ETHOS 70-130 WALL MOUNTED CONDENSING BOILERS

Similar documents
PRESSURISATION UNITS EXPANSION VESSELS ELECTRONIC FILLING DEVICE (EFD) MAXI MAXI PLUS EXPANSION VESSELS

Continuous flow direct water heating for potable hot water

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

HEAVY DUTY STORAGE GAS

Apartment and Communal Heating Solutions

Working towards a cleaner future. 30 to 4000kW. Condensing Aluminium 30 to 600kW. Condensing Stainless Steel 50 to 160kW

Blowdown vessels Meeting the requirements of HSE PM60

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Electric Flow Boiler

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

Gas Condensing Boilers

GAS HEATING IN COMMERCIAL PREMISES

ThermoStar Refrigeration Air Dryers

High-efficient gas boiler CompactGas

ThermoSorb Desiccant Dryers

ferroli Boiler Replacement Optimax HE- Modena HE

INSTANTANEOUS GAS FIRED

ECOCIAT. Domestic hot water heat recovery unit

Daikin Altherma Hybrid Heat Pump

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Product Overview Benefits

Operating instructions

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Thermo Siphon Solar Systems

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

building engineering services association specification for: Domestic Heating

The natural ombination

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

Daikin Altherma Hybrid Heat Pump

Laddomat Charging unit

A BIG STEP IN REDUCING YOUR CARBON FOOTPRINT.

Solar hot water systems that give energy efficiency a whole new meaning

Operating instructions

Energy Saving Fact Sheet Boilers

Kompressoren. Adsorption Dryer AD

ELECTRIC CENTRAL HEATING FLOW BOILER

Conlift1, Conlift2, Conlift2 ph+

Daikin Altherma. hybrid heat pump. The natural combination

Commercial Hot Water. Make a difference...

Daikin Altherma Hybrid Heat Pump

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Rotary screw compressors kw 5,5 7, , bar MODULO

Pipe Sizing for Commercial and Industrial Natural Gas at Operating Pressures 75 mbar

Daikin Altherma hybrid heat pump. The natural combination

MFP14, MFP14S and MFP14SS Automatic Pumps

PART 11: START-UP PROCEDURES FOR THE INSTALLER

Link-Up. Solid Fuel Association Guide to Central Heating.

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

Description of functions

For installation guide see reverse of book

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Natural geothermal energy.

Vaillant s plain English guide to. simple, concise and precise

FLEXCON EXPANSION VESSELS. Flamco FLEXCON Flexcon. Expansion vessels FLEXCON FLEXCON M. Flamco FLEXCON V-B.

FIELD TESTS OF FUEL EFFICIENCY MAGNETS J A CRABB JULY 1997 SWEEG REPORT 80

Gas Boilers - Commercial

Data sheet ECC 12 and 22

A guide to using variable-speed drives and motors in swimming pool halls


Advances in Gas Cooler Design and the New Gas Cooler Product Selector

Heating with wood chips and pellets

Stove-boiler for solid fuels KW Directions for use and assembling

COMMERCIAL REPORT / STOCK CONDITION SURVEY. Sydenham Hill Estate Sydenham Hill London SE 23

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Session 2: Hot Water Supply

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

SF15K SF05KSS, SF10KSS

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Typical condensing boilers can have an efficiency rating of 89% and up, which is 25% more efficient than a non-condensing boiler.

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Worcester GB162 wall mounted gas-fired condensing boiler series

Mikrofill Ethos Condensing combination boiler

Commercial Boiler Systems and Controls

User manual and Installation instructions

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

OPTIONS. for. Replacing Boiler Plant. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

Refrigeration Compressed Air Dryer Buran Ultrapulse

Morco House Riverview Road Beverley HU17 0LD

User's Instructions. Alpha HE CB25/33 and HE SY25

ECOplus Solar Cylinder

Direct Fresh Air Free Cooling of Data Centres

Quantifying the energy and carbon effects of water saving summary report

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Micro cogeneration. Affordable, efficient and innovative

