Cylindrical Proximity Sensor E2A. Ordering Information. DC 3-wire models (NO + NC: DC 4-wire) *2

Similar documents
Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

E2A Single Sensing Distance

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Thread length (overall length) 27 (40) 49 (62) 27 (43) 49 (65) 27 (43) 49 (65) 27 (39) 49 (61) 27 (40) 49 (62) 27 (43) 49 (65) 27 (43) 49 (65)

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Cylindrical Proximity Sensor

How To Read A Pipe From A Sensor

Capacitive Prox E2K-X

Small-diameter Proximity Sensor

Proximity Sensor with All-stainless Housing

Cylindrical Proximity Sensor

Absolute Rotary Encoder E6CP

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Inductive sensor NI10-M18-Y1X-H1141

Ordering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67

Cross-beam scanning system to detect slim objects. 100 mm in

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Model Number Structure

Model Number Structure

Liquid Leakage Sensor Amplifier

Solid-State Timer H3G

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Type Supply voltage Output Connection Sensing range Standard target Timer function Part number Polarized VDC NPN/PNP Pre-leaded 500 mm to 10 m

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Thread length (overall length)

Adjustment functions for both span and shift have been incorporated

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Incremental Rotary Encoder E6B2

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Color Mark Sensor with Red or Green LED E3S-VS

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Inductive Proximity Sensors

SPST-NO SPDT DPST-NO DPDT

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Ordering Information. Application Example. New General-purpose Incremental. Rotary Encoder. Accessories (Order Separately)

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

pre-wired E3FC-TN11 2M *1 E3FC-TP11 2M *1

RY2 miniature industrial relays

Smart DeviceNet Remote I/O Terminals

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

E2K-X. General-purpose Threaded Sensor That Detects Metals and Non-metals Alike. Cylindrical Proximity Sensor. Ordering Information.

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

Cable Plug acc. to DIN EN , Form A

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

How To Use A Flowmeter

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

General-purpose Relay

SPST-NO SPDT DPST-NO DPDT

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

NX safety stand-alone

Givare NC-SRS 280 och 880

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Inductive sensors. Compact, fast, reliable. Edition 2013

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Count input Display Time range h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) 3. Case Color B: Black

U-shaped Micro Photoelectric Sensor

How To Power A Schen

CQM1-SF200/CS1W-SF200

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

Features. 3.5 mm flat model with background supression (BGS) with highest repeatability even for differently coloured objects.

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Multifunction Digital Timer

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

User s Manual Before using the inverter, you need to read and save the safety instructions.

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

PM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Magnetic proximity switches

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Solid State Relays for Heaters

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Fast, reliable, ultra-precise. My-Com precision switches.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Transcription:

Cylindrical High quality for extra long life in daily use wide portfolio range through modular concept designed and tested for extra long life IP67 and IP69k for highest protection in wet environments continuously high quality level through specialized manufacturing process DC -wire and DC 2-wire models Normally open (NO), normally closed (NC) and antivalent (NO+NC) models up to mm sensing Stainless steel and brass housings Pre-wired versions with different cable materials and diameters, and M2 types, pre-wired types with cable end s Ordering Information DC -wire models (NO + NC: DC -wire) *2 Size Connection Body material Thread length (overall length) Output configuration Operation mode NO Operation mode NC Pre-wired 27 () 9 (62) PNP -S8KS2-WP-B 2M -S8KS2-WP-B2 2M NPN -S8KS2-WP-C 2M -S8KS2-WP-C2 2M PNP -S8LS2-WP-B 2M -S8LS2-WP-B2 2M NPN -S8LS2-WP-C 2M -S8LS2-WP-C2 2M Shielded 2. mm M2 (-pin) 27 () 9 (65) 27 (9) 9 (6) PNP -S8KS2-M-B -S8KS2-M-B2 NPN -S8KS2-M-C -S8KS2-M-C2 PNP -S8LS2-M-B -S8LS2-M-B2 NPN -S8LS2-M-C -S8LS2-M-C2 PNP -S8KS2-M5-B -S8KS2-M5-B2 NPN -S8KS2-M5-C -S8KS2-M5-C2 PNP -S8LS2-M5-B -S8LS2-M5-B2 NPN -S8LS2-M5-C -S8LS2-M5-C2 (-pin) Pre-wired Stainless steel* 27 (9) 9 (6) 27 () 9 (62) PNP -S8KS2-M-B -S8KS2-M-B2 NPN -S8KS2-M-C -S8KS2-M-C2 PNP -S8LS2-M-B -S8LS2-M-B2 NPN -S8LS2-M-C -S8LS2-M-C2 PNP -S8KN-WP-B 2M -S8KN-WP-B2 2M NPN -S8KN-WP-C 2M -S8KN-WP-C2 2M PNP -S8LN-WP-B 2M -S8LN-WP-B2 2M NPN -S8LN-WP-C 2M -S8LN-WP-C2 2M Nonshielded. mm M2 (-pin) 27 () 9 (65) 27 (9) 9 (6) PNP -S8KN-M-B -S8KN-M-B2 NPN -S8KN-M-C -S8KN-M-C2 PNP -S8LN-M-B -S8LN-M-B2 NPN -S8LN-M-C -S8LN-M-C2 PNP -S8KN-M5-B -S8KN-M5-B2 NPN -S8KN-M5-C -S8KN-M5-C2 PNP -S8LN-M5-B -S8LN-M5-B2 NPN -S8LN-M5-C -S8LN-M5-C2 ( pin) 27 (9) 9 (6) PNP -S8KN-M-B -S8KN-M-B2 NPN -S8KN-M-C -S8KN-M-C2 PNP -S8LN-M-B -S8LN-M-B2 NPN -S8LN-M-C -S8LN-M-C2 *.

