EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications



Similar documents
8146/5 Series Breaker Panelboards

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire with LED Series EXLUX 6402/2

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

High Bay Occupancy Sensor Selection Guide

Wolflite Safety Handlamp H-251E

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

Operating Instructions

ConSig 8040 Series CONTROLS Features:

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Floodlight Range Installation Guide

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Dialight LED Lighting Fixture Catalog. for Industrial and Hazardous Locations

Technical Information RIA14

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

LED...A Q Series Sealed High-Intensity

G H I J K G DIMMING. QS no dimming 1 0. (10%) 3-wire hot dim EcoSystem (10%) digital dim U 0 Mark 7 (1% HO 5% HE) 0-10 V M 0 Mark 10 (1%) hot dim N 0

Terminal Boxes Series 8146

Product and functional description

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W

PAINT BOOTH LIGHTING

2M IR Mini Dome Quick Installation Guide

7 Lighting Technology

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

Safety instructions VEGADIS DIS81.CEIA/V****

DuroSite LED High Bay - UL / CSA. for Indoor and Outdoor Industrial Applications

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Plug and Socket Devices CES 63 A Series 8579

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

DuroSite TM High Bay Lighting

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Series 8146/5-V37 and Series 8150/5-V37

12 Volt Lighting Products

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

GUE, GUB Junction Boxes

Solenoid Valve Island Type 3965

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

3500/93 System Display

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Electronic, Digital and Mechanical Vibration Switches

Dialight LED Lighting Fixture Catalog. for Indoor and Outdoor Industrial and Hazardous Locations

Operation Manual. Trans-Flo

DuroSite TM Series LED High Bay. for Industrial & Commercial Applications.

Scraper Passage Indicator. Electrical Indicator. Features

Series 510 Submersible Level Transmitters

HERZ-Thermal Actuators

A good connection. International approvals.

V A P O R P R O O F b y D e s i g n

Machine Safety Switch: SI-LM40 Series Limit Switch Style

MULTI-BEAM LS10 Light Screen System

FIREDEX Conventional Fire Panels

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Advantium 2 Plus Alarm

Liquid Level Limit Switch liquiphant T FTL 20

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

Plug and Socket Devices SolConeX 16 A Series 8570

Operating Instructions

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

AMERBRITE UNDERWATER WHITE LED POOL LAMP

INSTALLATION INSTRUCTIONS

4 Posiflow Proportional Solenoid Valves

Digital inductive conductivity transmitter

Screw Plug Immersion Heaters

Worcester DS/DM Series UltraSwitch Switch box

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

WHOLESALE DIRECT INC WEST 65TH STREET

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

General 1-2-Opto-electronics Safety Switches 4-Emergency

MXS 3. MANUAL FULLY CHARGED PULSE, MAINTENANCE CHARGING EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT CHARGE CABLE ERROR LAMP MODE- BUTTON

Product Specification instalert Rapid Messenger Variable Message Sign

Battery Power Inverters

Universal Voltage Terminal Photoelectric E3JM

Mureva Assembly surface mounted wiring devices

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

DuroSite LED Linear Fixture - UL / CSA for Indoor and Outdoor Industrial Applications

Contractors Guide Central Inverter System Installation

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Emergency lighting units EM powerled

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

Capacitive Prox E2K-X

LED Tubular Lamp / Kit Guide

Transcription:

EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin Lamps One or two-lamp versions: 8W 17W 32W 40W Enclosure Material: FRP Cover Material: Polycarbonate B

