KSR KELER Niveau-Messtechnik G 6949 Zwingenberg Germany Tel ++49 (0) 6 6-87- 0 Fax ++49 (0) 6 6-87 99 info@ksr-kuebler.com www.ksr-kuebler.com KLER FRNCE S.. 68700 Cernay KSR KELER (K) Level Measurement & Control Ltd. Corwen, Denbigshire L 9P KSR KELER (Scandinavia) 970 Hoersholm KSR KELER (Italy) Misura di Livello 400 rembate S.(G) KSR H&H Measurement V (benelux) 5 NE, Riel OOO KSR KELER RS (RS) 0948 Moskau KSR KELER (S) Level Control Products of merica Inc. Charlotte, NC 87 KSR KELER (SINGPORE) Level Measurement & Control Pte. Ltd. Singapore 608609 SHNGHI KSR KELER utomation Instruments Co. Ltd. Shanghai / China
pprovals Contents TEX 94/9/EC PED 97//EC Germany Technischer Überwachungsverein Südwestdeutschland e.v. IEx Institut für Sicherheitstechnik GmbH Physikalisch Technische undesanstalt PT undesamt für Wehrtechnik und eschaffung Germanischer Lloyd Netherlands KEM France Laboratoire Central des Industries Electriques ureau Veritas Denmark DEMKO Norway Det Norske Veritas Russia Gosgortechnadzor OGS Oil & Gas Safety GOST Permission to use Pattern pproval/ex S Factory Mutual Research Corporation KSR Magnetic Float Switches Description 4 pplications 5 Compass, Product range 6 Type code 7 KSR Magnetic Float Switches Stainless steel SS 6 Ti 8/ Stainless steel - adjustable 9/ Stainless steel, II /G EEx ia IIC T-T6 II D T80 C IP6X 0/ Stainless steel, II G EEx d IIC T6-T4 / Food industry design Stainless steel, una float 4/5 Magnetic mini float switches 6/7 ngular design, stainless steel 8 ngular design, PVC or Polypropylene 9 PVC, Polypropylene or PVDF 0- Stainless steel, ECTFE-coated 4/5 Special flange design 6 Suspended float design 7 Sanitary design 0 KSR ypass Float Switches luminium or ronze 8 Stainless steel 9 Contact protection measures Spherical floats Cylindrical floats Connection diagrams 4/5
KSR Magnetic Float Switches are used to control distinct levels of a liquid. They are based on the float principle with individual contacts for every level to be monitored. float with a built-in magnetic system actuates a small reed contact through the wall of the guide tube. Thus the switching operation is without direct contact to the liquid, free of wear and tear, and does not require any power supply. KSR Magnetic Float Switches are available with multiple switch points. Contact denomination always refers to rising level of the liquid: S - closing on rising level O - opening on rising level - change-over y using one float up to a maximum of switch points the switching behaviour is bistable i.e. the switching state will remain the same even when the liquid moves further up or down. Contacts are volt-free. Technical advantages The simple operating principle is suitable for a wide variety of applications. Suitable for virtually all liquids. Measurement of liquid levels independent of physical or chemical changes of the liquid, e.g. foam, conductivity, dielectric constant, S.G., pressure, vacuum, temperature, vapour, condensation, bubbles, boiling effects. niversal signal processing PLC Initiator circuit (NMR) Signal amplifiers/protection relays -point controls S-Interface available, Ex/non-Ex. Multiple switch points in one unit (up to 8). High repeatability of set points. Long service life. Suitable for rough environments. Interface and product level measurement possible at -S.G. 50 kg / m. Simple installation and commissioning, maintenance-free. pplication limits: T = -96 C to + 00 C P = vacuum to 00 bar S.G. 400 kg/m High availability of corrosion resistant materials for applications in all industries: Chemical, petrochemical, and pharmaceutical industry, liquid natural gas, off-shore, ship-building, power plants, manufacturing industry, water treatment, food and beverages. pplication specific designs available. Explosion-proof designs. Float switches are simple devices without certification according EN 5000/5.4. s such, they are allowed to be used in Ex-area Zone, on condition, that they work with a certified intrinsically safe circuit in protection class EEx ib or higher.
pplications PLC PLC KSR Magnetic Float Switches with multiple switch points ϑ PT00 ϑ PT00 Intrinsically safe Intrinsically safe KSR Magnetic Float Switches for high alarm (EEx i) Intrinsically safe relay e.g. KR 4 Ex Intrinsically safe relay e.g. KR 4 Ex Ex Safe Ex Safe Contact protection relay e.g. KR 0 Contact protection relay e.g. KR 4 KSR Magnetic Float Switches for -point control (min/max.)