M2 M8 Size Output configuration Shielded Nonshielded Shielded Nonshielded. mm 8. mm 8. mm 6. mm Connection Body material Thread length (overall length) Pre-wired Brass * (5) M2 Brass * (-pin) (-pin) 56 (72) (8) 56 (7) Brass * (8) 56 (7) Brass * (8) 56 (7) Pre-wired Brass * (5) M2 Brass * (-pin) (-pin) 56 (72) (8) 56 (7) Brass * (8) 56 (7) Brass * (8) 56 (7) Pre-wired Brass * 9 (59) M2 Brass * (-pin) (-pin) 6 (8) 9 (5) 6 (75) Brass * 9 (5) 6 (75) Brass * 9 (5) 6 (75) Pre-wired Brass * 9 (59) M2 Brass * (-pin) (-pin) 6 (8) 9 (5) 6 (75) Brass * 9 (5) 6 (75) Brass * 9 (5) 6 (75) Operation mode NO Operation mode NC Operation mode NO + NC PNP -M2KS-WP-B 2M -M2KS-WP-B2 2M -M2KS-WP-B 2M NPN -M2KS-WP-C 2M -M2KS-WP-C2 2M -M2KS-WP-C 2M PNP -M2LS-WP-B 2M -M2LS-WP-B2 2M -M2LS-WP-B 2M NPN -M2LS-WP-C 2M -M2LS-WP-C2 2M -M2LS-WP-C 2M PNP -M2KS-M-B -M2KS-M-B2 -M2KS-M-B NPN -M2KS-M-C -M2KS-M-C2 -M2KS-M-C PNP -M2LS-M-B -M2LS-M-B2 -M2LS-M-B NPN -M2LS-M-C -M2LS-M-C2 -M2LS-M-C PNP -M2KS-M5-B -M2KS-M5-B2 n.a. NPN -M2KS-M5-C -M2KS-M5-C2 n.a. PNP -M2LS-M5-B -M2LS-M5-B2 n.a. NPN -M2LS-M5-C -M2LS-M5-C2 n.a. PNP -M2KS-M-B -M2KS-M-B2 n.a. NPN -M2KS-M-C -M2KS-M-C2 n.a. PNP -M2LS-M-B -M2LS-M-B2 n.a. NPN -M2LS-M-C -M2LS-M-C2 n.a. PNP -M2KN8-WP-B 2M -M2KN8-WP-B2 2M -M2KN8-WP-B 2M NPN -M2KN8-WP-C 2M -M2KN8-WP-C2 2M -M2KN8-WP-C 2M PNP -M2LN8-WP-B 2M -M2LN8-WP-B2 2M -M2LN8-WP-B 2M NPN -M2LN8-WP-C 2M -M2LN8-WP-C2 2M -M2LN8-WP-C 2M PNP -M2KN8-M-B -M2KN8-M-B2 -M2KN8-M-B NPN -M2KN8-M-C -M2KN8-M-C2 -M2KS8-M-C PNP -M2LN8-M-B -M2LN8-M-B2 -M2LS8-M-B NPN -M2LN8-M-C -M2LN8-M-C2 -M2LS8-M-C PNP -M2KN8-M5-B -M2KN8-M5-B2 n.a. NPN -M2KN8-M5-C -M2KN8-M5-C2 n.a. PNP -M2LN8-M5-B -M2LN8-M5-B2 n.a. NPN -M2LN8-M5-C -M2LN8-M5-C2 n.a. PNP -M2KN8-M-B -M2KN8-M-B2 n.a. NPN -M2KN8-M-C -M2KN8-M-C2 n.a. PNP -M2LN8-M-B -M2LN8-M-B2 n.a. NPN -M2LN8-M-C -M2LN8-M-C2 n.a. PNP -M8KS8-WP-B 2M -M8KS8-WP-B2 2M -M8KS8-WP-B 2M NPN -M8KS8-WP-C 2M -M8KS8-WP-C2 2M -M8KS8-WP-C 2M PNP -M8LS8-WP-B 2M -M8LS8-WP-B2 2M -M8LS8-WP-B 2M NPN -M8LS8-WP-C 2M -M8LS8-WP-C2 2M -M8LS8-WP-C 2M PNP -M8KS8-M-B -M8KS8-M-B2 -M8KS8-M-B NPN -M8KS8-M-C -M8KS8-M-C2 -M8KS8-M-C PNP -M8LS8-M-B -M8LS8-M-B2 -M8LS8-M-B NPN -M8LS8-M-C -M8LS8-M-C2 -M8LS8-M-C PNP -M8KS8-M5-B -M8KS8-M5-B2 n.a. NPN -M8KS8-M5-C -M8KS8-M5-C2 n.a. PNP -M8LS8-M5-B -M8LS8-M5-B2 n.a. NPN -M8LS8-M5-C -M8LS8-M5-C2 n.a. PNP -M8KS8-M-B -M8KS8-M-B2 n.a. NPN -M8KS8-M-C -M8KS8-M-C2 n.a. PNP -M8LS8-M-B -M8LS8-M-B2 n.a. NPN -M8LS8-M-C -M8LS8-M-C2 n.a. PNP -M8KN6-WP-B 2M -M8KN6-WP-B2 2M -M8KN6-WP-B 2M NPN -M8KN6-WP-C 2M -M8KN6-WP-C2 2M -M8KN6-WP-C 2M PNP -M8LN6-WP-B 2M -M8LN6-WP-B2 2M -M8LN6-WP-B 2M NPN -M8LN6-WP-C 2M -M8LN6-WP-C2 2M -M8LN6-WP-C 2M PNP -M8KN6-M-B -M8KN6-M-B2 -M8KN6-M-B NPN -M8KN6-M-C -M8KN6-M-C2 -M8KS6-M-C PNP -M8LN6-M-B -M8LN6-M-B2 -M8LS6-M-B NPN -M8LN6-M-C -M8LN6-M-C2 -M8LS6-M-C PNP -M8KN6-M5-B -M8KN6-M5-B2 n.a. NPN -M8KN6-M5-C -M8KN6-M5-C2 n.a. PNP -M8LN6-M5-B -M8LN6-M5-B2 n.a. NPN -M8LN6-M5-C -M8LN6-M5-C2 n.a. PNP -M8KN6-M-B -M8KN6-M-B2 n.a. NPN -M8KN6-M-C -M8KN6-M-C2 n.a. PNP -M8LN6-M-B -M8LN6-M-B2 n.a. NPN -M8LN6-M-C -M8LN6-M-C2 n.a. 2 Inductive s

