In addition to the basic models, it is also possible for the units to be outfitted with add-ons.



Similar documents
Single- and Multi-circuit Pumps

MANTA Piston Distributor for Oil and Fluid Grease

3/2-way Solenoid Valve, direct-acting, NC or NO

Product series DSA, DSB, DSC, DSD

4/2-Way Pneumatic Solenoid Valve

3/2-way Mini Solenoid Valve

Assisted lift operated 2/2-way solenoid valves Type EV250B

SINGLE LINE CRENTRALIZED LUBRICATION SYSTEM

Series description: Wilo-Drain TC 40

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

3/2-way pneumatic cartridge solenoid valve

2/2 and 3/2 Way Size 6 Seat Valves

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

AIR OPERATED OIL PUMPS AND KITS

Lubricant distributors

Series TMM Axial Piston Motor. Technical Information

OLI. Oil level indicator

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

3/2- and 2/2-way cartridge valve type BVE

CRN A-F-G-E-HQQE 3x400D 50 HZ

Centro-Matic Automatic Lubrication Systems System Controls

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

System 8. ü ( System 8

Solenoid valves 2/2-way direct-operated Type EV210A

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Plastic tube flowmeters Series PT/PS

Rickmeier Solutions. Gear pumps for superior Lubrication

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Hydraulic control unit series

MEMBRANE VACUUM MINI PUMPS

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Oil + Air-Lubrication System

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Pressure Switch for gas and air

Instruction Manual. T3111 T3111L T3111P T3111Ex

Lincoln Multi-line and progressive systems

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Linear actuator Econom 0. Our intelligent model: Econom 0. Econom 0

Single sub-base valve

Pressure transmitter For general industrial applications Model A-10

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Pressure Relief Valves SPV, SPVF

Instruction Manual Differential Pressure Transmitter

Fluxi 2000/TZ Turbine Gas Meter

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Radial piston pumps type R and RG

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

How To Use A Flowmeter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Conlift1, Conlift2, Conlift2 ph+

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

4 Posiflow Proportional Solenoid Valves

Pressure regulating valve with modulating kit, type DRV

HERZ-Thermal Actuators

RM/55401/M, Roundline cylinder Magnetic piston, double acting

Hydraulic Flow Control Valves

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Type 3353 Angle Seat Valve

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Oil - kerosene burners

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Solenoid Valve Island Type 3965

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Solenoid valves Type EVU

Actuators and Sensors. Products

PUMP AND MOTOR DIVISION

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

servo-controlled 3-WaY vacuum solenoid valves WiTH

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

Transcription:

1-1202-EN Gear ump Units For single-line centralized lubrication systems MFE5-KW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated, single-line centralized lubrication systems. The basic setup includes a gear pump unit with motor, a 3 or 6 liter lubricant reservoir, metal or plastic, or a 15 liter metal reservoir and float switch to monitor the minimum permissible level of lubricant. In addition to the basic models, it is also possible for the units to be outfitted with add-ons. Special models for a wide variety of applications are listed in the overview table on page 3.

min. pressure switch group DS-W 001 003 006 010 016 003 006 010 1 2 3 4 5 345-4 piston distributor, assembly 340 1 2 3 343-4 measuring terminal max. pressure switch group DS-W 003 1 metering unit assembly 320 gear pump unit MFE5-BW7-S62 003 1 003 1 T1 M S R dosages in 1/100 ccm Example of a single-line central lubrication system for an automobile manufacturing plant The system consists essentially of: a gear pump unit 6 liter metal reservoir piston distributors, assembly 340 metering units, assembly 320 pressure switches, group DS-W for max. pressure build-up and relief pressure 2 1-1202-EN

