and FD60 proprietary glazing systems Steel pins or screws at 35-40 to the glass Proprietary intumescent detail Steel pins or screws at 35-40 to the glass No aperture liner Aperture liner Basic FD30 detail Basic FD60 detail

Common Problems Damage to glazing and incorrect glazing specification

Common Problems

Common Problems Hardware changed and voids not made good

Common Problems

Common Problems

Common Problems

Ensuring Correct Solutions - 3 rd Party Certification of Products - 3 rd Party Certification of Personnel - Training of Personnel responsible for maintenance - Consultation during the early stages of planning

Summary Fire doors play a key role in fire protection Fire doors are performance products Fire doors must be correctly built in accordance with test evidence or assessment documentation Common problems on site can be prevented 3 rd Party Certification of products and personnel provides confidence in the performance of the product and competence of personnel