Direct steam injection humidifiers

Frequently Asked Questions

Solar Hot Water Heaters

State of the Art Energy Efficient Data Centre Air Conditioning

Sizing and Selection of Hot Water Generating Plant. Presentation by: Rob Larner & David Dutch

Technical data. Danfoss DHP-A

UDSA - UDSBD unit heater

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Power consumption (kw)

Transcription:

ETHOS 70-130 WALL MOUNTED CONDENSING BOILERS

INSPIRED EFFICIENCY Mikrofill Systems Ltd is a Midlands based British engineering company which specialises in the design and manufacture of high quality products for the commercial heating market. Renowned for developing innovative products, the company has built its success on quality, reliability and outstanding customer service. As an established market leader and as one of the fastest growing companies in this sector, Mikrofill now manufactures over 70% of its range at its headquarters based in Worcestershire. The company s rapidly expanding range of products includes gas fired condensing boilers, domestic hot water generators and the well-established Mikrofill Electronic Filling Device., Inspired Efficiency, the latest creation by Mikrofill, consists of a revolutionary range of wall-mounted gas fired condensing boilers, which offer individual outputs up to 130 KW and multiple outputs up to 780 KW. The range has been developed to meet today s UK commercial needs of high output, ease of installation, optimum efficiency, ultra low greenhouse gas emissions and low running costs, all wrapped into a compact and elegant design. This brochure has been designed to enable you to specify boiler with confidence. If you require any further information see Mikrofill.com or contact our technical department. 2 70-130 Wall Mounted Condensing s

Energy efficiency and the environment a top priority! Mikrofill is committed to ensuring that all of its products are geared towards energy efficiency and always satisfy and exceed the most stringent environmental requirements. This is why all the boilers are designed to produce outstanding efficiencies and ultra low greenhouse gas emissions. how you could benefit! The range has been purposely designed for the UK market and all boilers offer the following benefits: High efficiency (108% nett) Ultra low greenhouse gas emissions Very wide modulation range (7:1) ensures very high seasonal efficiency (>95%) Quality stainless steel heat exchangers and pipework Comprehensive control package as standard Integral shunt pump Sealed air system ensures very low noise emissions (<48db) Compact design Single, twin or concentric flue pipe options British design and manufacture MIKROFILL ETHOS BOILERS 70 90 130 3 70-130 Wall Mounted Condensing s

APPLICATIONS SYSTEM 1 ONE BOILER ONE HEATING CIRCUIT System 1 External pump module required EPM 1 DOC Condense Waste Mains Cold Water Supply EFD Expansion Vessel Service Valve LSV DOC Air and Dirt Seperator LOW LOSS HEADERS We strongly recommend the use of low loss headers with all of our boilers, single or multiple. The low loss headers serve several important functions and are particularly effective where new boilers are installed into existing systems. They allow correct design flow rate through the boiler(s), whilst ensuring stable mix flow temperatures, which assists in r control, boile furthermore the modern boiler plant can operate at its optimum temperature differential irrespective of the main system temper ature differential. Additional protection can be afforded to the system by the installation of an air and dirt separator, particularly advisable r use fo in older systems, but recommended for all installations. The low loss header can also be used as a connection manifold for expansion sel, ves filling devices and control sensors. Due to the lower water velocity, (around 0.5 l/s) the low loss header also allows debris to precip itate out, thus further protecting the system. SYSTEM 2 ONE BOILER, TWO HEATING CIRCUITS ONE DHW CIRCUIT System 2 Zone Controller required EC1 HWS Secondary Flow Rapide Extreme HWS Secondary Return Condense Waste Mains Cold Water Supply EFD Expansion Vessel Service Valve LSV DOC Air and Dirt Seperator 4 70-130 Wall Mounted Condensing s

