6720646148-11/2010 US/CA

Similar documents
O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Operating instructions

Operating instructions

Operating instructions

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

CARING FOR YOUR WATER HEATER

SL280UHV SERIES GAS FURNACE WARNING

For installation guide see reverse of book

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Baxi Combi 80e & 105e

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

User Manual. Gas fired condensing wall hung boiler. G.C.N : (12 kw) G.C.N : (18 kw) G.C.N : (24 kw)

Servicing instructions

Tankless Water Heater

Operating instructions. For the operator. Operating instructions. ecotec plus. Gas-fired wall hung high efficiency boiler GB, IE

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

Operator: Save these instructions for future use!

Operating Instructions & User s Information Manual VITODENS 100-W WARNING WARNING IMPORTANT. Read and save these instructions for future reference.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Gas Instantaneous Water Heater

Your safety and the safety of others are very important.

Users Instructions BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER

Operating Instructions & User s Information Manual VITODENS 100-W WARNING. IMPORTANT Read and save these instructions for future reference.

Boiler Preparation, Start-Up and Shutdown

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

PART 11: START-UP PROCEDURES FOR THE INSTALLER

FILLING AND PURGING THE SYSTEM

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

Operating Instructions Split System Air Conditioner

Service Manual Models: 502, 752, 1002, 1302,

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Caution! Observe the safety instructions of this installation and maintenance manual before placing the boiler in operation. Danger!

User's Instructions. Alpha HE CB25/33 and HE SY25

User manual. 086U6297 Rev. 9 EN

Combi Eco Elite Range. User s Guide and Important Warranty Information

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Indirect Fired Water Heaters

Response: The combi boiler. Response: The fit anywhere combi

Factory owners must ensure the boiler is:

Laddomat Charging unit

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler

SunMaxx Solar Filling Station Operating Instructions

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold

Servicing manual. Gas wall hung boiler condensing 600 Series - 11S / 19S / 24S / 24C /2006 GB(EN) For trade use

PBX Series Quick Fit Connector Bimetallic Steam Traps

Preventing Overheated Boiler Incidents

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

Cooling system components, removing and installing

User s Operation Manual - contents

Buderus. Flexible Energy Efficient Solutions. Comfortable. Efficient. Intelligent Heating. GB312 Series Natural Gas Condensing Boiler.

Installation and maintenance instructions. Danfoss Vent

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

Oil and Coolant Circulating Heating System. Model - OCSM

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

High kw Electric Tankless Water Heater Troubleshooting Guide

ELECTRIC CENTRAL HEATING FLOW BOILER

Luna 3 Comfort Troubleshooting Guide June 2008

Draining and filling cooling system

Water Heaters. Residential 30, 40 and 50 Gallon

Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Operating Instructions. VITODENS r 200/222 Series With Vitotronic 200 HO1B Controls WARNING WARNING IMPORTANT

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Installation and maintenance instructions

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

Combi 30 HE. User s Guide and Important Warranty Information

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

Vaillant s plain English guide to. simple, concise and precise

Owner s Manual 58HDX UPFLOW / HORIZONTAL / DOWNFLOW HIGH EFFICIENCY GAS FURNACE. ama ! WARNING SAFETY CONSIDERATIONS

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

USER S MANUAL HSC-24A

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Dealer Sales & Service Guide

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Combi 24 HE. User s Guide and Important Warranty Information

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

PC1131 Electric Air Compressor

Description of functions

TANKLESS WATER HEATER USE AND CARE MANUAL

FT-100 Fire Training Fog Machine User Manual English

Laddomat 21 Charging Unit

Service Manual Models:

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

User Manual THR840DUK Digital Thermostat

Cooling system components, removing and installing

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Morco House Riverview Road Beverley HU17 0LD

Transcription:

6720646148-11/2010 US/CA (en) For the user User s Instructions Condensing gas boiler Logamax plus GB162- L.B. 80 kw/100 kw Please read thoroughly before operating This manual is available in the English and French language. This manual must be retained for future use.

