Welcome to the World of Aavid Heat Pipes



Similar documents
Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

Everline Module Application Note: Round LED Module Thermal Management

Heat Pipe Selection Revision 12/04/2001

The Effect of Forced Air Cooling on Heat Sink Thermal Ratings

CCI HEAT PIPE DESIGN GUIDE

Peltier Application Note

Heat Pipe Cooling of Concentrating Photovoltaic (CPV) Systems

Il Peso del Thermal Management nei LED

Mounting Instructions for SP4 Power Modules

Guidelines for Earthquake Bracing Residential Water Heaters

BB-18 Black Body High Vacuum System Technical Description

Guidelines for Earthquake Bracing of Residential Water Heaters

CPU COOLING OF DESKTOP COMPUTER BY PARALLEL MINIATURE HEAT PIPES

Effective Cooling Method for Spin Casting Process

W I T H I N J O I ST S I N STA L L AT I ON

Thermoelectric Generator (TEG) for Heavy Diesel Trucks John C. Bass, Aleksandr S. Kushch, Norbert B. Elsner Hi-Z Technology, Inc.

The Three Heat Transfer Modes in Reflow Soldering

Puddle Flange. FRANK Puddle Flange

Comparing naturally cooled horizontal baseplate heat sinks with vertical baseplate heat sinks

Surface Mount Technology cooling for high volumes applications by: Cesare Capriz Aavid Thermalloy via XXV Aprile 32 Cadriano (BO) ITALY

Heat Pipe, selection of working fluid

Plastic Injection Molding

TopSky DLG Installation Manual

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

Thermal Storage Unit Using the Triple Point of Hydrogen

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Calculating Heat Loss by Mark Crombie, Chromalox

LED HEATSINKS Spotlight / Tracklight HighBay / LowBay Reflector ring & Housing Customized Heatsinks

Single Cavity Mould. Basic Mould Construction. Ejection System. Multi Cavity Mould

1. At which temperature would a source radiate the least amount of electromagnetic energy? 1) 273 K 3) 32 K 2) 212 K 4) 5 K

Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems

Facts About. Industrial gases for better injection molding. This article appeared in the trade journal Kunststoffe plast europe, issue 12/2004.

FREEBIRD THE ORIGINAL D.I.Y. ORNITHOPTER! Tools and Glue. Required Materials

Introduction to vacuum gauges. Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges)

CONDENSATION IN REFRIDGERATED BUILDINGS

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Lecture 23: Terrestrial Worlds in Comparison. This lecture compares and contrasts the properties and evolution of the 5 main terrestrial bodies.

ADVANCED COOLING TECHNOLOGIES, INC. Innovations in Action

STANDARD EXTRUDED HEAT SINKS

Heat Transport Study of the Laminar Heat Pipe Heat Exchanger

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series.

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

EVALUATION OF UNDERGROUND RAILWAY NETWORKS OPERATING SUSTAINABLE COOLING SYSTEMS. J.A. Thompson*, G.G. Maidment, J.F. Missenden and F.

Thermal Simulation of a Power Electronics Cold Plate with a Parametric Design Study

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Balancing the Electrical and Mechanical Requirements of Flexible Circuits. Mark Finstad, Applications Engineering Manager, Minco

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

How To Understand Evaporator

Selecting TEMA Type Heat Exchangers

Machine Nozzles Injection Nozzle

Surface Tension. the surface tension of a liquid is the energy required to increase the surface area a given amount

Soil Suction. Total Suction

EXTRUDED HEAT SINKS FOR POWER SEMICONDUCTORS

DIESEL EFFECT PROBLEM SOLVING DURING INJECTION MOULDING

Modular Locomotive System Instruction Manual for HBK8 George Body Kit

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

For New Technology Network. Steel Manufacturing Machinery Product Guide Book

FOR ANY QUESTIONS, PLEASE CALL M-F 8:00a.m.-8:00p.m. EST. REAR BRAKES 1 AEROSPACE COMPONENTS

FREESTUDY HEAT TRANSFER TUTORIAL 3 ADVANCED STUDIES

Solid shape molding is not desired in injection molding due to following reasons.

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

1-Stainless Steel conical fermenter with a thermometer setup.