M Size 5. mm 2. mm Shielded Nonshielded Connection Pre-wired Brass * (6) M2 Brass * (-pin) (-pin) Pre-wired Brass * 66 (86) (58) 66 (8) Brass * (58) 66 (8) Brass * (58) 66 (8) (6) (See note.). mm 66 (86) (58) 2. mm (See M2 Brass * note.). mm 66 (8) 2. mm (-pin) Brass * (58) (See note.). mm 66 (8) 2. mm (-pin) Body material Brass * Thread length (overall length) (58) (See note.). mm 66 (8) Output configuration Operation mode NO Operation mode NC Operation mode NO + NC PNP -MKS5-WP-B 2M -MKS5-WP-B2 2M -MKS5-WP-B 2M NPN -MKS5-WP-C 2M -MKS5-WP-C2 2M -MKS5-WP-C 2M PNP -MLS5-WP-B 2M -MLS5-WP-B2 2M -MLS5-WP-B 2M NPN -MLS5-WP-C 2M -MLS5-WP-C2 2M -MLS5-WP-C 2M PNP -MKS5-M-B -MKS5-M-B2 -MKS5-M-B NPN -MKS5-M-C -MKS5-M-C2 -MKS5-M-C PNP -MLS5-M-B -MLS5-M-B2 -MLS5-M-B NPN -MLS5-M-C -MLS5-M-C2 -MLS5-M-C PNP -MKS5-M5-B -MKS5-M5-B2 n.a. NPN -MKS5-M5-C -MKS5-M5-C2 n.a. PNP -MLS5-M5-B -MLS5-M5-B2 n.a. NPN -MLS5-M5-C -MLS5-M5-C2 n.a. PNP -MKS5-M-B -MKS5-M-B2 n.a. NPN -MKS5-M-C -MKS5-M-C2 n.a. PNP -MLS5-M-B -MLS5-M-B2 n.a. NPN -MLS5-M-C -MLS5-M-C2 n.a. PNP -MKN2-WP-B 2M -MKN2-WP-B2 2M -MKN2-WP-B 2M NPN -MKN2-WP-C 2M -MKN2-WP-C2 2M -MKN2-WP-C 2M PNP -MLN-WP-B 2M -MLN-WP-B2 2M -MLN-WP-B 2M NPN -MLN-WP-C 2M -MLN-WP-C2 2M -MLN-WP-C 2M PNP -MKN2-M-B -MKN2-M-B2 -MKN2-M-B NPN -MKN2-M-C -MKN2-M-C2 -MKN2-M-C PNP -MLN-M-B -MLN-M-B2 -MLN-M-B NPN -MLN-M-C -MLN-M-C2 -MLN-M-C PNP -MKN2-M5-B -MKN2-M5-B2 n.a. NPN -MKN2-M5-C -MKN2-M5-C2 n.a. PNP -MLN-M5-B -MLN-M5-B2 n.a. NPN -MLN-M5-C -MLN-M5-C2 n.a. PNP -MKN2-M-B -MKN2-M-B2 n.a. NPN -MKN2-M-C -MKN2-M-C2 n.a. PNP -MLN-M-B -MLN-M-B2 n.a. NPN -MLN-M-C -MLN-M-C2 n.a. *. Material specifications for stainless steel housing case:.5 (W.-No.), SUS (AISI), 26 (SS). Please contact your OMR representative for other stainless steel materials. *2. Please contact your OMR representative for DC 2-wire models. *. Stainless steel models are also available. Please contact your OMR representative. Note:M non-shielded Models with double sensing and short barrels cannot be mounted due to the necessary separation from the surrounding metal. Standard sensing models are thus available.