LIGHTING EXLUX 6000 Series EXPLOSION PROTECTED FLUORESCENT LIGHTING FIXTURES FOR HAZARDOUS AND CORROSIVE APPLICATIONS CLASSIFICATIONS NEC- Class I, Zone 1 & 2, AEx de IIC T4 Class I, Division 2, Groups A,B,C,D, T4 Class II, Divisions 1 & 2, Groups E,F,G NEMA 3, 4, 4X & IP66 File No. J.I.3D2A9.AE CEC- Class I, Zone 1 & 2, Ex de IIC T4 Class I, Division 2, Groups A,B,C,D, T4 Class II, Divisions 1 & 2, Groups E,F,G CSA ENCLOSURES TYPE 3,4 & 4X; IP66 Certified File No. LR99480 Ambient Temperature Range: +55 C (+131 F) Max. 20 C ( 4 F) Min. Supply Voltage 120 ±10% AC/DC 0-60Hz FEATURES The EXLUX 6000 Series of Lighting Fixtures are designed for hostile and hazardous locations where reliability and rugged performance are critical. The housing is constructed of heavyduty fiberglass reinforced polyester (FRP) with a single piece, low glare polycarbonate lens. The EXLUX 6000 Series is supplied with electronic ballasts as standard and is available in 17, 32 and 40-watt one or two-lamp versions. The appropriate lamps are standard T8 medium bipin lamps. The fixtures are available in either dead-end or feed-through wiring. The ballasts are encapsulated in a selfcontained flameproof enclosure with increased safety terminals for the highest degree of safety. The electronic ballast meets ANSI C82.11 standards regarding harmonic distortion. INSTALLATION The fixture includes threaded NPT openings with grounded backplates and NPT close-up plugs. For MC-HL cable installation use TMC cable glands. For conduit installation use conduit hubs 8166/11-0 -N. Fluorescent Lighting Fixtures for Div. 2, Zone 1 and Zone 2 Applications Fixtures for Use with Standard T8 Med. Bipin Lamps Ordering Information Catalog Number 17 Watt, 2' 6000/531-8091-8130-120-60 1-lamp fixture 120/125V AC/DC 0-60Hz, dead-end wiring, Entries: * 6000/531-8591-8150-120-60 1-lamp fixture 120/125V AC/DC 0-60Hz, 5 wire feed-thru, Entries: * 6000/532-8091-8130-120-60 2-lamp fixture 120/125V AC/DC 0-60Hz, dead-end wiring, Entries: * 6000/532-8591-8150-120-60 2-lamp fixture 120/125V AC/DC 0-60Hz, 5 wire feed-thru, Entries: * 32 Watt, 4' 6000/551-8091-8130-120-60 1-lamp fixture 120/125V AC/DC 0-60Hz, dead-end wiring, Entries: * 6000/551-8591-8150-120-60 1-lamp fixture 120/125V AC/DC 0-60Hz, 5 wire feed-thru, Entries: * 6000/552-8091-8130-120-60 2-lamp fixture 120/125V AC/DC 0-60Hz, dead-end wiring, Entries: * 6000/552-8591-8150-120-60 2-lamp fixture 120/125V AC/DC 0-60Hz, 5 wire feed-thru, Entries: * 40 Watt, 5' Description 6000/571-8091-8130-120-60 1-lamp fixture 120/125V AC/DC 0-60Hz, dead-end wiring, Entries: * 6000/571-8591-8150-120-60 1-lamp fixture 120/125V AC/DC 0-60Hz,5 wire feed-thru, Entries: * 6000/572-8091-8130-120-60 2-lamp fixture 120/125V AC/DC 0-60Hz,dead-end wiring, Entries: * 6000/572-8591-8150-120-60 2-lamp fixture 120/125V AC/DC 0-60Hz, 5 wire feed-thru, Entries: * * Possible entries either end: 1 x 1/2", or 2 x 1/2", or 1 x 3/4" NPT. Please specify. For parts and accessories see pages B6-B8. B1

