DOW Ultrafiltration. Case History. High Turbidity and Temperature Fluctuation No Obstacle for DOW Ultrafiltration

Similar documents
FILMTEC Membranes Strategies for Using FILMTEC Elements to Lower Your Total Cost of Seawater Desalination

A meaningful, cost-effective solution for polishing reverse osmosis permeate

Lenntech. Dow Water Solutions. FILMTEC Membranes. Product Information Catalog

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

Technical Paper Presented at Southwest Chemistry Workshop, Farmington, NM, June 23-24, 2009

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

Basics of Reverse Osmosis

PERFORMANCE TESTING OF A 380 ML/D RETROFITTED MEMBRANE/UV OXIDATION WTP. Introduction

Water Treatment and Reverse Osmosis Systems

Innovation and Progress in Water Treatment Technology

MEMCOR membranes for drinking water applications. Water Technologies

MEMBRANE TECHNOLOGY TREATING OILY WASTEWATER FOR REUSE

Use of Color Removal Membranes on Waste Water Treatment in the Pulp and Paper Industry

Reverse Osmosis Membranes for Wastewater Reclamation By Craig R. Bartels, PhD Hydranautics, 401 Jones Road, Oceanside California, USA 92054

HUBER Vacuum Rotation Membrane VRM Bioreactor

Nine Industrial Scale V SEPs. Feed Tank V SEP. Feed Pumps (Three) Concentrate. Tank. V SEP Treatment System

Wastewater Reuse. Typical treated wastewater is:

Microfiltration for Removal of Manganese from Surface Water

Pall Aria Integrated MF/RO Systems for Cost-Effective Treatment of Sea and Brackish Waters

Dow Water Solutions. FILMTEC Reverse Osmosis Membranes. Understanding RO Element Salt Rejection Specifications. June 2004

Indiana s Newest Filtration Facility; East Chicago

TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES

CHEMICAL CLEANING EXPERIMENTS FOR PERFORMANCE RESTORATION OF NF MEMBRANES OPERATED ON SEAWATER FEED 1

By: Curt Roth Vice President, Engineering EconoPure Water Systems, LLC. Point of Use/Point of Entry Treatment with LFNano. An EconoPure White Paper

Hollow Fiber Cleaning and Storage Procedure

INTEGRATED MEMBRANE SYSTEMS. Introduction

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS

Using EDI to Meet the Needs of Pure Water Production

EASTERN IRRIGATION SCHEME, VICTORIA: OPERATION OF AN ULTRA-FILTRATION PLANT FOR A CLASS A RECYCLED WATER SCHEME. David Aitken. Earth Tech Engineering

Seccua Product Presentation

The Grand Miramare Hotel Santa Margherita (Portofino) Italy March 19 22, Inspiring Innovation and Excellence

Dow Liquid Separations DOWEX MARATHON MSA. Ion Exchange Resin. Engineering Information

1. Inspection and monitoring... 3

GUIDELINES FOR SELECTING RESIN ION EXCHANGE OR REVERSE OSMOSIS FOR FEED WATER DEMINERALISATION

Technology Selection Tools for Boiler Feedwater Applications (US Units)

CWD BALDWIN PLANT NEW RESIDUALS HANDLING SYSTEM

Development of Advanced Wastewater Treatment and Reclamation System

Removing Heavy Metals from Wastewater

Pall Aria AP Series Packaged Water Treatment Systems

How To Remove Iron From Water

Mine Water Treatment Solutions for Discharge and Re-Use

To meet the demands of a high-purity deionized (DI) water system, filters must:

Carbon Dioxide and Dissolved Oxygen Removal From Makeup Water By Gas Transfer Membranes

RO / NF Cleaning Guidelines

How To Water System

RO Reverse Osmosis equipments

Complete. Water Solutions. for Rural India

Effective Deoxygenation by a Hybrid Process Combining Gas Transfer Membranes with Catalytic Oxygen Reduction

DOWEX Resins as Organic Solvent Desiccants

Troubleshooting Your RO

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction

Water Softening for Hardness Removal. Hardness in Water. Methods of Removing Hardness 5/1/15. WTRG18 Water Softening and Hardness

REVERSE OSMOSIS PROCESS AND SYSTEM DESIGN. H. Ohya Department of Chemical Engineering, Yokohama National University, Japan

inge watertechnologies AG Innovative Ultrafiltration technology Josef Wunram

Advanced Water Treatment and Membrane Technology in Japan

In recent years, the city of Boca Raton has

Amiad s AMF² pre-treatment technology ensures efficient and reliable nanofiltration of Scottish Highland loch water