Overview table for gear pump units See important product usage information on the back cover. Order No. Reservoir capacity Reservoir material Design features [liters] MFE5-KW3-2 3 lastic Basic version with WS32-2 float switch MFE5-KW3-2-S4 3 lastic Basic version with WS35-2 float switch MFE5-KW3-2-S9 3 lastic For oil as 5 mm 2 /s at max. 16 bars MFE5-KW3-2-S13 3 lastic Unit for 50/95 weatherproofing (DIN 50015); WS32-2 float switch MFE5-KW3-S24 3 lastic Motor with HAN6ES Harting connector; WS35-S30 float switch MFE5-BW3-2 3 Metal Basic version with WS32-2 float switch MFE5-BW3-2-S14 3 Metal French Automotiv version (CNOMO); WS35-2 float switch; Stäubli filler coupling MFE5-BW3-2-S22 3 Metal For oil as 5 mm 2 /s at max. 16 bars MFE5-BW3-2-S34 3 Metal Motor UL/CSA MFE5-BW3-2-S37 3 Metal Basic version with WS35-2 float switch MFE5-BW3-S41 3 Metal Motor with HAN6ES Harting connector; WS35-S30 float switch MFE5-KW6 6 lastic Basic version with WS32-2 float switch MFE5-KW6-S1 6 lastic Basic version with WS35-2 float switch MFE5-KW6-S8 6 lastic FKM (FM) version, WS32-S8 float switch MFE5-KW6-S33 6 lastic Motor with HAN6ES Harting connector; WS35-S30 float switch MFE5-BW7 6 Metal Basic version with WS32-2 float switch MFE5-BW7-CF 6 Metal Basic version with WS35-2 float switch MFE5-BW7-S8 6 Metal FKM (FM) version, WS32-S8 float switch MFE5-BW7-S22 6 Metal Motor UL/CSA MFE5-BW7-S29 6 Metal French Automotiv version (CNOMO); WS35-2 float switch; Stäubli filler coupling MFE5-BW7-S54 6 Metal Unit for 50/95 weatherproofing (DIN 50015); WS32-2 float switch MFE5-BW7-S120 6 Metal VW version MFE5-BW7-S98 6 Metal VW version with filler coupling MFE5-BW7-S107 6 Metal Motor with HAN6ES Harting connector; WS35-S30 float switch MFE5-BW15 15 Metal Basic version with WS32-2 float switch; wall-mounted reservoir MFE5-BW16 15 Metal Basic version with WS35-2 float switch; wall-mounted reservoir MFE5-BW15-S7 15 Metal Basic version with WS35-2 float switch; foot-mounted reservoir MFE5-BW16-S93 15 Metal Motor with HAN6ES Harting connector; WS35-S30 float switch 1-1202-EN 3

Gear pump unit mounted separate from oil reservoir Order No. ME5 Fig. 1 Fig. 2 Gear pump unit for flange-mounting on oil reservoir Order No. MFE5 Fig. 3 Fig. 4 lease provide voltage and frequency when ordering. A special sealed pump must be used for horizontal flange-mounting of the unit in a position below the oil level. For gear pump unit model MFE5 complete with metal or plastic reservoir (3, 6 and 15 liters) see the pages 7 9. 4 1-1202-EN