Compass This page is intended to guide you through the product range of KSR KELER for Magnetic Float Switches. Please select connecting option and material and turn to the page referred to in the following table. Material Stainless steel Stainless steel PVC luminium SS 6 Ti SS 6 Ti PP ronze Process (.457) (.457) PVDF Thread Page Page SP /8" 8/4 0// SP /8" 9 adjustable SP /" 6 mini SP " 0 sanitary Thread Page Page Page SP /4" 8/4 0/ 0// SP " 9 adjustable SP /" 6 mini SP " Flange Page Page Page DN...PN.. 8/4 0/ 0// 9 adjustable 4 coated ngular Page Page design 8 9 ypass- Page Page Float Switches 9 8
Type Code Code st key nd key rd key Electrical connection Process connection Material process connection.../.../... - (none) - connection cable ER Mounting thread upwards (SP) V Stainless steel SS 6 Ti Terminal box luminium R Mounting thread downwards (SP) VE Stainless steel polished Terminal box Polypropylene ENPT Mounting thread upwards (NPT) VEC Stainless steel ECTFE-coated P Terminal box Polyester NPT Mounting thread downwards (NPT) VTF Stainless steel PTFE-lined VT Terminal box, with screw cap MR Dairy fitting acc. to DIN 85 T Titanium Stainless steel SS 6 Ti F Flange (DIN, NSI, JIS ) H Hastelloy DF Terminal box, flameproof FC Clamp-connection acc. to DIN 676 HC Hastelloy C luminium IS Sanitary nozzle (Ingoldstutzen) P PVC SC4 Coupler plug C 64--F-4P PP Polypropylene SC5 Coupler plug C 64--F-5P PF PVDF SC7 Coupler plug C 64-47-F-7P M rass flange OD 74 mm SH Coupler plug Harting HN 7 D K Oval flange, Polyamide SQ Coupler plug QICKON max.4-pin Size process connection.../.../...... Mounting thread size in inches... Threaded connection size DN 50 - DN 50.../ Flange nominal size.../ Flange pressure rating... Flange face DIN DN 50 - DN 00 PN 6 - PN 00 Standard Form C optional E,,F,N NSI "- 8" Class 50-600 Standard RF optional RTJ,FF,ST,SG JIS "(DN 50) - 8"(DN 00) 5 K- 6 K Standard RF optional RTJ,FF,ST,SG Clamp DN 5 - DN 00; "- 4" Guide tube material Contact function Optional code adder.../.../... V Stainless steel SS 6 Ti S Closing HT.. High temperature +50 C...+00 C VE Stainless steel electropolished O Opening TT.. Low temperature -0 C...-96 C VEC Stainless steel ECTFE-coated Change over VTF Stainless steel PTFE-lined H Increased hysteresis H Hastelloy PT00 Temperature probe PT 00 (-,- or 4-core) HC Hastelloy C..TH.. Temperature switch... C - closing or opening P PVC R... Current limitation using resistor.. Ohm PP Polypropylene N acc. to NMR DIN EN 60947-5-6 PF PVDF W... ngular design (V,P,PP) 4 Guide tube length OD Guide tube L.../... L.../ length in mm... OD in mm 5 Float design see page /.../....../ Material (code, st key)... Float OD in mm 6 Connection cable Cable material Optional adder.../....../ length in Meter - PVC grey SL Earth connection blue PVC blue SIL Silicone ÖL Ölflex Order example Connection Connection Guide tube material Guide tube Float Cable design / material size contact function length / OD length / material Code - - - 4-5 - 6 FV - 50/6/F - V S O - L950/ - V44 - - Switch function on rising level Switch point L = 905 mm Chance over Switch point = 400 mm Opening Switch point = 90 mm Closing
Stainless steel SS 6 Ti (.457) Schwimmer Magnetschalter Edelstahl.457 + + Edelstahl.457 una una Connection cable G G /8 /8 SW SW ERV-/8 ERV-/8 RV RV FV FV ERV-..."-V.-L.../..-V..-... RV-..."-V.-L.../V..-... FV-.../.../..-V.-L.../V..-... Electrical connection Cable PVC grey, PVC blue, Terminal box luminium 64 x 58 x 4 mm, with contact Silicone, Ölflex luminium 80 x 75 x 57 mm, or more contacts Option Polypropylene, Polyester, Stainless steel Process connection Mounting thread upwards Mounting thread downwards Mounting flange DIN DN50-DN00, PN6-PN00 SP /8" SP /" SP /" or SP " NSI "-8", Class 50-600 Guide tube - OD or 4 mm 8 mm or 4 mm 8 mm or 4 mm 8 mm Guide tube length max. 000 mm 6000 mm 000 mm 6000 mm 000 mm 6000 mm Float V44, V5, V6, V8 guide tube - OD or 4 mm V80, V98, V05, V0 guide tube - OD 8 mm Limit S.G. 85% Limit S.G. 50% see KSR Floats page / Nominal pressure Temperature range PVC / Ölflex cable -0 C... +80 C -0 C...+50 C standard Silicone cable -0 C...+50 C High temperature Optional code (HT..) +50 C...+00 C see page 4 Low temperature Optional code (TT..) -0 C...-96 C Switch function optional closing S, opening O or change-over SPDT - on rising level Number of contacts PVC cable 6 x S or O or 4 x 6 x S or O or 4 x Silicone cable x S or O or x Switch rating closing 0V C; 00V; 0V DC; 50W; 0.5 opening 0V C; 00V; 0V DC; 50W; 0.5 change-over 0V C; 40V; 0V DC; 0W; 0.5 ttention: Designs without earthing connection - use low voltage only e.g. contact protection relays (see catalogue 0) or external protective earth Orientation vertical ± 0 Ingress protection IP 65 Materials.445,.459, Titanium, Hastelloy and others available upon request