Integration of a fin experiment into the undergraduate heat transfer laboratory

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction

Using Portable Spot Air Conditioners in Industrial Applications

ADVANCED DIGITAL SOLUTIONS SERVICE NUMBER

Zero Emission Engine. An Economic and Environmental Benefit

16. Heat Pipes in Electronics Cooling (2)

I BEAM TRACK INSTALLATION

Effects of the MuCell Molding Process

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE

Chapter 5 - Aircraft Welding

TECHNICAL SPECIFICATION

Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems

TEACHER BACKGROUND INFORMATION THERMAL ENERGY

FUNDAMENTALS OF ENGINEERING THERMODYNAMICS

SP-06 SinkPAD-II Rebel 25mm Round LED Assembly

SOLDERING TERMINALS TRAINING CERTIFICATION TEST (DVD-18C)

STEERING HANDLEBAR/FRONT WHEEL/ FRONT SHOCK ABSORBER

Natural Convection. Buoyancy force

Thermal Management of Electronic Devices used in Automotive Safety A DoE approach

NetShape - MIM. Metal Injection Molding Design Guide. NetShape Technologies - MIM Phone: Solon Road FAX:

Low-cost Solar Desalinator

Corrugated Tubular Heat Exchangers

Tube Control Measurement, Sorting Modular System for Glass Tube

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Liquid Hydrogen Storage - Takuji Hanada, Kunihiro Takahashi

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector

Floor Heating Warehouse.co.uk

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time

2014 British Columbia Building Code Changes

Activity: Clouds, Air Pressure and Temperature

Milling Chuck Features

Pipe Clamps and Accessories

جامعة البلقاء التطبيقية

Chapter 2, Lesson 5: Changing State Melting

TechCut 4 Precision Low Speed Saw

2. Room temperature: C. Kelvin. 2. Room temperature:

Transcription:

Welcome to the World of Aavid Heat Pipes As a pioneer in heat pipe technology and their application, Aavid Thermalloy has developed a high quality manufacturing process to ensure long life and reliability in our heat pipes. We ve had over a decade of experience designing and fabricating heat pipes and heat pipe assemblies. Heat Pipes are great thermal energy transporters that use an evaporator and condenser in place of a solid conductor. While they don t dissipate heat themselves, heat pipes quickly move heat from one area of the heat pipe to another area. The aerospace industry has been the proving ground of heat pipe reliability, and has been used for decades in harsh and demanding environments. Applications Heat pipes are great at moving or spreading heat, especially when embedded in a base plate. They can quickly move heat away from temperature sensitive devices to a place the heat can be dissipated. Heat pipes can also be used to increase fin efficiency by moving heat directly to the cooler top portion of fins. Many types of applications can benefit from heat pipes. Aerospace applications Consumer Electronics (Desktops, notebooks) Servers Telecommunication Motor Drives and Controllers UPS Transportation Efficient Heat Transport Air Cooling Improves conduction paths of heat away from devices Extends thermal range of both natural and forced convection cooling Aavid HiContact heat pipe embedding process improves thermal transfer Reduces overall cost and weight without increasing the volume in a base plate Best passive cooling system with no moving parts Small diameter heat pipe assemblies provide greater thermal efficiency Large diameter heat pipe assemblies transfer greater power loads Large Diameter Assemblies Small Diameter Assemblies Hi-Contact

How do Heat Pipes Work? A heat pipe is a closed evaporator-condenser system consisting of a sealed, hollow tube whose inside walls are lined with a capillary structure or wick. Thermodynamic working fluid, with substantial vapor pressure at the desired operating temperature, saturates the pores of the wick in a state of equilibrium between liquid and vapor. When heat is applied to the heat pipe, the liquid in the wick heats and evaporates. As the evaporating fluid fills the heat pipe hollow center, it diffuses throughout its length. Condensation of the vapor occurs wherever the temperature is slightly below that of the evaporation area. As it condenses, the vapor gives up the heat it acquired during evaporation. This effective high thermal conductance helps maintain near constant temperatures along the entire length of the pipe. Attaching a heat sink to a portion of the heat pipe makes condensation take place at this point of heat transfer and establishes a vapor flow pattern. Capillary action within the wick returns the condensate to the evaporator (heat source) and completes the operating cycle. Heat Pipe Cycle Evaporation Vapor Flow Impermeable Wall Porous Wick Cavity for Vapor Flow Condensation Heat Addition Heat Rejection Evaporator Adiabatic Section Condenser Liquid return through the wick The internal liquid absorbs thermal energy conducted through the wall of the pipe and evaporates. The pressure forces this vapor away from the heated portion of the heat pipe to the cooler region(s). Thermal energy is absorbed by the cooler heat pipe region away from the heat source, where the vapor condenses back into liquid. Capillary action from the wicking structure transports the liquid back to the area where evaporation occurs, starting the cycle again.