Explanation of hydraulic function Both (ME5, MFE5) types have the same hydraulic function. Oil is sucked in at S and flows under pressure through the duct in the direction. The oil pressure closes valve V and opens valve E3, at the same time closing valve E1 against spring tension. If air is entrained (due to low oil level in the reservoir), valve V remains open and diverts the air or, respectively, the air-oil mixture into the return duct (see bubble (o) marking in direction R1). Valve C allows oil under overpressure to flow out into the return duct (see cross (+) marking). Fig. 5 ø96 149 When the unit stops (interval time), spring-loaded valve E1 opens and valve E3 simultaneously closes. The system pressure at can now be released through valve E1 with the exception of a small amount of residual pressure determined by valve E2. This pressure release is required for the piston distributors to function correctly. The pressure relief process is shown in fig. 4. Explanation of the structural differences In the case of model ME5, the long screw plug D1 blocks flanged port R2 of the return duct. The oil returning from valves V, C and E1 flows via port R1 through a tube to the separately mounted oil reservoir (see fig. 1 and 2). 18 M5 (4 ) 8.1 ø5.8 R2 ø50 d9 ø49 1) M14 1.5 O-ring 48 3 13.5 0 44.5 In the case of model MFE5, the short screw plug D2 unlike D1 with model ME5 leaves flanged port R2 open. A plug closes off external port R1. Flanged port R2 of the return duct drains directly into the reservoir without any connection threads (see fig. 3 and 4). MFE5 unit variants * ø100 S 1) M14 1.5 87 63 63 connection for cable 4 11 mm diam. Flow Max. back rate 2 ) pressure 3 ) Order No. [l/min] [bars] Design MFE5-2000 0.5 28 Basic version, NBR, plastic terminal box MFE5-3041 0.5 28 Basic version, NBR, metal terminal box MFE5-2000-D 0.5 28 Installed below oil level, NBR, plastic terminal box MFE5-3000-D 0.5 28 Installed below oil level, NBR, metal terminal box MFE5-2008 0.5 28 Basic version, FKM (FM), plastic terminal box MFE5-2009 0.25 17.5 For light oil as of 5 mm 2 /s, NBR MFE5-2053 0.25 17.5 For light oil as of 5 mm 2 /s, FKM MFE5-4000 0.5 28 UL/CSA-approved, NBR MFE5-5000 0.5 28 CCC-approved, NBR MFE5-1001 0.5 28 HAN6ES Harting connector, NBR, Motor 180 turned MFE5-1088 0.5 28 HAN10ES Harting connector, FKM MFE5-S67 0.5 28 50/95 weatherproofing, NBR, metal terminal box *) The geometrical dimensions of the variants can deviate of the one shown in Fig. 5. 2 ) Flow rate based on an operating viscosity of 140 mm 2 /s, at a back pressure of p = 5 bars. 3 ) The max. back pressure is equivalent to the actual value of the built-in pressure limiting valve. If the units are operated with a single-phase AC supply, only 60% of the indicated pressure is permissible, i.e. a 16-bar pressure limiting valve should be fitted to the system. The appropriate capacitors for a frequency of 50 and 60 Hz are: 230 V... 8 μf: order No. 179-340-007 115 V... 30 μf: order No. 179-340-060 88 R1 S = inlet (suction port) = outlet (pressure port) R1 (ME5) = oil return from relief and pressure limiting valve R2 (MFE5) 1 ) orts tapped for solderless 8 mm diam tube connection. Technical data of the shown motor Motor................ Three-phase motor Mode of operation.......... S1, 100% Insulation class............ F Rated frequency [Hz]......... 50 60 Voltage [V] Y 4 )............ 400 480 Rated current [A]........... 0.29 0.29 Rated power [kw].......... 0.075 0.09 Rated speed [rpm].......... 2700 3200 Rated flow rate [l/min]........ 0.5 0,.6 Operating pressure [bars]....... 28 Operating temperature [ C]..... +10 to +40 Medium............... 20 to 1000 mm 2 /s Type of enclosure acc. to DIN 50050. I 54 Max. suction head [mm]....... 500 4 ) See page 6: Multivoltage motors 1-1202-EN 5