Stainless steel SS 6 Ti (.457) - adjustable Schwimmer Schwimmer Magnetschalter Magnetschalter Edelstahl Edelstahl.457, verstellbar.457, verstellbar to adjust loosen counter nut Connection cable WF 7 WF 7 to adjust loosen counter nut to adjust loosen counter nut WF 7 WF 7 WF 7 WF 7 4 SP / SP / 4 RV-/8 RV-/8 RV RV FV FV RV- /"-V.-L.../-V..-...-verst. RV-..."-V.-L.../-V..-verst. FV-.../.../..-V.-L.../-V..-verst. Electrical connection Cable PVC grey, PVC blue, Terminal box luminium 64 x 58 x 4 mm, with contact Silicone, Ölflex luminium 80 x 75 x 57 mm, or more contacts Option Polypropylene, Polyester, Stainless steel Process connection Mounting thread downwards Mounting thread downwards Mounting flange DIN DN50-DN00, PN6-PN00 SP /" SP /" or SP " NSI "-8", Class 50-600 Guide tube - OD Guide tube length max. Float mm 000 mm V44, V5, V6, V8 Limit S.G. 85% see KSR Floats page / Limit S.G. 50% Nominal pressure 5 bar Temperature range PVC- / Ölflex cable -0 C... +80 C -0 C...+50 C Silicone cable -0 C...+50 C Switch function optional closing S, opening O or change-over SPDT - on rising level Number of contacts PVC cable 6 x S or O or 4 x 6 x S or O or 4 x Silicone cable x S or O or x Switch rating closing 0V C; 00V; 0V DC; 50W; 0.5 opening 0V C; 00V; 0V DC; 50W; 0.5 change-over 0V C; 40V; 0V DC; 0W; 0.5 ttention: Designs without earthing connection - use low voltage only e.g. contact protection relays (see catalogue 0) or external protective earth Orientation vertical ± 0 Ingress protection IP 54 IP 65 Materials.445,.459, Titanium, Hastelloy and others available upon request
II G EEx ia IIC T-T6 KEM 0 TEX 05X II D T80 C IP6X Schwimmer Magnetschalter Schwimmer Magnetschalter CE Ex II G EEx Ia IIC CE T-T6 Ex II G KEM EEx 0 Ia TEX IIC T-T6 05X KEM 0 TEX 05X Process temperature Raised terminal box X < 60 C 0 mm X X X X < 5 C 60 mm < 80 C 80 mm 60 V-G 60 V-G 60 V-DN 60 V-DN Electrical connection 60-RV..."-V.-L.../..-V..-Ex Terminal box luminium 80 x 75 x 57 mm, Option: Polyester, Stainless steel 60-FV.../..-V.-L.../..-V..-Ex Process connection Mounting thread downwards Mounting flange SP " - SP " DIN DN50 - DN50, PN6 - PN64 NSI "-6", Class 50-600 Guide tube - OD mm or 4 mm 8 mm mm or 4 mm 8 mm Guide tube length max. 000 mm 6000 mm 000 mm 6000 mm Float V44, V5, V6, V8 guide tube OD mm and 4 mm V80, V98, V05, V0 guide tube OD 8 mm Limit S.G. 85% Limit S.G. 50% see KSR Floats page / Nominal pressure Temperature class T T4 T5 T6 Process temperature max. 80 C 0 C 95 C 80 C mbient temperature at terminal box max. 60 C 60 C 60 C 60 C Switch function optional closing S or opening O or change-over SPDT - on rising level Number of contacts 6 x S or O or 4 x Switch rating only for use in certified intrinsically safe circuits with max 6 V, Imax 00 m Orientation vertical ± 0 Ingress protection IP 65 Options /PT 00 = Temperature probe /PT 000 = Temperature probe /..TH. = Temperature switch... C - closing or opening /N = acc. to NMR DIN EN 60947-5-6 Materials.445, Titanium and Hastelloy upon request 0
CE II G EEx d IIC T6-T4 LCIE 0 TEX 654 X Stainless steel SS 6 Ti (.457) Schwimmer Magnetschalter Schwimmer Magnetschalter CE Ex II G EEx CE d IIC Ex T6-T4 II G EEx d IIC T6-T4 LCIE 0 TEX 654 LCIE X0 TEX 654 X NPT /" NPT /4" NPT /" NPT /4" NPT /" NPT /4" NPT /" NPT /4" L-DF-RV-...-V.-L.../..-... Electrical connection Terminal box luminium Option: Stainless steel L-DF-FV-.../.../..-V.-L.../..-... Process connection Mounting thread downwards Mounting flange SP /" - SP " DIN DN50 - DN00, PN6 - PN64 NSI "-8", Class 50-600 Guide tube - OD mm or 4 mm 8 mm mm or 4 mm 8 mm Guide tube length max. 000 mm 6000 mm 000 mm 6000 mm Float V44, V5, V6, V8 guide tube OD mm and 4 mm V80, V98, V05, V0 guide tube OD 8 mm Limit S.G. 85% Limit S.G. 50% see KSR Floats page / Nominal pressure Temperature class T4 T5 T6 Process temperature max. 0 C 95 C 80 C Switch function change-over SPDT - on rising level max. Number of contacts 4 x Switch rating change-over SPDT 0 V C, 40V;.0 0 V DC, 0 W; 0.5 Orientation vertical ± 0 Ingress protection IP 65
Food industry design - Stainless steel SS 6 L Schwimmer Magnetschalter Schwimmer Magnetschalter Nahrungsmittel Nahrungsmittel Dairy fitting acc. to DIN 85 Clamp connection acc. to DIN 676 MRV- MRV- FCV- FCV- MRV-...-VE.-L.../..-VE.. Electrical connection Terminal box luminium 64 x 58 x 4 mm, with contact luminium 80 x 75 x 57 mm, or more contacts Option Polypropylene, Polyester, Stainless steel FCV-...-VE.-L.../..-VE.. Process connection Dairy fitting acc. to DIN 85 Clamp-connection acc. to DIN 676 DN50 - DN50 DN5 DN00 or " - 4" Guide tube - OD Guide tube length max. mm, 4 mm or 8 mm 000 mm guide tube OD mm and 4 mm, 6000 mm guide tube OD 8 mm Float V44, V5, V6, V8 guide tube OD mm and 4 mm V80, V98, V05, V0 guide tube OD 8 mm Limit S.G. 85% Limit S.G. 50% see KSR Floats page / Nominal pressure Temperature range standard -0 C...+50 C High temperature (HT..) +50 C...+00 C see page Switch function optional closing S, opening O or change-over SPDT - on rising level Number of contacts 6 x S or O or 4 x Switch rating closing 0V C; 00V; 0V DC; 50W; 0.5 opening 0V C; 00V; 0V DC; 50W; 0.5 change-over 0V C; 40V; 0V DC; 0W; 0.5 ttention: Designs without earthing connection - use low voltage only e.g. contact protection relays (see catalogue 0) or external protective earth Orientation vertical ± 0 Ingress protection IP 65 Distance between contacts contacts contacts Float type min. min. float floats mm mm mm mm mm mm VE44 44 or 4 55 45 0 80 VE5 5 or 4 55 45 0 80 VE6 6 or 4 60 50 0 90 VE8 8 or 4 70 60 0 0 VE80 80 8 90 65 0 5 VE98 98 8 00 75 0 45 VE05 05 8 05 80 0 55 VE0 0 8 5 90 0 70 Connection diagrams page -
