COMMERCIAL ITEM DESCRIPTION CLOTH AND STRIP, LAMINATED OR COATED, VINYL NYLON OR POLYESTER, HIGH STRENGTH, FLEXIBLE
|
|
|
- Sabina Ramsey
- 9 years ago
- Views:
Transcription
1 INCH-POUND A-A May 13, 1997 COMMERCIAL ITEM DESCRIPTION CLOTH AND STRIP, LAMINATED OR COATED, VINYL NYLON OR POLYESTER, HIGH STRENGTH, FLEXIBLE The General Services Administration has authorized the use of this commercial item description in preference to MIL-C Scope. This document covers three types, three classes and two forms of laminated or coated cloth. The cloth is intended for use in the manufacture of protective covers and tarpaulins; the laminated strip is intended for nuclear pipe insulation. 2. Classification. The cloth shall be in the following types, classes and forms: Type I - Heavy Duty Type II - Medium Duty Type III - Light Duty Class 1 - Regular Class 2 - Special Class 3 - Special laminated construction Form 1 - Cloth (width as specified) Form 2 - Strip, 3 inches wide 3. Salient Characteristics. 3.1 Description. The base cloth shall be an open mesh woven or weft inserted warp knit nylon or polyester cloth. The polyvinylchloride material shall not contain water soluble ingredients; only phosphate and phthalate ester plasticizers shall be used for the purpose of mildew resistance. 3.2 Laminated or Coated cloth. The polyvinylchloride material shall be applied to both sides of the base cloth. The face side of the finished cloth shall be comparatively smooth and the back side may be rough (areas located over the points at which the yarns cross will be raised and the areas between the yarns will be depressed). The physical properties of the finished cloth (and the strip in cloth form prior to being cut into strip) shall conform to the requirements specified in Table I when tested as specified. Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data which may improve this document should be sent to: Defense Personnel Support Center, Clothing and Textiles Directorate, Attn: DPSC-FNS, 00 South 20th Street, Philadelphia, PA AMSC N/A FSC 8305 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
2 3.3 Color. The color of the finished cloth shall match the applicable color number of FED- STD-595 or shall match the approved color standard for the color specified where such a sample is applicable. The color of the finished cloth shall match the standard sample when viewed under filtered tungsten lamps that approximate artificial daylight and that have a correlated color temperature of K, with illumination of footcandles and shall be a good match to the standard sample under incandescent lamplight at K. 3.4 Physical Requirements The cloth shall conform to the requirements listed in Table I. Table I Requirements of finished cloth Type I Type II Type III Characteristic Weight oz/yd 2 Maximum Minimum Breaking Strength lbs. (min.) Initial After abrasion After accelerated weathering 1/ Tearing Strength lbs. (min.) Hydrostatic Resistance, psi (min) Stiffness, cm (max) At 70 o F At 20 o F Adhesion of coating, face side lbs/2 inch width (min) Flame Resistance 2/: warp & fill: After flame sec (max) Char length in. (max) Blocking, scale rating (max) / After accelerated weathering, the finished cloth shall show no sign of delamination or of becoming stiff or brittle, nor shall the film or coating become soft or tacky. 2/ For materials required to meet NFPA requirements, see and Flame resistance (NFPA). When specified, the cloth shall meet the flame resistance requirements stated in NFPA 701 (Small Scale Test). 3.5 Workmanship. The finished cloth shall conform to the quality of product established by this document. The occurrence of defects shall not exceed the applicable acceptable quality levels.