EXLUX 6008 Series LIGHTING EXPLOSION PROTECTED FLUORESCENT EMERGENCY LIGHTING FIXTURES WITH AUTO-TESTING EMERGENCY BALLAST. CLASSIFICATIONS NEC- Class I, Zone 1 & 2, AEx dem IIC T4 Class I, Division 2, Groups A,B,C,D, T4 Class II, Divisions 1 & 2, Groups E,F,G NEMA 3, 4, 4X & IP66 File No. J.I.3D2A9.AE CEC- Class I, Zone 1 & 2, Ex dem IIC T4 Class I, Division 2, Groups A,B,C,D, T4 Class II, Divisions 1 & 2, Groups E,F,G Emergency Fluorescent Lighting Fixtures - With Battery Back-up Units for Div. 2, Zone 1 & Zone 2 Applications Fixtures for use with Standard T8 Med. Bipin Lamps Ordering Information Catalog Number 32 Watt, 4' Description 6008/552-9097-8140-120-60 Auto Testing, 2-lamp fixture 120V 60Hz, dead-end wiring, Entries: * 6008/552-9697-8160-120-60 Auto Testing, 2-lamp fixture 120V 60Hz, 6 wire feed-thru, Entries: * * Possible entries either end: 1 x 1/2", or 2 x 1/2", or 1 x 3/4" NPT. Please specify. For parts and accessories see pages B6-B8. Status Indicator Display LED Display Green LED permanently ON Green LED 1 :1 blinking Green LED 1:10 flashing Red LED permanently ON Red LED 1:1 blinking Red LED 1 :10 flashing Display Description Everything OK Quarterly, Automatic Emergency Lighting Time Duration Test Weekly, Automatic Function Test Emergency Lighting Time Operation Test. Battery holds 2/3 of the battery charge needed for the set Emergency light duration. Conclusion: Battery replacement needed Battery Empty not in working condition Battery Defective (presumed cell polarity reversed) CSA ENCLOSURES TYPE 3,4 & 4X; IP66 Certified File No. LR99480 Supply Voltage 120V, 50-60Hz Ambient Temperature Range: AC & Battery Operation +50 C (+122 F) Max. 20 C ( 4 F) Min. Charging & Test Operation +50 C (+122 F) Max. 5 C (+23 F) Min. FEATURES The EXLUX 6008 Series carries out pre-programmed testing schedules, monitors emergency ballast performance and battery charging. In case of power failure the Auto-testing Emergency Ballast automatically switches to emergency mode, keeping one lamp illuminated at reduced lumen output for a minimum of 90 minutes. When AC power is restored, the fixture returns to AC supply. It also can be set for 3 hours emergency operation with reduced light output. The EXLUX 6008 Series of Emergency Lighting Fixtures are designed for hostile and hazardous locations where reliability and rugged performance are critical. The housing is constructed of fiberglass reinforced polyester (FRP) with a single piece, low glare polycarbonate lens. It is supplied with flameproof electronic ballasts as standard and is available in 1x 32 Watts and 2x 32 Watts versions. INSTALLATION The fixture includes threaded NPT openings with grounded backplates and NPT close-up plugs. For MC-HL cable installation use TMC cable glands. For conduit installation use conduit hubs 8166/11-0 -N (see page B7). The fixture must be wired with a permanent charging phase which needs to be the same potential as the switched phase. The terminal capacity is 2 stranded wires 10 AWG per terminal. PERIODIC AUTO TESTING The fixture automatically performs a weekly functional test. The discharge test is factory set for manual testing. If automatic testing is preferred the jumper wire needs to be removed as explained in the IOM sheet. STATUS INDICATOR DISPLAY One red LED and one green LED are incorporated into the fixture and can be seen from the outside through the lens. The functions and test results are listed on this page. B2

LIGHTING EXLUX 6400 Series EXPLOSION PROTECTED FLUORESCENT LIGHTING FIXTURES FOR HAZARDOUS AND CORROSIVE APPLICATIONS CLASSIFICATIONS NEC- Class I, Zone 2, Group IIC T4 Class I, Division 2, Groups A,B,C,D, T4 Class II, Divisions 1 & 2, Groups E,F,G, T5 NEMA 3, 4, 4X & IP66 File No. J.I.3009378 CEC- Class I, Zone 2, Group IIC T4 Class I, Division 2, Groups A,B,C,D, T4 Class II, Divisions 1 & 2, Groups E,F,G, T5 CSA ENCLOSURES TYPE 3,4 & 4X; IP66 Certified File No. LR99480 Ambient Temperature: For Class I areas: +55 C (+131 F) Max.; -18 C (0 F) Min. For Class II & III areas: +40 C (+104 F) Max.; -18 C (0 F) Min. Supply Voltages (see ordering information) FEATURES The EXLUX 6400 Series of Lighting Fixtures are designed for hostile and hazardous locations where reliability and rugged performance are critical. The housing is constructed of heavy-duty fiberglass reinforced polyester (FRP) with a single piece, low glare polycarbonate lens. The EXLUX 6400 Series is supplied with electronic instant-start ballasts as standard and is available in 17, 32 and 40-watt one or two-lamp versions. The two-lamp versions are dual channel, which keeps the fixture functional should one lamp fail. The power factor is.99. The electronic ballast meets ANSI C82.11 standards regarding harmonic distortion. INSTALLATION The fixture includes threaded NPT openings with grounded backplates and NPT close-up plugs. For MC Cable installation use TMC cable glands. For conduit installation use conduit hub 8166/11-0 -N. The appropriate lamps are standard T8 medium bipin lamps. Fluorescent Lighting Fixtures for Div. 2 and Zone 2 Applications Fixtures for Use with Standard T8 Med. Bipin Lamps Ordering Information Catalog Number 17 Watt, 2' 6400/531-8090-9000-120-277-50/60 1-lamp fixture 120-277V 50/60Hz, Entries: * 6400/531-8090-9000-347-50/60 1-lamp fixture 347V 50/60Hz, Entries: * 6400/532-9090-9000-120-277-50/60 2-lamp fixture 120-277V 50/60Hz, Entries: * 6400/532-9090-9000-347-50/60 2-lamp fixture 347V 50/60Hz, Entries: * 32 Watt, 4' 6400/551-8090-9000-120-277-50/60 1-lamp fixture 120-277V 50/60Hz, Entries: * 6400/551-8090-9000-347-50/60 1-lamp fixture 347V 50/60Hz, Entries: * 6400/552-9090-9000-120-277-50/60 2-lamp fixture 120-277V 50/60Hz, Entries: * 6400/552-9090-9000-347-50/60 2-lamp fixture 347V 50/60Hz, Entries: * 40 Watt, 5' Description 6400/571-8090-9000-120-277-50/60 1-lamp fixture 120-277V 50/60Hz, Entries: * 6400/572-9090-9000-120-277-50/60 2-lamp fixture 120-277V 50/60Hz, Entries: * For optional cover interlock switch change these 0 s to 1 s. * Possible entries either end: 1 x 1/2", or 2 x 1/2", or 1 x 3/4" NPT. Please specify. For parts and accessories see pages B6-B8. B3