Schwimmer Schwimmer V Schwimmer V V Schwimmer Schwimmer V Schwimmer V V KSR Magnetic Float Switches Switchpoint dimensions Page 8/9/0 contact contacts contacts =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... L = L... =... =... =... L = L... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... L = L... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... =... 4 contacts 5 contacts 6 contacts L4 = L4... =... L = L... =... L4 = L4... =... L = L... =... L4 = L4... =... L = L... =... L5 = L5... =... L4 = L4... =... L = L... =... L4 = L4... =... L = L... =... L4 = L4... =... L = L... =... L5 = L5... =... L5 = L5... =... L6 = L6... =... L5 = L5... =... L4 = L4... =... L = L... =... L4 = L4... =... L = L... =... L6 = L6... =... L5 = L5... =... L6 = L6... =... L5 = L5... =... L4 = L4... =... L = L... =... Distance between contacts Float type contacts contacts min. min. float floats mm mm mm mm mm mm V44 44 or 4 55 45 0 80 V5 5 or 4 55 45 0 80 V6 6 or 4 60 50 0 90 V8 8 or 4 70 60 0 0 V80 80 8 90 65 0 5 V98 98 8 00 75 0 45 V05 05 8 05 80 0 55 V0 0 8 5 90 0 70 Connection diagrams page 4/5
Stainless steel SS 6 Ti (.457) - una float Schwimmer Schwimmer Magnetschalter Magnetschalter Edelstahl.457 Edelstahl +.457 + Edelstahl.457 Edelstahl una.457 una Connection cable SP /8 SP /8 /8 WF WF ERV-/8 ERV-/8 RV RV FV FV ERV- /8"-V.-L.../..-..-... RV-..."-V.-L.../..-.. FV-.../.../..-V.-L.../..-.. Electrical connection Cable PVC grey, PVC blue, Terminal box luminium, Polypropylene, Polyester, Stainless steel Silicone, Ölflex Process connection Mounting thread upwards Mounting thread downwards Mounting flange SP /8" SP ", SP /" or SP " DIN DN40-DN00, PN6-PN40 NSI /"- 4", Class 50-00 Guide tube - OD Guide tube length max. Float mm 000 mm 0, 40 Limit S.G. 85% Limit S.G. 50% see KSR Floats page / Nominal pressure Temperature range -0 C... +80 C Switch function optional closing S, opening O or change-over SPDT - on rising level Number of contacts PVC cable 6 x S or O or 4 x 6 x S or O or 4 x Silicone cable x S or O or x Switch rating closing 0V C; 00V; 0V DC; 50W; 0.5 opening 0V C; 00V; 0V DC; 50W; 0.5 change-over 0V C; 40V; 0V DC; 0W; 0.5 ttention: Designs without earthing connection - use low voltage only e.g. contact protection relays (see catalogue 0) or external protective earth Orientation vertical ± 0 Ingress protection IP 65 4
Schwimmer Schwimmer KSR Magnetic Float Switches Switchpoint dimensions Page 4 contact contacts contacts L =... L =... 4 contacts 5 contacts 6 contacts L4 =... L4 =... L =... L =... L5 =... L5 =... L4 =... L4 =... L =... L =... Distance between contacts Float type contacts contacts min. min. float floats mm mm mm mm mm mm 0 0 40 65 0 75 40 40 40 45 0 65 Connection diagrams page - L6 =... L6 =... L5 =... L5 =... L =... L4 =... L4 =... L =... Connection diagrams page 4/5 5
Stainless steel SS 6 Ti (.457) Mini-Schwimmer Magnetschalter Edelstahl.457 Terminal box Coupler plug SC4 Coupler plug SC5 Coupler plug SC7 Connection cable SP /8 WF 4 ERV-/8 RV SC4RV SC..RV ERV- /8"-V.-L.../8-..-... ERV- /8"-V.-L.../8-PP7-... ERV- /8"- V.-L.../8-V9/..-... Electrical connection Cable PVC grey, PVC blue, Silicone, Ölflex Optional Terminal box luminium 64 x 58 x 4 mm Coupler plug SC4 C 64--F-4P Coupler plug SC5 C 64--F-5P Coupler plug SC7 C 64-47-F-7P Process connection Mounting thread upwards SP /8" Option Mounting thread downwards SP /4" or SP " Guide tube - OD Guide tube length max. 8 mm 500 mm Float una Polypropylene Stainless steel, 5 PP7 V9/0,5 or V9/0, Limit S.G. 85% Limit S.G. 50% see KSR Floats page / Nominal pressure Temperature range -0 C... +60 C -0 C... +80 C -0 C... +00 C Switch function optional closing S, opening O or change-over SPDT - on rising level Number of contacts x S or O or x Switch rating closing 50V C; 0V; 0.5 50V DC; 5W; 0.5 opening 50V C; 0V; 0.5 50V DC; 5W; 0.5 change-over 8V C; 6V; 0.6 8V DC; W; 0. ttention: Designs without earthing connection - use low voltage only e.g. contact protection relays (see catalogue 0) or external protective earth Orientation vertical ± 0 Ingress protection IP 54 with optional terminal box or connecting plug IP 65 6
= = = = = = = = = Schwimmer Schwimmer Schwimmer Schwimmer PP7 Schwimmer PP7 KSR Magnetic Float Switches Schwimmer PP7 Schwimmer V9 Schwimmer V9 Switchpoint dimensions Page 6 Schwimmer V9 =... =... =... =... =... Float type.. Float type PP7 Float type V9/.. Connection diagrams contact contact contact Colour coding to IEC 757 =... contacts contacts contacts =... =... N N K K N switchpoint switchpoint =... switchpoints L =... L =... L =... contacts contacts contacts PVC cable L =... L =... L =... L =... L =... L =... L =... L =... L =... L =... L =... L =... L =... L =... L =... L =... L =... L =... Distance between contacts Float type contacts min. min. floats mm mm mm mm mm 8 5 40 45 5 5 8 5 5 5 PP7 7 8 5 5 50 V7 7 8 5 5 50 V9/0.5 9 8 5 5 50 V9/0. 9 8 5 5 50 PK L =... L =... L =... N Silicone cable K N switchpoints switchpoints L L 7
