Auto Flow 20 Questions 20 Answers. Joseph Fitzgerald



Similar documents
AutoFlow The Oxylog 3000 plus incorporates the benefits of pressure controlled ventilation into volume controlled ventilation

Two Steps forward in Ventilation. Ernst Bahns. Because you care

Curves and Loops in Mechanical Ventilation. Frank Rittner Martin Döring

Airway Pressure Release Ventilation

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

MECHINICAL VENTILATION S. Kache, MD

Impact Uni-Vent 754 Portable Ventilator

The Anesthesia Ventilator

For every breath he takes. Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home.

Your personal anesthesia assistant DRÄGER PRIMUS

Oxylog 3000 plus Emergency & Transport Ventilation

The Anesthesia Ventilator

D Curves and Loops in Mechanical Ventilation Frank Rittner Martin Döring

Puritan Bennett 980 Ventilator Patient Setup Quick Reference Guide

Ventilation modes in intensive care

Dräger Ventilation Mini Manual Brief explanation of ventilation modes and functions

Artificial Ventilation Theory into practice

From AARC Protocol Committee; Subcommittee Adult Critical Care Version 1.0a (Sept., 2003), Subcommittee Chair, Susan P. Pilbeam

Dräger Evita Infinity V500 ventilator ICU Ventilation and Respiratory Monitoring

BIPAP Synchrony TM AVAPS

DATA SHEET. Capnography option. November 2013 V2.2

Common Ventilator Management Issues

INTRODUCING RESMED S. Home NIV Solutions. S9 VPAP ST-A with ivaps S9 VPAP ST. Why choose average when you can choose intelligent?

Polaris 5xx/7xx Medical Lights and Video

Volume Guarantee New Approaches in Volume Controlled Ventilation for Neonates. Jag Ahluwalia, Colin Morley, Hans Georg Wahle

2000 Respironics, Inc. All rights reserved.

Mechanical Ventilation for Dummies Keep It Simple Stupid

MEDICAL SYSTEMS. Monnal T60. Touch and Breathe.

Neurally Adjusted Ventilatory Assist: NAVA for Neonates

Impact Uni-Vent 750 Portable Ventilator

D Pressure Support Ventilation A New Triggered Ventilation Mode for Neonates. Jean Christophe Rozé Thomas Krüger

GE Healthcare. Avance Carestation. Innovating with you, shaping exceptional care

Ventilator Application of the Passy-Muir Valve David A. Muir Course Outline Benefits Review of the Biased Closed Position No Leak Passy-Muir Valves

3100B Clinical Training Program. 3100B HFOV VIASYS Healthcare

A simple solution for your complex patients. The market-leading servo ventilation device System One BiPAP autosv

MEDUMAT Easy CPR The Guiding Emergency Ventilator

POCKET GUIDE. NAVA and NIV NAVA in neonatal settings

Puritan Bennett 840 Ventilator User s Pocket Guide. Puritan Bennett 840 Ventilator Pocket Guide

Dräger Alcotest 9510 Evidential Alcohol Measuring Device

Critical Care Therapy and Respiratory Care Section

The centrepiece of a complete anaesthesia workstation

Table of contents. Exercise 1 Passive exhalation port 13. Exercise 2 Active exhalation valve 15

Operator s Instruction Manual

FLOW-i ANESTHESIA DELIVERY SYSTEM

D Non-Invasive Ventilation (NIV) with the Oxylog 2000 plus and Oxylog 3000 plus

Technical Service Manual Babylog 8000/8000SC/8000 plus Intensive Care Ventilator

Dräger Babylog VN500 Neonatal Open Care

Fabius GS. Inhalation Anesthesia Machine Software 3.n Operating Instructions. Because you care

Airways Resistance and Airflow through the Tracheobronchial Tree

D Gas supply secure at a glance DRÄGER ALARM MANAGEMENT SYSTEM

Tests. Pulmonary Functions

Boaray 700 Anesthesia Machine

2.06 Understand the functions and disorders of the respiratory system

Oxygenation and Oxygen Therapy Michael Billow, D.O.