EXLUX 6408 Series LIGHTING EXPLOSION PROTECTED FLUORESCENT EMERGENCY LIGHTING FIXTURES FOR HAZARDOUS AND CORROSIVE APPLICATIONS CLASSIFICATIONS NEC- Class I, Zone 2, Group IIC T4 CEC- Class I, Division 2, Groups A,B,C,D, T4 Class II, Divisions 1 & 2, Groups E,F,G, T5 NEMA 3, 4, 4X & IP66 File No. J.I.3009378 CSA ENCLOSURES TYPE 3,4 & 4X; IP66 Certified File No. LR99480 Ambient Temperature Range: For class I areas: +50 C (+122 F) Max. -18 C (+0 F) Min. For class II and III areas: +40 C (+104 F) Max. -18 C (+0 F) Min. Supply Voltage Range from 120V, to 277V, 60 Hz Emergency Fluorescent Lighting Fixtures with Battery Back-up Unit for Div. 2 and Zone 2 Applications Fixtures for use with Standard T8 Med. Bipin Lamps Ordering Information Catalog Number 32 Watt, 4' Description 6408/552-9098-9000-120-277-50/60 2-lamp fixture 120-277V 50/60Hz, Entries: * * Possible entries either end: 1 x 1/2", or 2 x 1/2", or 1 x 3/4" NPT. Please specify. For parts and accessories see pages B6-B8. FEATURES The EXLUX 6408 Series of Emergency Lighting fixture is equipped with one battery back-up unit which in case of power failure automatically switches over to battery supply keeping one lamp illuminated at reduced lumen output for a minimum of 90 minutes. When AC power is restored, the fixture returns to AC supply. When the Red LED indicating light is illuminated the battery is being charged or monitored. It is visible from the outside through the lens. The EXLUX 6408 Series is also supplied with an AC electronic instant start ballast unit and is available in 2 x 17W or 2 x 32W parallel lamps. This keeps the fixture functional should one lamp fail. The power factor is.99. The electronic ballast meets ANSI C82.11 standards regarding harmonic distortion. The EXLUX 6408 Series are designed for hostile and hazardous locations where reliability and rugged performance are critical. The housing is constructed of heavy-duty fiberglass reinforced polyester (FRP) with a single piece, low glare polycarbonate lens. Cable gland for cable installation Hub for conduit installation INSTALLATION The fixture includes threaded NPT openings with grounded backplates and NPT close-up plugs. For MC Cable installation use TMC cable glands. For conduit installation use conduit hub 8166/11-0 -N. The fixture must be wired with a permanent charging phase which needs to be the same potential as the switched phase. The appropriate lamps are standard T8 medium bipin lamps. B4

LIGHTING Dimensions EXLUX 6000, 6400 & 6408 EXLUX 6008 L1 L2 L3 L1 L2 L3 For 3/4" NPT Both Ends 8.7" 221mm For 3/4" NPT Both Ends 8.7" 221mm 5.6" 143mm 143mm 5.6" 5.6" 143mm M1476K M1478K Dimensions 17W, 2' Fixture inch mm 32W, 4' Fixture 40W, 5' Fixture inch mm inch mm Dimensions 17W, 2' Fixture inch mm 32W, 4' Fixture inch mm L1 L2 1) L3 2) 27.5" 15.7" 12.3"-18.3" (700mm) (400mm) (312-465mm) 51.5" 31.5" 26.3"-34" (1310mm) (800mm) (670-865mm) 63.4" 31.5" 26.3"-34" (1610mm) (800mm) (670-865mm) L1 L2 1) L3 2) 30.8" (782mm) 15.7" (400mm) 12.3"-18.3" (312-465mm) 54.8" (1392mm) 31.5" (800mm) 26.4"-34" (670-865mm) 1) fixed mounting distance 2) variable mounting distance 1) fixed mounting distance 2) variable mounting distance B5