KSR Magnetic Float Switch ngular design - Stainless steel SS 6 Ti (.457) Schwimmer Schwimmer Magnetschalter Magnetschalter Edelstahl Edelstahl.457.457 Winkelausführung Winkelausführung SP SP WF WF ERV-/8 -W ERV-/8 -W RV- -W RV- -W FV- -W FV- -W ERV- /8"-W..V.-L.../-V..-... Electrical connection Cable PVC grey, PVC blue, Silicone, Ölflex Option Terminal box Process connection Mounting thread SP /8" Option Mounting thread SP /" or SP " Mounting flange acc. to DIN or NSI Guide tube - OD Guide tube length max. Float mm 000 mm V44, V5, V6, V8 Limit S.G. 85% Limit S.G. 50% see KSR Floats page / Nominal pressure Temperature range PVC and Ölflex cable -0 C... +80 C, Silicone cable -0 C... +50 C Switch function optional closing S, opening O or change-over SPDT - on rising level Number of contacts PVC cable 6 x S or O or 4 x, Silicone cable x S or O or x Switch rating closing 0V C; 00V; 0V DC: 50W; 0.5 opening 0V C; 00V; 0V DC: 50W; 0.5 change-over 0V C; 40V; 0V DC: 0W; 0.5 ttention: Designs without earthing connection - use low voltage only e.g. contact protection relays (see catalogue 0) or external protective earth Orientation vertical ± 0 Ingress protection IP 65 Distance between contacts Float W contacts contacts type mm mm min. mm min. mm min. mm float mm floats mm V44 44 or 4 75 45 80 0 80 V5 5 or 4 75 45 80 0 80 V6 6 or 4 80 50 80 0 90 V8 8 or 4 90 60 80 0 0 Connection diagrams page 4/5 8
ngular design - PVC or Polypropylene Schwimmer Schwimmer Magnetschalter Magnetschalter PVC/PP PVC/PP Winkelausführung Winkelausführung W=... W=... W=... W=... SP /8 SP WF /8 WF SP /8 SP WF /8 WF WF ERP-/8 -W-P ERP-/8 -W-P ERPP-/8 -W-PP ERPP-/8 -W-PP ERP- /8"-W..P.-L.../-P44-... Electrical connection Cable PVC grey, PVC blue, Silicone, Ölflex Process connection Mounting thread SP /8" Guide tube - OD Guide tube length max. mm 000 mm Float P44 PP44 Limit S.G. 85% Limit S.G. 50% see KSR Floats page / Nominal pressure Temperature range 0 C... +60 C -0 C... +80 C Switch function optional closing S, opening O or change-over SPDT - on rising level Number of contacts 4 x S or O or x Switch rating closing 0V C; 00V; 0V DC; 50W; 0.5 opening 0V C; 00V; 0V DC; 50W; 0.5 change-over 0V C; 40V; 0V DC; 0W; 0.5 Orientation vertical ± 0 Ingress protection IP 54 ERPP- /8"-W..PP.-L.../-PP44-... Distance between contacts W contacts contacts Float type min. min. min. float floats mm mm mm mm mm mm mm P44 44 80 40 70 50 80 PP44 44 80 40 70 50 80 Connection diagrams page 4/5 9
PVC, Polypropylene, PVDF Schwimmer Schwimmer Magnetschalter Magnetschalter PVC/PP/PVDF PVC/PP/PVDF ERP-/8 ERP-/8 Connection cable SP /8 SP SP /8 /8 WF WF WF PVC ERP- /8"-P.-L.../-P44-... RP-..."-P.-L.../-P44 FP-.../0-P.-L.../-P44 Polypropylene ERPP- /8"-PP.-L.../-PP44-... RPP-..."-PP.-L.../-PP44 FPP-.../0-PP.-L.../-PP44 PVDF ERPF- /8"-PF.-L.../-PF44-... RPF-..."-PF.-L.../-PF44 FPF-.../0-PF.-L.../-PF44 Electrical connection Cable PVC grey, PVC blue Terminal box Polypropylene 80 x 8 x 55 mm Ölflex Process connection Mounting thread upwards Mounting thread downwards Mounting flange SP /8" SP /" or SP " DIN DN50 DN00 PN0 Form NSI " - 4", Class 50 FF Guide tube - OD mm Guide tube length max. 500 mm Float PVC P44 Polypropylene PP44 PVDF PF44 Limit S.G. 85% Limit S.G. 50% see KSR Floats page / Nominal pressure Temperature range PVC 0 C... +60 C Polypropylene -0 C... +80 C PVDF -0 C... +00 C Switch function optional closing S, opening O or change-over SPDT - on rising level Number of contacts 4 x S or O (PP max.) or x (PP max.) Switch rating closing 0V C; 00V; 0V DC; 50W; 0.5 opening 0V C; 00V; 0V DC; 50W; 0.5 change-over 0V C; 40V; 0V DC; 0W; 0.5 Orientation vertical ± 0 Ingress protection IP 54 IP 65 0
PVC, Polypropylene, PVDF Schwimmer Schwimmer Magnetschalter Magnetschalter PVC/PP/PVDF PVC/PP/PVDF ERP-/ ERP-/ Connection cable M0 x,5 M0 M0 x,5 x,5 M0 x,5 M0 M0 x,5 x,5 4 SP / WF 7 4 4 SP SP / / WF WF 7 7 PVC ERP- /"-P.-L.../6-P55-... PRP-"-P.-L.../6-P55 PFP-.../0-P.-L.../6-P55 Polypropylene ERPP- /"-PP.-L.../6-PP55-... PRPP-"-PP.-L.../6-PP55 PFPP-.../0-PP.-L.../6-PP55 PVDF ERPF- /"-PF.-L.../6-PF55-... PRPF-"-PF.-L.../6-PF55 PFPF-.../0-PF.-L.../6-PF55 Electrical connection Cable PVC grey, PVC blue Terminal box Polyester 80 x 75 x 55 mm Ölflex Process connection Mounting thread upwards Mounting thread downwards Mounting flange SP /" SP " DIN DN65 DN5 PN0 Form NSI /" - 4", Class 50 FF Guide tube - OD 6 mm, reinforced with metal insert Guide tube length max. 000 mm Float PVC P55 Polypropylene PP55 PVDF PF55 Limit S.G. 85% Limit S.G. 50% see KSR Floats page / Nominal pressure Temperature range PVC 0 C... +60 C Polypropylene -0 C... +80 C PVDF -0 C... +00 C Switch function optional closing S, opening O or change-over SPDT - on rising level Number of contacts 6 x S or O or 4 x Switch rating closing 0V C; 00V; 0V DC; 50W; 0.5 opening 0V C; 00V; 0V DC; 50W; 0.5 change-over 0V C; 40V; 0V DC; 0W; 0.5 Orientation vertical ± 0 Ingress protection IP 65