Connectivity The sensors are available with the following s and cable materials: Pre-wired models Pre-wired models with cable end s Standard cable lengths are 2m and 5m. For other cable lengths please contact your OMR representative. Standard cable material: PVC (dia mm) -WP Other available cable materials and sizes: - PVC (dia 6mm) -WS - PUR/PVC PUR jacket (dia mm) -WA - PUR/PVC PUR jacket (dia 6mm) -WB - PVC robotic cable (dia mm) -WR All pre-wired models can be fitted with cable and s. Standard cable end s: - M2 MJ - ( pin) MJ - ( pin) M5J Other cable end s are available on request. Connector models Standard s: M2, ( or pin) -M, -M, -M5 Inductive s

Model Number Legend @-@@@@@-@-@@-@@ 2 5 6 7 8 9 2 Example: -M2LS-M-B Standard, M2, long barrel, shielded, Sn= mm, M2, PNP-NO -S8KN-WP-B 5M Standard, stainless steel, short barrel, non-shielded, Sn= mm, pre-wired PVC cable, PNP-NO, cable length=5 m. Basic name 8. Kind of connection WP: pre-wired, PVC, dia mm (standard) 2. technology WS: pre-wired, PVC, dia 6mm Blank: Standard double WR: pre-wired, PVC, robotic cable, dia mm. Housing shape and material WA: pre-wired, PUR/PVC (PUR jacket), dia mm M: Cylindrical, metric threaded, brass WB: pre-wired, PUR/PVC (PUR jacket), dia 6mm S: Cylindrical, metric threaded, stainless steel. Housing size M: M2 ( pin) * 8: 8 mm M: ( pin) 2: 2 mm M5: ( pin) 8: 8 mm : mm MJ pre-wired with M2 cable end ( pin) 5. Barrel length MJ pre-wired with cable end ( pin) K: Standard length M5J pre-wired with cable end ( pin) L: Long body 9. Power source and output 6. Shield B: DC, -wire, PNP open collector S: Shielded C: DC, -wire, NPN open collector N: Non-shielded D: DC, 2-wire 7. E: DC, -wire, NPN voltage output Numeral: : e.g. 2=2 mm, 6=6 mm F: DC, -wire, PNP voltage output.operation mode : Normally open (NO) 2: Normally closed (NC) : Antivalent (NO+NC).Specials (e.g., cable material, oscillating frequency) 2.Cable length Blank: Connector type Numeral: Cable length Note: *In case of DC 2-wire models the M2 identifier is '-MG' 5

Specifications DC -wire Models / DC -wire (NO+NC) Item Size M2 Type Shielded Non-shielded Shielded Non-shielded -S8@S2-@@-B -S8@S2-@@-C -S8@N-@@-B -S8@N-@@-C -M2@S-@@-B@ -M2@S-@@-C@ -S2@S-@@-B@ -S2@S-@@-C@ -M2@N8-@@-B@ -M2@N8-@@-C@ -S2@N8-@@-B@ -S2@N8-@@-C@ 2 mm ± % mm ± % mm ± % 8 mm ± % Setting to.6 mm to.2 mm to.2 mm to 6. mm Differential travel % max. of sensing Target Ferrous metal (The sensing decreases with non-ferrous metal.) Standard target (mild steel ST7) 8 8 mm 2 2 mm 2 2 mm 2 2 mm Response frequency,5 Hz, Hz, Hz 8 Hz Power supply voltage (operating voltage range) Current consumption (DC -wire) Output type Control output Indicator 2 to 2 VDC. Ripple (p-p): % max. ( to 2 VDC) ma max. -B models: PNP open collector -C models: NPN open collector Load current 2 ma max. (2 VDC max.) Residual voltage 2 V max. (under load current of 2 ma with cable length of 2 m) Operation indicator (Yellow LED) Operation mode (with sensing object approaching) Protection circuit Ambient air temperature Temperature influence -B/-C models: NO -B2/-C2 models: NC -B/ -C models: NO+NC For details, refer to the timing charts. (See note.) Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Operating: C to 7 C, Storage: C to 85 C (with no icing or condensation) ±% max. of sensing at 2 C within temperature range of 25 C to 7 C ±5% max. of sensing at 2 C within temperature range of C to 7 C Ambient humidity Operating: 5% to 95%, Storage: 5% to 95% Voltage influence ±% max. of sensing in rated voltage range ±5% Insulation resistance 5 MΩ min. (at 5 VDC) between current carry parts and case Dielectric strength, VAC at 5/6 Hz for min between current carry parts and case Vibration resistance to 55 Hz,.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 5 m/s 2, times each in X, Y and Z directions, m/s 2, times each in X, Y and Z directions Standard and listings (See note.) IP67 after IEC 6529 IP69k after DIN 5 EMC after EN697-5-2 Pre-wired models (standard is dia mm PVC cable with length = 2m). Connection method Please see chapter 'Connectivity' for details on different cable materials and lenghts and or M2 s. Weight (packaged) Material Pre-wired model Approx. 65 g Approx. 85 g Connector model M2 models: Approx. 2 g models: Approx. 5 g Approx. 5 g Case Stainless steel Brass-nickel plated or stainless steel surface PBT Cable Standard cable is PVC dia mm. For other cable materials or diameters please refer to chapter 'Connectivity' Clamping nut Brass-nickel plated Brass-nickel plated for brass models stainless steel for steel models Note. The response frequency is an average value. Measurement conditions are as follows: standard target, a of twice the standard target between targets, and a setting of half the sensing. 2. When using any model at an ambient temperature between C and 25 C and a power voltage between and 2 VDC, use a load current of ma max.,. For USA and Canada: use class 2 circuit only.. -B/ -C NO+NC models are available in M2, M8 and M housings with M2 s, pre-wired and with cable end s. 6 Inductive s