Parts and Accessories LIGHTING Use only the following original spare parts and accessories, any others would invalidate the certification and warranty. Description Type Catalog Number Interlock Switch 8082/1-2 Interlock switch 1 NO 80 820 02 01 0 for battery enclosure 6008 fixture Socket Wrench to operate the central 81 980 05 40 0 1/2'' (13mm) interlock mechanism Entry Back-up Plate stainless steel back-up plate with set screw and grounding provisions 1 x NPT 1/2'' 60 008 17 55 0 entry threads: 2 x NPT 1/2'' 60 008 21 55 0 1 x NPT 3/4'' 60 008 18 55 0 Lamp Holder snap-in lamp holder for 6400 and 6408 fixtures 385 663 0 Lamp Holder snap-in lamp holder for 6000 and 6008 fixtures 60 418 04 65 0 Battery Pack for Battery capacity 7Ah 60 448 01 74 0 fixture 6008 Eye Bolts M8 1 pair can directly be screwed 60 008 03 90 0 into the fixture Mounting Brackets with 1 pair of adjustable mounting brackets 60 008 07 75 0 Suspension Lugs with suspension lugs Ceiling Brackets 1 pair of adjustable ceiling 60 008 03 75 0 mounting brackets Pipe Clamps with Mounting Brackets 1 pair of stainless steel pipe clamps with adjustable mounting brackets for EMT 1 1/4" conduit 60 008 03 26 0 EMT 1 1/2" conduit 60 008 01 26 0 EMT 2" conduit 60 008 02 26 0 B6

LIGHTING Parts and Accessories Description Type Catalog Number Wall-Mounting Bracket 90 1 pair of 90 stainless steel 60 008 02 44 0 wall-mounting brackets Wall-Mounting Bracket 50 1 pair of 50 stainless steel 60 008 01 44 0 wall-mounting brackets Safety Clips 10 pcs. in one bag 60 008 02 94 0 to avoid unintentional detachment of the lens from the fixture. Cable Gland 1/2'' NPT for MC cable TMC 050 Sealing Ring 1/2'' NPT for above TMC 050 CMP 050 NPT ETS Cable Gland 3/4'' NPT for MC cable TMC 075 Sealing Ring 3/4'' For above TMC 075 CMP 075 NPT ETS Conduit Hub 1/2'' NPT Conduit hub 1/2'' NPT 8166/11-01-N with sealing ring Conduit Hub 3/4'' NPT Conduit hub 3/4'' NPT 8166/11-02-N with sealing ring Close-up Plug 1/2'' NPT Polymeric close-up plug 1/2'' NPT PD-E-4-0-29-00 B7

Parts and Accessories LIGHTING Description Type Catalog Number Close-up Plug 3/4'' NPT Polymeric close-up plug 3/4'' NPT PD-E-4-0-30-00 Cast Wall and Corner Insert 1 1/2" EMT conduit into Mounting Bracket for the bracket. Use pipe clamp 461 717 0 Stanchion Mounting PN 60 008 01 26 0 to attach fixture to conduit. Lens for light fixture 2' 17W 60 000 33 05 0 4' 32W 60 000 34 05 0 5 40W 60 000 35 05 0 Interlock Switch Switch block 2 NC 80 800 06 60 0 8080/1 3-L 20e Fuse to protect battery circuit 6.3A 85 600 19 01 0 Retrofit Kit for 6 Wire Feed-Through Wiring to retrofit dead-end fixture EXLUX 6008 amperage rating 16 Amp max. or EXLUX 6008 L I, L1, L2, L3, N, PE 4' 32W 60 088 04 87 0 to retrofit dead-end fixture EXLUX 6000 Retrofit Kit for 5 W ire amperage rating 16 Amp max. Feed-Through Wiring L1, L2, L3, N, PE for EXLUX 6000 2' 17W 60 088 12 87 0 4' 32W 60 088 14 87 0 5' 40W 60 088 16 87 0 Electronic for use with fixtures 1x 17W 60 420 65 01 0 Ballast Unit EXLUX 6000, 6008 2x 17W 60 420 53 01 0 & 6400/5..-8090-125 1x 32/40W 60 420 66 01 0 2x 32W 60 420 54 01 0 2x 40W 60 420 55 01 0 Auto Testing for use with Emergency Lighting Fixtures 60 430 18 74 0 Emergency EXLUX 6008 Ballast Parabolic Reflector For 1-lamp fittings 17W 60 309 03 58 0 For 1-lamp fittings 32W 60 309 04 58 0 For 1-lamp fittings 40W 60 309 06 58 0 For 2-lamp fittings 17W 60 309 01 58 0 For 2-lamp fittings 32W 60 309 02 58 0 For 2-lamp fittings 40W 60 309 05 58 0 B8

