SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function



Similar documents
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Electric Rotary Actuator - On/Off or programmable control actuator

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

! WARNING. Before using product, read and understand instructions.

Centro-Matic Automatic Lubrication Systems System Controls

8146/5 Series Breaker Panelboards

Hydraulic Control Solutions

Pressure Switch for gas and air

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

LIEBERT VNSA Installation Sheet

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

4 Posiflow Proportional Solenoid Valves

Technical Information RIA14

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

POWERS CONTROL RC 195 Single Input Receiver-Controller

Industrial Hydraulic Remote Controlled Monitor

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

HMI display Installation Guide

Digital input modules

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

DUCT SMOKE DETECTOR D4120

Advantium 2 Plus Alarm

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Series 71, 72, and 76 Modutrol IV Motors

Air damper actuators

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

M A N U A L

SECTION LOW VOLTAGE LIGHTING CONTROLS

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Speed Control Relays SX2

Adjustable room thermostat for heating only or cooling only systems

HERZ-Thermal Actuators

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

2740 Whitten Rd Bldg 103 Memphis, TN Telephone

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

CompactLogix Power Supplies Specifications

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

2/2 and 3/2 Way Size 6 Seat Valves

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

MCR1900 Media Converter 19-Slot Chassis

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

AMPSEAL* Automotive Plug Connector and Header Assembly

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Circuit Breakers. NRC Series. NRC Series

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

TX OPEN RS232/485 module

Reaction Torque Sensor

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

Joystick PVRES and PVREL. Technical Information

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Machine Safety Switch: SI-LM40 Series Limit Switch Style

TorqPlus TM Electric Valve Actuators and Controls

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Compact pressure switch Flameproof enclosure Ex d Model PCA

Scraper Passage Indicator. Electrical Indicator. Features

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

General Purpose Relays Types K, R, N, and C

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Machine Safety Switches

Fire Pump Controllers Remote Alarm Panels

RC 195 Multiple Input Receiver-Controller

BULLETIN OCTOBER DeZURIK ROTARY DIAPHRAGM ACTUATORS

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

Universal Voltage Terminal Photoelectric E3JM

Electronic, Digital and Mechanical Vibration Switches

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Technical Specification. Generating Set with Waukesha engine burning natural gas

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Liquid Level Limit Switch liquiphant T FTL 20

OPL BASIC. Dosing System for Professional Laundry machines. Contents

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Modular I/O System Analog and Digital Interface Modules

Flow switches Series AD/VH

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Uni-Valve A /S UNI-ITS. UNI-ITS100 - Mechanical switches. Installation and operating manual. Position monitoring switch

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Electro-Pneumatic Bus Door Control Mechanism

Diesel Engine Driven Generators Page 1 of 6

3/2-way Solenoid Valve, direct-acting, NC or NO

Transcription:

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with VG series gas valves to provide safety shut-off control for industrial and commercial burner applications. The compact SKP15 actuator opens slowly and closes immediately when power is interrupted. The modular design allows the SKP15 to be used in combination with all VG series gas valves bodies from 1/2-inch to 6 inches in size. The actuator easily mounts on the square flange of any VG valve with four pre-mounted screws. A visible position indicator on the front of the actuator displays the entire stroke of the valve. A light indicates when the actuator is powered. Features UL listed, FM approved, CSA certified for USA and Canada, and ISO 9001 certified. European, Australian and Japanese approved versions available. Application Proof of Closure with Over Travel (POC versions. Optional NEMA 4 protection. Visual position indication. "Power on" indication light Quick connect wiring terminals Optional adjustable auxiliary switch available. Modular design with 360 o actuator rotation for easy field wiring and installation. Low, 13.5 VA power consumption. SKP15 series actuators are combined with 1/2-inch to 6-inch VG series gas valve bodies. VG series gas valves must be ordered separately (See VGU... Technical Instructions, P/N 155-512P25. Siemens Building Technologies, Inc.