DC -wire Models / DC -wire (NO+NC) Item Size M8 M Type Shielded Non-shielded Shielded Non-shielded Non-shielded -M8@S8-@@-B@ -M8@S8-@@-C@ -S8@S8-@@-B@ -S8@S8-@@-C@ -M8@N6-@@-B@ -M8@N6-@@-C@ -S8@N6-@@-B@ -S8@N6-@@-C@ -M@S5-@@-B@ -M@S5-@@-C@ -S@S5-@@-B@ -S@S5-@@-C@ -MKN2-@@-B@ -MKN2-@@-C@ -SKN2-@@-B@ -SKN2-@@-C@ -MLN-@@-B@ -MLN-@@-C@ -SLN-@@-B@ -SLN-@@-C@ 8 mm±% 6 mm±% 5 mm±% 2 mm±% mm±% Setting to 6. mm to 2.8 mm to 2 mm to 6 mm to 2 mm Differential travel % max. of sensing Target Ferrous metal (The sensing decreases with non-ferrous metal.) Standard target (mild steel ST7) 2 2 mm 8 8 mm 5 5 mm 6 6 mm 9 9 mm Response frequency 5 Hz Hz 25 Hz Hz Hz Power supply voltage (operating voltage range) Current consumption (DC -wire) Output type Control output Indicator 2 to 2 VDC. Ripple (p-p): % max. ( to 2 VDC) ma max. -B models: PNP open collector -C models: NPN open collector Load current 2 ma max. (2 VDC max.) Residual voltage 2 V max. (under load current of 2 ma with cable length of 2 m) Operation indicator (Yellow LED) Operation mode (with sensing object approaching) Protection circuit Ambient air temperature Temperature influence -B/-C models: NO -B2/-C2 models: NC -B/ -C models: NO+NC For details, refer to the timing charts. Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Operating: C to 7 C, Storage: C to 85 C (with no icing or condensation) ±% max. of sensing at 2 C within temperature range of 25 C to 7 C ±5% max. of sensing at 2 C within temperature range of C to 7 C Ambient humidity Operating: 5% to 95%, Storage: 5% to 95% Voltage influence ±% max. of sensing in rated voltage range ±5% Insulation resistance 5 MΩ min. (at 5 VDC) between current carry parts and case Dielectric strength, VAC at 5/6 Hz for min between current carry parts and case Vibration resistance to 55 Hz,.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance, m/s 2, times each in X, Y and Z directions Standard and listings (See note.) Connection method Weight (pakkaged) Material IP67 after IEC 6529 IP69k after DIN 5 EMC after EN697-5-2 Pre-wired models (standard is dia mm PVC cable with length = 2m). Please see chapter 'Connectivity' for details on different cable materials and lenghts and or M2 s. Pre-wired model Approx. 6 g Approx. 28 g Approx. 28 g Approx. 7 g Connector model Approx. 7 g Approx. 2 g Approx. 2 g Approx. 26 g Case surface Cable Clamping nut Brass-nickel plated or stainless steel PBT Standard cable is PVC dia mm. For other cable materials or diameters please refer to chapter 'Connectivity' brass-nickel plated for brass models stainless steel for steel models Note. The response frequency is an average value. Measurement conditions are as follows: standard target, a of twice the standard target between targets, and a setting of half the sensing. 2. When using any model at an ambient temperature between C and 25 C and a power voltage between and 2 VDC, use a load current of ma max.. For USA and Canada: use class 2 circuit only. 7

DC 2-wire Models Item Size M2 Type Shielded Non-shielded Shielded Non-shielded -S8@S2-D@ -S8@N-D@ -M2@S-D@ -S2@S-D@ -M2@N8-D@ -S2@N8-D@ 2 mm ± % mm ± % mm ± % 8 mm ± % Setting to.6 mm to.2 mm to.2 mm to 6. mm Differential travel % max. of sensing Target Ferrous metal (The sensing decreases with non-ferrous metal.) Standard target 8 8 mm 2 2 mm 2 2 mm 2 2 mm Response frequency,5 Hz, Hz, Hz 8 Hz Power supply voltage (operating voltage range) Leakage current Output type Control output Indicator (see timing chart) Operation mode Protection circuit Ambient temperature Temperature influence 2 to 2 VDC. Ripple (p-p): % max. ( to 2 VDC).8 ma max. DC 2 wire type Load current to ma Residual voltage V max. (under load current of ma with cable length of 2 m) NO type: Operation indicator (Yellow), Setting indicator (Red) NC type: Operation indicator (Yellow) -D models: NO -D2 models: NC Surget suppressor, Short circuit protection Operating: C to 7 C, Storage: C to 85 C (with no icing or condensation) ±% max. of sensing at 2 C within temperature range of 25 C to 7 C ±5% max. of sensing at 2 C within temperature range of C to 7 C Ambient humidity Operating: 5% to 95%, Storage: 5% to 95% Voltage influence ±% max. of sensing in rated voltage range ±5% Insulation resistance 5 MΩ min. (at 5 VDC) between current carry parts and case Dielectric strength, VAC at 5/6 Hz for min between current carry parts and case Vibration resistance to 55 Hz,.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 5 m/s 2, times each in X, Y and Z directions, m/s 2, times each in X, Y and Z directions Standard and listings (See note.) IP67 after IEC 6529 IP69k after DIN 5 EMC after EN697-5-2 Pre-wired models (standard is dia mm PVC cable with length = 2m). Connection method Please see chapter 'Connectivity' for details on different cable materials and lenghts and or M2 s. Weight (packaged) Material Pre-wired model Approx. 65 g Approx. 85 g Connector model M2 models: Approx. 2 g models: Approx. 5 g Approx. 5 g Case Stainless steel Brass-nickel plated or stainless steel surface PBT Cable Standard cable is PVC dia mm. For other cable materials or diameters please refer to chapter 'Connectivity' Clamping nut Brass-nickel plated Brass-nickel plated for brass models stainless steel for steel models Note. The response frequency is an average value. Measurement conditions are as follows: standard target, a of twice the standard target between targets, and a setting of half the sensing. 2. When using any model at an ambient temperature between C and 25 C and a power voltage between and 2 VDC, use a load current of 5 ma max.. For USA and Canada: use class 2 circuit only. 8 Inductive s