Multi-voltage motors for pump units (assembly M..) Many export oriented companies have to deal with voltages/frequencies that deviate from those in Germany. To make it easier for them to buy the most common pump units for centralized lubrication systems, we have developed 3 multirange motors that cover a wide range of three-phase voltages and frequencies. ump units with or without oil reservoirs are included, provided the hydraulic power data listed in the brochures are not exceeded (limit values). These pump units are designated as: M2, MF2, MFE2, M5, MF5, MFE5, FLM12-3, FLMF12-3, M202 Limit values for 0.2 l-units (M..2-Group): 27 bars 2000 mm 2 /s eff. 0.5 l-units (M..5-Group): 27 bars 1000 mm 2 /s eff. 1.2 l-units FLM12-3: 6 bars 850 mm 2 /s eff. 2 0.2 l-units M202: 12 bars 850 mm 2 /s eff. Our experience shows these units can meet almost every need. That means simplified warehousing for our customers and shorter delivery times, since we always have these 3 types of motors in stock. Range I 130-130 V / 173-225 V, 50 Hz 120-156 V / 208-270 V, 60 Hz order code: 199 order code ISO-F: 19E Range II 207-254 V / 360-440 V, 50 Hz 249-305 V / 432-528 V, 60 Hz order code: 299 order code ISO-F: 29E Range III 230-290 V / 398-500 V, 50 Hz 290-346 V / 500-600 V, 60 Hz order code: 399 order code ISO-F: 39E A tailor-made motor has to be used instead of a multirange motor in the following cases: when the desired operating voltage cannot be covered by one of the three voltage ranges, when the operating voltage, with the voltage tolerances to be expected, exceeds a defined voltage benchmark for the range, in the case of motors with TC thermistor sensors, for dual-circuit pump unit, e.g. M205 in the case of motors with UL/CSA version for units with a 4-pole motor Voltage 230/400 V, 50 Hz 140 230/400 V, 60 Hz 640 240/415 V, 50 Hz 150 240/415 V, 60 Hz 650 255/440 V, 50 Hz 165 255/440 V, 60 Hz 665 265/460 V, 50 Hz 175 265/460 V, 60 Hz 675 265/460 V, 60 Hz, UL 563 265/460 V, 60 Hz, CSA 676 280/480 V, 60 Hz 680 280/480 V, 60 Hz, UL 562 280/480 V, 60 Hz, CSA 681 280/480 V, 60 Hz, UL/CSA 564 Order code 6 1-1202-EN

MFE5 gear pump unit with 3 or 6 liter metal reservoir MFE5-BW3-2 1 ) ort tapped for solderless tube connection, for 8 mm diam. tube 2 ) Connection for cable 7 to 9 mm diam. 3 ) Connection for cable 4 to 11 mm diam. 149 Flow Reservoir Reservoir Order No. rate capacity material without Order No. [l/min] [l] float switch MFE5-BW3-2 0.5 3 die-cast aluminum MFE5-B3-2 MFE5-BW7 0.5 6 sheet steel MFE5-B7 WS 1) M14 1.5 13.4 0 19 110 Technical data Float switch (WS) for monitoring of minimum oil level Type of contact...... 1 changeover Max. switching voltage.. 230 V AC / 230 V DC Max. switching current.. 1.0 A Max. switching capacity.. 60 VA / 40 W 4 ) Type of enclosure..... I 65 Temperature range.... 10 C to +60 C 26 19 6 9 ø7 Return G 1/2 with screw plug 220 2) 3) 256 170 4 ) Take appropriate measures to protect contacts when switching inductive loads. 4 counterbores for fixing bolts DIN 912-M6 128 See page 5 for further technical details. MFE5-BW7 1 ) ort tapped for solderless tube connection, for 8 mm diam. tube Circuit diagram WS Hydraulic layout for MFE5-BW3-2 max. 230 V AC > minimum = minimum E 1 2 3 DIN EN 175301-803-A T1 WS M14 1.5 1) 370 1 2 3 M S R 140 43 ø9 (4 ) 222 300 Function float switch (WS) When the oil drops to a minimum level, contact 1 2 opens and contact 1 3 closes. 142 167 With plug-type connector that compiles with DIN EN 175301-803-A Depicted: full reservoir 1-1202-EN 7