Carina Pocket Guide Software version 3.n. The Carina Pocket Guide is not a replacement or substitute for the Instructions for Use.

Dräger X-dock Release Notes Software-Update and Manager Software 1.7.0

A platform to trust The system solution for treatment of respiratory disorders.

Effective Treatment for Obstructive Sleep Apnoea

Home Ventilator Breath of Life Home Medical Equipment and Respiratory Services

Vivo 50/60 PC Software Help (english), version Introduction. 3. Dialogs. 7. Year data view. 8. Alarm view. 2. User interface. 9.

Sleep Therapy I Ventilation I Patient Interface. Sleep Therapy. Sleep therapy solutions for every patient

Dräger PSS 3000 Self Contained Breathing Apparatus

Mechanical Ventilation

PULMONARY FUNCTION TESTS A Workshop on Simple Spirometry & Flow Volume Loops

Datex Ohmeda. Centiva /5. Service Manual Software rev. 2.1n

D A cost effective monitor that meets your clinical needs VISTA 120

Understanding Hypoventilation and Its Treatment by Susan Agrawal

COURSE SYLLABUS RC 223 CLINICAL-3

Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003

Sekusept Cleaner Liquid Cleaning Agent Cleaning, Desinfecting and Drying

RESPIRATORY VENTILATION Page 1

GE Healthcare. Welcome to the future of anesthesia Aisys * Carestation *

Dräger PARAT Escape Hoods

LUNG VOLUMES AND CAPACITIES

FLIGHT MEDICAL INNOVATIONS LTD. FLIGHT 50 Ventilator. Service Manual. DOC-0004 Rev B. Sep 2012

How To Determine The Difference Between Long Versus Short Inspiratory Times In Neonates

Central, mixed and obstructive sleep apnea patient

SARASOTA MEMORIAL HOSPITAL DEPARTMENT POLICY

MECHANICAL VENTILATION: AN OVERVIEW

VELA. ventilator user guide. Critical care ventilation

Titration protocol reference guide

Lab #11: Respiratory Physiology

Titration protocol reference guide

Sensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care

Aliseo Anesthesia system

Standard Operating Procedure

Edwards FloTrac Sensor & Edwards Vigileo Monitor. Understanding Stroke Volume Variation and Its Clinical Application

High-Frequency Oscillatory Ventilation

Introduction to Cardiopulmonary Exercise Testing

GRADE 11F: Biology 3. UNIT 11FB.3 9 hours. Human gas exchange system and health. Resources. About this unit. Previous learning.

S/5 Anesthesia Monitor. The clinician s choice

Non-invasive ventilation in acute respiratory failure

Department of Surgery

CENTER FOR KLINISKE RETNINGSLINJER - CLEARINGHOUSE

Recommendations: Other Supportive Therapy of Severe Sepsis*

Pre-lab homework Lab 6: Respiration and Gas exchange

Forced vital capacity: maximal volume of air exhaled with maximally forced effort from a maximal inspiration.

Operating Manual. Newport Medical Instruments, Inc. NEWPORT HT50 VENTILATOR. OPRHT50NA Rev. B September Exclusively Distributed by:

MECHANICAL VENTILATION IN THE NEONATE

Trilogy200. Proximal pressure line. Exhalation valve line. Quick start guide. Overview. Circuit set-up. Set-up screen. Prescription set-up

Transcription:

Auto Flow 20 Questions 20 Answers Joseph Fitzgerald

Important Notice: Medical knowledge changes constantly as a result of new research and clinical experience. The author of this introductory guide has made every effort to ensure that the information given is completely up to date, particularly as regards applications and mode of operation. However, responsibility for all clinical measures must remain with the reader. Written by: Dräger Medizintechnik GmbH Joseph Fitzgerald Moislinger Allee 53/55 23542 Lübeck Germany All rights, in particular those of duplication and distribution, are reserved by Dräger Medizintechnik GmbH. No part of this work may be reproduced or stored in any form using mechanical, electronic or photographic means, without the written permission of Dräger Medizintechnik GmbH. ISBN 3-926762-40-3