SYSTEM 3 TWO BOILERS ONE HEATING CIRCUIT System 3 Cascade controller required EC2 Condense Waste Mains Cold Water Supply EFD Expansion Vessel Service Valve LSV DOC Air and Dirt Seperator LOW LOSS HEADER SELECTION CHART Output kw Model Diameter Main Auxillary mm Connections Connections < <150 <300 <450 <750 <0 LL50 LL65 LL LL125 LL150 LL200 50 65 125 150 200 4x 11/4 BSP 4x2 BSP 4x2 BSP 4x DN 65 4x DN 80 4x DN 80 2x1 & 2x1/2 2x1 & 2x1/2 2x1 & 2x1/2 2x1 & 2x1/2 2x1 & 2x1/2 2x1 & 2x1/2 SYSTEM 4 System 4 Cascade controller required EC2 HWS Secondary Flow Rapide Extreme HWS Secondary Return Condense Waste Mains Cold Water Supply EFD Expansion Vessel Service Valve LSV DOC Air and Dirt Seperator 5 70-130 Wall Mounted Condensing s

SYSTEM 5 THREE BOILERS, ONE HEATING CIRCUIT ONE DHW CIRCUIT System 5 Cascade controller required EC3 HWS Secondary Flow Rapide Extreme HWS Secondary Return Condense Waste Mains Cold Water Supply EFD Expansion Vessel Service Valve LSV DOC Air and Dirt Seperator FILLING AND PRESSURISING THE SYSTEM The filling and pressure management of the hydraulic system is essential to the reliability and efficiency of the whole system, and must be by a method approved by the Water Regulation Advisory Service (WRAS). Heating applications other than single occupancy dwellings ie domestic housing, are considered to Fluid risk category 4 and as such can only be filled from the cold water supply by way of a back flow prevention devise approved for category 4. A traditional filling loop is not acceptable and is illegal. Systems with outputs in excess of 60 Kw will also require an automatic pressurisation unit to maintain and monitor the water pressure within the system ( BS6644). The above requirements can be satisfied by the use of an RPZ valve to fill the system, which requires annual service and inspection by an authorised body, a traditional pressurisation unit can be used to maintain and monitor the water pressure, a far superior alternative is the market leading MIKROFILL EFD unit, the only WRAS approved backflow preventor that can both fill any size system from empty, manage the pressure thereafter and offers many extra features including Flood protection. See our technical literature MSL 1/2008 SYSTEM 6 FOUR BOILERS, ONE HEATING CIRCUIT ONE DHW CIRCUIT System 6 Cascade controller required EC4 HWS Secondary Flow Rapide Extreme HWS Secondary Return Condense Waste EFD LSV Air and Dirt Seperator Mains Cold Water Supply Expansion Vessel Service Valve These schematics are only a selection of the many design possibilities, for systems up to 16 boilers or for further information contact the Mikrofill technical department 6 70-130 Wall Mounted Condensing s

BOILER MANAGEMENT SYSTEMS The range of condensing boilers incorporate the very latest control technology, and standard boiler features include ; SINGLE BOILER Frost protection Seven day time clock with night set back 12 month holiday programming External heating zone timed control Domestic Hot Water zone timed control Weather compensation Optimised start Remote alarm facility Remote room control Solar compatibility To ease installation some of the remote controls are available in wireless format. For most single boiler applications no other external controls will be required MULTIPLE BOILERS It is accepted as best practise to sequence (cascade) multiple boiler applications to maximise plant efficiency by closely tching maboiler output to system demand. Cascade units developed for standard non condensing boilers were relatively simple step controllers, times have now changed and the cascade controller is required to perform many more tasks, it still has to balance output to load t in, bu such a way as to keep the boilers in condensing mode as long as possible, the cascade controller becomes the prime mover of the em. syst The Mikrofill Cascade unit communicates digitally with each boiler and allows levels of control previously not available with any system, these features include Condensing mode optimisation Frost protection Seven day timeclock with night setback 12 Month holiday programming Up to 4 external heating timed zones Domestic Hot water timed zones Weather compensation Optimised Start Remote alarm facility Remote room/zone control Solar compatibility Biomass compatibility Control of up to 16 boiler units Equalised operating times for each boiler Accepts mixed boiler outputs The Mikrofill Cascade unit can recognise each boiler and download information ie output, turndown ratio and boiler gs settin and thus optimising the operation. To ease installation each boiler is factory set to match the Cascade Controller (when ordered ogether) t this drastically reduces installation and commissioning on site, and ensures the highest possible boiler efficiency. 7 70-130 Wall Mounted Condensing s