LIGHTING ECOLUX 6600 Series EXPLOSION PROTECTED FLUORESCENT LIGHTING FIXTURES FOR HAZARDOUS AND CORROSIVE APPLICATIONS CLASSIFICATIONS NEC- Class I, Zone 2, Group IIC T5 Class I, Division 2, Groups A,B,C,D Class II, Divisions 1 & 2, Groups E,F,G NEMA 3, 4, 4X & IP66 File No. J.I.3012747 CEC- Class I, Zone 2, Group IIC T5 Class I, Division 2, Groups A,B,C,D Class II, Divisions 1 & 2, Groups E,F,G CSA ENCLOSURES TYPE 3,4 & 4X; IP66 Certified File No. 171050 Ambient Temperature Range: +40 C (+104 F) Max.; -18 C (0 F) Min. Supply Voltages (see ordering information) FEATURES The ECOLUX 6600 Series of Lighting Fixtures are designed for hostile and hazardous locations where reliability and rugged performance are critical. The housing is constructed of heavy-duty fiberglass reinforced polyester (FRP) with a single piece, low glare polycarbonate lens. The ECOLUX 6600 Series is supplied with electronic instant-start ballasts as standard and is available in 17, 32 and 40-Watt, one or two-lamp versions. The two-lamp versions are dual channel, which keeps the fixture functional should one lamp fail. The power factor is.99. The electronic ballast meets ANSI C82.11 standards regarding harmonic distortion. INSTALLATION The fixture includes threaded NPT openings with grounded backplates and NPT close-up plugs. For MC Cable installation use TMC cable glands. For conduit installation use conduit hub 8166/11-0 -N. The appropriate lamps are standard T8 medium Bi-pin lamps. Fluorescent Lighting Fixtures for Div. 2 and Zone 2 Applications Fixtures for Use with Standard T8 Med. Bi-pin Lamps Ordering Information Catalog Number 17 Watt, 2' 6600/531-8090-9000-120-277-50/60 1-lamp fixture 120-277V 50/60Hz, Entries: * 6600/531-8090-9000-347-60 1-lamp fixture 347V 60Hz, Entries: * 6600/532-9090-9000-120-277-50/60 2-lamp fixture 120-277V 50/60Hz, Entries: * 6600/532-9090-9000-347-60 2-lamp fixture 347V 60Hz, Entries: * 32 Watt, 4' 6600/551-8090-9000-120-277-50/60 1-lamp fixture 120-277V 50/60Hz, Entries: * 6600/551-8090-9000-347-60 1-lamp fixture 347V 60Hz, Entries: * 6600/552-9090-9000-120-277-50/60 2-lamp fixture 120-277V 50/60Hz, Entries: * 6600/552-9090-9000-347-60 2-lamp fixture 347V 60Hz, Entries: * 40 Watt, 5' Description 6600/571-8090-9000-120-277-50/60 1-lamp fixture 120-277V 50/60Hz, Entries: * 6600/572-9090-9000-120-277-50/60 2-lamp fixture 120-277V 50/60Hz, Entries: * For optional cover interlock switch change these 0 s to 1 s. * Possible entries either end: 1 x 1/2", or 2 x 1/2", or 1 x 3/4" NPT. Please specify. For parts and accessories see pages B11-B13. B9

