Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55



Similar documents
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Thermo Top - Troubleshooting Tree

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS


Thermo 90 S B (Gasoline) Thermo 90 S D (Diesel) Thermo 90 ST B (Gasoline) Thermo 90 ST D (Diesel)

HeatSource HS1800 Heater

HEAVY DUTY STORAGE GAS

TECHNICAL SPECIFICATION TYPE ATESO ALFA

Fossil fuel heating equipment

Air Top 3500/ Circuit Diagrams

Portable Air Conditioner

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Luft-Heizgeräte 03/2003. Workshop Manual. Air Heaters. Air Top 2000 ST. Type Air Top 2000 ST B (petrol) Type Air Top 2000 ST D (diesel)

High Efficiency Boiler Range Technical Guide

HYDRONIC D5S/SC DIAGNOSTIC AND REPAIR MANUAL

For installation guide see reverse of book

Diesel Engine Driven Generators Page 1 of 6

Air conditioning, electrical testing

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Fault Finder. A Service Engineers. for Warm Air Heating. Publication No. ZZ April 2015

Frequently Asked Questions Generators

REMOVAL AND INSTALLATION

NAVIEN AMERICA INC FITCH AVENUE

Coolant heater. Thermo Top - Z/C additional heating system. Installation instructions. Volvo S60, Volvo V70, and Volvo S80 Beginning Model Year: 2000

Luft-Heizgeräte 03/2003. Workshop Manual. Water heaters. Thermo Top V. Type Thermo Top V (Petrol) Type Thermo Top V (Diesel)

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE CCA CCA MARINE MCA MCA DEEP CYCLE 17 55Ah 17 80Ah

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

PORTABLE AIR CONDITIONER

Factory owners must ensure the boiler is:

Laddomat Charging unit

ACTIVE.

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Air Top 2000 ST D (Diesel) Air Top 2000 ST B (Gasoline)

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

ELECTRIC CENTRAL HEATING FLOW BOILER

Oil and Coolant Circulating Heating System. Model - OCSM

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Air Top 3500 ST. Air Top 5000 ST. Workshop manual. Air heaters

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Operating instructions

E-gas Instant Gas Water Heaters

NISSAN FIGARO FAULT CODES AND DIAGNOSTICS

Zip Hydroboil Plus Cuts energy consumption dramatically

Water Heater MkII WH1302 / WH1302B INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

AIR CONDITIONERS ROOF TOP & UNDERBUNK INSPIRED BY COMFORT NEW RELEASE DOMETIC FRESHJET

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Pre-site Installation Instructions for Aga Electric Cooker Models Electric C Electric E

Heat Pumps for Swimming Pools

ALWAYS follow all Webasto installation and repair instructions and observe all warnings.

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

HEATER, AIR CONDITIONING AND VENTILATION

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Thermo 90 S Thermo 90 S-ADR. Thermo 90 ST Thermo 90 ST-ADR. Water heaters. Workshop manual. (Transport of hazardous goods)

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

San josé OWNER S MANUAL

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

UDSA - UDSBD unit heater

HERZ-Thermal Actuators

RedCore 1500 Infrared PTC Heater

Air Conditioning Sign-Off Sheet

Drayton Digistat +2RF/+3RF

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

AHE S SERVICE MANUAL

C18 ACERT Fire Pump Tier bkw/ rpm

How to choose a heat pump and use it wisely

INTEC Engineering GmbH Heating Solutions for the Marine Industry

Electric Flow Boiler

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

Baxi Combi 80e & 105e

User's Instructions. Alpha HE CB25/33 and HE SY25

MovinCool Office Pro Series. The Portable Spot Cooling Solution

COOLING SYSTEM Section Page

EC450 Power Control System

FT-100 Fire Training Fog Machine User Manual English

ECOCIAT. Domestic hot water heat recovery unit

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Cambridge Electric Infared Fireplace User Manual

3000W Power Inverter

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Transcription:

Frequently Asked Questions Air Top Diesel Heaters 2000STC, Evo 40 & Evo 55

Question 1 What power outputs are the heaters available in? There are 3 models 2kW, 4kW and 5.5kW Question 2 What voltage are the heaters available in? 12V and 24V DC Question 3 What are the dimensions of the heaters? AT 2000 STC 311 x 120 x 121mm (LxWxH) AT Evo 40 & 55 423 x 148 x 162mm (LxWxH) Question 4 How much diesel do the heaters use per hour? Depending on the heater size, between: 0.12L 0.24L per hour for the AT 2000STC 0.18L 0.49L per hour for the AT Evo 40 0.18L 0.67L per hour for the AT Evo 55 On average a heater needs 100ml diesel per hour, per kw 2

Question 5 I have a caravan, can I still fit a heater? Yes, Webasto can offer a separate 12L fuel tank for this application. The fuel tank is supplied with a quick connect coupling and sight glass. Question 6 How many outlets can be run off one heater unit? AT 2000STC up to 2 outlets AT Evo 40 and AT Evo 55 up to 6 outlets Question 7 What type of outlets are available? 60mm, 80mm, 90mm closeable vents, 45 degree and 90 degree louvers, as well as open vents (spider vents). Question 8 Are standard installation kits available? Based on our experience with manufacturers and aftermarket installers, we have developed comprehensive installation kits. These are available as 1 or 2 outlet kits.

Question 9 Can the heater be mounted outside of the vehicle? Yes, but the unit should be protected by installing it in a box. Question 10 Where can the heater be fitted inside the vehicle? Installation of the heater is determined by the amount of available space, usually under the bed or under the dinette area. Consideration of location must take into account good air flow around the heater. Question 11 Can an outlet be installed in the bathroom? Yes, a closeable vent is recommended Question 12 Does the heater need to be mounted on a flat surface? Yes, it should be mounted on a horizontal surface, which is achieved by using the available mounting bracket which is supplied in the heater kits. Question 13 Does the heater get hot? The heater itself will get hot directly around the warm air outlet, up to approx. 80 C 4

Question 14 How much power does the heater consume? The AT 2000 STC uses as little as 14 watts during normal operation (6-7 Amps at initial start phase, then 1-2 Amps during continuous running). Question 15 What type of controllers are available for the heaters? A standard rotary control is available. An optional programmable Multi Control, with features such as economical heating, boost heating, ventilation mode, high altitude mode & timer function is available at additional cost. Question 16 Can the heater be used whilst driving the vehicle? Yes, this is particularly useful for when people are travelling in the rear of a motorhome. It also ensures you arrive at your destination in a pre-warmed vehicle. Question 17 Can the heater be used while we are sleeping? Yes, the heaters are thermostatically controlled and safe to run while you are sleeping at night. The programmable Multi Control offers a Timer Function. 5

Question 18 Do the heaters generate any unpleasant odours? Thanks to continuous improvements in burner technology and fuel quality, exhaust odour is virtually unnoticeable as it is directed outside the vehicle. Question 19 Is there any exposure to a naked flame? No, the heater s use an electrical charged glow pin to initiate the combustion process, which is all contained within the units own combustion chamber. Question 20 Is it possible for the heater to flatten my house battery? As with any appliance, it is possible, but highly unlikely given the low current draw. Question 21 What size ducting is required? Depending on the heater, either 60mm for the AT 2000 STC and 90mm for the AT Evo 40 and AT Evo 55. 6

Question 22 What is the maximum length of ducting I can use? The ducting required is dependent on the length of the vehicle and the placement of the heater. There is no restriction on the length, however the more bends in the system, the less heat and air flow at the outlets. A larger heater should be selected if the duct length is too excessive. Question 23 Can the ducting be bent? Yes, it is a convoluted flexible duct specifically designed for high temperature applications. Acute bends should be avoided. Question 24 How is the heater connected to the fuel tank? In caravans the heater is connected directly to a 12L fuel tank that we can supply. With Motorhomes, fuel is taken from the vehicle s own fuel tank via a fuel standpipe. Some modern vehicles have an auxiliary spigot on the fuel tank sender unit that can be connected to the heaters fuel line. Question 25 Is it possible for the heater to drain all the fuel from the Motorhome s tank? Yes, but only if the fuel hasn't been sourced correctly from the vehicle s fuel tank. The recommendation is to cut the fuel standpipe so that it is 25mm from the bottom of the tank. 7