Auto Flow 20 Questions 20 Answers Joseph Fitzgerald

4 20 Questions 20 Answers using AutoFlow Contents What is AutoFlow? 6 Is AutoFlow a new Ventilator Mode? 7 When would you use AutoFlow? 8 How does AutoFlow compare to BIPAP 9 How is AutoFlow combined with other modes such as IPPV? 10 How does AutoFlow work with SIMV? 11 How does AutoFlow work with MMV? 12 How does ventilation with AutoFlow compare with volume controlled ventilation? 14 How does ventilation with AutoFlow compare to pressure regulated modes? 15 What type of lung diseases is AutoFlow suitable for? 16 Are there situations where it is not indicated? 17 What has to be considered when switching from conventional modes to AutoFlow? 18 How do you set up AutoFlow? 19 What monitoring parameters are important to observe when using AutoFlow? 20

20 Questions 20 Answers using AutoFlow 5 What are the advantages to observe when using AutoFlow? 22 What would be the subsequent management of the patient? 23 What are the safeguards against hypo/hyperinflation? 24 How does AutoFlow interact with inverse ratio ventilation? 25 How can mechanical ventilation and spontaneous breathing be mixed in one mode? 26 What is the technology behind this latest advance in therapy? 28 Explanatory note: In some regions of the world IPPV mode of ventilation is referred to as CMV and Assist/CMV. The mode BIPAP is referred to as PCV+ in the USA and Canada. BIPAP* is trademark used under licence. AutoFlow is registered as a trademark of Dräger Medizintechnik GmbH.

6 20 Questions 20 Answers using AutoFlow 1. What is AutoFlow? This is a new advance in volume controlled modes of mechanical ventilation where the ventilator automatically regulates inspiratory flow. This auto regulation is in accordance with the set V T and current lung compliance. The set V T is always given at minimum possible pressure and spontaneous breathing is possible (open valves) through the whole Inspiratory and Expiratory phases of the mechanical ventilatory cycle. A decelerating flow pattern reduces Peak pressures and as lung compliance changes further they are recognised and responded to. A decelerating flow pattern reduces Peak pressures Flow Volume Controlled Switch-on AutoFlow V T V T

20 Questions 20 Answers using AutoFlow 7 2. Is AutoFlow a new Ventilator Mode? It is a new addition to all volume controlled modes on the Evita 4 and Evita 2 dura ventilator. It is not a mode independently selected in itself. It could be compared to the way one function enhances another such as flow trigger enhances pressure support. It is intended to simplify strategies in mechanical volume controlled ventilation by offering more patient benefits with a wider therapy range and with less parameters to adjust.

8 20 Questions 20 Answers using AutoFlow 3. When would you use AutoFlow? There are very few exceptions to using AutoFlow in all volume oriented modes where it is available. In general we can divide its use into two areas, that of the type of ventilatory strategy we want to apply and that of the type of patient that it is particularly suited to. In the first case in volume strategy ventilation where we want to reduce high airway pressures and capitalise on spontaneous breathing with reduced use of sedation and muscle relaxants. The decelerating flow and the regulated inspiratory and expiratory valves provide a response to every inhalatory and exhalatory effort of the patient. This feels like breathing through an open system. In other strategies we may want to use inverse ratio timings. The occlusion of the expiratory valve for such lengths of time can produce risk of barotrauma for a patient who becomes awake and starts breathing. With an open breathing system this risk is greatly reduced. In terms of patient types, there are those with quite variable compliance levels after surgery who require careful manipulation of inspiratory pressure and volume to prevent barotrauma and hyperinflation. AutoFlow continually adjusts the pressures as compliance changes to ensure volume delivery at the lowest possible pressures. Finally, as a smooth weaning strategy we want the first efforts by the patient to be responded to in all phases of the mandatory stroke unlike conventional modes of SIMV where there are closed phases in the cycle. The fixed set V T delivery of SIMV is also addressed for Bronchospasm patients with air hunger as all demands for flow and volume are responded to by the ventilator.