3 3.6 Width. The overall width of the finished cloth shall be as specified width tolerance shall be + 1/2 inch. The overall width of the finished strip shall be 3 + 1/4 inches. 3.7 Component and material inspection. Components and materials shall be inspected in accordance with all the requirements of referenced documents, unless otherwise excluded, amended, modified or qualified in this document or applicable purchase document. In addition, testing shall be performed for the characteristics specified in Table III. All test reports shall contain the individual values utilized in expressing the final result. The sample unit shall be 1/2 yard full width of the cloth. The lot size shall be expressed in units of 1 yard and the sample size shall be as specified below. The lot shall be unacceptable if one or more sample units fail to meet any requirement specified. Lot size - yards Sample size (sample unit) 800 or less up to and including 22, ,001 and over 5 4. Regulatory requirements. The offeror/contractor is encouraged to use recovered materials to the maximum extent practicable, in accordance with paragraph.403 of the Federal Acquisition Regulations (FAR). 5. QUALITY ASSURANCE PROVISIONS 5.1 Product conformance. The products provided shall meet the salient characteristics of this commercial item description, conform to the producer's own drawings, specifications, standards and quality assurance practices and be the same product offered for sale in the commercial market. The Government reserves the right to require proof of such conformance. 5.2 Market acceptance criteria. The item offered, or a generic equivalent, must have been sold to the commercial market or to the Government for at least two years. 5.3 Warranty. The item offered shall include the standard warranty given to the commercial market beginning with the date of delivery of the individual terms. 5.4 End item tests. The finished cloth shall be tested for the characteristics listed in Table II. The methods of testing specified shall be followed. The physical values specified apply to the average of determinations made on a sample unit for test purposes as specified in the applicable test methods. The sample unit shall be 3, continuous yards full width of the finished cloth. The lot shall be unacceptable if one or more sample units fail to meet any test requirements specified. The lot size shall be expressed in units of one yard each. All test reports shall contain the individual values utilized in expressing the final result. The sample size (number of sample units) shall be in accordance with the following: Lot size - yards Sample size 800 or less up to and including 22, ,001 and over 5 3
4 Weight Characteristics Breaking strength: Initial After abrasion After accelerated weathering Table II End item tests Tearing Strength 4/ Hydrostatic resistance 5/ Stiffness at 70 o + 2 o F at 20 o + 5 o F Adhesion of coating 8/ Flame resistance 9/ Blocking 10/ Test method ASTM-D-3776 Method C (small swatch of fabric method) ASTM-D-5034 (G-E or G-T) 1/ and 2/ 3/ and 2/ 6/ 7/ and 6/ 1/ Abrasion resistance. ASTM-D-57. Type I and II cloths shall be abraded on the face side with 80 grit garnet paper. Five determinations each from the warp and filling shall be made per sample unit. Breaking strength specimens shall be cut from the center of the abraded strips. Type III shall be abraded on the face side with a 220 grit paper. 2/ Breaking strength after conditioning. ASTM-D-5035, procedure 1C-E or 1C-T. 3/ Accelerated weathering procedure. Two specimens, 8 by 6 inches minimum, with the short dimension warpwise and two specimens, 8 by 6 inches, minimum, with the short dimension filling wise shall be subjected to the procedure specified in Method 5804 of FED- STD-191, with filters. The procedure shall be performed with the face side exposed for a period of 150 hours + 1 hour. After exposure, the specimens shall be removed and allowed to condition for at least 24 hours. One warpwise and one fillingwise specimen shall be visually inspected. The remaining specimens shall be tested for breaking strength. 4/ Tearing strength. ASTM-D-2261 or ASTM-D One maximum peak load shall be recorded. The machine shall tear a minimum distance of 3 inches. The force necessary to tear the cloth shall be observed by means of an autographic recording device. In case of failure by yarn pull-out, rather than yarn breakage, specimens shall be cut 8 by 11 inches. The speed of the movable clamp of the testing machine shall be 12 inches per minute. 5/ Hydrostatic resistance. ASTM D-1, Hydrostatic Resistance Procedure A (Pressure Application by Mullen Type Hydrostatic Tester, Procedure 1 using a machine with displacement rate of 85 ml/min. The water pressure shall be applied to the face side of the cloth. 6/ Stiffness. TAPPI Method T-1, Preferred Procedure (1). 7/ Stiffness at low temperature. Specimens and equipment shall be conditioned at the specified temperature for a minimum of 4 hours before testing. Tests shall be performed at the specified temperature and in still air. 4