Heat Pipe Exploration and Discovery Kits Aavid s Heat Pipe Exploration and Discovery Kits are designed for you to get your hands onto our heat pipes to get a feel for how they work, what they do, and try them in your own application. Assemble, bend, and rough together a prototype for your latest application then contact us for help with your design. We can fabricate prototypes with tighter bends in our quick turn shop or go to production in our worldwide manufacturing facilities. Heat Pipe Exploration Kit - Part #: 056325 Kit Contents Qty. Item (mm) Diameter (mm) 30 228.6 Heat Pipes 4, 6, 8 30 304.8 Heat Pipes 4, 6, 8 30 152.4 Heat Pipes 4, 6, 8 15 40 x 40 Evaporator Plates 4, 6, 8 15 40 x 40 Evaporator Caps 15 40 x 150 Condenser Plates 4, 6, 8 15 40 x 150 Condenser Caps 200 M3 Screws 1oz. Tube of Thermal Grease What can you do with your kit? Heat Pipe Discovery Kit - Part #: 057455 Kit Contents Qty. Item (mm) Diameter (mm) 10 228.6 Heat Pipes 4, 6 10 304.8 Heat Pipes 4, 6 10 152.4 Heat Pipes 4, 6 4 40 x 40 Evaporator Plates 4, 6 4 40 x 40 Evaporator Caps 4 40 x 150 Condenser Plates 4, 6 4 40 x 150 Condenser Caps 100 M3 Screws 1 oz. Tube of Thermal Grease Order Your Kits Online at www.aavid.com Pipe Selection - Diameter and Length The vapor pressure differential between the condenser end and the evaporator end controls the rate at which the vapor travels from one end to the other. Diameter and length of the heat pipe also affect the speed at which the vapor moves and must be considered when designing with heat pipes. The larger the diameter, the more cross sectional area available to allow vapor to move from the evaporator to the condenser. This allows for greater power carrying capacity. Conversely, length when in opposition to gravity has a negative effect on heat transport as the rate at which the working fluid returns from the condenser end to the evaporator end is controlled by the capillary limit of the wick which is an inverse function of the length of the pipe. Therefore, shorter heat pipes carry more power than longer pipes when used in application not assisted by gravity. Aavid has included a selection of standard heat pipe diameters in a few lengths. The power carried by the heat pipe depends upon diameter and length of the heat pipe. Expected Power Ranges 4mm: 5-15 W 6mm: 25-45 W 8mm: 35-60 W Aavid can customize heat pipes into a variety of diameters, lengths, and internal structures to cover the whole range of heat pipe applications dissipating as low as a few watts and up into the kilowatt range. We can design and fabricate the right heat pipe for your application. We ve had plenty of experience optimizing each heat pipe in many different conditions.

Pipe Forming or Shaping Heat pipes are easily bent or flattened to accommodate the needs of the heat sink design. Forming heat pipes may affect the power handling capability as the bends and flattening will cause a change in fluid movement inside the pipe. Therefore design rules that take into consideration heat pipe configurations and the effect on thermal performance ensure the desired performance. Bending Bending heat pipes by hand can be tricky since it s easy to collapse the pipe. The diameter is what will define the centerline bend radius. Soft tooling or generic pipe benders can tighten that radius. By Hand: 4mm: 4 x dia. 6mm: 4 x dia. 8mm: 5 x dia. Generic or Soft Tooling: 4mm: 3 x dia. 6mm: 3 x dia. 8mm: 4 x dia. Pipe Flattening More contact area your heat pipe has you re your device, the less distance and resistance heat needs to overcome to enter the heat pipe. Using simple tooling (like a smooth faced vice), it is possible to flatten heat pipes to lower the profile and increase contact area of the heat pipe surface. Before the flat surface bends inwards, you can generally get to a heat pipe thickness of: 4mm: 2.3mm 6mm: 3.0mm 8mm: 5.0mm Need Tighter Bends or Flatter Pipes? For our standard sintered wick heat pipes, we can flatten heat pipes as thin as: 4mm: 2.0 mm 6mm: 2.0 mm 8mm: 2.5 mm If you require even thinner heat pipe profiles, Aavid can meet your needs. We can fabricate Ultra Thin heat pipes with our specialized internal structure that will not sacrifice performance at low profiles. 4mm-8mm: <1mm With our specialized tooling we can achieve centerline bend radius as tight as 1.5x the pipe diameter without collapsing the bend. We re experts in bending complex shapes with heat pipes to avoid any keep out zones or other hardware you may have in your system. Aavid can flatten heat pipes for any low profile applications. Our technique prevents concave surfaces from forming to produce the optimal heat pipe surface for mounting your device.

