DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Similar documents
Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Pressure transmitter For general industrial applications Model A-10

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Inductive sensor NI10-M18-Y1X-H1141

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Relative pressure transmitter type 520

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

How To Use A Flowmeter

Technical Data. Dimensions

Digital inductive conductivity transmitter

Technical Data. Dimensions

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Conductive Level Switch FK 2 Technical Data:

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Solenoid Valve Island Type 3965

Compact pressure switch Flameproof enclosure Ex d Model PCA

Electronic Pressure Monitoring New Products

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Relative and absolute pressure switch type 529

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

4 Posiflow Proportional Solenoid Valves

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 3000

Assisted lift operated 2/2-way solenoid valves Type EV250B

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Plastic tube flowmeters Series PT/PS

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Instruction Manual Differential Pressure Transmitter

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Features. Picture. Specifications

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Data Sheet PS1B Pressure Switch

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

Pressure transmitter PASCAL CV

Threaded Resistance Thermometers Model TR10-D, Miniature Design

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Series 8146/5-V37 and Series 8150/5-V37

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Flow switches Series AD/VH

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Operating Instructions for Plastic Flow Meter. Model: KSK

Duct Humidity Transmitter

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Contents. Document information

CAPACITIVE LEVEL METERS CLM 36

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

Differential Pressure Transmitter Model DPT-10

Product Catalogue. AP Automatyka ISO ISO OHSAS ISO 9001.

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Differential-Hall-Effect based Sensors Series A5S Overview

Vacuum drying oven for non-flammable solvents

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Models SFP33 & SFP32 Pressure Transmitters

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

Solenoid valves 2/2-way direct-operated Type EV210A

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Redundancy Module QUINT-DIODE/40

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Connection technology from ifm.

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Inductive slot sensor

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

Digital display DA 48

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Cable Plug acc. to DIN EN , Form A

ATL Fuel Level Sender Probes

psens Pressure Measurement

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

OPTIMASS 1400 Technical Datasheet

Confidential. Proportional reducer D386 ATEX. Male base connector View from weld side

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Differential-Hall-Effect based Sensors Series A5S

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Precision digital pressure gauge Model CPG1500

Transcription:

DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals -wire: 4... 0 ma -wire: 0 0 ma / 0 0 V others on request Special characteristic perfect thermal behaviour excellent long term stability pressure port G /" flush from 00 mbar Optional versions IS-version Ex ia = intrinsically safe for gases and dusts SIL -according to IEC 6508 / IEC 65 pressure sensor welded The pressure transmitter DMP can be used in all industrial areas when the medium is compatible with stainless steel.4404 (6 L) or.445 (6 L). Additional are different elastomer seals as well as a helium tested welded version available. The modulare concept of the device allows to combine different stainless steel sensors and electronic modules with a variety of electrical and mechanical versions.thus a diversity of variations is created, meeting almost all requirements in industrial applications. Preferred areas of use are Plant and Machine Engineering Environmental Engineering (water - sewage - recycling) Energy Industry specific versions BD SENSORS GmbH BD-Sensors-Straße Tel: +49 (0) 9 5 / 98-0 www.bdsensors.com D - 9599 Thierstein Fax: +49 (0) 9 5 / 98 - info@bdsensors.de

DMP Input pressure range gauge / abs. [bar] - 0 0.0 0.6 0.5 0.40 0.60.6 Overpressure [bar] 5 0.5 5 5 0 Burst pressure [bar] 7.5.5.5.5 7.5 7.5 5 gauge / abs. [bar].5 4 6 0 6 5 40 Overpressure [bar] 0 0 40 40 80 80 05 Burst pressure [bar] 5 5 50 50 0 0 0 Vacuum resistance P N bar: unlimited vacuum resistance P N < bar: on request Output signal / Supply Standard -wire: 4... 0 ma / V S = 8... V DC Option IS-protection -wire: 4... 0 ma / V S = 0... 8 V DC Options -wire -wire: 0... 0 ma / V S = 4... 0 V DC 0... 0 V / V S = 4... 0 V DC Performance Accuracy standard: nominal pressure < 0.4 bar: ± 0.5 % FSO nominal pressure 0.4 bar: ± 0.5 % FSO option : nominal pressure 0.4 bar: ± 0.5 % FSO option : for all nominal pressure: ± 0. % FSO Permissible load current -wire: R max = [(V S V S min) / 0.0 A] Ω current -wire: R max = 500 Ω voltage -wire: R min = 0 kω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year at reference conditions Response time -wire: 0 msec -wire: msec accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) P N [bar] - 0 < 0.40 0.40 Tolerance band [% FSO] ± 0.75 ± ± 0.75 in compensated range [ C] -0... 85 0... 70-0 85 Permissible temperatures Permissible temperatures medium: -40... 5 C electronics / environment: -40... 85 C storage: -40... 00 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS (5... 000 Hz) according to DIN EN 60068--6 Shock 500 g / msec according to DIN EN 60068--7 Materials Pressure port stainless steel.4404 (6 L) Housing stainless steel.4404 (6 L) Option compact field housing stainless steel.405 (0), cable gland brass, nickel plated others on request Seals (media wetted) standard: FKM options: EPDM NBR welded version others on request Diaphragm stainless steel.445 (6 L) Media wetted parts pressure port, seals, diaphragm welded version only with pressure ports according to EN 87 Explosion protection (only for 4 0 ma / -wire) Approvals IBExU 0 ATEX 068 X / IECEx IBE.007X DX9-DMP zone 0: II G Ex ia IIC T4 Ga zone 0: II D Ex ia IIIC T 85 C Da Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 µh, the supply connections have an inner capacity of max. 7 nf to the housing Permissible temperatures for in zone 0: -0... 60 C with p atm 0.8 bar up to. bar environment in zone or higher: -0... 70 C Connecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 60 pf/m cable inductance: signal line/shield also signal line/signal line: µh/m pressure and level