PVC, Polypropylene, PVDF Schwimmer Magnetschalter Schwimmer Magnetschalter PVC/PP/PVDF PVC/PP/PVDF ERP- ERP- Connection cable 4 4 4 SP SP WF WF PVC ERP- " -P.-L.../0-P..-... PRP- " -P.-L.../0-P.. PFP-.../0-P.-L.../0-P.. Polypropylene ERPP- " -PP.-L.../0-PP..-... PRPP- " -PP.-L.../0-PP.. PFPP-.../0-PP.-L.../0-PP.. PVDF ERPF- " -PF.-L.../0-PF..-... PRPF- " -PF.-L.../0-PF.. PFPF-.../0-PF.-L.../0-PF.. Electrical connection Cable PVC grey, PVC blue, Terminal box Polyester 80 x 75 x 55 mm Ölflex Process connection Mounting thread upwards Mounting thread downwards Mounting flange SP " SP " DIN DN65 DN5 PN0 Form NSI /" - 5", Class 50 FF Guide tube - OD Guide tube length 0 mm, reinforced with metal insert max.5000 mm Float PVC P55/6 or P80 Polypropylene 55/6 or PP80 PVDF 55/6 or PF80 Limit S.G. 85% Limit S.G. 50%see KSR Floats page / Nominal pressure Temperature range PVC 0 C... +60 C Polypropylene -0 C... +80 C PVDF -0 C... +00 C Switch function optional closing S, opening O or change-over SPDT - on rising level Number of contacts 6 x S or O or 4 x Switch rating closing 0V C; 00V; 0V DC; 50W; 0.5 opening 0V C; 00V; 0V DC; 50W; 0.5 change-over 0V C; 40V; 0V DC; 0W; 0.5 Orientation vertical ± 0 Ingress protection IP 65
Schwimmer Schwimmer P KSR Magnetic Float Switches Switchpoint dimensions Page 0// contact contacts contacts =... =... =... L L =... =... =... =... 4 contacts 5 contacts 6 contacts =... =... =... =... =... =... L4 L4 =... =... L L =... =... L5 L5 =... =... L4 L4 =... =... L L =... =... L6 L6 =... =... L5 L5 =... =... L4 L4 =... =... L L =... =... Distance between contacts Float type contacts contacts min. min. float floats mm mm mm mm mm mm P44 PP44 44 50 40 50 80 PF44 44 55 55 50 00 P55 PP55 PF55 55 6 70 60 0 00 P55/6 PP55/6 PF55/6 55 0 80 70 0 0 P80 PP80 PF80 80 0 80 70 0 0 Connection diagrams page 4/5
Stainless steel SS 6 Ti (.457), ECTFE-coated Option: anti-static Schwimmer Magnetschalter Edelstahl E-CTFE-beschichtet FVEC- FVEC- FVEC-.../.../..-VEC.-L.../-VEC.. Electrical connection Terminal box luminium 64 x 58 x 4 mm, with contact luminium 80 x 75 x 57 mm, or more contacts Option Polypropylene, Polyester, Stainless steel FVEC-.../.../..-VEC.-L.../8-VEC.. Process connection Mounting flange DIN DN50 - DN00, PN6 PN40, NSI " - 8", Class 50-00 Guide tube - OD mm 8 mm Guide tube length max. 000 mm 4000 mm Float VEC45, VEC5, VEC6, VEC84 VEC8, VEC99, VEC06, VEC Limit S.G. 85% Limit S.G. 50% see KSR Floats page / Nominal pressure Temperature range depending on liquid Switch function optional closing S, opening O or change-over SPDT - on rising level Number of contacts x S or O or x 6 x S or O or 4 x Switch rating closing 0V C; 00V; 0V DC; 50W; 0.5 opening 0V C; 00V; 0V DC; 50W; 0.5 change-over 0V C; 40V; 0V DC; 0W; 0.5 ttention: Designs without earthing connection - use low voltage only e.g. contact protection relays (see catalogue 0) or external protective earth Orientation vertical ± 0 Ingress protection IP 65 4
Schwimmer E-CTFE Schwimmer E-CTFE KSR Magnetic Float Switches Switchpoint dimensions Page 4 contact contacts contacts......... =............ Impulse contact L L =...... L L =... =.................. Impulse contact Impulse contact 4 contacts 5 contacts 6 contacts L4 L4 =...... L L4 L4 =... =...... L... L =... L... =...... =............ Impulse contact Impulse contact Impulse contact L5 L5 =...... L4 L4 L5 L5 =...... =...... L4 =... L4 L... =... L... L =... L............... Impulse contact Impulse contact Impulse contact Impulse contact L6 L6 =...... L5 L6 L6 =... =...... L5... L5 =... L5 L4... =... L4... L4 =... L L4 =...... L... L =... L... =...... =............ Impulse contact Impulse contact Impulse contact Impulse contact Impulse contact Float type Distance between contacts min. min. contacts mm mm mm mm mm VEC45 45 55 55 50 VEC5 5 55 55 50 VEC6 6 60 60 50 VEC84 84 70 70 50 VEC8 8 8 90 75 50 VEC99 99 8 00 85 50 VEC06 06 8 05 90 50 VEC 8 5 00 50 Connection diagrams page 4/5 5
Special flange design - Stainless steel SS 6 Ti (.457) Schwimmer Magnetschalter Schwimmer Magnetschalter Sonderflansche Sonderflansche 75 75 5 K 5 K 45 5 OD OD40 45 5 50 6,5 45 5 OD OD40 OD OD44 45 5 OD OD44 5,5 5,5 50 74 60 74 60 6,5 55 80 55 80 SC..FM-V..- SC4FK-V..- SC..FM-V..- SC4FK-V..- SC4FP-V.-L.../-40 SC..FM-V..-L.../-V44 Electrical connection Coupler plug C64-F-4P Coupler plug C64--F-5P C64-47-F-7P Process connection Oval flange, Polyamide rass flange Guide tube - OD Guide tube length max. mm 000 mm Float 40 V44 Limit S.G. 85% Limit S.G. 50% see KSR Floats page / Nominal pressure Temperature range 0 C... +60 C -0 C...+80 C Switch function optional closing S, opening O or change-over SPDT - on rising level Number of contacts x S or O or x x S or O or x Switch rating closing 0V C; 00V; 0V DC; 50W; 0.5 opening 0V C; 00V; 0V DC; 50W; 0.5 change-over 0V C; 40V; 0V DC; 0W; 0.5 Orientation vertical ± 0 Ingress protection IP 65 Connection diagrams page 4/5 6
KSR Suspended Float Switches Stainless steel SS 6 Ti (.457) - una float Schwimmer Magnetschalter Hänge-Schwimmer Edelstahl.457, una Compression fitting SP / or SP " Connection cable Heat-shrink sleeve Spacer OD 44 mm 55 0 75 Spacer OD 44 mm OD OD 40 HV..-0-40 HV.-0-40-Öl Electrical connection Cable m Ölflex Process connection Compression fitting PG 9, Option: mounting thread SP /" or SP " Polypropylene Guide tube - OD mm Guide tube length 0 mm Float 40 Option: V44 Nominal pressure atmospheric Temperature range -0 C... +60 C Switch function optional closing S, opening O or change-over SPDT - on rising level Number of contacts Switch rating 48V C; 0V; 0.4 48V DC, 0W; 0. Orientation vertical Ingress protection IP 68 Connection diagrams page 4/5 7
