ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1



Similar documents
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

Fabcograte FRP Grating. Tolerances: ±1/16. Tolerances: ±1/16. THICKNESS BAR SPACING PANEL SIZE (FT.) WT (LBS) 1" 1.5" x 1.

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

FRP Grating, Handrail, Guidelines for Ladders & the Engineer Structural and Designer Shapes

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION PREFORMED METAL STANDING SEAM ROOFING

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

SECTION METAL WALL PANELS

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

GigaCrete Specification PlasterMax

Product Guide Specification

SECTION GROUND WATER STORAGE TANKS

SECTION PRECAST CONCRETE STRUCTURES

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

Wastewater Capital Projects Management Standard Construction Specification

Preformed Metal Roofing and Siding

PART 1 GENERAL 1.1 SECTION INCLUDES

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

SECTION STANDING SEAM METAL ROOFING

2. Division 05 Structural Steel Framing for steel framework requirements

SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.

SECTION GUARDRAILS

Dynarail Guardrail, Handrail & Ladder

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Autobody/Collision and Repair Technology/Technician CIP Task Grid

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

Engineering Specifications

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.

FIBREGRATE Grating PRODUCT CATALOGUE. How is FIBREGATE made? What is FIBREGATE Grating? FIBREGATE Product Gallery GRATING

SECTION GUARDA SECURITY WINDOW SCREENS

Destiny Shower Enclosure Installation Instructions

A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

JANUARY 1, 2015 AVAILABILITY LIST

Division 9. SignaFlor Pad and Pour Flooring System

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

Code of Standard Practice for Timber Frame Structures

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

EcoTouch Insulation with PureFiber Technology

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

City of San Diego, CWP Guidelines

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

TARIFF CODE and updates standard

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

EXPANDED METAL & GRATING

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

CLEAR-DIVISIONS CENTERFOLD

Specifications, Product Testing and Terminology

COMMERCIAL ITEM DESCRIPTION CLOTH AND STRIP, LAMINATED OR COATED, VINYL NYLON OR POLYESTER, HIGH STRENGTH, FLEXIBLE

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

DENVER MODEL 30 X 30 SPECIFICATIONS

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS

Sun Vinyl New Construction Windows Homeowner's Warranty

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

How To Compare Roofing Material

SECTION 1 GENERAL REQUIREMENTS

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

Acrylic Walls Installation Instructions

Section SEWER PIPE INSTALLATION AND TESTING

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

CHAPTER 13 LOAD HOOKS

Document Library TS Data Sheet

SECTION PLAYGROUND SURFACING TILES

COLORADO MODEL. 35 x 65 SPECIFICATIONS

SECTION WINDOW WASHING SYSTEMS

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Rudder Repair and refinish

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Asphalt Shingle Application Requirements

ITEM # OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT

Pro-Lift Steel Pile Foundation Repair

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

SECTION CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

Table of Contents PRODUCTS. DYE SUB POP UP CANOPIES P. 3-4 Dye Sublimated Canopy... Attract Customers, Increase Brand Awareness & Say it in Color!

High Strain Dynamic Load Testing of Drilled Shafts

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

LiftAlloy Chain Slings

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

TechCut 4 Precision Low Speed Saw

SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP)

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

Fiberglass Rebar (GFRP Rebar)

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

Blister Repair with Binding Resin for Spas, Marine and Gel Coat Structures

Selecting Vinyl Flooring

SECTION PRECAST CONCRETE UTILITY STRUCTURES

BENTLEY ELEMENTS COLLECTION LVT

CLEAR-DIVISIONS APERTO

Transcription:

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING January 24, 2014 06610-1

SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING PART 1 - GENERAL 1.1 SCOPE OF WORK A. The CONTRACTOR shall furnish, fabricate (where necessary), and install all fiberglass reinforced plastic (FRP) items, with all appurtenances, accessories and incidentals necessary to produce a complete, operable and serviceable installation as shown on the Contract Drawings and as specified herein, and in accordance with the requirements of the Contract Documents. 1.2 REFERENCES A. The publications listed below (latest revision applicable) form a part of this specification to the extent referenced herein. The publications are referred to within the text by the designation only. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) Test Methods: ASTM D 635 Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastics in a Horizontal Position ASTM E 84 Surface Burning Characteristics of Building Materials NSF/ANSI STANDARD 61 1.3 CONTRACTOR SUBMITTALS A. The CONTRACTOR shall furnish shop drawings of all fabricated gratings and accessories in accordance with the provisions of this Section. B. The CONTRACTOR shall furnish manufacturer's shop drawings clearly showing material sizes, types, styles, part or catalog numbers, complete details for the fabrication and erection of components including, but not limited to, location, lengths, type and sizes of fasteners, clip angles, member sizes, and connection details. C. The CONTRACTOR shall submit the manufacturer s published literature including structural design data, structural properties data, grating load/deflection tables, corrosion resistance tables, certificates of compliance, test reports as applicable, concrete anchor systems and their allowable load tables, and design calculations for systems not sized or designed in the contract documents. D. The CONTRACTOR may be requested to submit sample pieces of each item specified herein for acceptance by the ENGINEER as to quality and color. Sample pieces shall be manufactured by the method to be used in the WORK. January 24, 2014 06610-2

1.4 QUALITY ASSURANCE A. All items to be provided under this Section shall be furnished only by manufacturers having a minimum of ten (10) years experience in the design and manufacture of similar products and systems. Additionally, if requested, a record of at least five (5) previous, separate, similar successful installations in the last five (5) years shall be provided. B. Manufacturer shall offer a 3 year limited warranty on all FRP products against defects in materials and workmanship. C. Manufacturer shall be certified to the ISO 9001-2008 standard. D. Manufacturer shall provide proof of certification from at least two other quality assurance programs for its facilities or products (DNV, ABS, USCG, AARR). E. Manufacturer shall provide proof, via independent testing, that materials proposed as a solution do not contain heavy metals in amounts greater than that allowed by current EPA requirements. 1.5 PRODUCT DELIVERY AND STORAGE A. Delivery of Materials: Manufactured materials shall be delivered in original, unbroken pallets, packages, containers, or bundles bearing the label of the manufacturer. Adhesives, resins and their catalysts and hardeners shall be crated or boxed separately and noted as such to facilitate their movement to a dry indoor storage facility. B. Storage of Products: All materials shall be carefully handled to prevent them from abrasion, cracking, chipping, twisting, other deformations, and other types of damage. Adhesives, resins and their catalysts are to be stored in dry indoor storage facilities between 70 and 85 degrees Fahrenheit (21 to 29 degrees Celsius) until they are required. PART 2 - PRODUCTS 2.1 MANUFACTURER A. Molded gratings shall be Fibergrate as manufactured by Fibergrate Composite Structures Inc. 5151 Belt Line Road, Suite 1212 Dallas, Texas 75254-7028 USA (800) 527-4043 Phone (972) 250-1530 Fax Website: www.fibergrate.com E-mail: info@fibergrate.com 2.2 GENERAL A. All FRP items furnished under this Section shall be composed of fiberglass reinforcement and resin in qualities, quantities, properties, arrangements and dimensions as necessary to meet the design requirements and dimensions as specified in the Contract Documents. January 24, 2014 06610-3

B. Fiberglass reinforcement shall be continuous roving in sufficient quantities as needed by the application and/or physical properties required. C. Resin shall be {Vinyl Ester, Isophthalic Polyester, Polyester, Vinyl Ester used to produce NSF Standard 61 certified grating, Isophthalic Polyester used to produce NSF Standard 61 certified grating or Modified Acrylic - choose one}, with chemical formulations as necessary to provide the corrosion resistance, strength and other physical properties as required. D. All finished surfaces of FRP items and fabrications shall be smooth, resin-rich, free of voids and without dry spots, cracks, crazes or unreinforced areas. All glass fibers shall be well covered with resin to protect against their exposure due to wear or weathering. E. All fire-retardant molded grating products shall have a tested flame spread rating of 25 or less per ASTM E-84 Tunnel Test. Gratings shall not burn past the 25 mm reference mark and will be classified HB per ASTM D635. F. All grating products shall be certified to NSF/ANSI Standard 61 {use only if choosing a resin system that can be used to produce gratings to the NSF Standard 61 in sections 2.2 C & 2.3 E} G. All mechanical grating clips shall be manufactured of Type 316SS (stainless steel). 2.3 MOLDED FRP GRATING A. Manufacture: Grating shall be of a one piece molded construction with tops and bottoms of bearing bars and cross bars in the same plane. Grating shall have (a square mesh pattern providing bidirectional strength or a rectangular mesh pattern providing unidirectional strength - choose one). Grating shall be reinforced with continuous rovings of equal number of layers in each direction. The top layer of reinforcement shall be no more than 1/8" below the top surface of the grating so as to provide maximum stiffness and prevent resin chipping of unreinforced surfaces. Percentage of glass (by weight) shall not exceed 35% so as to achieve maximum corrosion resistance, and as required to maintain the structural requirements of the CONTRACT. After molding, no dry glass fibers shall be visible on any surface of bearing bars or cross bars. All bars shall be smooth and uniform with no evidence of fiber orientation irregularities, interlaminar voids, porosity, resin rich or resin starved areas. B. Non slip surface (select one): Grating shall be manufactured with a concave, meniscus profile on the top of each bar providing maximum slip resistance. OR Grating shall be manufactured with an integrally applied grit to the top surface of each bar providing maximum slip resistance. C. Grating bar intersections are to be filleted to a minimum radius of 1/16 to eliminate local stress concentrations and the possibility of resin cracking at these locations. D. Fire rating: Grating shall be fire retardant with a tested flame spread rating of 25 or less when tested in accordance with ASTM E 84. Data performed only on the resin shall not be acceptable. E. Resin system: The resin system used in the manufacture of the grating shall be {Vi-Corr, FGI-AM, Corvex, ELS, XFR or Super Vi-Corr - choose one, use NSF specialty formula for NSF Standard 61 certified products}. January 24, 2014 06610-4