Application Note NEW LOGIC RESEARCH. Treating Fuel Storage Tank Bottom Water With VSEP. Overview

ADVANCED TREATMENT OF RAINWATER USING METAL MEMBRANE COMBINED WITH OZONATION

Municipal Standard Solutions. Water Treatment WATER TECHNOLOGIES

MARBELLA SEAWATER DESALINATION PLANT: CONSTRUCTION AND START - UP EXPERIENCE. Juan María Sánchez, Juan Velasco, Jose M. Kindelan and Jaime Andreu

INTERSTAGE ENERGY RECOVERY TURBINE APPLICATION MARCO ISLAND, FLORIDA

Dow Liquid Separations DOWEX MARATHON A. Ion Exchange Resin ENGINEERING INFORMATION

Life Sciences USD High Purity Water Systems for the Biopharmaceutical Industry. Improving security, flexibility and operation costs

ITT Water Equipment Technologies. ITT Flowtronex. Water Equipment Technologies & Flowtronex

ETC -SV. Class 0 oil-free compressed air through catalysis

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

Case Study: Research Leads To Large-Scale Microfiltration Plants 10/01/1999

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

The use of ultrafiltration in the public drinking water supply in Germany

Silica Over-Saturation, Precipitation, Prevention and Remediation In Hot Water Systems Edited By Dave Peairs, Cal Water, Technical Director

ASSESSMENT OF WASTEWATER TREATMENT AND WATER REUSE PRACTICES IN THE GULF COUNTRIES

AQUCAR PS 75 Water Treatment Microbiocide

James City Service Authority Five Forks Water Treatment Facility

Cartridge Filter Application Notes

Membrane filtration of surface water for the removal of humic substances

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS

7 Years Operation of BWRO Plant with Raw Water from Coastal Aquifer for Agriculture Irrigation

Enhanced Organic Precursor Removals Using Aged Filter Media Page 1. Enhanced Organic Precursor Removals Using Aged Filter Media

Water Treatment. Session Objectives

Comparison of Advanced Treatment Methods for Partial Desalting of Tertiary Effluents

OF EOR CHEMICALS. Ying Guo, Total E&P. Presented at FORCE - EOR Competence Building Workshop 6. November 2013

Differentiation Summary. Revolutionizing Water Clean-Up Opportunities

Water... The essence of life

Drinking water for Gaza Elaboration concept 2

FILMTEC. Membranes. The Economics of Reverse Osmosis and Ion Exchange. Dow Liquid Separations. WATERTECH Expo '94 November 9-11, 1994 Houston, Texas

Membrane Types and Factors Affecting Membrane Performance

ROSS Technology Removal of Oil, Solids and Scale Formers

Tampa Bay Seawater Desalination Plant

Contamination. Cleanroom. Cleanroom for micro and nano fabrication. Particle Contamination and Yield in Semiconductors.

Case Study: Optimizing Scale Inhibition Costs in Reverse Osmosis Desalination Plants

PRINCIPLES AND PRACTICES OF REVERSE OSMOSIS

Cross Flow Filtration Method Handbook

UPCORE System. Suspended Solids Removal for Countercurrent Ion Exchange Systems

VIPCLEAN Via Goretta 96/A Mappano di Caselle (TO) Tel Fax

Case Study NEW LOGIC RESEARCH. Using Vibrating Membranes to Treat Oily Wastewater from a Waste Hauling Facility

DRINKING WATER - LAB EXPERIMENTS. Coagulation and flocculation LAB EXPERIMENTS. Jartest

Expansion of Water Recycling Business in Dubai, Middle East

Transcription:

Case History High Turbidity and Temperature Fluctuation No Obstacle for Site Information Location: HeBei, China Capacity: 12 m 3 /h (5283 gpm) Purpose: Pretreat sea water prior to RO system Time in Operation: Since 25 Performance: Turbidity <.2 NTU; SDI < 2 Skids of modules in the HeBei facility. (Photo courtesy of HeBei DaTang WangTang International HuaTan Electricity Co. Ltd.) Introduction HeBei DaTang WangTang International HuaTan Electricity Co. Ltd. is located in the harbor commercial development area in the province of HeBei. WangTang has a production capacity of over 4 million kw. In 26, the two-phase coastal electricity stations produced up to 25 billion kwh of electricity. Reverse osmosis (RO) technology is used to desalinate sea water for boiler make-up water supply and other industrial water needs. The raw water source presented two significant challenges for the system designer: high turbidity and wide temperature fluctuation. Due to the rise and fall of tides, the sea water turbidity oscillates greatly on a daily basis. The temperature range is about 27 C between the hottest and the coldest months. membranes were able to overcome the challenges and demonstrate reliable performance, resulting in product water with turbidity averaging less than.2 NTU and silt density index (SDI) averaging less than 2. Page 1 of 5 TMTrademark of The Dow Chemical Company ( Dow ) or an affiliated company of Dow Form No. 795-2-118

DOW Ultrafiltration Modules The SFP-266 module is particularly ideal for systems with capacities of 5 m 3 /h (22 gpm) or less, although customers with larger facilities also choose this module because of construction or economic constraints. At 6 inches (15 cm) diameter, the SFP-266 module allows a more compact, alternative design for space-constrained installations. modules are made with high-strength, hollow-fiber membranes that have excellent features and benefits:.3 μm nominal pore diameter for removal of bacteria, viruses, and particulates (including colloids) to protect downstream processes such as reverse osmosis Polyvinylidene fluoride (PVDF) polymeric hollow fibers for high strength and chemical resistance that lead to longer membrane life Hydrophilic PVDF fibers for easy cleaning and wettability that help maintain long-term performance Outside-in flow configuration for high tolerance to feed solids that helps reduce the need for pretreatment processes Unplasticized polyvinylchloride (U-PVC) housing, which helps eliminate the need for costly pressure vessels Water Treatment Process Table 1 indicates the average raw water analysis. Raw water turbidity varies from 2 to 1 NTU. Table 1. Raw water analysis. Parameter Unit Value Fe 2+ mg/l.25 Fe 3+ mg/l.7 Turbidity NTU <1 Temperature C 13 Total suspended solids (TSS) mg/l 5 Total organic content (TOC) mg/l 4. Oil mg/l 1.2 ph 8. Non-active SiO2 mg/l 22.5 Figure 1 is a diagram of the water treatment process. Raw water is diverted from the bay area of the Yellow Sea. The sea water s chemical oxygen demand (COD) level is less than 1 mg/l and turbidity decreases to 1 NTU at the raw water inlet. Thus, no coagulation is needed for pretreatment. Only an oxidizing agent (sodium hypochlorite, NaOCl) is used to disinfect the raw water. Figure 1. Water treatment process. NaOCl NaHSO 3, antiscalant, HCl NaOH Sea Water Disc Filter DOW TM Ultrafiltration Cartridge Filter 1 st Pass FILMTEC RO Cartridge Filter 2 nd Pass FILMTEC RO Ion Exchange Boiler Make-up Industrial Water Page 2 of 5 TMTrademark of The Dow Chemical Company ( Dow ) or an affiliated company of Dow Form No. 795-2-118

Water Treatment Process, cont. The disc filter is able to filter out large molecules and prevent irreversible damage to the membrane. A 2-µm disc filter is used to achieve a self-controlled wash at hourly intervals at a design turbidity of 15 NTU. Sodium bisulfite (NaHSO 3 ) is dosed at 3 ppm to remove any residual oxidizing agent remaining in the water. An antiscalant is dosed at 1 ppm to prevent RO membrane scaling. The cartridge filters prevent particles from transferring into the treated water and damaging the membrane. Five-micron polypropylene filters with a flow capacity of 6 m 3 /h each are used for the cartridge filters. Sodium hydroxide (NaOH) is added to the RO feed to achieve an optimal ph for RO feed water between 6 and 9. A portion of the first-pass RO water is used for other industrial purposes. The remaining water goes through a second-pass RO and ion exchange resin to obtain water ready for boiler make-up supply. Table 2 provides the operating parameters for the ultrafiltration and reverse osmosis unit operations. Table 3 further describes the ultrafiltration process. Table 2. Operating parameters for unit operations. Parameter Unit Disc Filter UF 1 st Pass RO 2 nd Pass RO Component SFP-266 FILMTEC SW3HR LE-4i FILMTEC BW3-4 Capacity m 3 /h 12 12 45 315 (84+36) Number of skids 3 7+3 3 3 Number of modules per skid 6 Total number of modules 6 Capacity per skid m 3 /h 4 12 15 15 Recovery % 95 Design flux L/m 2 h 6 Table 3. Ultrafiltration operating process. Parameter Frequency Duration Chemical Consumption Filtration 56 min 56 min Air scour 56 min 4 6 s Backwash 56 min 4 min 15 ppm NaOCl Forward flush 56 min 6 s CEB a None None CIP b 8 months 6 h Alkaline:.5% NaOH,.2% NaOCl Acid:.36% HCl a Chemically Enhanced Backwash b Clean-in-Place Figure 2 shows the raw feed water turbidity fluctuation over a 4-month period. Feed water turbidity varied greatly from about 3 to 1 NTU. However, the product water turbidity was approximately.2 NTU and never exceeded.3 NTU (right scale). The two zero data points for the feed water were due to the failure of the turbidity meter and are not related to the UF performance. The outside-in flow configuration of the modules enabled the UF system to meet the challenge of wide-ranging feed water turbidity and produce a stable RO feed water. Page 3 of 5 TMTrademark of The Dow Chemical Company ( Dow ) or an affiliated company of Dow Form No. 795-2-118