5 8/ Adhesion of coating. ASTM-D-1, Adhesion of Coating with 2 inch wide reinforced coating adhesion specimens, cyanoacrylate (solventless) adhesive, and pulling clamp speed of 5 mm/s. The test shall be performed on the face side of the cloth. 9/ Flame resistance. Method 53 of FED-STD-191 unless NFPA testing is required. When NFPA testing is required, the test shall be conducted in accordance with NFPA 701, Small Scale Test. 10/ Blocking. ASTM D-1, Determination of Blocking Resistance of Fabrics Coated With Rubber or Plastics at Elevated Temperatures, except that test specimens shall be exposed at an oven temperature of 180 F for 30 minutes. 5.5 Yard-by-yard examination. The required yardage of each roll in the sample shall be examined on one side only for the defects listed below, however the side shall be alternated for every other roll examined (except type III, class 5 cloth). The same yardage shall be given a through-light inspection for pinholes and thinly coated areas. The through-lighting inspection shall be performed in accordance with MIL-STD The defects found shall be counted regardless of their proximity to each other, except where two or more defects represent a single local condition of the cloth, in which case only the more serious defect shall be counted. A continuous defect shall be counted as one defect for each warpwise yard or fraction thereof in which it occurs. The sample unit shall be 1 linear yard. 5.6 Defects. The cloth shall be examined for the following defects: Any hole, cut, pinhole, tear, scratch or abrasion mark; Any blister or delamination; Any lump; Any crease or wrinkle resulting in fold, pleat or doubling or adhesion of surfaces that cannot be corrected by manual pressure; Any film or coating missing to expose the base cloth; Any spot, stain or streak more than 1 inch in combined directions, clearly visible at normal inspection distance (3 feet); Any objectionable odor (odors of chemicals commonly used in coating compounds shall not be regarded as objectionable); Width specified not within a tolerance of + 1/2 inch; Broken or missing yarn clearly visible at normal inspection distance (3 feet) by either direct viewing or through-lighting; 3 or more contiguous broken or missing yarns of any length; Crease or wrinkle of single ply film or coating or any crease wrinkle or bunching of base cloth that cannot be corrected by manual pressure; Any embedded foreign matter clearly visible at normal inspection distance (3 feet); by either direct viewing or through-lighting; Color not as specified; Color not uniform or is mottled, blotchy or spotted; Uneven thickness of film or coating clearly noticeable. Any tackiness (film or coating shall not block so as to cause surfaces to adhere and not unroll readily); Edges rolled, folded, scalloped, or corded; Not evenly laminated or coated. 5.7 Length examination. Each individual roll in the sample shall be examined for the defects listed below. If the total number of defects in the sample roll exceeds the maximum number of defects specified below, the lot shall be rejected. Any roll containing more than two pieces. Any piece in roll less than 25 yards. Any roll with a total length of less than 80 yards or more than 125 yards. Any roll with a total length more than two yards less than that marked on ticket. End of pieces in roll not overlapped. End of pieces in roll joined by a seam. 5.8 Acceptance criteria. Acceptance criteria shall be as specified in the contract or purchase order. 5
6 6. PACKAGING 6.1 Preservation, packing and marking. The preservation, packing and marking shall be as specified in the contract or order. 7. NOTES 7.1 Source of Government Documents. Copies of Military and Federal documents are available from: Standardization Documents Order Desk Bldg. 4D 700 Robbins Avenue Philadelphia, PA Sources of Nongovernment Documents. AMERICAN SOCIETY FOR TESTING AND MATERIALS (Applications for copies should be addressed to the American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA ) NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) NFPA Fire Tests for Flame Resistant Textiles and Films (Applications for copies should be addressed to the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269) Custodian: Army - GL Navy - NU Air Force - 99 Civil Agency Coordinating Activity: GSA - FSS Preparing Activity: DLA - CT Review Activities: Army - AT Air Force - Project No
COMMERCIAL ITEM DESCRIPTION RUBBER, SILICONE
INCH-POUND A-A-59588 January 12, 2001 SUPERSEDING ZZ-R-765E/GEN May 10, 1989 COMMERCIAL ITEM DESCRIPTION RUBBER, SILICONE The General Service Administration has authorized the use of this commercial item
COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET
[METRIC] A-A-59135 28 OCTOBER 1997 SUPERSEDING PPP-C-1752D(3) 1 FEBRUARY 1993 COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET The General Services Administration has authorized the use of this commercial
COMMERCIAL ITEM DESCRIPTION CUSHIONING MATERIAL, PACKAGING, CLOSED CELL FOAM PLANK
[METRIC] A-A-59136 28 OCTOBER 1997 SUPERSEDING PPP-C-1752D(3) 1 FEBRUARY 1993 COMMERCIAL ITEM DESCRIPTION CUSHIONING MATERIAL, PACKAGING, CLOSED CELL FOAM PLANK The General Services Administration has
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING January 24, 2014 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING PART 1 - GENERAL 1.1 SCOPE OF WORK A. The CONTRACTOR
Standard Specification for Polyvinyl Chloride (PVC) and Other Organic Polymer-Coated Steel Chain-Link Fence Fabric 1
Designation: F 668 07 Standard Specification for Polyvinyl Chloride (PVC) and Other Organic Polymer-Coated Steel Chain-Link Fence Fabric 1 This standard is issued under the fixed designation F 668; the
GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA 19033-1208 USA TEL (610) 522-8440 FAX (610) 522-8441 GII GAI GCI. GRI Test Method GM21
Geosynthetic Institute 4 Kedron Avenue Folsom, PA 133-1208 USA TEL (610) 522-8440 FAX (610) 522-8441 GEI GRI GSI GAI GCI GII Revision 4: December 17, 2012 Revision schedule on pg. 11 GRI Test Method GM21
COMMERCIAL ITEM DESCRIPTION INK, MARKING, STENCIL, OPAQUE (POROUS AND NON-POROUS SURFACES)
[Metric] A-A-208C July 19, 2012 Superseding A-A-208B November 20, 1995 COMMERCIAL ITEM DESCRIPTION INK, MARKING, STENCIL, OPAQUE (POROUS AND NON-POROUS SURFACES) This Commercial Item Description is approved
SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS
PART 1 GENERAL SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS 1.1 SUMMARY A. Optically clear dual reflective, neutral sputtered and aluminum metallized polyester film for solar control. 1.2 RELATED
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES 1 PART 1 - GENERAL 1.0 GENERAL 1.1 REFERENCES: SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED FIBERGLASS
40 years of quality & service. SINTEPLAST, S.A. de C.V. TARPAULIN
SINTEPLAST, S.A. de C.V. TARPAULIN Econoplast Tarpaulin 9 x 6 1000 D. Specially designed for outdoor uses. Its excellent physical and mechanical proprieties make it one of the most versatile materials.
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use
1.4 Metallic Impurities Iron must not exceed 150 ppm and copper shall not exceed 6 ppm when tested according to TAPPI T 266.
Library of Congress Preservation Directorate Specification Number 100 132 09 Specifications for 3 x 10ʺ Paper Enclosures For the Storage of Strip Photographic Negatives This specification is provided as
IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality
IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION Generated: Sergiy Papyshev Engineering Approved: Don Prysi Manufacturing Approved: Merzuk Ramic Quality Approved: Steven Barnett Administrative DATE DATE DATE
CHAPTER 6 ASPHALT ROLL ROOFING
CHAPTER 6 ASPHALT ROLL ROOFING Section I. DESCRIPTION AND GENERAL DISCUSSION 6.1.1 General 6.1.3 Mineral-Surfaced Asphalt roll roofing is roofing in sheet form Mineral-surfaced roll roofing is composed
Product Guide Specification
Reef Industries, Inc. 9209 Almeda Genoa Rd. Houston, Texas 77075 Toll Free (800) 231-6074 Phone (713) 507-4251 Fax (713) 507-4295 Web Site www.reefindustries.com E-Mail [email protected] Product Guide
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification Number: 3503-11.2.610 Rev. 2 Rubber Lined Steel Pipe and Fittings Mechanically Coupled Plain End Type System Issued Revised Approved
1.1.2 Polypropylene The polypropylene must be a white opaque film, 1 2 mil thick. Biaxial orientation is preferred.
Library of Congress Preservation Directorate Specification Number 700 704 09 Specifications for Pressure Sensitive Adhesive Labels For Application to Single Paper Sheets and Text Pages of Bound Books For
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS 1. Paragraph 1.02 Provide solid surface countertops at sinks locations. Provide solid surface window sills at drywall framing walls.
COATING & WRAPPING OF UNDERGROUND PIPING
CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification
FEDERAL SPECIFICATION BEADS (GLASS SPHERES) RETRO-REFLECTIVE
INCH-POUND TT-B-1325D 10 July 2007 SUPERSEDING TT-B-1325C June 1, 1993 FEDERAL SPECIFICATION BEADS (GLASS SPHERES) RETRO-REFLECTIVE The General Services Administration has authorized the use of this federal
Specifications, Product Testing and Terminology
Specifications, Product Testing and Terminology The following synopsis provides a review of various material and final product testing, which is performed on our products, as well as, many of our competitors.