FLUE APPLICATIONS The range of boilers is approved for use with both open flued and room sealed type flue systems and as such are ble suita for most applications, please see the flue resistance charts. Flue components are readily available, including standard horizontal ertical and sets, v for information on multiple boiler applications please contact the Mikrofill Technical Dept. Care should be taken when siting the flue outlet, as all condensing boilers produce water vapour in the form of pluming which could cause a nuisance. All flue installations must comply with the Clean ir Act. A The Flue resistance table By using either concentric or the 2 pipe system, different flue lengths can be achieved. In case a concentric system is ts used, length i should not exceed 12 metres. C oncentric Flue System mm Resistance system (Pa) Resistance system (Pa) Part VerticalTerminal HorizontalTerminal Straight pipe/m 45º bend 90º bend VerticalTerminal HorizontalTerminal Straight pipe/m 45º bend 90º bend 80/125 80/125 80/125 80/125 80/125 /150 /150 /150 /150 /150 70 65 79.7 9.3 12.1 14.6 90 72.6 70 7.3 10.1 21.3 94.1 90.7 9.8 13.2 29.4 130 143.4 138.3 14.5 19.9 42.7 Two Pipe System Air Inlet Part Straight pipe/m 80 45º bend R=0,5D 80 6.8 90º bend R=1,0D 80 8.1 Flue Gas Outlet Vertical terminal 80 36 Horizontal terminal 80 19 Straight pipe/m 80 8.9 45º bend R=0,5D 80 12.4 90º bend R=1,0D 80 14.7 Air Inlet Part Straight pipe/m 1.7 2.4 3.4 45º bend R=0,5D 1.9 2.7 3.8 90º bend R=1,0D 8.4 11.7 16.6 Flue Gas Outlet Vertical terminal 29 35 42 Horizontal terminal 12 18 25 Straight pipe/m 3.1 4.0 6.1 45º bend R=0,5D 3.6 4.5 7.0 90º bend R=1,0D 15.4 19.5 30.2 4.9 Table 3 Flue discharge resistance Example of calculation - type: 70 Concentric pipe 80/125mm vertical 3m + horizontal 1m = total 4m concentric straight pipe 1 x Concentric 90º bend / 2 x Concentric 45º bend / Vertical terminal 80/125 Resistance Concentric pipe 80/125: 3m 3 x 9.3 27.9 Pa Concentric 90º bends: 1 pieces 1 x 14.7 14.7 Pa Concentric 45º bends: 2 pieces 2 x 12.1 24.2 Pa Vertical terminal 80/125* 65 Pa Total Resistance 138.6 Pa Total resistance is 138.6 Pa, so the boiler output is not changed by the resistance (lower than 140 Pa) and total concentric length is less than the maximum allowed 12 metres. * Vertical terminal includes 1 metre length 8 70-130 Wall Mounted Condensing s

VENTILATION The ventilation requirements for the range of boilers is dependant on the type of flue system used, reference should be made to BS 5440 Pt 2 and to BS 6644, but for detailed information on specific applications contact the Mikrofill technical dept.. Whereas no purpose designed ventilation is required in room sealed applications there is a requirement for ventilation into the boiler room or enclosure to ensure that the ambient temperature does not become excessive, again refer to BS 6644. boilers are only suitable for installation into sealed systems WATER QUALITY Upon installation of a new boiler the whole system should be thoroughly flushed, when connecting new boilers to existing systems then a power flush may be advisable. All boilers incorporate stainless steel heat exchangers which are extremely resistant to corrosion and remain chemically inert when exposed to most water borne contaminants, however the rest of the system will almost certainly contain materials which can oxidise and produce debris which may find its way into the heat exchanger and cause problems. It is strongly recommended that a method of mechanical filtration is installed into the system and that the water hardness is between 8 to 12 grams of calcium carbonate per litres of system water with a ph of between 7 and 8. If in any doubt about the water quality, please contact a water treatment specialist or Mikrofill Technical Dept. 9 70-130 Wall Mounted Condensing s