DC 2-wire Models Item Size M8 M Type Shielded Non-shielded Shielded Non-shielded -M8@S8-D@ -S8@S8-D@ -M8@N6-D@ -S8@N6-D@ -M@S5-D@ -S@S5-D@ 8 mm ± % 6 mm ± % 5 mm ± % Setting to 6. mm to 2.8 mm to 2 mm Differential travel % max. of sensing Target Ferrous metal (The sensing decreases with non-ferrous metal.) Standard target 2x2x mm 8x8x mm 5x5x mm Response frequency 5 Hz Hz 25 Hz Hz Power supply voltage (operating voltage range) Leakage current Output type Control output Indicator (see timing chart) Operation mode Protection circuit Ambient temperature Temperature influence 2 to 2 VDC. Ripple (p-p): % max. ( to 2 VDC).8 ma max. DC 2 wire type Load current to ma Residual voltage V max. (under load current of ma with cable length of 2 m) NO type: Operation indicator (Yellow), Setting indicator (Red) NC type: Operation indicator (Yellow) -D models: NO -D2 models: NC Surget suppressor, Short circuit protection Operating: C to 7 C, Storage: C to 85 C (with no icing or condensation) ±% max. of sensing at 2 C within temperature range of 25 C to 7 C ±5% max. of sensing at 2 C within temperature range of C to 7 C -M@N-D@ -M@N2-D@ -S@N-D@ -S@N2-D@ Short body: 2 m ± % Long body: m± % Short body: to 6 mm Long body: to 2 mm Short body: 6x6x mm Long body: 9x9xmm Ambient humidity Operating: 5% to 95%, Storage: 5% to 95% Voltage influence ±% max. of sensing in rated voltage range ±5% Insulation resistance 5 MΩ min. (at 5 VDC) between current carry parts and case Dielectric strength, VAC at 5/6 Hz for min between current carry parts and case Vibration resistance to 55 Hz,.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 5 m/s 2, times each in X, Y and Z directions IP67 after IEC 6529 Standard and listings (See note.) IP69k after DIN 5 EMC after EN697-5-2 Pre-wired models (standard is dia mm PVC cable with length = 2m). Connection method Please see chapter 'Connectivity' for details on different cable materials and lenghts and or M2 s. short body: 28 g Pre-wired model Approx. 6 g Approx. 28 g Weight long body: 7 g (packaged) short body: 2 g Connector model Approx. 7 g Approx. 2 g long body: 26 g Case Brass-nickel plated or stainless steel surface PBT Material Cable Standard cable is PVC dia mm. For other cable materials or diameters please refer to chapter 'Connectivity' Clamping nut brass-nickel plated for brass models stainless steel for steel models Note. The response frequency is an average value. Measurement conditions are as follows: standard target, a of twice the standard target between targets, and a setting of half the sensing. 2. When using any model at an ambient temperature between - C and -25 C and a power voltage between and 2 VDC, use a load current of 5 ma max.. For USA and Canada: use class 2 circuit only. 9

Engineering Data Operating Range (Typical) Shielded Models 8 6 2 Y X 8 6 2 -M@S5 -M8@S8 -M2@S -S8@S2/ -M8@S2 Non-shielded Models 5 Y 25 X 2 5 5 -MLN -MKN2 -M8@N6 -M2@N8 -S8@N/ -M8@N 2 2 Distance Y (mm) 5 2 2 5 Distance Y (mm) Influence of Object Size and Materials Shielded Models -S8@S2 -M2@S/ -S2@S -M8@S8/-S8@S8 2.5 5. 8. @d @d Iron t = mm t = mm X X Iron Iron 7. 2.. Stainless steel 6. Stainless steel (SUS) Stainless steel (SUS) (SUS) 5..5. Brass Brass. Brass Aluminum Aluminum. Aluminum 2.. Copper Copper Copper 2. @d t = mm.5. X. 5 5 2 25 Side length of sensing object d (mm) 5 5 2 25 5 Side length of sensing object d (mm) 2 5 6 Side length of sensing object d (mm) -M@S5/ -S@S5 2 6 2 8 @d t = mm X Iron Stainless steel (SUS) Brass Aluminum Copper 2 5 6 7 8 Side length of sensing object d (mm) Inductive s

Non-shielded Models -S8@N 5. @d t = mm X.. 2.. Iron Stainless steel (SUS) Brass Aluminum Copper -M2@N8/-S2@N8 @d t = mm X 8 6 2 Iron Stainless steel (SUS) Brass Aluminum Copper -M8@N6/-S8@N6 2 @d t = mm X Iron 6 2 Stainless steel (SUS) 8 Brass Aluminum Copper 2 5 Side length of sensing object d (mm) 2 5 Side length of sensing object d (mm) 2 6 8 Side length of sensing object d (mm) -MKN2/-SKN2 25 @d X t = mm Iron 2 5 Stainless steel (SUS) Brass Aluminum Copper 5 -MLN/-SLN 5 @d t = mm Iron X 25 Stainless steel (SUS) 2 Brass 5 Aluminum Copper 5 2 6 8 Side length of sensing object d (mm) 2 6 8 Side length of sensing object d (mm)