Standard Specification for Flat Glass 1
: C 1036 06 Standard Specification for Flat Glass 1 This standard is issued under the fixed designation C 1036; the number immediately following the designation indicates the year of original adoption
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE PART 1: GENERAL 1.01 SECTION INCLUDES PVC pressure pipe and fabricated fittings in nominal sizes 4-inches through 12-inches with cast iron pipe equivalent
DETAIL SPECIFICATION CHEMICAL CONVERSION COATINGS ON ALUMINUM AND ALUMINUM ALLOYS
NOT MEASUREMENT SENSITIVE MIL-DTL-5541F 11 July 2006 SUPERSEDING MIL-C-5541E 30 November 1990 DETAIL SPECIFICATION CHEMICAL CONVERSION COATINGS ON ALUMINUM AND ALUMINUM ALLOYS This specification is approved
Quality assurance of flex circuits in the SCT barrel hybrid production
Quality assurance of flex circuits in the SCT barrel hybrid production ATLAS Project Document No. Institute Document No. Created: dd/mm/yy Modified: dd/mm/yy Page: 1 of 11 DRAFT Quality assurance of flex
GENERAL RUBBER LINING PRINCIPLES
GENERAL RUBBER LINING PRINCIPLES I. METAL PREREQUISITES Metal to be lined should meet the requirements as stated in section 8 Metal Fabrication and section 12 Blasting and Cementing Procedures. The surface
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.
13310 FABRIC SHADE STRUCTURES FOR PLAYGROUND AREAS ************************************************************************************************************************ SPECIFIER: CSI Master Format
Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description
Product Data Sheet Edition 15/10/2014 Identification no: 02 07 04 10 300 0 000002 SikaProof A Edge SikaProof A-08 Edge, A-12 Edge Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing
GRI Test Method GM13* Test Methods, Test Properties and Testing Frequency for High Density Polyethylene (HDPE) Smooth and Textured Geomembranes
Geosynthetic Institute 475 Kedron Avenue Folsom, PA 19033-1208 USA TEL (610) 522-8440 FAX (610) 522-8441 GEI GRI GSI GAI GCI GII GRI Test Method GM13* Revision 14: January 6, 2016 Revision schedule on
REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542
1.0 INTENT REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES 1.01 It is the intent of this specification to provide for the reconstruction of pipelines and conduits by the installation of a resin-impregnated
How to Build a Printed Circuit Board. Advanced Circuits Inc 2004
How to Build a Printed Circuit Board 1 This presentation is a work in progress. As methods and processes change it will be updated accordingly. It is intended only as an introduction to the production
GENERAL GUIDELINES AND TECHNICAL SPECIFICATIONS OF UNIFORM FABRICS FOR MGVCL EMPOLYEES FOR BLOCK YEAR 2011-2013
/ GENERAL GUIDELINES AND TECHNICAL SPECIFICATIONS OF UNIFORM FABRICS FOR MGVCL EMPOLYEES FOR BLOCK YEAR 2011-2013 MADHYA GUJARAT VIJ COMPANY LTD. REGISTERED OFFICE: SARDAR PATEL VIDYUT BHAVAN, RACE COURSE,
SEAMS SEAMING USING SEAM TAPE
SEAMING USING SEAM TAPE SEAMS The membrane should be positioned so that the width of the seam is 3. Remove excess chalk from a chalk line by snapping the line into the air and then chalk a line one-quarter
FEDERAL SPECIFICATIONS. Beads (Glass Spheres) Retro-Reflective
NOTICE OF VALIDATION INCH-POUND TT-B-1325D NOTICE 1 17-May-2012 FEDERAL SPECIFICATIONS Beads (Glass Spheres) Retro-Reflective TT-B-1325D, dated 06-Aug-2007, has been reviewed and determined to be valid
Standard Specification for Tool Steel High Speed 1
Designation: A 600 92a (Reapproved 2004) Standard Specification for Tool Steel High Speed This standard is issued under the fixed designation A 600; the number immediately following the designation indicates
VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised
Page 1 of 6 instructions VC 104+ Rigid Grade / VC 104+ Rigid Grade Imagine / (for the rest of this document referred to as VC 104) can be applied to new and used trucks and trailers with painted rigid