SKP15...U Electro-hydraulic Actuators Product Numbers Table 1. Product Number 1 Operating Voltage Proof of Closure Switch 2 Auxiliary Switch 2 Type of Switch SKP15.013U1 SKP15.012U1 110 to 120 Vac X X SPDT SPDT SKP15.011U1 X SPDT SKP15.013U2 220 to 240 Vac SKP15.012U2 X X SPDT SPDT Note: 1. European, CE certified models are available (see data sheet 7643 2. Proof of closure and auxiliary switches cannot be field installed. Accessories AGA66 Sealing gasket to provide NEMA 3, 3R, and 4 protection (for VGG/VGDvalves Specifications Agency approvals As safety shut-off valve UL/429, FM/7400, ANSI Z21.21/CGA6.5 C/I Agency marks apply only for SKPxx.xxxU actuators with VGxxx.xxxU series gas valve bodies. Power supply Operating voltage 110 to 120 Vac + 10% to -15% 220 to 240 Vac + 10% to -15% Operating frequency 50 to 60 Hz + 6% Power consumption 13.5 VA Duty cycle continuous Operating environment Ambient operating temperature 5 F to 140 F ( 15 C to 60 C Mounting position Any position except upside down Physical characteristics Weight 2.4 lb (1.1 kg Enclosure NEMA 1, 2, 5, and 12 for indoor use NEMA 3, 3R, and 4 with optional AGA66 gasket Dimensions See Figure 3 Specification for valve bodies See gas valve, P/N 155-512P25 Conduit connection Two 1/2-inch NPSM threaded knock-outs Electrical connection Spring loaded terminals for 14 AWG wires Operating characteristics Output force 100 lb (450 N Maximum stroke 1 inch (26 mm Opening time for maximum stroke Varies with valve size, 14 seconds for max. stroke Closing time <0.8 seconds Auxiliary features Proof of closure switch Non-adjustable Setting range of auxiliary switch 40% to 100% of stroke Switch rating 6A/250 Vac resistive; 3A/120 Vac pilot duty Page 2 Siemens Building Technologies, Inc.

SKP15U Electro-hydraulic Actuators Operation Installation Figure 1. SKP15 Operation. The electro-hydraulic actuator consists of a cylinder filled with oil, a piston containing an electric oscillating pump, and a relief system. When power is supplied to the actuator, the relief system closes, and the pump moves oil from the reservoir into the pressure chamber. This action causes the piston to move downward in the cylinder, opening the gas valve. When power to the actuator is interrupted, the relief system opens and the gas valve closes in less than 0.8 seconds. A position indicator, visible through the transparent portion of the terminal cover, shows the entire stroke range of the actuator. A light, which is visible through the lower left transparent portion of the terminal cover, indicates when the actuator receives power. An optional, non-adjustable SPDT proof of closure over travel switch signals the closed position after the gas valve has closed. An optional SPDT auxiliary switch is adjustable between 40% and 100% of the stroke. The adjustment screw and scale are located on the right side in the terminal box, and are visible through the transparent portion of the terminal cover. WARNING: Personal injury or loss of life may occur if procedures are not followed as specified. All installations must be performed by qualified personnel only. Do not pull the actuator shaft. The AGA66 gasket must be installed between the actuator and the gas valve body to provide NEMA 3, 3R, and 4 protection rating for VGG and VGD valves. The SKP15 actuator is directly coupled to the VG series valve body by four premounted 4 mm Allen key screws. The square mounting flange can be rotated in steps of 90 o to provide four different mounting positions. The SKP15 actuator can be mounted in any position except upside down. The actuator can be mounted or replaced while the valve body is under pressure. The SKP15 actuator has two knock-outs for the installation of 1/2-14 NPSM conduit connections. When conduit routing is connected, flexible conduit must be used. Liquid tight conduit must be used in combination with AGA66 to provide NEMA 3, 3R, and 4 protection. The terminal marked GND, located above the wiring terminals, must be connected to the electrical ground. Siemens Building Technologies, Inc. Page 3

Installation, Continued Wiring and Switch Adjustment (See Terminal Designations NOTE: Wiring must meet all relevant electrical codes. SKP15U Electro-hydraulic Actuators The actuator is equipped with spring-loaded terminals for 14 AWG wires. The actuator has two line and two neutral terminals. Insert one wire into the opening of the terminal while pressing the lever downward with a screwdriver or hard object. Make sure that all strands insert into the opening. Adjust the auxiliary switch (if provided according to the wiring diagram on the label below the terminals (see Figure 2. The adjustment screw and scale are located on the right side of the terminal box, and are visible through the transparent portion of the terminal cover. NOTES: 1. The auxiliary switch is adjustable between 40% and 100% of the stroke. The factory setting is at 40%. 2. The auxiliary switch must not be used for proof of closure detection or other safety interlock functions. 3. The Proof of Closure Switch is non-adjustable. Service Terminal Designations There are no serviceable parts on the SKP15 series actuators. If inoperative, replace the entire actuator. Tag wires before servicing. SKP15.012U SKP15.011U SKP15.013U Figure 2. Terminal Designations. Siemens Building Technologies, Inc. Page 4

SKP15U Electro-hydraulic Actuators Dimensions (Dimensions in inches; millimeters in brackets Figure 3. SKP15U.. Dimensions. Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Other product or company names mentioned herein may be the trademarks of their respective owners. 2005 Siemens Building Technologies, Inc. SCC Inc. 1250 Lunt Avenue Elk Grove Village, IL 60007 U.S.A. Your feedback is important to us. If you have comments about this document, please send them to techsupport@scccombustion.com Document No. 155-751 Country of Origin: US Page 5