Warning: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other boiler. What to do if you smell gas Do not try to light any boiler. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. CAUTION! The operating manual is part of the documentation that is delivered to the installation's operator. Go through the information in this manual with the owner/operator and make sure that he or she is familiar with all the necessary operating instructions. http://www.buderus.net 2

Contents 1 For your safety............... 5 1.1 Designated use.................. 5 1.2 Safety instructions................ 6 1.3 Quality of the heating system water... 8 2 Lighting Instructions........... 9 3 Operating the BC10 basic controller 10 3.1 General....................... 11 3.2 Switching ON and OFF........... 11 3.3 Setting the DHW temperature value. 12 3.4 Setting the space heating water temperature 15 3.5 "Burner ON" LED................ 17 3.6 Other functions and economic heating 17 4 Starting up the boiler......... 18 4.1 Boiler settings...................18 4.2 Check the system pressure.........19 4.3 Fill the heating system............20 4.4 Frost protection..................23 5 Shutting down the boiler...... 24 6 Operating and error messages. 25 6.1 Normal operation menu............25 6.2 Manual Operation menu...........26 6.3 Settings menu...................28 6.4 Display codes...................31 6.5 Identifying and resetting faults......34 http://www.buderus.net 3

Preface About these instructions These user's Instructions contain important information for the safe and proper operation of Logamax plus GB162-80kW/100kW condensing gas boilers. If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Subject to technical changes! Changes may be made following technical improvements! Updating of documentation Please contact us if you have any suggestions for improvements or corrections. http://www.buderus.net 4

For your safety 1 For your safety Logamax plus GB162 condensing gas boilers are designed and built according to the latest technological advances and safety requirements. The design is specifically focused on ease of use. To ensure the safe, economical and environmentally friendly use of the heating system we urge you to read and observe the User's Instructions. 1.1 Designated use The boiler was designed for heating water for a central heating system and generating domestic hot water. The boiler can be installed either as a single system or as part of a multiple system (cascade system) with a maximum of 8 boilers connected together. Hazard definitions A DANGER Indicates the presence of hazards that will cause severe personal injury, death or substantial property damage. A WARNING Indicates the presence of hazards that can cause severe personal injury, death or substantial property damage. A CAUTION Indicates presence of hazards that will or can cause minor personal injury or property damage. H CAUTION Risk of electric shock. Indicates presence of hazards due to electric shock. http://www.buderus.net 5

For your safety I NOTICE Indicates special instructions on installation, operation or maintenance that are important but not related to personal injury or property damage. 1.2 Safety instructions Make sure to observe these safety instructions. Failure to do so can result in property damage, personal injury or loss of life. Installation, gas and flue connection, commissioning, electrical connection and maintenance activities must only be carried out by a trained service provider. Certain work, e.g. on gas lines, may require a professional license. Only carry out such work if you are licensed to do so. Only use the boiler for its intended purpose and only when it is in working order. Have a trained service provider check, clean and service the heating system once a year. Buderus recommends a contract for annual service and maintenance. The condensate collection and disposal system must be periodically cleaned by a trained service technician. Have your trained service provider give you detailed instructions about the operation of the heating system. Carefully read these user's instructions. Immediately have all defects to the heating system repaired. Ensure that air intake and outlet openings are open and free from obstructions at all times. http://www.buderus.net 6

Do not store any flammable material or liquids in the immediate vicinity of the boiler. Never use chlorinated detergents or halogenated hydrocarbons (e.g. in spraycans, solvents and detergents, paints, adhesives) in the room where the boiler is installed. When Calcium Chloride is present in concrete floors (when poured in winter) it is necessary to seal the floor with a suitable paint. Do not allow too much dust to collect on the device. Do not use the boiler if any part has been under water. Immediately call a trained service technician to inspect the boiler and to replace any part of the control system and any gas control which has been under water. For your safety Should overheating occur or the gas supply fails to shut off, do not turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the boiler. The venting system must be inspected annually. Replace any parts which show deterioration from corrosion or any other sources. This boiler does not have a pilot. It has an ignition device which automatically lights the burner. Check for smell of gas around the boiler area. Be sure to smell next to the floor because propane gas is heavier than air and will settle on the floor. Use only your hand to turn the gas control knob (fig. 4 on page 18). Never use tools. If the knob will not turn by hand, don't try to http://www.buderus.net 7