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
A. This Section includes rubberized asphalt sheet membrane waterproofing systems.
SECTION 07110 SHEET MEMBRANE WATERPROOFING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
Colorado State University. Durrell Center Roof Repair
Colorado State University Durrell Center Roof Repair SPECIFICATION: POLYURETHANE FOAM ROOFING l.0 GENERAL REQUIREMENTS The successful application of a polyurethane foam roofing system is dependent upon
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.
SPECIFICATION Allowed anodization before fabrication for clear frames. Page 2 of 9 1. SCOPE 1.1. This document provides general requirements for aluminum frames used in the assembly of photovoltaic modules.
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION PART 1 GENERAL.01 SECTION INCLUDES Furnishing and installing 4 inch through 16 inch high density
Standard Specification for Tool Steels Alloy 1
Designation: A 68 8 Standard Specification for Tool Steels Alloy This standard is issued under the fixed designation A 68; the number immediately following the designation indicates the year of original
SECTION 33 05 16.13 PRECAST CONCRETE UTILITY STRUCTURES
SECTION 33 05 16.13 PRECAST CONCRETE PART 1 - GENERAL 1.01 SECTION INCLUDES A. This item shall consist of the construction of both sanitary and storm sewer precast concrete manholes in accordance with
DIRECT PRINTING NYLON JACKETS. The Basics
DIRECT PRINTING NYLON JACKETS The Basics . The Nylon Jacket Types of Nylon There are three basic weaves that are commonly used to manufacture nylon jackets or outerwear. These are Taffeta, Satin and Oxford.
GigaCrete Specification PlasterMax
GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application
Division 9. SignaFlor Pad and Pour Flooring System
Division 9 SignaFlor Pad and Pour Flooring System SPECIFICATIONS Page 1. General... 2 1.1 Description 2 1.2 Quality Assurance 2 1.3 Submittals 2 1.4 Delivery and Storage 3 1.5 Warranty 3 1.6 Working Conditions
SECTION 32 1816 PLAYGROUND SURFACING TILES
SECTION 32 1816 PLAYGROUND SURFACING TILES PART 1 GENERAL 1.01 SECTION INCLUDES A. Resilient playground safety surfacing tiles. B. Coordinate with work shown in other sections so the work is installed
Electrical Safety Products
Electrical Safety Products Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg
SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)
Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised ) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular blocks
Pilkington Reflite Handling and Processing Guidelines Solar Control
Pilkington Reflite Handling and Processing Guidelines Solar Control Pilkington Reflite 1. Product description Pilkington Reflite is a hard, on-line coated, solar control glass, available in a range of
Table of Contents PRODUCTS. DYE SUB POP UP CANOPIES P. 3-4 Dye Sublimated Canopy... Attract Customers, Increase Brand Awareness & Say it in Color!
PRODUCTCATALOG Table of Contents PRODUCTS DYE SUB POP UP CANOPIES P. 3-4 Dye Sublimated Canopy... Attract Customers, Increase Brand Awareness & Say it in Color! TEARDROP BANNERS P. 9-10 Ideal for both
Columbia flooring will resist fading from exposure to sunlight or artificial light.