Heat Pipe Assemblies The Heat Pipe Exploration Kit includes basic interfacing hardware between heat pipes, devices, and cooling solutions of your choosing. Each aluminum evaporator and condenser has a tight channel and matching screw on caps to clamp down onto these heat pipes and minimize thermal resistance from the gap between the pipe surface and channel groove. Matching the heat pipe diameter to the correct sized evaporator and condenser will provide the best thermal connection. Depending upon length, your interface resistance ((m2k)/w ) between the heat pipe and the aluminum plates will be between: 4mm: 5-15 W, 6mm: 25-45 W, 8mm: 35-60 W. Heat Pipe Assembly Example Using Kit Materials 1 2 3 4 5 A B C Heat generated by the device will evaporate liquid in the section attached to it. Vapor, driven by the internal pressure differential, will travel to the condenser end of the heat pipe. Heat from the vapor will escape the system through the condenser plate and attached cooling means. Vapor condenses back into liquid and seeps into the internal wicking structure of the heat pipe. Liquid travels back to the evaporator end of the heat pipe by capillary action. Attach an Evaporator Plate to collect thermal energy from your heat source. Modify the Evaporator Plate to make mounting to your component easier. Use Thermal Grease in between surfaces to improve heat transfer. D E F B A D 1 E Apply thermal grease and insert heat pipe into Evaporator and Condenser Plate. Screw on caps to plates to secure and apply light pressure to heat pipe to reduce thermal resistance from the thermal grease. C Bend the heat pipe to fit in tight spaces or avoid obstacles. Bends should be no tighter than a radius of 3x the heat pipe diameter to keep the pipe from collapsing or pinching. 2 G H I F 3 5 G H Add a heat sink or attach to a cold wall to remove heat from the system. Modify Condenser Plate to mount heat sinks or other cooling methods. Cut Condenser Plate to length needed. I 4 Aavid s Assembly Capabilites Aavid s HiContact puts the heat pipe in direct contact with your device with geometry that tightly fits heat pipes within a plate. HiContact grooves have a much thinner interface layer that we fill with highly conductive thermal epoxy or solder. Depending on length, thermal interface resistance ((m2k)/w ) using epoxy in a HiContact groove will be between: 4mm: 0.005-0.02. 6mm: 0.003-0.01, 8mm: 0.003-0.009. For more design guidelines visit www.aavid.com +1-603-528-3400 +39 051 764011 +86-21-6115-2000 www.aavid.com

Aavid s World Class Design Assistance There is a wide variety of applications that would benefit from integrating heat pipes in their thermal solution, so most are developed specifically for the application. Most applications are unique in their requirements and the optimal solution varies from one to the next. Our Design Centers located across the globe have rapid design cycles and quick turn prototype capabilities to meet your project needs. Most large diameter heat pipes are custom fabricated and may employ different combinations of wick structures, liquid volumes, and construction methods in order to maximize performance. Aavid can design optimized heat pipes for you application and can manufacture high quality pipes for installation into your system. Aavid has shipped over 10 million high quality units worldwide in the past 10 years. Contact your local Design Center Start designing your heat pipe solution today Laconia New Hampshire Tel: +1-603-528-3400 Email: NEDC@aavid.com San Jose, California Tel: +1-408-522-8730 Email: CADC@aavid.com Shanghai, China Tel: +86-21-6115-2000 Email: SHDC@aavid.com Taiwan, China Tel: +886-7-841-9339 Email: KSDC@aavid.com Austin, Texas Tel: +1-512-382-8100 Email: TXCD@aavid.com Bologna, Italy Tel: +39-051-764011 Email: EUDC@aavid.com Shenzhen, China Tel: +86-21-6119-2000 Email: sales.china@aavid.com Vadodara, India Tel: +91-2667-264781 Email: sales.in@aavid.com