20 Questions 20 Answers using AutoFlow 9 4. How does AutoFlow compare to BIPAP? BIPAP has been established for a number of years as a real advance in pressure controlled ventilation strategies. Pressures are regulated at a specific value and pressure peaks are eliminated and together with time synchronisation the patient is able to breathe spontaneously at any stage. Many of these features are now transferred across into the volume controlled modes as the benefits of this therapy have become more extensively accepted. The prime parameter setting in BIPAP is inspiratory pressure (Pinsp) and tidal volume (V T ) is variable, the prime adjustment in AutoFlow is V T and the pressure is the variable, depending on the compliance. Many benefits of BIPAP are transferred into volume controlled modes with AutoFlow

10 20 Questions 20 Answers using AutoFlow 5. How is AutoFlow combined with other modes such as IPPV? The addition of AutoFlow to IPPV mode for example is achieved by the on-going measurement of pressure, flow, volume and lung compliance and a ventilator response that regulates the flow to achieve the set V T in the inspiratory time available. When you switch on there is a change from manual control to an automatic control of the inspiratory flow. Other than the removal of the control knobs of pressure (P max ) and flow from the touch screen panel all the core settings including trigger function and pressure support capability are totally unaffected. The core settings including trigger function and pressure support are unaffected.

20 Questions 20 Answers using AutoFlow 11 6. How does AutoFlow work with SIMV? AutoFlow supports the preservation of an intact respiratory drive as less sedation and muscle relaxants are used. Equally in SIMV any of the usual parameters such as PEEP are fully functional and superimposing AutoFlow brings auto-regulation to the flow and pressure. The associated potential advantages have a domino effect in that a lower peak pressure usually means a lower mean airway pressure with a positive effect on haemodynamics, the inspiratory flow varies according to individual patient needs and may alter on a breath to breath basis. AutoFlow supports the preservation of an intact respiratory drive as less sedation and muscle relaxants are used. The matching of flow and volume to patient needs in synchrony with inspiratory time at minimum pressure promotes harmony between patient and ventilator. This reduces considerably the phenomena known as fighting the ventilator which is a misnomer in that the ventilator fights the patient with its imposed fixed settings.

12 20 Questions 20 Answers using AutoFlow 7. How does AutoFlow work with MMV? No ventilator adjustment required when going from fully controlled ventilation to full spontaneous breathing. The mode is similar to SIMV in many respects where the clinician sets a rate and V T for the patient to satisfy adequate gaseous exchange. It differs from SIMV in that as spontaneous breathing activity increases and the patient achieves more than the set mandatory minute volume then the mechanical strokes fade into the background. The patient, often with the aid of pressure support takes over the full volume work of minute ventilation. In MMV, AutoFlow influences the mechanical strokes if present and reduces asynchrony by allowing spontaneous breathing activity and reducing pressures to a minimum. The logical progression of this is that the patient can be sedated and on full controlled ventilation, as he wakes up he will still get mechanical strokes but he will be able to breathe through them and not experience any discomfort with these breaths,as his contribution increases the ventilator breaths fade away completely so the patient does not have to be switched to a weaning mode. In addition to this if we now use the Ideal Body Weight setting and programme the weight into the ventilator before start of therapy then the right volume and ventilator settings will be selected for that patient and appropriate alarm defaults also. All this means that post operatively we can easily select what we want for the patient and in straight forward ventilation cases we can start with full ventilation therapy and go right through to full spontaneous breathing without having to readjust the ventilator.

20 Questions 20 Answers using AutoFlow 13 MMV AutoFlow Controlled Ventilation Spont. efforts and mandatory phases Total spontaneous efforts CPAP with pressure support Select Ideal Body Weight (70 kg). Key values and alarms set automatically Ideal body weight 70 kg Set ventilator to standby function. Connect arriving patient. Start ventilation Record monitored parameters Maintain observation of the patient as they wake up.