DMP Miscellaneous Option SIL according to IEC 6508 / IEC 65 Current consumption signal output current: max. 5 ma signal output voltage: max. 7 ma Weight approx. 40 g Installation position any 4 Operational life > 00 x 0 6 pressure cycles CE-conformity EMC Directive: 004/08/EC ATEX Directive 94/4/EG only for 4 0 ma / -wire, not in combination with the accuracy 0.% 4 Pressure transmitters are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight deviations in the zero point for pressure ranges P N bar. Wiring diagrams -wire-system (current) p supply + -wire-system (current / voltage) p supply + V S I supply VS supply I / U signal + A / V Pin configuration Electrical connection ISO 4400 Supply + Supply Signal + (for -wire) Electrical connections (dimensions in mm) Binder 7 (5-pin) 4 Mx / metal (4-pin) Shield ground pin 5 4 field housing IN + IN - OUT+ cable colours (DIN 4700) wh (white) bn (brown) gn (green) ye/gn (yellow / green) standard option ISO 4400 Binder Series 7 5-pin Mx 4-pin cable outlet with PVC cable (IP 65) (IP 67) (IP 67) (IP 67) 5 compact field housing cable outlet, cable with ventilation tube (IP 67) (IP 68) 6 universal field housing stainless steel.4404 (6 L) with cable gland M0x.5 (ordering code 880) and other versions on request 5 standard: m PVC cable without ventilation tube (permissible temperature: -5... 70 C) 6 different cable types and lengths available, permissible temperature depends on kind of cable www.bdsensors.com

DMP Mechanical connections (dimensions in mm) standard for accuracy 0.5 / 0.5 % standard for accuracy 0. %; SIL- and SIL-IS-version G/" DIN 85 G/" DIN 85 with ISO 4400 with ISO 4400 option G/" EN 87 G/" open port G/" DIN 85 with flush sensor G/4" DIN 85 G/4" EN 87 /" NPT /4" NPT metric threads and other versions on request This data sheet contains product specification, properties are not guaranteed. Subject to change without notice. pressure Tel and +49 level (0) 9 5 / 98-0 www.bdsensors.com Fax +49 (0) 9 5 / 98 - info@bdsensors.de DMP_E_080

Ordering code DMP DMP - - - - - - - Pressure gauge absolute 0 Input [bar] 0.0 0 0 0 0.6 6 0 0 0.5 5 0 0 0.40 4 0 0 0 0.60 6 0 0 0.0 0 0.6 6 0.5 5 0 4.0 4 0 0 6.0 6 0 0 0 0 0 6 6 0 5 5 0 40 4 0 0-0 X 0 9 9 9 Output 4 0 ma / -wire 0 0 ma / -wire 0 0 V / -wire Intrinsic safety 4 0 ma / -wire SIL 4 0 ma / -wire SIL with intrinsic safety 4 0 ma / -wire E S ES Accuracy standard for P N 0.4 bar 0.5 % standard for P N < 0.4 bar 0.5 % 5 option for P N 0.4 bar 0.5 % option 0. % Electrical connection Male and female plug ISO 4400 Male plug Binder series 7 (5-pin) Cable outlet with PVC cable Cable outlet Male plug Mx (4-pin) / metal 0 0 0 0 T A 0 T R 0 M 0 Compact field housing stainless steel.405 8 5 0 9 9 Mechanical connection G/" DIN 85 G/" EN 87 G/4" DIN 85 G/4" EN 87 0 0 0 0 0 0 4 0 0 G/" DIN 85 with flush sensor F 0 0 G/" DIN 85 open pressure port /" NPT /4" NPT H 0 0 N 0 0 N 4 0 9 9 Seals FKM EPDM NBR without (welded version) 4 5 Special version standard 0 0 0 9 9 not in combination with SIL standard: m PVC cable without ventilation tube (permissible temperature: -5 70 C), others on request cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, price without cable 4 welded version only with pressure ports according to EN 87 07.0.0 This dokument contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.