For your safety repair it, call a trained service technician. Force or attempted repair may result in a fire or an explosion. When the vent system is blocked, this boiler will shut off automatically with code '3C'. Immediately call a trained service technician to inspect and reset the boiler. 1.3 Quality of the heating system water Use only untreated tap water when filling or topping up the heating system. The use of unsuitable heating system water will lead to build-ups of sludge and corrosion, which can in turn result in the malfunctioning of the boiler and damage to the heat exchanger. DO NOT treat the water with products such as ph-adjusting substances (chemical additives) and antifreeze or water softeners. http://www.buderus.net 8

Lighting Instructions 2 Lighting Instructions A STOP! Read the chapter "For your safety" on page 5 before lighting the boiler. Follow the instructions to start up the boiler in Starting up the boiler on page 18. http://www.buderus.net 9

3 Operating the BC10 basic controller Operating the BC10 basic controller 10 9 8 100 90 110 120 130 140 888 110 90 130 150 170 190 11 1 2 3 4 5 6 7 1 Fig. 1 Logamatic BC10 basic controller Controls 1: Main power switch 5: Service Tool connector 2: "Reset" button 6: LED "Burner operation" 3: "Chimney sweep" button 7: LED "Heating system status" 4: "Service" button 8: Space heating water temperature knob 9: Display 10: DHW temperature knob 11: LED "DHW status" http://www.buderus.net 10

3.1 General The boiler is equipped with a control unit, the BC10 basic controller (fig. 2). This controller can be used to control the heating system. Operating the BC10 basic controller I NOTICE If your heating system consists of several boilers (cascade system), you have to carry out the settings on the control units of all individual boilers. Push on the control panel to open it (fig. 2) and get access to the controller. Fig. 2 Opening the control panel 3.2 Switching ON and OFF Set the main switch on the BC10 to position "1" (ON) to switch ON the boiler and set it to "0" to switch the boiler OFF. http://www.buderus.net 11

Operating the BC10 basic controller H CAUTION Risk of electric shock. If a hazardous situation occurs, shut OFF power to the boiler using the emergency shutoff switch or the boiler circuit breaker (see chapter 4 "Starting up the boiler", page 18). Make yourself familiar with the location of the emergency shutoff switch and the boiler loop circuit breaker. 3.3 Setting the DHW temperature value Check the local code for the max. DHW temperature. Turn the "DHW temperature" rotary knob to set the desired temperature of the hot water in the DHW tank. 100 90 110 120 130 140 http://www.buderus.net 12

Operating the BC10 basic controller Condition Explanation LED 0 OFF No hot water supply (only heating mode). OFF Eco 1 Economy mode, Hot water temperature 140 F (60 C) The DHW will only be reheated to 140 F (60 C), if the temperature has signifcantly fallen. This reduces the number of burner starts and saves energy. As a result the water may be a bit cooler initially. ON 2 86 140 Direct setting on BC10 in F Aut Entry via thermostat (presetting) The temperature set on the BC10 is a fixed temperature that cannot be changed using a RC thermostat. The temperature setting defaults to the maximum DHW temperature of 140 F (60 C). ON 2 ON 2 Tabel 1 Settings of "DHW temperature" knob 1 This function has been optimized for boilers with combined DHW heating (combi-units). 2 The LED under the rotary knob lights if the DHW temperature is below the target value (heat request for DHW). http://www.buderus.net 13

Operating the BC10 basic controller Anti-scald table Temperature of water Minimum time for first degree burn Minimum time for second or third degree burn 111 F (44 C) 5 hours 7 hours 116 F (47 C) 35 minutes 45 minutes 118 F (48 C) 10 minutes 14 minutes 122 F (50 C) 1 minute 5 minutes 131 F (55 C) 5 seconds 25 seconds 140 F (60 C) 2 seconds 5 seconds 149 F (65 C) 1 second 2 seconds 158 F (70 C) 1 second Tabel 2 Temperature/Time/Burn Chart http://www.buderus.net 14