ECOLUX 6608 Series LIGHTING EXPLOSION PROTECTED FLUORESCENT EMERGENCY LIGHTING FIXTURES FOR HAZARDOUS AND CORROSIVE APPLICATIONS CLASSIFICATIONS NEC- Class I, Zone 2, Group IIC T5 CEC- Class I, Division 2, Groups A,B,C,D Class II, Divisions 1 & 2, Groups E,F,G NEMA 3, 4, 4X & IP66 File No. J.I.3012747 CEC- Class I, Zone 2, Group IIC T5 Class I, Division 2, Groups A,B,C,D Class II, Divisions 1 & 2, Groups E,F,G CSA ENCLOSURES TYPE 3,4 & 4X; IP66 Certified File No. 171050 Ambient Temperature Range: +40 C (+104 F) Max. -18 C (0 F) Min. Emergency Fluorescent Lighting Fixtures with Battery Back-up Unit for Div. 2 and Zone 2 Applications Fixtures for use with Standard T8 Med. Bi-pin Lamps Ordering Information Catalog Number 17 Watt, 2' 32 Watt, 4' Description 6608/532-9098-9000-120-277-50/60 2-lamp fixture 120 to 277V 50/60Hz, Entries: * 6608/552-9098-9000-120-277-50/60 2-lamp fixture 120 to 277V 50/60Hz, Entries: * * Possible entries either end: 1 x 1/2", or 2 x 1/2", or 1 x 3/4" NPT. Please specify. For parts and accessories see pages B11-B13. Supply Voltage Range from 120V, to 277V, 60 Hz FEATURES The ECOLUX 6608 Series of Emergency Lighting fixture is equipped with one battery back-up unit which in case of power failure automatically switches over to battery supply keeping one lamp illuminated at reduced lumen output for a minimum of 90 minutes. When AC power is restored, the fixture returns to AC supply. When the Red LED indicating light is illuminated the battery is being charged or monitored. It is visible from the outside through the lens. The ECOLUX 6608 Series is also supplied with an AC electronic instant start ballast unit and is available in 2 x 17W or 2 x 32W parallel lamps. This keeps the fixture functional should one lamp fail. The power factor is.99. The electronic ballast meets ANSI C82.11 standards regarding harmonic distortion. The ECOLUX 6608 Series are designed for hostile and hazardous locations where reliability and rugged performance are critical. The housing is constructed of heavy-duty fiberglass reinforced polyester (FRP) with a single piece, low glare polycarbonate lens. Cable gland for cable installation Hub for conduit installation INSTALLATION The fixture includes threaded NPT openings with grounded backplates and NPT closeup plugs. For MC Cable installation use TMC cable glands. For conduit installation use conduit hub 8166/11-0 -N. The fixture must be wired with a permanent charging phase which needs to be the same potential as the switched phase. The appropriate lamps are standard T8 medium Bi-pin lamps. B10

LIGHTING Dimensions ECOLUX 6600 & 6608 Dimensions Opening the Fixture 17 W 32 W 40 W L1 L2 L3 700 mm 1310 mm 1610 mm 27.5" 51.6" 63.4" 400 mm 800 mm 800 mm 15.75" 31.5" 31.5" 340-460 mm 680-920 mm 795-1030 mm 13.4" - 18.1" 26.8" - 36.2" 31.3" - 40.5" Parts and Accessories Use only the following original spare parts and accessories, any others would invalidate the certification and warranty. Item Image Description Catalog Number Conduit Hub 1/2'' NPT Conduit hub 1/2'' NPT 8166/11-01-N with sealing ring Conduit Conduit hub 3/4'' NPT 8166/11-02-N Hub 3/4'' NPT with sealing ring Close-up plug 1/2'' NPT Polymeric close-up plug 1/2'' NPT PD-E-4-0-29-00 Close-up plug 3/4'' NPT Polymeric close-up plug 3/4'' NPT PD-E-4-0-30-00 For retro-fitting Parabolic Reflector for 1-lamp fixtures: (Optional) 17W 60 309 03 58 0 32W 60 309 04 58 0 for 2-lamp fixtures: 40W 60 309 06 58 0 17W 60 309 01 58 0 32W 60 309 02 58 0 40W 60 309 05 58 0 B11

Parts and Accessories LIGHTING Use only the following original spare parts and accessories, any others would invalidate the certification and warranty. Item Image Description Catalog Number Cast wall and corner Insert 1 1/2" EMT conduit into bracket mounting bracket for Use pipe clamps (PN 66 008 01 26 0) 461 717 0 stanchion mounting to attach fixture to conduit S0613P Lens for light fixture 2' 17W 66 000 01 05 0 4' 32W 66 000 02 05 0 5' 40W 66 000 03 05 0 Color: White 10 Pieces 66 008 01 40 0 Snap Action Buckles Color: Black 6 Pieces 66 008 02 40 0 Color: Black 2 Pieces 66 008 03 40 0 with a borehole for switch actuation Lamp Holder snap-in lamp holder 385 663 0 Entry back-up plate Eye bolts M8 stainless steel back-up plate with set screw and grounding provisions entry threads: 1 x NPT 1/2'' 60 008 17 55 0 2 x NPT 1/2'' 60 008 21 55 0 1 x NPT 3/4'' 60 008 18 55 0 1 pair of eye bolts M8 can be directly screwed 60 008 03 90 0 into the inserts of the fixture for fixed suspension points Ceiling Mounting brackets 1 pair of fixed ceiling mounting brackets 60 008 03 75 0 for fixed mounting points B12

