Structural fire design Eurocode 5-1.2 Timber structures



Similar documents
Fire safety in timber buildings

pren Eurocode 5 Design of timber structures Part 1-2: General rules Structural fire design Final Draft - October 2001 Stage 34 Clean version

Eurocode 5: Design of timber structures

LOAD-CARRYING CAPACITY OF AXIALLY LOADED RODS GLUED-IN PERPENDICULAR TO THE GRAIN

How To Make An Oriented Strand Board

WT WR. Lateral compression reinforcements EN Data sheet No Convincing advantages:

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

TECHNICAL RECOMMENDATION

European Technical Approval ETA-12/0500

SmartPly OSB3 SMARTPLY

FINAL DRAFT FprEN

Timber frame structures platform frame construction (part 1)

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

European Technical Assessment ETA-10/0153 of 10/06/2015

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

P.O. Box ZN Bleiswijk Brandpuntlaan Zuid NZ Bleiswijk The Netherlands

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

European Technical Approval ETA-11/0024

Technical Notes 3B - Brick Masonry Section Properties May 1993

Design Of Reinforced Concrete Structures ii Two-Way Slabs

Numerical modelling of shear connection between concrete slab and sheeting deck

Report Number BTC 17755F

Metsä Wood. Jussi Björman. R&D Engineer

Detailing of Reinforcment in Concrete Structures

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Eurocode 9: Design of aluminium structures

Rockwool Flexi Insulation Application Guide

Services Enclosures and Protected Shafts - Maintaining Compartmentation

BETONYP building boards. The modern way of living.

HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 7: Fire Engineering

9.3 Two-way Slabs (Part I)

Building Construction. Lightweight construction. Conventional Construction

Robert H. White, Research Wood Scientist, U.S. Forest Products Lab., Madison, WI, USA, Brian Kukay, Associate Professor of General

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F mail@oib.or.at

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

CHAPTER 6 CONSTRUCTION TYPES

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

EFFECTIVE BENDING CAPACITY OF DOWEL-TYPE FASTENERS

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

The University of Birmingham (Live System)

ICC-ES Evaluation Report

Master Panel 1000 W Wall

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

2.9 WINDOW & DOOR BUCKS

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

Mezzanine. Technical manual

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

Compression load testing straw bale walls. Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY.

Featuring TJ Rim Board and TimberStrand LSL

HUNTON BITUMEN IMPREGNATED BOARDS HUNTON BITROC SHEATHING BOARD

Timber Decks. Technical Note. March 2007

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

Building Systems by Stora Enso. Residential multi-storey buildings

European Technical Approval ETA-10/0153

Design guide. Part 1: Structural Design

Local buckling of plates made of high strength steel

European technical approval

Eurocode 4: Design of composite steel and concrete structures

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Optimum proportions for the design of suspension bridge

SIMPLE SAVER SYSTEM DESIGN MANUAL

AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels

HUS-HR, CR Screw anchor, stainless steel

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor

D5.1 Report on the needs to achieve improved fire protection as regards the implementation and development of the EN Eurocodes

ETAG 011 LIGHT COMPOSITE WOOD-BASED BEAMS AND COLUMNS

Aluminium systems profile selection

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

Chapter 6 ROOF-CEILING SYSTEMS

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

Formwork for Concrete

EN :2005. Wind actions

The International Journal Of Science & Technoledge (ISSN X)

POST AND FRAME STRUCTURES (Pole Barns)

P.O. Box ZN Bleiswijk Brandpuntlaan Zuid NZ Bleiswijk The Netherlands

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

HUS-H Screw Anchor. Technical data. Seismic design data. HUS-H Carbon steel screw anchor. HUS-H diameter 8, 10, 14. Seismic design data

PART 1 GENERAL 1.1 SECTION INCLUDES

EN DK NA:2007

EUROCODE 1 Actions on Building Structures

Chapter 2 Basis of design and materials

First 14-storey wood building in the world at Bergen in Norway Premier bâtiment en bois à 14 niveaux au monde à Bergen en Norvège

Discipline: Structural Issued

Master Panel 1000 R5 Roof

HexWeb CR III Corrosion Resistant Specification Grade Aluminum Honeycomb

H-Stud Area Separation Wall System

EN Timber Structures Bridges Eurocodes - Background & Applications 18 th 20 th of February 2008, Brussels

Design and Construction of Cantilevered Reinforced Concrete Structures

Preliminary steel concrete composite bridge design charts for Eurocodes

Design rules for bridges in Eurocode 3

AUTHORIZATION TO MARK

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

Transcription:

Background and Applications Brussels, 18-20 February 2008 Dissemination of information workshop 1 Structural fire design Eurocode 5-1.2 Timber structures Jochen Fornather Austrian Standards Institute jochen.fornather@on-norm.at

Background and Applications Scope of EN 1995-1-2 Brussels, 18-20 February 2008 Dissemination of information workshop 2 EN 1995-1-2 shows the design of timber structures for the accidental situation of fire exposure to be used in conjunction with EN 1995-1-1 and EN 1991-1-2. only identifies differences from, or supplements normal temperature design. deals only with passive methods of fire protection applies to building structures with loadbearing function and/or separating function

Background and Applications Design procedure (1) Brussels, 18-20 February 2008 Dissemination of information workshop 3

Background and Applications Design procedure (2) Brussels, 18-20 February 2008 Dissemination of information workshop 4 Annex A: Charring rates and charring depths

Background and Applications Basis of design (1) Brussels, 18-20 February 2008 Dissemination of information workshop 5 Basic requirements mechanical resistance fire compartmentation deformation criteria Requirements (R, E, I) concerning nominal fire exposure parametric fire exposure same as EN 1991-1-2 Actions see EN 1991-1-2 emissivity coefficient of wood surfaces: e = 0,8

Background and Applications Basis of design (2) Brussels, 18-20 February 2008 Dissemination of information workshop 6 Design values of material properties and resistances

Background and Applications Basis of design (2) Brussels, 18-20 February 2008 Dissemination of information workshop 7 Design values of material properties and resistances

Background and Applications Basis of design (3) Brussels, 18-20 February 2008 Dissemination of information workshop 8 Verification methods

Background and Applications Material properties Brussels, 18-20 February 2008 Dissemination of information workshop 9 Mechanical properties simplified methods for cross section and timber frame members in wall and floor assemblies completely filled with insulation advanced calculation methods. Thermal properties Charring (depth) for all surfaces of wood and wood-based panels directly exposed to fire, for surfaces initially protected from exposure and charring occurs during the relevant time of fire exposure.