Operating the BC10 basic controller 3.4 Setting the space heating water temperature Turn the "space heating water temperature" knob to set the upper limit value of the heater water for the heating operation. This limitation does not apply to DHW preparation. 110 90 130 150 170 190 http://www.buderus.net 15

Operating the BC10 basic controller Condition Explanation LED 0 OFF No supply to heating system (only DHW heating OFF operation). 86 190 Direct setting on BC10 in F The temperature set on the BC10 acts as a high limit. ON 1 With a AM10 or RC10 control, the water temperature will be at a equal or lesser value. With a On/Off thermostat the water temperature will always be the set temperature. Supply temperature never rises above the set temperature. Aut Entry via thermostat (presetting) The temperature high limit setting defaults to the ON 1 maximum boiler water temperature of 190 F (90 C). Tabel 3 Settings of "space heating water temperature" rotary knob 1 The LED under the rotary knob lights when the heating system is switched ON and heat is requested. In summer mode the heating system is switched OFF (LED OFF). http://www.buderus.net 16

Operating the BC10 basic controller 3.5 "Burner ON" LED The LED indicates the operating condition of the burner. LED Condition Explanation ON Burner active The water in the boiler is being heated. OFF Burner OFF The water in the boiler has reached the required temperature or there is no heat request. Tabel 4 LED indication 3.6 Other functions and economic heating The functions described above are basic functions, carried out directly on the boiler using the BC10 basic controller. http://www.buderus.net 17

Starting up the boiler 4 Starting up the boiler 4.1 Boiler settings Turn the "space heating water temperature" and "DHW temperature" rotary knobs to "Aut" (automatic mode). The control unit will now take control. 100 90 110 120 130 140 + 90 110 130 150 170 190 Slowly open the gas valve by pushing on the gas valve and turning it ¼ rotation in an counterclockwise direction (fig. 3, pos. 1). The gas valve is open when it is in its vertical position. Open the pump group isolating valves (fig. 3, pos. 2). 1 2 Fig. 3 Opening gas- and isolating valves http://www.buderus.net 18

Starting up the boiler Set the main switch on the basic controller to position "1" (ON). The basic controller checks the current system status and the burner becomes operational as soon as there is a heat request. This procedure takes approx. 30 seconds. Adjust the settings on the control unit (see the Operating Instructions for the control unit). 4.2 Check the system pressure If the heating system has just been filled, the system pressure must initially be checked every day, for 1 week. The maximum pressure in the heating system, measured directly at the boiler, must not exceed 51 psi (3.5 bar). Press the "Service" button (fig. 1, pos. 4) until the system pressure ("P22") is shown in the display (pos. 9). http://www.buderus.net 19

Starting up the boiler Fill the heating system if the system pressure has dropped below 15 psi (1.0 bar) according to paragraph Fill the heating system on page 20. 4.3 Fill the heating system Remove the lower casing from the pump group (fig. 4). Fig. 4 Removing the lower casing http://www.buderus.net 20

Starting up the boiler Unscrew the sealing cap (fig. 5). Fig. 5 Removing cap from drain cock http://www.buderus.net 21

Starting up the boiler Fill the heating system to a pressure of appx. 20 psi (1.5 bar). Read the pressure from the 20 30 pressure gauge on the pump group or on the 10 psi control panel of the BC10 (fig. 6). 110 The pressure in the heating system, which is 110 100 120 90 90 130 measured directly at the boiler, must be at least 140 P22 equal to the required pre-pressure of the expansion vessel plus 7 psi (0.5 bar). The minimum pressure 1 must not be less than 15 psi (1.0 bar) (if the heating system is cold). The maximum pressure in the heating system must not exceed 50 psi (3.5 bar). Fig. 6 Reading the pressure gauge I NOTICE It is very important that the heating system is now purged, since all air will collect at the highest point of the heating system when the system is slowly filled with water. 130 150 170 190 http://www.buderus.net 22