KSR ypass Float Switches Chamber luminium or ronze ypass-niveauschalter luminium oder Rotguss / R 7,5 55 7,5 66 7,5 ~00 64 Terminal box Chamber Drain plug SP /4 / R R Chamber luminium lmg5 ronze Rg5 Nominal pressure (Chamber) max. bar max. 6 bar Process connection Distance centre-to-centre Electrical connection Compression fitting GE0-LR, Carbon steel, Zinc coated 55 mm Terminal box, luminium 64 x 58 x 4 mm Guide tube - OD mm Stainless steel SS 6 Ti (.457) Float V44 Limit S.G. 85% see KSR Floats page / Limit S.G. 50% Temperature range Switch function -0 C... +50 C change-over SPDT () Switch rating 0V C, 40V, 0V DC, 0W, 0.5 Orientation vertical ± 0 Ingress protection IP 65 8
KSR ypass Float Switches Chamber Stainless steel SS 6 Ti (.457) ypass-niveauschalter ypass-niveauschalter Edelstahl Edelstahl.457.457 7,5 M =... 55 7(95) 7,5 M =... 55 7(95) 50 50 OD 60, OD 60, Terminal box Chamber Welding stubs S... 60 M=... 70 79(0) Drain plug SP / SP / 60 M=... 70 79(0) Terminal box Chamber Welding stubs S... Drain plug SP / SP / 50 50OD 60, OD 60, -V -V -V TR -V TR Ingress protection Prozessanschl sse IP 65 -V...-...-M... Chamber Stainless steel SS 6 Ti (.457) Prozessanschl sse 6 x S Prozessanschl or O or 4 x sse depending on distance centre-to-centre M... Options process connection -V...-...-M...-TR Pressure Equipment Directive 97//EC Nominal pressure (Chamber) 0.9 bar 6 bar with process flange PN6 40 bar with process flange PN40 Process connection S... = welding stubs OD F.../.../... = flanges acc. to DIN or NSI GM.. = threaded stubs, female GN.. = threaded stubs, male Distance centre-to-centre M = 80 mm... 000 mm Electrical connection Terminal box luminium 64 x 58 x 4 mm, with contact luminium 80 x 75 x 57 mm, or more contacts Guide tube - OD mm or 4 mm Float V44 V5 Limit S.G. 85% see KSR Floats page / Limit S.G. 50% Temperature range standard -0 C... +50 C High temperature (HT..) +50 C...+00 C see page Switch function Number of contacts optional closing S, opening O or change-over SPDT - on rising level Switch rating closing 0V C; 00V; 0V DC; 50W; 0.5 opening 0V C; 00V; 0V DC; 50W; 0.5 change-over 0V C; 40V; 0V DC; 0W; 0.5 Orientation vertical ± 0 - V... -... M... -... Process connection Flange connection F / / Male thread GN Female thread GM Switch function 9
Sanitary design - Stainless steel SS 6 L Schwimmer Schwimmer Magnetschalter Pharma Pharma ERV-/8 ERV-/8 Connection cable WF WF 5 5 SP SP /8 /8 =... =... L=... L=... =... =... Impulse contact Impulse contact Impulse contact ERV- /8"-V.-L.../7-V80//..-... Electrical connection Cable PVC grey, PVC blue, Silicone, Ölflex Option Terminal box Process connection Mounting thread upwards SP /8" Option Mounting flange acc. to DIN or NSI Dairy fitting acc. to DIN 85 Clamp connection acc. to DIN 676 Sanitary nozzle (Ingoldstutzen) Guide tube - OD 7, mm Stainless steel SS 6 L (.445) or.459 - ground and polished Guide tube length max. 5000 mm Float V80//... Stainless steel SS 6 L (.445) or.459 - ground and polished Limit S.G. 85% 75 kg/m Limit S.G. 50% 0 kg/m Nominal pressure Temperature range Switch function Number of contacts 5 bar PVC and Ölflex cable -0 C... +80 C, Silicone cable -0 C... +50 C optional closing S, opening O or change-over SPDT - on rising level PVC cable 6 x S or O or 4 x, Silicone cable x S or O or x Switch rating closing 0V C; 00V; 0V DC; 50W; 0.5 opening 0V C; 00V; 0V DC; 50W; 0.5 change-over 0V C; 40V; 0V DC; 0W; 0.5 Orientation vertical ± 0 Ingress protection IP 65 ttention: Designs without earthing connection - use low voltage only e.g. contact protection relays (see catalogue 0) or external protective earth Distance between contacts Float type min. min. contacts mm mm mm mm mm V80/ 80 7, 90 85 50 Connection diagrams page 4/5 0
l l + 4 V DC C + SPS 4 V DC S R S C SPS KSR Magnetic Float Switches Contact protection measures + 0 V C S R S C Zeitrelais C Zeitrelais + 0 V C S R S To ensure reliable operation and highest possible service life, we recommend using one of the following circuits. S Inductive load C S C Current measurement with 4 V oscilloscope DC R E S C R E S R 4-0V C S R 4-0V C C S 4-0V C CR C R Inductive 4-0V load CSDC + S C + 4-50V DC S 4 + - 50V DC S 4 + - 50V DC 4-50V DCS R S + Current limitation with capacitive load S R e.g. PLC and cables >50m S C + 4 V DC 4 V DC S R S C SPS + CSPS 4 V DC S R S + S R SPS S C 4 + V DC S R S C + 0 V C SPS Zeitrelais C Current 0 V Climitation S with R S electronic timers + Zeit- Crelais 0 V C S R S Zeitrelais + S C 0 V C S Zeitrelais C R E 4 V DC S C R E RC-modules acc. to table Shunt diode e. g. N4007 R s = Ohm (47 Ohm with 0 V contacts) C =internal capacitance R s =0 Ohm (0 V C) C =internal capacitance I () 4 Example: C = 0.µF/4V DC 4 V DC without current limitation I () with current limitation 4 Protective RC-modules d Please use RC-modules d according to the table below. Rating of the switches and supply voltage will determine the type to be used. d For reed contacts 0-40V Capacitance Resistance Voltage Type 0. µf 00 Ohm 4V C /4 0. µf 0 Ohm 48V C /48 0. µf 470 Ohm 5V C /5 0. µf 500 Ohm 0V C /0 For reed contacts 40-00V Capacitance Resistance Voltage Type 0. µf 47 Ohm 4V C /4 0. µf 00 Ohm 48V C /48 0. µf 470 Ohm 5V C /5 d = OD6 mm - OD5 mm 0. µf 000 Ohm 0V C /0 I = 6 mm - 58 mm 00-0 R M 00 I not allowed allowed Others types might lead to destruction or lower service life of the reed contacts. 00 R M t ( s) -0 t ( s) 4 V DC R C M Remarks R M for high and low temperature design 4 V DC C R E Contact function optional closing (S) or opening (O) on rising level R max. number of contacts M 4 V DC, float per contact, distance - according float size Switching capacity closing or opening 48V C; 0V; 0.4 48V DC; 0W; 0. I () I () 4 I () 4 S R M R E I () 4 4-0 -0 t ( s) -0 t ( s)