MFE5 gear pump unit with 3 or 6 liter plastic reservoir MFE5-KW3-2 1 ) ort tapped for solderless tube connection, for 8 mm diam. tube 2 ) Connection for cable 7 to 9 mm diam. 149 Flow Reservoir Reservoir Order No. rate capacity material without Order No. [l/min] [l] float switch WS MFE5-KW3-2 0.5 3 plastic MFE5-K3-2 MFE5-KW6 0.5 6 plastic MFE5-K6 7 7 max. 1) M14 1.5 13.4 0 12.5 30 See page 5 for further technical details. min. See page 7 for technical data on the float switch. Hydraulic layout for MFE5-KW3-2 220 230 245 2) 3) 154 T1 130 269 M R S MFE5-KW6 1 ) ort tapped for solderless tube connection, for 8 mm diam. tube 2 ) Connection for cable 7 to 9 mm diam. 149 95 20 ø8.5 (3 ) max. WS M14 1.5 45 13.4 0 1) min. 183 35 110 312 290 110 0 3) 2) 108 178 8 1-1202-EN

MFE5 gear pump unit with 15 liter sheet steel reservoir MFE5-BW16 1 ) ort tapped for solderless tube connection, M14 1.5 for 8 mm diam. tube. 2 ) Connection for cable 7 to 9 mm diam. Flow Reservoir Reservoir rate capacity material Order No. [l/min] [l] Version MFE5-BW16 MFE5-BW15 0.5 15 sheet steel foot-mounted reservoir wall-mounted reservoir WS 2) 1) See page 5 for technical data. max. 453 Technical data Float switch (WS) to monitor the critical level of oil with advance warning about 25 mm before the minimum oil level is reached. min. 304 Type of contact...... 2 change-over contacts (reed contacts) Max. switching voltage.. 230 V AC / 230 V DC Max. switching current.. 0.8 A Max. switching capacityn. 60 VA / 40 W 3 ) Type of enclosure..... I 65 Temperature range.... 10 C to +60 C 3 ) Take appropriate measures to protect contacts when switching inductive loads. ø9 (4 ) Return G 1/2 with screw plug (2 ) 400 124 426 436 200 Circuit diagram WS Function float switch (WS) max. 230 V AC > minimum pre-warning E DIN EN 175301-803-A 1 2 3 1 2 3 About 25 mm before the minimum oil level is reached contact 1 3 closes. When the minimum oil level is reached contact 1 2 opens in addition. With plug-type connector to DIN EN 175301-803-A Depicted: full reservoir Hydraulic layout for MFE5-BW16 Bracket for wall mounting T1 Order No. 249-032.10 ø9 180 ±0.5 405 ±0.5 M S R R 1-1202-EN 9

Notes 10 1-1202-EN

Order No. 1-1202-EN Subject to change without notice! (07/2014) Important product usage information All products from SKF may be used only for their intended purpose as described in this brochure and in any instructions. If operating instructions are supplied with the products, they must be read and followed. Not all lubricants are suitable for use in centralized lubrication systems. SKF does offer an inspection service to test customer supplied lubricant to determine if it can be used in a centralized system. SKF lubrication systems or their components are not approved for use with gases, liquefied gases, pressurized gases in solution and fluids with a vapor pressure exceeding normal atmospheric pressure (1013 mbars) by more than 0.5 bar at their maximum permissible temperature. Hazardous materials of any kind, especially the materials classified as hazardous by European Community Directive EC 67/548/EEC, Article 2, ar. 2, may only be used to fill SKF centralized lubrication systems and components and delivered and/or distributed with the same after consulting with and receiving written approval from SKF. Further brochures 1-9201-EN Transport of Lubricants in Centralized Lubrication Systems SKF Lubrication Systems Germany GmbH Motzener Strasse 35/37 12277 Berlin Germany F 970444 12704 Berlin Germany Tel. +49 (0)30 72002-0 Fax +49 (0)30 72002-111 www.skf.com/lubrication This brochure was presented by: SKF is a registered trademark of the SKF Group. SKF Group 2014 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.