Purge the heating system via the air vents/valves on the heating bodies. Start at the first floor of the premises and then work your way up (fig. 7). The pressure loss in a heating system is caused by air bubbles escaping via fittings and (automatic) air vents. The oxygen contained in the fresh heating water will also escape from the heating water after some time and cause a pressure loss. Topping up once a year is normal. If it is necessary to top up more frequently, there might be a leak in the system or a defective expansion vessel. This must be remedied as soon as possible. 4.4 Frost protection When switched on, the boiler has an integrated frost protection system. This means that no further frost protection facilities should be installed on the boiler. The frost protection switches the boiler on at a flow temperature of 45 F (7 C) and off at a flow temperature of 59 F (15 C). The heating system itself is not protected against frost. Fig. 7 Starting up the boiler Purging a radiator (example) http://www.buderus.net 23

Shutting down the boiler 5 Shutting down the boiler Set the main switch on the basic controller to position "0" (OFF). Close the gas shut-off valve and disconnect the boiler from the power supply. A DANGER The heating system may freeze if it is not operational in times of freezing weather. Protect the heating system against freezing if there is a danger of frost affecting the system. Drain the heating system water from the lowest point of the heating system using the boiler filling and draining cock. The vent screw at the highest point of the heating system must then be open. http://www.buderus.net 24

Operating and error messages 6 Operating and error messages In normal operating mode, the display shows the current heater water temperature. You can display other information using the "Service" button. Also see section 6.4. Push the "Service" button (pos. 4) a number of times to switch between the various status displays. 110 100 120 90 130 140 10 9 8 1 888 90 110 130 150 170 190 11 1 2 3 4 5 6 7 6.1 Normal operation menu Fig. 8 Basic controller BC10 Normal Operation menu [\/2/4 Shows currently measured space heating water temperature in F. e [p/2/2 Shows currently measured system pressure in psi. e [-/h/\ Current display code. In this case: Operating phase: Boiler in heating mode. Tabel 5 Normal operation http://www.buderus.net 25

Operating and error messages 6.2 Manual Operation menu In manual mode, the heating system can be operated independent of a room controller (e. g. RC35). I NOTICE Re-start manual operation after switching on the heating system, so that the system is permanently in operation (especially if there is a risk of freezing). Manual Operation menu To activate manual operation: Press and hold the d button for more than 5 seconds. d [\/2/4} A flashing dot in the right-hand bottom corner of the display shows manual operation is active. This means that the boiler is permanently in heating mode: Space heating water temperature is as set on the BC10 basic controller. The LED "Heating system status" lights. DHW mode is possible during manual operation. e [p/1.6} Shows currently measured system pressure in psi(pounds per square inch). Tabel 6 Manual operation http://www.buderus.net 26

Operating and error messages Manual Operation menu e [-/h/\} Display code: Operating phase: Also see section 6.4. The boiler is in manual operation mode. During manual operation the "Settings" menu (table 7 from step 2) can be used to temporarily change the target boiler performance. Notice: If the boiler output has been changed temporarily, this must be set again after ending manual operation, according to the "Settings" menu (table 7). e [\/2/4}Shows currently measured space heating water temperature in F. After a power interruption manual operation ends automatically. To end manually press and hold the d button for more than 2 seconds until the dot disappears. Tabel 6 Manual operation (continued) http://www.buderus.net 27

Operating and error messages 6.3 Settings menu Three settings can be made in the Settings menu: Modulation rate Post purge time DHW mode (On/off). I NOTICE The modulation rate and the DHW mode should be set by a trained installer. If you will be on vacation for a long period while there is a risk of freezing, the post purge time will have to be set (section 4.1 on page 18). Settings menu d e Tabel 7 To open the "Settings" menu: Press and hold the d+ e buttons for more than 2 seconds. [l//// This shows the "Settings" menu is open. You can adjust the setting of this parameter. Settings http://www.buderus.net 28