14 20 Questions 20 Answers using AutoFlow 8. How does ventilation with AutoFlow compare with volume controlled ventilation? Paw Flow controlled fixed flow inspiration closed in The constant flow in Volume controlled modes does not always match inspiration times, flow and volume do not always match patient demand leading to asynchrony. Peak pressures are often high sedation and paralysis are used to adapt patient to the ventilator. Spontaneous breathing if allowed is a futile struggle against closed valves. Attempts to exhale during mandatory phase activate patient activity high airway pressure alarms. The freedom for the patient to cough freely and clear his own secretions during volume controlled modes is usually suppressed. In any situation AutoFlow always provides safety t and lower pressures compared to normal volume controlled modes. expiration closed ex t

20 Questions 20 Answers using AutoFlow 15 9. How does ventilation with AutoFlow compare to pressure regulated modes? AutoFlow decelerates flow automatically similar to pressure controlled ventilation. Inspiratory pressure follows compliance similar to plateau pressure in volume controlled ventilation. It differs from conventional pressure limited modes and Pressure Regulated Volume modes in allowing spontaneous breathing at any phase. It guarantees a set V T and keeps pressure to a minimum whereas pressure controlled modes keep pressure constant and allow the V T to vary. AutoFlow brings many of the features of PCV to volume oriented modes and allows the benefits experienced by BIPAP users for example to be shared with those who wish to pursue volume only strategies. controlled patient activity Paw t Flow in expiration closed ex t

16 20 Questions 20 Answers using AutoFlow 10. What type of lung diseases is AutoFlow suitable for? The use of AutoFlow is indicated as part of a volume oriented strategy in all cases where you can expect quick changes and short term improvement of lung compliance. It is recommended in post surgical cases where acute restriction is evident and you want to guarantee normal ventilation. In acute lung oedema where high airway pressures are initially acceptable but as the treatment programme takes effect pressures will go down automatically and volumes will stay constant. Using AutoFlow with a volume controlled mode is easier to handle than pressure control in this situation. In cases where local atelectasis resulting from trauma or pneumonia requires frequent repositioning of the patient, in these situations Pressure Control would produce great volume changes and AutoFlow in volume control modes will provide stable volumes at minimum pressures. Finally, AutoFlow is suitable for all start up ventilation therapy scenarios where there is limited information on disease status available and it is important to get therapy underway where pressures and flow are regulated and spontaneous activity is not compromised.

20 Questions 20 Answers using AutoFlow 17 11. Are there situations where it is not indicated? The range of uses of AutoFlow is determined by the limitations of volume controlled modes and these modes are not always recommended for very severe diseases with long term healing processes with several days to weeks required to improve lung conditions. These cases where Acute Lung Injury and ARDS are clearly established often require a defined pressure control strategy such as BIPAP or APRV mode where the small volumes associated with the reopening lung are essential for blood gas improvement. Current opinion among the experts advocate reducing the risk of barotrauma by regulation of pressure and minimal volume strategy. Volume controlled ventilation may not be indicated where there is a risk of intrinsic PEEP and the associated danger of over inflating the lung in a volume controlled strategy, especially where there are obstructive disorders or long (inverse) ratios are required. In these cases BIPAP mode with respect to decelerating flow and spontaneous breathing activity has the same advantages as AutoFlow. Lung disease is the real indicator and pressure or volume strategy is selected accordingly.

18 20 Questions 20 Answers using AutoFlow 12. What has to be considered when switching from conventional modes to AutoFlow? The important point is that settings stay the same and if there is no patient activity there will be no variance in V T. PEEP and Tinsp and mandatory frequency remain stable. Setting the flow control is not necessary as there is automatic regulation. As in all volume control modes setting the upper Paw alarm is important for the upper pressure threshold. Ventilation related sedation can be reduced to avail of the full benefits of spontaneous breathing. Pressure Volume Controlled Switch-on AutoFlow Compliance improvement P insp

20 Questions 20 Answers using AutoFlow 19 13. How do you set up AutoFlow? AutoFlow is switched on through extra settings on touch screen and rotary confirm knob. Conventional parameters Freq, Tinsp, V T and PEEP are set as desired. Upper Paw alarm should be set to warn of sudden compliance decrease or resistance increase and subsequent pressure changes. Upper Insp V T alarm can be set to indicate increasing spontaneous breathing V T demands. Set up operation is by following screen prompts.