F. Manufacturer may be required to submit corrosion data from tests performed on actual grating products in standard chemical environments. Corrosion resistance data of the base resin from the manufacturer is not a true indicator of grating product corrosion resistance and shall not be accepted. G. Color: {varies by resin - consult your catalog}. H. G. Depth: " with a tolerance of plus or minus 1/16". I. H. Mesh Configuration: " x " with a tolerance of plus or minus 1/16" mesh centerline to centerline. J. Load/Deflection: Grating design loads shall be less than manufacturers published maximum recommended loads. Maximum recommended loads shall be determined by acoustic emission testing. Grating shall be designed for a uniform load of 100 psf or concentrated load of 300 lb. Deflection is not to exceed 0.375 or L/D = 120, whichever is less. K. The manufacturer shall certify that the stiffness of all panels manufactured are never more than 2.5% below the published load-deflection values. L. Substitutions: Other products of equal strength, stiffness, corrosion resistance and overall quality may be submitted with the proper supporting data to the engineer for approval. 2.4 GRATING FABRICATION A. Measurements: Grating supplied shall meet the dimensional requirements and tolerances as shown or specified. The Contractor shall provide and/or verify measurements in field for work fabricated to fit field conditions as required by grating manufacturer to complete the work. When field dimensions are not required, contractor shall determine correct size and locations of required holes or cutouts from field dimensions before grating fabrication. B. Layout: Each grating section shall be readily removable, except where indicated on drawings. Manufacturer to provide openings and holes where located on the contract drawings. Grating openings which fit around protrusions (pipes, cables, machinery, etc.) shall be discontinuous at approximately the centerline of opening so each section of grating is readily removable. C. Sealing: All shop fabricated grating cuts shall be coated with vinyl ester resin to provide maximum corrosion resistance. All field fabricated grating cuts shall be coated similarly by the contractor in accordance with the manufacturer's instructions. D. Hardware: Type 316 stainless steel hold-down clips shall be provided and spaced at maximum of four feet apart with a minimum of four per piece of grating, or as recommended by the manufacturer. PART 3 - EXECUTION 3.1 INSPECTION A. Shop inspection is authorized as required by the Owner and shall be at Owner's expense. The fabricator shall give ample notice to Contractor prior to the beginning of any fabrication work so that inspection may be provided. The grating shall be as free, as commercially possible, from visual defects such as foreign inclusions, delamination, blisters, resin burns, air bubbles and pits. The surface shall have a smooth finish (except for grit top surfaces). January 24, 2014 06610-5

3.2 INSTALLATION A. Contractor shall install gratings in accordance with manufacturer s assembly drawings. Fasten grating panels securely in place with hold-down fasteners as specified herein. Field cut and drill fiberglass reinforced plastic products with carbide or diamond tipped bits and blades. Seal cut or drilled surfaces in accordance with manufacturer's instructions. Follow manufacturer's instructions when cutting or drilling fiberglass products or using resin products; provide adequate ventilation. January 24, 2014 06610-6