Settings menu e Tabel 7 Operating and error messages [l//// modulation rate. Adjust as follows, or press e: Lower:Decrease the modulation rate with the c button. The minimum setting is [l/3/6 = 36 % with an 80-kW boiler and [l/3/0 = 30 % with a 100-kW boiler. Higher: Increase the modulation rate with the d button. The maximum setting is [l//// = 100 %. This is equal to the factory setting. [f/\/5 Pump run-over time in minutes (starts when the heating mode has ended). Adjust as follows or or go to the next step: Lower: Decrease the time with the c button. The minimum setting is [f/\/0 = 0 minutes. The factory default setting is 5 minutes. CAUTION Do not set the post purge time to less than 5 minutes. Higher: Increase the time with the d button. The maximum setting is [f/6/0 = 60 minutes or [f/1/d = 24 hours. Settings (continued) http://www.buderus.net 29

Operating and error messages Settings menu e [c/\/1 DHW mode status setting. Adjust as follows, or press e: DHW mode can be switched OFF or ON. This setting has priority over other DHW mode settings, such as those made on the room thermostat. Set the DHW mode with the c or d buttons. [c/\/1 means "ON", [c/\/0 means "OFF". NOTE: Setting [c/\/0 also switches OFF the hot water cylinder frost protection. After 5 seconds or after a power interruption the settings menu ends automatically. To end manually press the e button.. Any adjustments that you have made have been confirmed. Tabel 7 Settings (continued) http://www.buderus.net 30

Operating and error messages 6.4 Display codes The display shows the condition of the boiler with a code. The table below shows normal operation codes. If a different code shows, please refer to section 6.5, "Identifying and resetting faults" on page 34. Display codes [\/-/\ [-/a/\] dot [-/h/\ Communication test while starting up. Any display code with a dot in the bottom right-hand corner. The boiler is in flue gas test or service mode. The boiler is in heating mode. [-/h/} Any display code with a flashing dot in the bottom right-hand corner. flashing The boiler is in manual operation mode. dot Tabel 8 Display codes http://www.buderus.net 31

Operating and error messages Display codes [=/h/\ [0/a/\ [0/c/\ [0/e/\ [0/h/\ [0/l/\ Tabel 8 The boiler is in DHW (domestic hot water) mode, or The boiler is in pump run-over time via the external hot water cylinder 130 seconds at the minimum speed. The "Burner" LED (On/Off) is off. Boiler interval circuit. The boiler cannot start-up more than once every 10 minutes. This program is activated if there has been a DHW request from an RC regulator more frequently than once every 10 minutes. The boiler prepares for a burner start-up. There is a current heat demand or a DHW request. The boiler is standby. There is a current heat demand, but too much energy has been supplied. The boiler is standby. There is no current heat demand. Ignition phase. The gas valve is activated. Display codes (continued) http://www.buderus.net 32

[0/u/\ [0/y/\ [2/e/\ Operating and error messages Start-up phase. The boiler starts up after activation of the main power supply or completion of a system reset. The flow temperature is higher than set. Fault (subcode [2/0/7 ). The system pressure is too low (less than 3 psi (0.2 bar)). [8/8/8 Display test during start-up phase (max. 1 second). [h/\/7 Display codes The system pressure is too low (less than 12 psi (0.8 bar)). [h/\/7 [p///// The system pressure is too low (less than 12 psi (0.8 bar)). The system pressure is too high (higher than 58 psi (4.0 bar)). [\/r/e The boiler is resetting. Tabel 8 Display codes (continued) http://www.buderus.net 33

Operating and error messages 6.5 Identifying and resetting faults If a fault occurs, the error code flashes ON and OFF on the display of the BC10 basic controller. Push the "Reset" button for approx. 5 seconds to reset the fault. The display shows "re" while resetting. Reset is only possible if there is a flashing error message. If the display then shows a normal operation message from tabel 8, this means that the fault has been remedied. If the fault recurs, you must repeat resetting two or three more times. If the fault cannot be reset: Write down the error message and contact your heating equipment service company. Make sure that the heating system is not damaged by frost (see the safety instructions in chapter Shutting down the boiler on page 24). http://www.buderus.net 34

Notes http://www.buderus.net 35

Bosch Thermotechnology Corporation 50 Wentworth Ave Londonderry, NH 03053 Tel: (603)-552-1100 Fax: (603)-421-2719 Toll Free: 1-800-BUDERUS www.buderus.net 6720646148 0002