Operation DC -wire models PNP Output Operation mode Model Timing chart Output circuit Non-sensing zone object zone Brown +V NO -@-@-B (%) Rated sensing Yellow indicator Control output main circuits Black Blue Load Note : With models, there is no output reverse polarity protection diode. M2 Connector ( pin) V Connector ( pin) 2 2 Note 2: Pin 2 of the M2 and is not used. NC -@-@-B2 Non-sensing zone object (%) Rated sensing zone Yellow indicator Control output main circuits Brown Black ( : ) Blue Load Note : With models, there is no output reverse polarity protection diode. M2 Connector ( pin) +V V Connector ( pin) 2 2 Note 2: Pin of the M2 and is not used. Non-sensing zone object (%) Rated sensing zone main circuits Brown +V Black NO output Load NO + NC -@-@-B Yellow indicator NO output White 2 NC output NC output Blue Load V M2 Connector 2 2 Inductive s

DC -wire models NPN Output Operation mode Model Timing chart Output circuit NO -@-@-C Non-sensing zone object (%) Rated sensing zone Yellow indicator Control output main circuits Brown Black Blue Load Note : With models, there is no output reverse polarity protection diode. M2 Connector ( pin) +V V Connector ( pin) 2 2 Note 2: Pin 2 of the M2 and is not used. NC -@-@-C2 Non-sensing zone object (%) Rated sensing zone Yellow indicator Control output main circuits Brown Black Blue Load Note : With models, there is no output reverse polarity protection diode. M2 Connector ( pin) +V ( : ) V Connector ( pin) 2 2 Note 2: Pin of the M2 and is not used. NO + NC -@-@-C Non-sensing zone object (%) Rated sensing zone Yellow indicator NO output main circuits Brown +V Load Black NO output Load White 2 NC output NC output Blue V M2 Connector 2

DC 2-wire models Output Circuit Diagrams (Operation) Operation mode Model Timing chart Output circuit Non-sensing zone object zone Load Brown +V (%) 8 NO -@-D Rated sensing Yellow indicator Red indicator Control output Load can be connected to +V or V side. M2 Connector 2 Blue V Non-sensing zone object zone Load Brown +V (%) NC -@-D2 Rated sensing Yellow indicator Control output Load can be connected to +V or V side. M2 Connector 2 Blue V Inductive s

Dimensions Note:All units are in millimeters unless otherwise indicated. Pre-wired Models (Shielded) Pre-wired Models (Non-shielded) -S8KS2-WP-@@ 27 5 -S8KN-WP-@@ 27 6 5 5.8 dia. Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m -M2KS-WP-@@/-S2KS-WP-@ 5. 7 7 -M2KN8-WP-@@/-S2KN8-WP-@ 7 7 5. 7 9.2 dia. Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m. for NO+NC (-B / -C) models the total length is mm longer -M8KS8-WP-@@/-S8KS8-WP-@ Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m. for NO+NC (-B / -C) models the total length is mm longer -M8KN6-WP-@@/-S8KN6-WP-@ 2 59.5 9 9 2 59.5 M8 -MKS5-WP-@@/-SKS5-WP-@ 6 6.5 5 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m 5. dia. M8 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m -MKN2-WP-@@/-SKN2-WP-@ 6.5 6 5 5 M.5 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m 26. dia. M.5 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m 5

-S8LS2-WP-@@ 62 9 5 -S8LN-WP-@@ 6 62 9 5 5.8 dia. Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m -M2LS-WP-@@/-S2LS-WP-@ -M2LN8-WP-@@/-S2LN8-WP-@ 72. 72. 7 56 7 7 7 56 7 9.2 dia. Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m -M8LS8-WP-@@/-S8LS8-WP-@ 2 6 8.5 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m -M8LN6-WP-@@/-S8LN6-WP-@ 2 8.5 6 M8 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m -MLS5-WP-@@/-SLS5-WP-@ 86.5 66 6 5 5. dia. M8 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m -MLN-WP-@@/-SLN-WP-@ 86.5 66 6 5 26. dia. M.5 M.5 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m Note. -dia. vinyl-insulated round cable with conductors (conductor cross section:. mm2; insulator diameter:. mm); standard length: 2 m Mounting Hole Cutout Dimensions F External diameter of Dimension F (mm) 8.5 dia. +.5 M2 M8 M 2.5 dia. +.5 8.5 dia. +.5.5 dia. +.5 6 Inductive s

M2 Connector Models (Shielded) M2 Connector Models (Non-shielded) -S8KS2-M-@@ -S8KN-M-@@ 27 5 6 27 5 6 dia. Note: Operation indicator (yellow LED, 9 ) Note: Operation indicator (yellow LED, 9 ) -M2KS-M-@@/-S2KS-M-@ -M2KN8-M-@@/-S2KN8-M-@ 8 8 7 7 7 7 7 9. dia. Note : Operation indicator (yellow LED, 9 ) Note 2: for NO+NC (-B / -C) models the total length is mm longer Note : Operation indicator (yellow LED, 9 ) Note 2: for NO+NC (-B / -C) models the total length is mm longer -M8KS8-M-@@/-S8KS8-M-@ -M8KN6-M-@@/-S8KN6-M-@ 2 9 5 5 9 2 M8 Note: Operation indicator (yellow LED, 9 ) 5. dia. M8 Note: Operation indicator (yellow LED, 9 ) -MKS5-M-@@/-SKS5-M-@ 58 6 5 -MKN2-M-@@/-SKN2-M-@ 58 6 5 5 26.6 dia. M.5 Note: Operation indicator (yellow LED, 9 ) M.5 Note: Operation indicator (yellow LED, 9 ) 7