Spherical floats OD C D D = Limit S.G. at 85% immersed float E E = Nominal S.G. at 50% immersed float OD Material Type C Max.operating Max.operating Weight Volume Limit S.G. Nominal S.G. Code 6 pressure temperature (D) 85% (E) 50% mm mm mm bar C g cm kg/m kg/m Stainless steel SS 6 Ti V9/0.5 9 8 9 6 00 7 8 977 660 (.457) V9/0. 9 8 9 5 00 8 8 069 87 V5 5 5 5 40 00 7 57 769 07 V6 6 6 5 00 5 0 597 05 V8 8 8 5 5 00 88 54 408 69 V80 80 76 5 00 5 98 679 55 V98 98 96 5 00 5 4 597 06 V05 05 0 5 00 40 59 5 907 V0 0 7 5 00 68 8 89 66 Titanium Grade (.705) T9 9 8 9 0 00 6 8 8 97 T5 5 5 5 5 00 4 57 707 0 T5/0,6 5 5 5 60 00 4 57 85 448 T5/0,8 5 5 5 80 00 5 57 060 80 T6 6 6 5 5 00 44 0 505 859 T8 8 8 5 5 00 60 54 78 47 T80 80 76 5 00 98 665 0 T98 98 96 5 00 78 4 495 84 T05 05 0 5 00 66 59 69 67 T0 0 7 5 00 7 8 9 560 Stainless steel SS 6 Ti VEC5 5 5 4 5 dep. on liquid 9 6 745 66 (.457) ECTFE-coated VEC6 6 6 4 5 dep. on liquid 55 09 59 005 VEC84 84 8 4 5 dep. on liquid 9 66 40 685 VEC8 8 77 5 dep. on liquid 8 0 78 0 VEC99 99 97 5 dep. on liquid 45 47 675 48 VEC06 06 04 5 dep. on liquid 78 57 6 076 VEC 8 5 dep. on liquid 0 794 459 78
Cylindrical floats OD C D D = Limit S.G. at 85% immersed float E E = Nominal S.G. at 50% immersed float OD Material Type C Max.operating Max.operating Weight Volume Limit S.G. Nominal S.G. Code 6 pressure temperature (D) 85% (E) 50% mm mm mm bar C g cm kg/m kg/m Stainless steel SS 6 Ti V7 7 0 6 00 8 787 8 (.457) V44 44 5 5 6 00 4 60 88 90 Titanium Grade (.705) T44 44 5 5 6 00 7 60 70 4 una 0 0 0 9 80 4 5 99 597 5 9 80 6 9 80 64 5 5 4 9 80 4 6 787 7 0 0 45 80 5 6 68 6 40 40 0 5 80 6 58 988 40/0 40 0 5 80 45 0 409 694 50 50 45 9 80 76 498 847 PVC P44 44 44 4 60 0 54 65 07 P55 55 54 60 70 0 798 57 P55/6 55 80 6 60 0 4 99 56 P55/70 55 70 60 80 40 674 45 P80 80 79 5 60 65 9 57 974 Polypropylene PP7 7 9 9 80 9 4 755 84 PP5 5 9 80 5 6 675 48 PP44 44 44 4 80 54 478 8 PP55 55 54 80 5 0 58 989 PP55/6 55 80 6 80 80 4 669 7 PP80 80 79 5 80 4 9 4 7 PVDF PF44 44 55 4 00 45 68 78 9 PF55 55 69 00 9 8 96 PF55/6 55 80 6 00 4 48 40 98 PF80 80 79 5 00 96 9 68 57 Stainless steel SS 6 Ti VEC45 45 5 4 6 dep. on liquid 44 66 78 9 (.457) ECTFE-coated
Connection diagrams Colour coding to IEC 757 PVC cable Silicone cable Terminal box max. temperature 90 C max. temperature 50 C max. temperature 60 C opening change-over opening change-over opening change-over or closing or closing or closing switchpoint switchpoint switchpoint switchpoint switchpoint switchpoint N N K N N K N N K K K N switchpoints YE GN N switchpoints K K N switchpoints YE GN N switchpoints switchpoints K K N 4 switchpoints YE GN N GN N YE PK switchpoints L PK switchpoints /RD RD WH N WH YE GN RD switchpoints L RD WH switchpoints N WH YE GN 4 5 RD 6 L 4 RD 5 WH 6 switchpoints WH K OG 4 switchpoints YE GN 4 switchpoints YE 4 GN 5 RD WH GN N YE PK L L4 N PK L 4 switchpoints /RD K RD WH GN N 4 YE 5 6 PK 7 8 L L4 N 6 7 PK 8 L 9 4 switchpoints WH K K VT RD WH GN N YE PK 5 switchpoints L L4 L5 VT /RD RD WH YE GN N PK L L4 5 switchpoints RD WH GN N 4 YE 5 6 PK 7 8 VT 9 CLER 0 L L4 L5 OG YE 4 GN 5 N 6 7 PK 8 9 RD 0 VT CLER L L4 6 switchpoints 6 switchpoints 4 /RD /RD K VT RD WH GN N YE PK L L4 L5 L6 RD WH GN N 4 YE 5 6 PK 7 8 VT 9 CLER 0 K OG L L4 L5 L6
Connection diagrams Colour coding to IEC 757 Coupler plug SC4 Coupler plug SC.. Coupler plug SH opening change-over SPDT opening change-over SPDT opening change-over SPDT or closing or closing or closing 5P and 7P 5P and 7P switchpoint switchpoint switchpoint switchpoint switchpoint switchpoint 5P and 7P 8 8 switchpoints switchpoints 7P switchpoints 4 4 5 6 7P switchpoints L 4 5 6 switchpoints 4 8 4 5 6 8 switchpoints L 4 5 6 8 switchpoints K K N 4 Levelcontact Temp switch GN N YE PK Levelcontact Temp switches KSR Magnetic Float Switches with temperature switches PVC or PVC cable Silicone cable or PVC or PVC cable Terminal box Silicone cable or Terminal box Silicone cable or Terminal box Terminal box 55 C 75 C Levelcontact Temp switches N WH YE GN 4 5 RD 6 55 C 75 C RD WH N 4 GN 5 Levelcontact Temp switch Levelcontact Temp switches /RD RD WH YE GN PK 55 C 75 C Levelcontact Temp switches WH K OG GN 4 N 5 6 PK 7 55 C 75 C Coupler plug SC4 Coupler plug SC.. or SH Coupler plug SC.. or SH Levelcontact Temp switch Levelcontact Temp switch Levelcontact Temp switch 4 4 5 5
KSR-KELER Niveau-Messtechnik G 6949 Zwingenberg Germany Tel ++ 49 (0) 6 6-87- 0 Fax ++ 49 (0) 6 6-87 99 www.ksr-kuebler.com info@ksr-kuebler.com 07/07.000 WR / ST Printed in Germany Subject to technical alterations