DIMENSIONS T ype B1 mm B2 mm D mm D1 mm 70 120 260 80 80 G R 3 4" R 3 4" R 3 4" R 3 4" L mm L1 mm 475 90 W R 1 1 4" R 1 1 4" R 1 1 4 R 1 1 4 90 140 260 475 90 (We reserve the right to make changes without prior noti cation)the data may deviate slightly due to fabrication tolerances. 140 260 660 90 130 140 260 660 90 EXTERNAL CONNECTION DIAGRAM (Schematic) 10 70-130Wall Mounted Condensing s

TECHNICAL DATA Dimensions (HxW xd) mm 900x 520x 475 900x 520x 660 Model W ater contentof appliance W eight (empty) Flow/return connections Gas connection Flue connection Air supply connection Concentric (optional) Power consumption Electrical supply Frequency Fuse protection Maximum fan speed Minimum fan speed litre kg BSP BSP mm mm mm W V Hz A RPM RPM 70 7 56 1 1/4 3/4 80 80 80/125 230 230 50 6 6500 0 90 8,8 66 1 1/4 3/4 /150 255 230 50 6 6500 0 10,7 85 1 1/4 3/4 /150 325 230 50 6 6500 0 130 12,4 95 1 1/4 3/4 /150 410 230 50 6 6500 0 Heating Performance N ominal heat input (nett) N ominal heat output at 80/60 C N ominal heat output at 50/30 C kw kw kw 9.0-8.8-9.2-70.0 68.0 71.4 11.5-90.0 11.2-87.5 11.7-91.8 Maximum gas consumption G20 m3/hr 1.0-7.4 1.2-9.4 1.5-11.5 2.1-13.6 Maximum gas consumption G25 m3/hr 1.1-8.6 1.4-11.5 1.7-13.5 2.5-16.0 Maximum gas consumption G31 m3/hr 0.4-2.9 0.5-3.7 0.6-4.5 0.8-5.3 14.1 -.9 19.6-130.0 Technical data Flue gas dew point Flue temperature at 80/60 C (at ambient temperature of 20 C) C C 52 75 52 75 52 75 52 75 Flue material temperature class T 120 T 120 T 120 T 120 Permitted maxim Pa 140* 140* 140* 140* Condensation ph value 4 to5,5 4 to5,5 4 to5,5 4 to5,5 Maxim ow temperature C 90 90 90 90 CH water pressure (min/max) Bar 0,5 6 0,5 6 0,5 6 0,5 6 Minimum/maximum gas pressure G20 mbar 17-20 17-20 17-20 17-20 G25 mbar 17-20 17-20 17-20 17-20 G31 mbar 30-50 30-50 30-50 30-5 * Environmental data Flue gas CO 2 content G20 % 9.0 9.0 9.0 9.0 G25 % 9.0 9.0 9.0 9.0 G31 % 10.3 10.3 10.3 10.3 Seasonally adjusted Nox** mg/kwh 39.43 37.66 37.55 39.27 Co levels ppm <40 <40 <40 <40 Maxim ciency (nett non condensing) % 97.2 97.2 97.2 97.2 Maxim ciency (nett condensing) % 108.0 108.0 108.0 108.0 Seasonal efficiency % 95.46 95.46 95.46 95.63 With this resistance value the heat output will remain within the speci cations indicated on the data plate; if the resistance is higher, the heat output will drop. he seaesonal Nox levels will decrease 11 70-130Wall Mounted Condensing s

MIKROFILL SYSTEMS LTD WEST COURT MERSE ROAD NORTH MOONS MOAT REDDITCH WORCESTERSHIRE B98 9HL TEL: +44 (0)8452 60 60 20 FAX: +44 (0)8452 60 60 21 EMAIL: info@mikrofill.com WEB: WWW.MIKROFILL.COM 0087 MFS/EB0808