LIGHTING Parts and Accessories Item Image Description Catalog Number Mounting Brackets 1 pair of mounting brackets for adjustable mounting points 66 008 01 75 0 1 pair of stainless steel suspension lugs which can only be used together with mounting brackets 60 008 02 18 0 P/N 66 008 01 75 0 Suspension Lugs 1 pair of stainless steel suspension lugs c/w 66 008 02 75 0 adjustable mounting brackets for adjustable suspension points Pipe Clamps 1 pair of stainless steel pipe clamps c/w adjustable mounting brackets for adjustable mounting points EMT 1 1/4" 66 008 05 26 0 EMT 1 1/2" 66 008 01 26 0 EMT 2" 66 008 02 26 0 1 pair of stainless steel wall mounting brackets Tiltable Wall which tilt at 15 increments complete with Mounting bracket adjustable mounting brackets for adjustable 66 008 04 26 0 mounting points Clamps for 1 pair of stainless steel brackets suitable for Wire Basket Systems fastening fixture to a wire basket system 66 008 03 26 0 Cable Gland 1/2'' NPT For standard MC Cable TMC 050 Sealing ring 1/2'' NPT For above TMC 050 CMP 050 NPT ETS Cable Gland 3/4'' NPT For standard MC Cable TMC 075 Sealing ring 3/4'' For above TMC 075 CMP 075 NPT ETS B13

C-LUX 6500 Series LIGHTING EXPLOSION PROTECTED COMPACT LIGHTING FIXTURES FOR HAZARDOUS AND CORROSIVE INDOOR APPLICATIONS CLASSIFICATIONS NEC- Class I, Zone 2, Group IIC T4 Class I, Division 2, Groups A,B,C,D, T4 Class II & III, Divisions 1 & 2, Groups E,F,G, T5 Enclosure Type 3, 4, 4X & IP66 File No. J.I.3012168 Ambient Temperature Range: +45 C (+113 F) Max.; +10 C (+50 F) Min. Supply Voltage: 120V, 60 Hz Compact Fluorescent Lighting Fixtures for Div. 2 and Zone 2 Applications Fixtures for use with T5 Miniature. Bi-pin 8 W att Lamp(s). Ordering Information Catalog Number 6500/1081-9090-9000-00-120-60 1-lamp fixture 120V 60Hz, 3/4" NPT Entries 6500/1082-9090-9000-00-120-60 2-lamp fixture 120V 60Hz, 3/4" NPT Entries 6500/1083-9090-9000-00-120-60 3-lamp fixture 120V 60Hz, 3/4" NPT Entries For other entry openings, consult factory. For parts and accessories see page B15. Dimensions Description FEATURES The C-LUX 6500 Series of Lighting Fixtures are small compact fixtures designed for indoor use, hostile and hazardous locations where reliability and rugged performance are critical. The housing is constructed of heavyduty fiberglass reinforced polyester (FRP) with a single piece, low glare polycarbonate lens. The C-LUX 6500 Series is available either as a one, two or three-lamp version. INSTALLATION The fixture is suitable for wall or ceiling mounting. It includes one threaded 3/4" NPT hub and two close-up plugs. To open the fixture use 1/2" socket wrench P/N 81 980 05 40 0. For parts and accessories see page B15. B15 B14

LIGHTING Parts and Accessories Use only the following original spare parts and accessories, any others would invalidate the certification and warranty. Item Image Description Catalog Number Lens for light fixture C-LUX 6500/1 61 000 01 05 0 Lamp Holder snap-in lamp holder for C-LUX 6500/1 385 647 0 Socket Wrench To operate the central 81 980 05 40 0 1/2'' (13mm) interlock mechanism Conduit Hub 3/4'' NPT For conduit entries on small and long side 82 959 39 37 0 Sealing Ring 3/4'' For above Hub P/N 82 959 39 37 0 515 795 0 Close-Up Plug Close-Up Plug M25 82 900 09 59 0 8290/3 M25 x 1.5 B15 B16