-S8LS2-M-@@ 65 9 5 -S8LN-M-@@ 6 65 9 5 6 dia. Note: Operation indicator (yellow LED, 9 ) Note: Operation indicator (yellow LED, 9 ) -M2LS-M-@@ -S2LS-M-@ 7 56 7 7 -M2LN8-M-@@ -S2LN8-M-@ 7 7 7 56 7 9.2 dia. Note: Operation indicator (yellow LED, 9 ) Note: Operation indicator (yellow LED, 9 ) -M8LS8-M-@@ -S8LS8-M-@ 2 6 75 75 6 2 -M8LN6-M-@@ -S8LN6-M-@ 5. dia. -MLS5-M-@@ -SLS5-M-@ M8 Note: Operation indicator (yellow LED, 9 ) 8 66 6 5 -MLN-M-@@ -SLN-M-@ 6 M8 Note: Operation indicator (yellow LED, 9 ) 8 66 5 5 26.6 dia. M.5 M.5 Note: Operation indicator (yellow LED, 9 ) Note: Operation indicator (yellow LED, 9 ) Connector Models (Shielded) Connector Models (Non-shielded) -S8KS2-M5-@@/-S8KS2-M-@ 9 27 5 -S8KN-M5-@@/-S8KN-M-@ 9 27 6 5 5.8 dia. Note: Operation indicator (yellow LED, 9 ) Note: Operation indicator (yellow LED, 9 ) -S8LS2-M5-@@/-S8LS2-M-@ 6 9 5 -S8LN-M5-@@/-S8LN-M-@ 6 9 6 5 5.8 dia. Note: Operation indicator (yellow LED, 9 ) Note: Operation indicator (yellow LED, 9 ) Note: Please contact your OMR sales representative for dimension drawings not listed here. 8 Inductive s

Precautions Safety Precautions Power Supply Do not impose an excessive voltage on the, otherwise it may be damaged. Do not impose AC current ( to 2 VAC) on any DC model, otherwise it may be damaged. Load Short-circuit Do not short-circuit the load, or the may be damaged. The s short-circuit protection function will be valid if the polarity of the supply voltage imposed is correct and within the rated voltage range. Correct Use Designing Power Reset Time The is ready to operate within ms (6ms for NO+NC -B / -C types) after power is supplied. If power supplies are connected to the and load respectively, be sure to supply power to the before supplying power to the load. Effects of Surrounding Metal When mounting the within a metal panel, ensure that the clearances given in the following table are maintained. l Wiring Be sure to wire the and load correctly, otherwise it may be damaged. Connection with No Load Be sure to insert loads when wiring. Make sure to connect a proper load to the in operation, otherwise it may damage internal elements. Do not expose the product to flammable or explosive gases. Do not disassemble, repair, or modify the product. Power The may output a pulse signal when it is turned. Therefore, it is recommended that the load be turned before turning the. Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Mutual Interference When installing two or more s face-to-face or side-by-side, ensure that the minimum s given in the following table are maintained. Type Dimension M2 M8 Shielded m l D d dia. Short barrel (Unit: mm) M Long barrel m.5 2 2 5 d --- --- 27 5 D.5 n 2 8 27 5 l 2 5 22 m 8 2 8 7 9 d 2 7 9 2 D 2 5 22 n 2 7 9 2 l n m Type Dimension M2 M8 Short barrel Shielded A 2 6 B 5 2 5 7 Nonshielded Non-shielded (Unit: mm) M Long barrel A 8 2 2 B 6 2 2 Note. In the case of using the supplied nuts. If true flash mounting is necessary, apply a free zone of.5 mm. 2. In the case of using the supplied nuts. If true flush mounting is necessary, apply a free zone of mm. 9

Wiring High-tension Lines Wiring through Metal Conduit: If there is a power or high-tension line near the cable of the, wire the cable through an independent metal conduit to prevent against damage or malfunctioning. Cable Extension Standard cable length is less than 2 m. The tractive force is 5 N. Mounting The must not be subjected to excessive shock with a hammer when it is installed, otherwise the may be damaged or lose its water-resistivity. Do not tighten the nut with excessive force. A washer must be used with the nut. Type Torque Stainless steel type 9 Nm Brass type Nm M2 Nm M8 7 Nm M 8 Nm Maintenance and Inspection Periodically perform the following checks to ensure stable operation of the over a long period of time.. Check for mounting position, dislocation, looseness, or distortion of the and sensing objects. 2. Check for loose wiring and connections, improper contacts, and line breakage.. Check for attachment or accumulation of metal powder or dust.. Check for abnormal temperature conditions and other environmental conditions. 5. Check for proper lighting of indicators (for models with a set indicator.) Never disassemble or repair the. Environment Water Resistivity The s are tested intensively on water resistance, but in order to ensure maximum performance and life expectancy avoid immersion in water and provide protection from rain or snow. Operating Environment Ensure storage and operation of the within the given specifications. Inrush Current A load that has a large inrush current (e.g., a lamp or motor) will damage the, in which case connect the load to the through a relay. <SUITABILITY FOR USE> OMR shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer s application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. <CHANGE IN SPECIFICATIS> Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMR representative at any time to confirm actual specifications of purchased product. ALL DIMENSIS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by.97. To convert grams into ounces, multiply by.527. Cat. No. DE-EN-2A In the interest of product improvement, specifications are subject to change without notice. 2 Inductive s