Question 26 Does the exhaust need to have a muffler? In an RV application, yes to minimise the inconvenience to fellow campers. This is supplied as a standard inclusion in our 1 and 2 outlet kits. Question 27 What is the maximum length of exhaust pipe that can be used? The standard length is 0.8 metres Question 28 Where should the exhaust pipe be terminated? Level to the outside edge of the vehicle, pointed down, away from the direction of travel and on the opposite side to the awning. Question 29 Will the heater run on Bio Diesel? No Question 30 Can the heater run whilst the vehicle is being refueled? No 8

Question 31 Can I use my own fuel line? No, the fuel line supplied is a specific dimension to ensure the correct amount of fuel is delivered to the combustion chamber. Question 32 Does the heater come with a fuel filter? Yes, it is standard in our 1 and 2 outlet kits. Question 33 Where should the fuel pump be mounted? Close to the fuel source so the pump can circulate fuel to the heater allowing for efficient delivery of the fuel. Question 34 How far away can the fuel pump be from the fuel tank? It is recommended the fuel pump be within 1 meter of the tank. Question 35 Where should I put the fuel filter? After the fuel source, before the fuel pump. 9

Question 36 Where should the combustion air be sourced from? Externally in a position where it is unlikely that the air inlet could be blocked and is splash proof. Question 37 Does the heater come with a temperature sensor? Yes, it is located on the return air side of the heater unit. Question 38 What electrical connections are required for the heater? A positive and negative to a reliable power supply directly to the house battery. An inline fuse is supplied in the harness. Question 39 Can the heater be connected to a circuit breaker? It is recommended to connect directly to the batteries via the fuse supplied in the kits to ensure that the heater cannot be switched off without going through its shutdown cycle. Question 40 If there is a fault with the heater, how do I diagnose the problem? On the Rotary Control, the fault code is displayed via the light in the center of the dial. For the programmable Multi Control, the fault code is displayed in the window of the controller. Consult your user manual to identify the displayed code.

Question 41 Is there any regular maintenance that must be carried out on the heater? If the heater is installed and operated correctly there should be no need to maintain the unit. However, as a preventative maintenance it is recommended that the heater should be run for 1 hour once every month regardless of the season. Question 42 After turning the heater ON, how long does it take for the heater to produce maximum heat? It depends on many variables. The combustion process for the AT 2000 STC takes 105 seconds. After this the heater will start to heat up the space. Question 43 After turning the heater OFF, how long does it take to shutdown? The fan will run for a period of time to cool down the heat exchanger. This will depend on how the heater has been running and what the return air temperature is. Question 44 Why do you have a temperature sensor on the return air side of the heater? This is positioned so that it measures the overall room temperature, not the temperature at the controller. 11

Question 45 Can I fit the controller anywhere inside the vehicle? Yes, as the controller does not contain a temperature sensor, its position has no influence on the heater performance (note that the supplied wire harness is 7m in length). Question 46 How do you maintain stable temperatures? Our heaters are designed to measure the return air temperature managed by the ECU, using step-less power modulation to ramp the power required up and down to maintain temperature. Question 47 What safety features are built into the heater? Safety features include: Under / Over voltage Overheat temperature sensor (in case of vent blockage) Heater lock out after 3 false attempt starts In case of an error (fault code) the fuel pump will stop operating to ensure the burner chamber is not flooded with fuel. Question 48 Where are Webasto heaters made? Our heaters are made in our factory in Germany. Question 49 Is the heater unit covered by warranty? Yes, the heater units come with a 2 year warranty. 12