225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators



Similar documents
Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Quick running actuator

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Air damper actuators

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Electric Rotary Actuator - On/Off or programmable control actuator

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Actuator for modulating control AME 435

PNOZsigma - Base units

80 Series - Modular timers 16 A. Features

HERZ-Thermal Actuators

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Analog signal converters CC-E I/I Current / current isolators

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Electronic overload relay EF65, EF96 and EF146

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

48 SERIES Relay interface modules 10 A

E-STOP relays, safety gate monitors

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Electronic overload relay EF19 and EF45

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

RM4TG20 three-phase network control relay RM4-T - range V

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

OTM_F_C_. Installation instruction 34OTM_F_C_ / 1SCC303009M0201

Contact expansion modules

Digital input modules

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Quick Connect. quick - simple - efficient.

Electronic Control Devices The European Product Catalogue 2007

Safety technique. Emergency stop module BO 5988 safemaster

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

3-phase, bidirectional energy meter

Product and functional description

Series 6000 Torque measured metal bellow coupling

Contact expander modules

VAV system solution for non-pressure-dependent applications in enclosed spaces

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Description. Dimensions. Features. precision works better

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

Redundancy Module QUINT-DIODE/40

Capteur température et humidité pour HVAC

38 Series - Relay interface modules A

Short information Parameters are programmed via front-side membrane keypad

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

TX OPEN RS232/485 module

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Cable Plug acc. to DIN EN , Form A

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Safety automation solutions

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

E-STOP relays, safety gate monitors

80 Series - Modular timers 16 A. Features

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

RY2 miniature industrial relays

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

49 Series - Relay interface modules A. Features

SMOKE DAMPERS IMOS DKI-1 TECHNICAL CONDITIONS TPI (DAMPERS FOR EMISSION EXHAUST) FOR ONE FIRE AREA

LED Driver Compact dimming. Udriver LCAI 35W 350mA 900mA ECO C ECO series

GREISINGER electronic GmbH

38 Series - Relay interface modules A

MasterINTERFACE 39 Series - Relay interface modules

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Pluggable interface relays CR-P Pcb relays

PHOENIX CONTACT Features

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

MasterINTERFACE 39 Series - Relay interface modules

VAV compact controller KNX / PL-Link

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Three-phase monitoring relay CM-PFE

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

E-STOP relays, safety gate monitors

IO-RM3 3-Stage Relay Module

EBS852 (Contrac) Power Electronic Unit

VAV compact controller KNX / PL-Link

13 SERIES. Electronic step relays A

Transcription:

Actuators Technical data sheet 225C-024T-05 Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5 Nm Nominal Voltage 24 VAC/DC Control Continuous control DC 0(2)...10 V Damper size up to approx. 1 m² Damper coupling Clamp 8-12 mm / Ø 8-16 mm Technical data Nominal voltage Nominal voltage 24 VAC/DC Nominal voltage range 19...29 VAC/DC Power consuption Motor (Motion) 1,5 W Power consuption Standby (end position) 1,0 W Wire sizing 3,0 VA Control Continuous control 0(2)...10 VDC / (0)4...20 ma / Ri >100 kω Position feedback 0(2)...10 VDC, max 5 ma Auxiliary switch - Contact load - Switching point - Connection Motor screw terminals, on cable 0,5...1,5mm² Connection Auxiliary switch - Connection Position feedback - Connection GUAC - Functional data Torque Motor > 5 Nm Synchronised speed - Direction of rotation selected by switch Manual override Gearing latch disengaged with pushbutton, self-resetting Angle of rotation 0... max. 95 Can be limited with adjustable mechanical end stop min 20 Running time Motor 60...120 s / 90 Sound power level Motor < 35 db(a) Damper coupling clamp 8-12 mm/ Ø 8-16 mm 2013-07-30 11:17:07 Copyright by GRUNER AG Subject to change in technology and Design 1

Technical data Functional data Position indication mechanical with pointer Service life > 60'000 cycles (0-95 - 0 ) Safety Protection class III (low voltage safety current) Degree of protection IP 52 (Cable port downwards) EMC CE (2004/108/EG) LVD CE (2006/95/EG) RoHS CE (2011/65/EU) Mode of operation Typ 1 (EN 60730-1) Rated impulse voltage 0,8 kv (EN 60730-1) Control pollution degree 3 (EN 60730-1) Ambient temperature Normal operation -30...+50 Storage temperature -30...+80 Ambient humidity 5...95% r.f., non- condensating (EN 60730-1) Maintenance maintenance free Dimensions/ Weight Dimensions 145 x 65 x 61 mm Weight ca. 530 g Operating mode / Properties Operating mode Through connecting the power supply to 1+2 and a reference signal Y to 3 of [0(2) 10VDC], moves the actuator to its specified position. The actual damper position 0 100% is a feedback signal U for example to share the signal with other actuators. The actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. Direct mounting Simple direct mounting on the damper spindle with a universal spindle clamp, supplied with an anti-rotation strap to prevent the actuator from rotating. Manual override Manual override is possible with the self-resetting pushbutton (the gearing latch remains disengaged as long as the pushbutton is pressed) Mode- switch DIP-Switch under the case cover Adaption drive -Adaption on angle of rotation < 90 -Actuator power-off -Setting the mechanical end stops -Actuater power-on -Adaption to enable -Actuator adaption on angular range -Adaption to disable - Y refers to the measured angular range 2013-07-30 11:17:07 Copyright by GRUNER AG Subject to change in technology and Design 2

Connection / Safety remarks Safety remarks -Connect via safety isolation transformer -The actuator is not allowed to be used outside the specified field of application, especially in airplanes. -In may only be installed by suitably trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. -The device may only be opened at the manufacturer s site. -When calculating the required torque, the specifications supplied by the damper manufacturers (cross- section, design, installation site), and the air flow conditions must be observed. -The actuator is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. 2013-07-30 11:17:08 Copyright by GRUNER AG Subject to change in technology and Design 3

Technical drawing 2013-07-30 11:17:09 Copyright by GRUNER AG Subject to change in technology and Design 4

Powered by TCPDF (www.tcpdf.org) 225C-024T-05 Gruner AG post office box (P.O.Box) 1149 D-78564 Wehingen Tel. +49 7426 948-0 Fax +49 7426 948-200 www.gruner.de info@gruner.de 5 2013-07-30 11:17:09 Copyright by GRUNER AG Subject to change in technology and Design