2 WORD A4 E / 10-10 / C A 8010 GA + Kal / GA Alle Sprachen



Similar documents
2 WORD A4 E / / C A GA + Kal GA Alle Sprachen

AlcoQuant Breathalyser Operating instructions

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

User Guide. Temperature and Humidity Datalogger. Model 42280

EasyStart R + Operating instructions. Comfort radio remote control with integrated timer for parking heaters and more.

Runtastic rechargeable battery for iphone 4, 4S

DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual English Please read carefully before using this product

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Rousseau 10. User Guide

Controls. Opening the cover

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

G-PORTER. Portable GPS Tracker GP-102 User s Manual

HOFFRICHTER DATA box

Micro HDMI to VGA with Audio Adapter. Quick Installation Guide. Introduction. Key Features and Benefits. System Requirements.

Manual FlashLED Li-Ion. Imprint: GIFAS-ELECTRIC GmbH CH-9424 Rheineck Switzerland Technical changes and errors reserved.

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Nokia Bluetooth Headset BH-800 User Guide Issue 2

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

How To Use A Power Supply Unit (Upu)

FMT600BT Transmitter

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

Instruction Manual FL

Contents. Product Code Page 1

Hygro-Thermometer + InfraRed Thermometer Model RH101

Product Overview. Product Interface

2GB MP3 Player USER GUIDE

XP Series Balances Operation Manual

GSM Alarm System User Manual

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

USB/RS485 converter cable, complete

400 Amp Rechargeable Jump Start System RAC-HP082

Dräger Alcotest 9510 Evidential Alcohol Measuring Device

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

evohome Wireless Radiator Zoning Kit Installation & User Guide

Starter-Kit. Operating Instructions

Hand-held thermometer Model CTH7000

DAB & FM RADIO Installation Manual

PortaSens ll G AS DETECTOR

Integrating Sound Level Meter and Datalogger

XPAND (DLP -Link ) 3D Glasses

Single Use USB Data Logger EBI 330-T30 / EBI 330-T85. User Manual

Model: Manual DC: WIRELESS COLOR FORECAST STATION

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

ExStik TM ph Waterproof Meters

Upper Arm Blood Pressure Monitor SC Instructions for use

TT TOYS TOYS - OWNER S MANUAL. We are delighted that you have decided to purchase this TT Toys Toys children s car.

Universal Wireless Effects Controller USER S GUIDE SA115

Your night vision. Operating Instructions CAMERA MODULE. with integral instant recording

Microwave Meter. Instruction Manual

CYMAQ Marking System AS200 + DS7050 N-14

Nokia Bluetooth Headset BH-200 User Guide

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

Mini Digital Altimeter & Climb rate & Barometer & Thermometer & Compass & Weather forecast & Time

SATEX SA Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg DA Zeewolde HOLLAND

EDIC-mini TINY Model SOLAR 1120/2240/4480/8960/17920

Solar Controller / Battery Charger User s Manual

Changers Kalhuohfummi User Manual

Quick Operation Guide DAB, DAB + und DMB USB Digital Receiver Albrecht DR 403

Back-UPS Pro 1300/1500 Installation and Operation

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

ER102. Emergency Crank Weather Radio Owner s Manual.

User Manual. Listen to your favourite songs on the radio on the road & in a car

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

Portable Bluetooth Speaker. Quick Start Guide. Model: BTS201

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

INSTRUCTION MANUAL Contactless Clinical Infrared Thermometer GT-101

Using GIGABYTE Notebook for the First Time

A-Series Data Loggers PRODUCT MANUAL

AudioJoG (TM) Pro 8 Connector PIN LABEL LED Connector PIN LABEL LED. Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks

Nokia Bluetooth Headset BH-102. Issue 1

Nokia Wireless Keyboard (SU-8W) User Guide

Dual Laser InfraRed (IR) Thermometer with Color Alert

e I N S T RUC TION M ANU A L

COLOR TFT LCD MONITOR. User Manual

August International Ltd United Kingdom Telephone: +44 (0)