20 20 Questions 20 Answers using AutoFlow 14. What monitoring parameters are important to observe when using AutoFlow? In case the V T is not applied a V T low alarm is automatically generated. On switch on Peak pressure decreases as flow decelerates Pinsp will adjust as compliance alters. Mean pressures will follow. The inspiratory flow pattern will alter (may lengthen) to accommodate resistance changes. Airway pressure high alarm unlike conventional ventilation will not occur (but should always be set). In case the V T is not applied because of high resistance a V T low alarm is automatically generated. Spontaneous breathing activity will appear on flow curve. No high Paw alarm will activate on active expiration and mean V T equals set V T. Pressure, V T and SB rates are monitored and displayed in any format which is preconfigured. Observance of the PV loops on the screen will show much improved pressure to volume relationships. Trends for many of these parameters provide a good indicator of clinical progress.

20 Questions 20 Answers using AutoFlow 21 Peak pressure decreases with decelerating flow Pinsp adjusts to compliance No high Paw alarm on spontaneous breathing Paw Paw Pinsp. = f (V T,C) PEEP t Flow V T TI 1 f T E t without spontaneous breathing with spontaneous breathing Trends give best overview Spontaneous breathing activity seen on flow curve

22 20 Questions 20 Answers using AutoFlow 15. What are the advantages to observe when using AutoFlow? Peak and Mean airway pressures are reduced. Less invasive, less mechanical controlling by the ventilator. In the presence of leaks AutoFlow recognises and compensates accordingly. Less requirement for sedation and muscle relaxants which have many other systemic effects. Spontaneous breathing contributes to better gas exchange and secretion clearance. Weaning is more smooth and can start earlier. Greater comfort and less stress for patients should in turn reduce stress levels for clinical staff. Finally, the need for fewer control knobs to adjust and less alarms to manage are seen as real advantage in the busy intensive care unit.

20 Questions 20 Answers using AutoFlow 23 16. What would be the subsequent management of the patient? Each case is different but a general strategy during weaning would be to reduce FiO 2, maintain PEEP above lower inflection point, reduce Tinsp to I:E of 1:1 and reduce Frequency. As patient activity increases and patient inhales with the mandatory stroke inspiratory pressures will automatically reduce and the next step is Pressure Support to assist the spontaneous breathing. The significant point of management is the early move to spontaneous breathing because of the open system which allows an early parallel reduction in mechanical ventilation. The use of CPAP combined with Pressure Support to compensate for the work of breathing through the tube is usually indicated as the final therapy stage. The tranisition to final weaning steps is simple and straightforward.

24 20 Questions 20 Answers using AutoFlow 17. What are the safeguards against hypo/hyperventilation? The safeguards against too much or too little volume come in three forms. Firstly the user is prevented from making unusual inadvertent settings by use of on screen advice and having to confirm before being able to implement these settings. Secondly the increasing incremental steps as compliance changes are just 3 mbar and are limited to 5 mbar below the set upper airway pressure alarm. Thirdly, the automatically activated Volume inconstant alarm warns if the set V T is not applied due to compliance or resistance changes. The upper airway pressure alarm warns of extreme coughing or obstruction. The V Ti alarm limits the inspiratory volume in the event of too great a volume demanded. Frequent triggering by the patient does not lead to hyperventilation in the modes SIMV and MMV and where it might have been possible in CMV/Assist the trigger can be turned off but the patient is still allowed to breathe spontaneously.

20 Questions 20 Answers using AutoFlow 25 18. How does AutoFlow interact with inverse ratio ventilation? Pressure end-expiratory alveolar pressure AutoFlow is ideally suited to extended inspiratory times. Flow AutoFlow is an excellent adjunct to long inspiratory time settings. Clinical experience is limited but if we carry across the reported experiences of Sydow et al(2) and apply a ventilatory strategy where spontaneous breathing is encouraged with the longer inspiratory times but overall pressures are low then this should provide a good indication for its use in an IRV format. Not withstanding the impact of air trapping this should actively contribute to reducing the risk of barotrauma which is often associated with IRV.