UF System Performance Figure 2. Product and raw water turbidity versus time. 1 1. 8.8 Feed 6 4 Feed Water NTU Product Water NTU.6.4 Product 2.2 288 576 864 1152 144 1728 216 234 2592 288 Hour. Figure 3 is a plot of flow pressure index (FPI) vs time for the skid. The FPI is defined as the permeate flow divided by the transmembrane pressure (TMP). A constant FPI value indicates a good and stable UF operation performance. Figure 3 shows the FPI is mostly constant for nearly 2 years operation. The FPI decreased in May 26 and CIP was performed in August to restore the UF performance. The FPI increased after CIP, indicating that the membrane is easy to clean. Chemically enhanced backwash (CEB) was not performed during the time period studied. Only one clean-in-place (CIP) was performed after 8 months of operation since installation. The backwash frequency was greater than 3 minutes, further demonstrating UF as an economic choice for RO pretreatment. Figure 3. Flow pressure index versus time. 5 45 Flow Pressure Index 4 35 3 25 2 15 1 5 12/14/5 12/22/5 12/27/5 1/12/6 1/22/6 2/12/6 2/21/6 2/28/6 3/24/6 4/3/6 4/1/6 7/6/6 7/13/6 CIP 7/21/6 8/22/6 11/1/6 6/2/7 Page 4 of 5 TMTrademark of The Dow Chemical Company ( Dow ) or an affiliated company of Dow Form No. 795-2-118

UF System Performance, cont. Figure 4 indicates that the product water SDI value did not exceed 2.1 and ranged from.75 to 2.. Although the feed water turbidity fluctuated widely, the product water SDI value remained below 2 for the majority of the time, producing excellent feed water to the sea water RO unit. Figure 4. Average UF product water SDI versus time. 2.5 Permeate SDI15 2 1.5 1.5 24 48 816 1152 1488 1824 216 2496 Hour Summary modules met the challenge of high turbidity and fluctuating water temperature to produce acceptable feed water for the WangTang power plant. The only pretreatment required for the modules is a disc filter, resulting in the elimination of coagulation, sedimentation, or media filtration unit operations. The outside-in flow configuration of the ultrafiltration module makes this possible. modules provide an economical and effective solution for sea water desalination and have produced water with SDI averaging less than 2 and turbidity averaging less than.2 NTU over three years of operation. This further enhances and ensures the performance of the RO system, resulting in optimal flux, high salt rejection, and high recovery. The UF system and RO system only require chemical cleaning once every 8 and 6 months, respectively, further indicating the reliability of the as a pretreatment to seawater RO. For more information about DOW Ultrafiltration, call the Dow Water Solutions business: North America: 1-8-447-4369 Latin America: (+55) 11-5188-9277 Europe: (+32) 3-45-224 Japan: (+81) 3-546-21 Australia: (+61) 3-9226-3545 http://www.dowwatersolutions.com Notice: The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system. Notice: No freedom from any patent owned by Seller or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer s use and for ensuring that Customer s workplace and disposal practices are in compliance with applicable laws and other governmental enactments. Seller assumes no obligation or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. Page 5 of 5 TMTrademark of The Dow Chemical Company ( Dow ) or an affiliated company of Dow Form No. 795-2-118