LIMITED LIFETIME WARRANTY AND MAINTENANCE FOR RESIDENTIAL USE Columbia is so confident in the design and durability of our Columbia flooring products and accessories, that we back them with a Limited Lifetime
SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS
Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications
800-457-2369 www.portabledisplaybooths.com
We look forward to working with you to design a Trade Show Exhibit Booth, Graphics & Promotional Items that will make your Trade Show experience a SUCCESS! Miriam & Makara 800-457-2369 www.portabledisplaybooths.com
Peel Adhesion of Pressure Sensitive Tape
Harmonized International Standard Call Letters PSTC 101 Date of Issuance 10/00 Revised 10/03 Revised 05/07 Peel Adhesion of Pressure Sensitive Tape 1. SCOPE 1.1 These methods cover the measurement of the
IPC-SM-840C. Qualification and Performance of Permanent Solder Mask IPC-SM-840C. The Institute for. Interconnecting. and Packaging Electronic Circuits
The Institute for Interconnecting and Packaging Electronic Circuits Qualification and Performance of Permanent Solder Mask January 1996 A standard developed by the Institute for Interconnecting and Packaging
Medical Silicone Tubing & Hose
Medical Silicone Tubing & Hose Peroxide or Platinum Cured Fluid Transfer Specialists Silcon Medical Medical Grade Silicone Tubing Finished product meets USP Class VI requirements Manufactured under good
AMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
PROCESS GUIDE LINES: LAYUP AND CURE OF EPOXY PREPREG. Easycure E-710 AND Easycure E-710FR MATERIALS 160-250 F CURING OVEN/VACUUM PROCESS
PROCESS GUIDE LINES: LAYUP AND CURE OF EPOXY PREPREG Easycure E-710 AND Easycure E-710FR MATERIALS 160-250 F CURING OVEN/VACUUM PROCESS TABLE OF CONTENTS 1 Mold Preparation... 3 2 Cutting and Lay-up...
Installation Instructions for Fletco Carpets
Table of Contents The backing is a very important part of a carpet, as well as the installation and the daily use are concerned, so therefore these installations instructions are based on the different
Application Instructions for Avery Dennison Films SF100-843-S LTR EZ RS, Conform Chrome
Application Instructions for Avery Dennison Films SF100-843-S LTR EZ RS, Conform Chrome Instructional Bulletin #4.00.2 (Revision 0) Dated: 04/05/2012 1.0 Consult Product Data Bulletin Before starting application,
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SMAA-2P-8xE UPGRADE SMOOTH SURFACE / CAP SHEET / SINGLE PLY 2 PLY POLYESTER REINFORCED ACRYLIC
1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.
CAST IN PLACE DETECTABLE/TACTILE WARNING SURFACE TILE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Special Conditions and Division 1 Specifications
SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP)
SPECIFICATIONS INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP) Part 1 General 1.1 CONFORMITY Conforms to the requirements of the general conditions of the contract.
Standard Specification for Polyethylene Plastics Molding and Extrusion Materials 1
Designation: D 4976 04a Standard Specification for Polyethylene Plastics Molding and Extrusion Materials 1 This standard is issued under the fixed designation D 4976; the number immediately following the
GENERAL TRADING TERMS (GTT) RMC by EUROSURFACES
GENERAL TRADING TERMS (GTT) RMC by EUROSURFACES PART I GENERAL COMMERCIAL CONDITIONS FOR THE SALE OF AGGLOMERATED STONE RMC by EUROSURFACES Manufacturer: Product Brand: EUROSURFACES PORTUGAL S.A. RMC Rua
MILITARY SPECIFICATION PRINTED WIRING BOARD, FLEXIBLE OR RIGID-FLEX GENERAL SPECIFICATION FOR
The document and process conversion Measures necessary to comply with This revision shall be completed by 30 September 2001. INCH-POUND MIL-P-50884D 28 December 2000 SUPERSEDING MIL-P-50884C 4 May 1984
POLYURETHANE LINING AND COATING ON PIPE RAW WATER
POLYURETHANE LINING AND COATING ON PIPE RAW WATER PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2
BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.
BOQ SPECIFICATIONS VERTICAL BLINDS Vertical Blinds made of glass fibre fabrics in width 5 (or 4 ). Minimum overlapping of ¾ in fabric. Top aluminium anodized rail of 1.4 mm thickness. 2 inch wide channel
SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)
SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO) 1 Intent: The intent of trenchless sewer pipe Insertion is to rehabilitate the existing sewer
PAAM COMMERCIAL PRIVATE LIMITED
METAL PACKAGING We at Paam Group have been providing vast range of packaging products to our customers based on their preferences, needs and specifications. We provide all the materials required in metal
T 549. WORKING GROUP CHAIRMAN N/A; reaffirmed SUBJECT RELATED
NOTICE: This is a DRAFT of a TAPPI Standard in ballot. Although available for public viewing, it is still under TAPPI s copyright and may not be reproduced or distributed without permission of TAPPI. This
Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems
Pipe and Equipment Insulations Zeston PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems Zeston PVC Insulated Fitting Covers Installation Instructions for Hot,
SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING. 16.1 General...16-1. 16.2 Materials...16-1. 16.3 Equipment...
SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING TABLE OF CONTENTS 16.1 General...16-1 16.2 Materials...16-1 16.3 Equipment...16-1 16.4 Installation...16-2 16.4.1 Traffic Restrictions...16-2
The corrugated box: A profile and introduction
The corrugated box: A profile and introduction 1 More than just a plain brown box Ninety to ninety-five percent of U.S. manufactured goods are shipped to consumers in corrugated containers. In fact, more
4. Cryogenic gloves are generally designed to protect the hands from intense cold or heat.
PROTECTIVE GLOVES In many University laboratories, exposure to chemicals, infectious agents, sharp objects, extreme temperatures and other hazards can create a potential for injury to the hand. Wherever
TABLE OF CONTENTS INTERIOR BANNER DISPLAYS 2-4 LIGHT BOX DISPLAYS 5 EXTERIOR SIGN DISPLAYS 6 HARDWARE 7-9
DISPLAY CATALOG TABLE OF CONTENTS 2-4 LIGHT BOX DISPLAYS 5 EXTERIOR SIGN DISPLAYS 6 7-9 Whether you need a small yard sign or an oversized banner display, look to Signs and Graphics by FedEx Office to
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
SECTION 15190 HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section 15010.
SECTION 15190 HVAC INSULATION PART ONE - GENERAL PART 1 - GENERAL 1.01 DESCRIPTION A. All work specified in this Section is subject to the provisions of Section 15010. B. All insulation products shall
HOSE AND TUBING CATALOGUE SOLD BY THE ROLL OR IN INCREMENTS OF 1M, STANDARD COIL LENGTH 30 METRES. SIZE (I.D x WALL) CODE SIZE (I.
FUEL LINE Temperature: -40 C to +125 C continuous service. Tube: Type C (Nitrile). Black. Oil and petrol resistant. Reinforcement: Single ply of synthetic fibre. Cover: Type C2 (NBR/PVC). Black. Fuel,
City of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
EUROPEAN STANDARDS PERSONAL PROTECTIVE CLOTHING FOR FLAME RESISTANT. Alexander Gstettner, Lenzing AG Austria
EUROPEAN STANDARDS FOR FLAME RESISTANT PERSONAL PROTECTIVE CLOTHING Alexander Gstettner, Lenzing AG Austria W a t e r How are the standards organized? A 1 Testing Methods Standards specifiying performance
A. Work on this project shall consist of, but is not limited to, the following:
PART 1 - GENERAL CLEANING AND RESTORATION OF SECTION 05900-1 1.1 SUMMARY A. Work on this project shall consist of, but is not limited to, the following: 1. Clean and treat all exposed anodized architectural
SEWING MAINTENANCE CHECKLIST
SEWING MAINTENANCE CHECKLIST Many Retail, Brand-name Marketing, Mail Order and Sourcing Companies are visiting existing and potential Contractor sewing facilities and evaluating their sewing capabilities
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,
Introduction... 3 Setting the Combination... 4 Securing the DEFCON CL... 5 Locking the DEFCON CL to your Notebook Computer...
notebook security DEFCON CL cable lock USER GUIDE Visit our Website at www.targus.com Features and specifications subject to change without notice. 2006 Targus Group International, Inc. and Targus, Inc.
Peel & Seal Self-Stick Roofing Solutions
Peel & Seal Self-Stick Roofing Solutions Ideal for Low Slope Applications Waterproof and Weatherproof Energy Efficient Tough and Durable Versatile, Effective Sealing Around Protrusions Perfect for Vents,
Technical Data Sheet February 2014
Scotch-Weld Technical Data Sheet February 2014 Product Description s are high performance, two-part acrylic adhesives that offer excellent shear, peel, and impact performance. These toughened products
COMPARISON BETWEEN MECHANICAL PROPERTIES OF FABRICS WOVEN FROM COMPACT AND RING SPUN YARNS
COMPARISON BETWEEN MECHANICAL PROPERTIES OF FABRICS WOVEN FROM COMPACT AND RING SPUN YARNS Alsaid. A. Almetwally 1 and Mona. M. Salem 2 Textile Division, National Research Centre, Egypt 1 e-mail: [email protected]