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Advanced Systems Tester 900AST

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

VIVA 4G LTE Mini Router. Quick Start Guide

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Stove Guard Kit User Manual

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Mini Video Speaker. Model: MVS01. User s Manual

digital fever alert ear thermometer suitable from birth instruction manual

USB Scrolling Optical Mini Mouse

Lockout Specification BW Clip Maintenance-free single gas detector

USER MANUAL. 2. Get started 2.1 Overview The headset contains the following parts as shown in the figure:

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

User's Guide. Pinless Moisture Meter. Model MO257

Getting started with

Basestation with icom. User Guide

Using GIGABYTE Notebook for the First Time

1. SAFETY INFORMATION

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI

Point of view HDMI Smart TV dongle Mini RF Keyboard

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Instruction Manual Temp 4/5/6 Temperature Meter Series

Vectron POS Mini II. User manual

Dual Laser InfraRed (IR) Thermometer

Table of Contents Function Keys of Your RF Remote Control Quick Setup Guide Advanced Features Setup Troubleshooting

Transcription:

2 WORD A4 E / 10-10 / C A 8010 GA + Kal / GA Alle Sprachen

Table of contents The device... 3 Scope of delivery... 4 Important information... 4 The measuring method... 4 CA 8010 Operation... 5 Inserting the rechargeable battery (Akku)... 5 Loading the rechargeable battery... 5 Switch on the device... 5 Performing a measurement... 6 Indicate measuring results... 7 Time adjustment... 7 Calibration the AlcoConnect 8010... 7 Switch on the device... 8 Calibration mode... 8 Settings... 8 Country code:... 8 Measuring unit... 8 Alert level:... 8 Calibration... 9 Order information for the CA 8010... 9 Troubleshooting... 10 For your safety... 10 Safety information... 11 Cleaning... 11 Technical information... 11 These instructions have been prepared with the greatest of care should you however, when working, find details which do not agree with the system, we would ask that you please inform us briefly so that we can correct the inconsistencies as quickly as possible. - 2 -

The device Congratulations on the purchase of this new hand-held alcohol breathalyser. The CA 8010 fulfills almost every demand that can be put to a small and still very economic device. 1. Large colour screen in a blue tint with time, battery state and accurately measuring data display 2. Memory for 199 measurements 3. Measuring result in 4. Simple and fast calibration can also be performed by the client himself. To do that Cosmos provides 1 mobile devices (Gas simulator) For further information please ask for an offer with calibration manual! 5. Calibration and final testing of every device before shipping. 1. Mouthpiece nozzle 2. Time, date, measuring result 3. Seconds ( Time ) 4. LCD display 5. Battery indicator 6. Menu up or + 7. Menu down or - 8. USB interface 9. Mode button 10. OK button 11. Power button and menu return 3 1 5 6 7 2 4 10 9 8 11-3 -

Scope of delivery This ist the condition you will find your CA 8010 in at the time of purchase. The device is calibrated and after loading the rechargeable battery ready for use. Shipment in a stable plastic case with detailed instruction for use COSMOS breathalyzer CA 8010 Belt pouch with zipper 3 mouthpieces with back flow 1x rechargeable battery ( before first use, please load the battery ) USB charging cable Car adaptor Hand strap Guarantee for the sensor 6 month ( consumable ) Guarantee for the device 24 month ( subject to proper use ) Unlimited right to return within 2 weeks of delivery Important information Threshold limits for impaired driving incapacity vary from country to country. Independent of this, because of different tolerances to alcohol, a blood alcohol concentration of lower than 0.2 0.4 for example can also impair driving and lead to criminal culpability. In Germany, criminal prosecution and a fine can be expected if neurological impairment is 0.30 or above. A test with the CA 8010 will not be accepted by the police as evidence, it is nevertheless an important indicator for you to act responsibly. The COSMOS- ALCOHOL-TESTER was calibrated before shipment. To ensure continued correct measurement results, it should be recalibrated every 6 months. To do this, please send the device to you supplier. The measuring method Blood and breath alcohol are closely connected. Deep in the lungs, in the alveoli, blood and breathed air are separated by a thin gas permeable membrane. The gas exchange takes place here. Oxygen passes to the blood and carbon dioxide, and any alcohol, passes to the breathed air. In order to get this air out of the depth of the lungs (alveolar air) for analysis, a sufficient minimum volume of breathed air must be breathed out. Only if a sufficient volume of breathed air is breathed out and this is blown with enough strength for at least 4 seconds will a correct measurement be achieved. - 4 -