26 20 Questions 20 Answers using AutoFlow 19. How can mechanical ventilation and spontaneous breathing be mixed in one mode? New microprocessor systems combined with sophisticated valves provide new solutions. To facilitate spontaneous inspiration and expiration in each phase of controlled mechanical ventilation is a technological challenge. This unique solution is based on an intelligent microprocessor system combined with highly sophisticated valves, flow and pressure sensors. Conventional technology with the delivery of fixed flow and volume in each mandatory breath is contrary to free spontaneous breathing by the patient. Volume control with AutoFlow is therefore provided on a breath to breath basis. In each individual breath the patient has the possibility to increase or reduce the delivered volume. The ventilator monitors the inspiratory volume and compensates for deviations in the next breath. In case the volume was too low, volume of the next breath will be automatically adjusted by increased inspiratory pressure (Plateau). If the volume was too high either because of spontaneous inspiration or improving compliance, inspiratory pressure will automatically go down with the next breath. For smooth interaction with the patient the pressure changes are limited to maximum of 3 cm H 2 O from breath to breath. Great pressure fluctuations because of unique events like a cough or a spontaneous sigh are thus avoided.

20 Questions 20 Answers using AutoFlow 27 controlled patient activity Patient in ex t Paw t Flow inspiration open in expiration open ex t AutoFlow responds like a CPAP system with CPAP value set to Pinsp. Whenever the patient tries to inhale more volume the demand valve will deliver more flow, whenever he wants to exhale the expiration valve will allow expiratory flow while the pressure/peep level is kept constant. The graphs above illustrate this. The patient can inhale and exhale as usual in SIMV/ MMV and now even in the expiratory phase of IPPV.

28 20 Questions 20 Answers using AutoFlow 20. What is the technology behind this latest advance in therapy? Expiration valve closed or Expiration valve controlled All the electronic and pneumatic subsystems need to be optimised for a function like AutoFlow. The accurate control of flows and pressures is an essential basic requirement, but only intelligent algorithms and fast adjustments of the valves can provide the required responsiveness to patient activities. Evita ventilators have highly responsive inspiratory demand valves that can open and close in milliseconds on command of the microprocessor system, while keeping the FiO 2 and pressure constant. This minimises patient work of breathing and helps avoid inefficient breathing efforts. The integrated special exhalation valve design with a large control orifice provides low resistance to exhalation. Pressure is controlled smoothly with fast responses throughout the whole setting range of PEEP and inspiratory pressures. As the picture here on the left illustrates, the exhalation valve is never occluded completely, the closing pressure is always equal to the corresponding PEEP or inspiratory pressure. Like a pop off valve it permits expiratory flow if the pressure exceeds the set value. Last but not least accurate and robust pressure and flow sensing systems on both in- and expiratory side are a basis for all these functions.

20 Questions 20 Answers using AutoFlow 29 Summary Statement of Benefits of Auto Flow Physiologic facilitates the recognised importance of spontaneous breathing in controlled ventilation Volume controlled ventilation takes a major step forward. Synchrony Automatic Simplification Evidence flow and volume adapted to patient needs complete weaning therapy in many situations when MMV is combined with Ideal Body Weight and one pre-setting. ventilatory therapy with less control knobs and less alarms All proven benefits of BIPAP now transferred to volume controlled ventilation

Europe, Middle East, Africa: Dräger Medical AG & Co. KGaA Moislinger Allee 53-55 23542 Lübeck GERMANY Phone: +49-1805-3 72 34 37 Fax: +49-451-882-37 79 E-mail: cod@draeger.com Latin America / Iberian Peninsula: Dräger Medical Hispania S.A. c/ Xaudaró n 5 28034 Madrid SPAIN Phone: +34-91-728 34 09 Fax: +34-91-358 51 61 E-mail: latinoamerica@draeger.es Asia / Pacific: Draeger Medical Asia Pacific Ltd. Unit 2205, 22 nd floor Harbour Centre 25 Harbour Road Wanchai HONG KONG Phone: +852-28 77 30 28 Fax: +852-28 77 33 37 E-mail: apinfo@draeger.com.hk www.draeger-medical.com 90 97 451 / SD 5664.510 e / 078D Subject to modifications Printed in Germany / chlorinefree - ecological