Background and Applications Material properties: Charring (1) Brussels, 18-20 February 2008 Dissemination of information workshop 10 Surfaces unprotected throughout the time of fire exposure one-dimensional charring d char,0 notional charring

Background and Applications Material properties: Charring (2) Brussels, 18-20 February 2008 Dissemination of information workshop 11

Background and Applications Material properties: Charring (3) Brussels, 18-20 February 2008 Dissemination of information workshop 12 Charring for panels with other densities than ρ = 450 kg/m 3 and smaller thickness h p = 20 mm Example: OSB panel: ρ k = 700 kg/m³ h p = 20 mm ß o,ρ,t = 0,72 mm/min h p = 12 mm ß o,ρ,t = 0,93 mm/min

Background and Applications Material properties: Charring (4) Brussels, 18-20 February 2008 Dissemination of information workshop 13 Surfaces of beams and columns initially protected from fire exposure the start of charring is delayed until time t ch ; charring may commence prior to failure of the fire protection, but at a lower rate than the described charring rates until failure time t f of the fire protection; after failure time t f of the fire protection, the charring rate is increased above the shown values until the time t a described below; at the time t a when the charring depth equals either the charring depth of the same member without fire protection or 25 mm whichever is the lesser, the charring rate reverts to the described value.

Background and Applications Material properties: Charring (5) Brussels, 18-20 February 2008 Dissemination of information workshop 14 Surfaces of beams and columns initially protected from fire exposure

Background and Applications Material properties: Charring (6) Brussels, 18-20 February 2008 Dissemination of information workshop 15 Surfaces of beams and columns initially protected from fire exposure

Background and Applications Design procedures for mechanical resistance Brussels, 18-20 February 2008 Dissemination of information workshop 16 Simplified rules for determining cross-sectional properties - Reduced cross-section method k mod,fi = 1,0 k 0 : unprotected surface k 0 : intial protected surface

Background and Applications Design procedures for mechanical resistance Brussels, 18-20 February 2008 Dissemination of information workshop 17 Simplified rules for determining cross-sectional properties - Reduced properties method k mod,fi = f (ρ/a r and strength, stiffness) apply only to rectangular cross-sections of softwood exposed to fire on three or four sides and round cross-sections exposed along their whole perimeter. k mod,fi (t equal or greater 20 min):

Background and Applications Design procedures for mechanical resistance Brussels, 18-20 February 2008 Dissemination of information workshop 18 Simplified rules for analysis of structural members and components General Compression perpendicular to the grain may be disregarded. Shear may be disregarded in rectangular and circular crosssections. Beams, columns bracing fails should be considered Mechanically jointed members reduction in slip moduli in the fire situation shall be taken into account Bracings

Background and Applications Design procedures for mechanical resistance Brussels, 18-20 February 2008 Dissemination of information workshop 19 Advanced calculation methods for determination of the mechanical resistance and the separating function shall provide a realistic analysis of structures exposed to fire, based on fundamental physical behaviour to lead to a reliable approximation of the expected behaviour of the relevant structural component under fire conditions.

Background and Applications Design procedures for wall and floor assemblies Brussels, 18-20 February 2008 Dissemination of information workshop 20 Analysis of load-bearing function shall be designed for fire exposure on both sides at the same time. Analysis of separating function take into account the contributions of different material components and their position in the assembly.

Background and Applications Connections (1) Brussels, 18-20 February 2008 Dissemination of information workshop 21 applies to connections between members under standard fire exposure, for fire resistances not exceeding 60 min. Connections with side members of wood Simplified rules - unprotected connections

Background and Applications Connections (2) Brussels, 18-20 February 2008 Dissemination of information workshop 22 Connections with side members of wood Simplified rules - unprotected connections greater t dfi is possible (not more than 30 min) by increasing the following dimensions by a fi : the thickness of side members, the width of the side members, the end and edge distance to fasteners. k flux = 1,5

Background and Applications Connections (3) Brussels, 18-20 February 2008 Dissemination of information workshop 23 Connections with side members of wood Simplified rules - protected connections

Background and Applications Connections (4) Brussels, 18-20 February 2008 Dissemination of information workshop 24 Connections with side members of wood Additional rules for connections with internal steel plates

Background and Applications Connections (5) Brussels, 18-20 February 2008 Dissemination of information workshop 25 Connections with side members of wood Reduced load method Unprotected wood Protected wood

Background and Applications Connections (6) Brussels, 18-20 February 2008 Dissemination of information workshop 26 Connections with external steel plates unprotected protected Simplified rules for axially loaded screws design resistance of the screws conversion factor η

Background and Applications Detailing Brussels, 18-20 February 2008 Dissemination of information workshop 27 Walls and floors Dimensions and spacings Detailing of panel connections Insulation Other elements

Background and Applications Brussels, 18-20 February 2008 Dissemination of information workshop 28 Thank you very much for your attention! Contact: jochen.fornather@on-norm.at