CA 8010 Operation Inserting the rechargeable battery (Akku) Open the battery cover at the backside of the CA 8010. Insert the rechargeable battery. This is also the place of the buffer-battery for the CA 8010. The guarantee expires if the label removed. The backup (buffer) battery ensures that the functionality of the memory and time is maintained in the case of the rechargeable battery runs low. Buffer battery Loading the rechargeable battery Please connect the CA 8010 to the supplied USB cable and a free USB port on your PC, Notebook or car adapter for loading. The battery-status- indication on the display shows the loading procedure by the three moving bars. If the bars comes to a standstill the rechargeable battery is fully charged. Switch on the device Briefly press the power button to switch on the CA 8010. This is confirmed by an audible signal and the display shows the current time. - 5 -

Performing a measurement Attention: The test person may not have drunk alcohol within 20 minutes before giving a breath sample. Otherwise, a false, elevated value will show. For hygienic reasons and to prevent excessive moistening of the sensor, please use a new mouth piece for every measurement ( otherwise a complete malfunction of the sensor could result ). Smoke also damages the sensor. Do not smoke 5 minutes before a test! 1. Switch on the CA 8010 by press briefly the power button 2. By pressing the OK button for more than one second the display shows PH. Now the sensor is pre-hated. 3. Please place the mouth piece in the mouth piece nozzle. 4. If READY and BLOW will flash alternately you have 30 seconds to start a measurement. 5. Now please breathe into the mouthpiece with a sufficiently large respiratory flow, evenly and without interruptions. A proper blow-in procedure is indicated by an audible signal. 6. These breath sample are evaluated and outputted as a measurement result. The display shows AnlY und and then the measuring result. - 6 -

Indicate measuring results 1. Switch on the CA 8010 by pressing the power button. 2. Press briefly the Mode button. 3. Press the lateral up- and down key for display the measuring results. 4. By pressing the Power button you will return to the time. 199 measuring results will be stored, if the memory is full the oldest result is automatically deleted. measuring result up measuring result down Time and date adjustment Please press the lateral down key for 3 seconds. The second-indication of the actual time begins to flash. By pressing the up (6) key again single values can be changed. By pressing the mode button you switch to seconds minutes hours year month day. Finally press the power button (11). - 7 -

Calibration the AlcoConnect 8010 Switch on the device Press briefly the power button to switch on the CA 8010. This is confirmed by an audible signal and the display shows the current time. Calibration mode Aktivate the calibration mode by pressing the central lateral keys between 6 and 7 + OK-button (10) at the same time. The display shows 0 0 0 0, and the first two digits start flashing. Replace the two flashing 00 with the number 20 by pressing the + key and confirm with OK. Now the third and fourth 00 flashes. Replace these two 00 with the number 10 by pressing the + key.! Please do not press the OK button or any other key. After a few seconds the device switches automatically into the calibration mode. Settings Factory pre-set for germany (21) in and alert 0,50 Country code: You can change the country code by pressing the + button. Number 20 Switzerland Number 21 Germany Number 23 England Measuring unit: You can change the measuring unit by pressing the OK button.. % mg/l Alert level: You can change the alert level by pressing the - button. 0,20 0,30 0,50 0,80-8 -

Calibration Once you have made the settings you require, and when no key is pressed for a short time the display shows SH 99. After the heating-up phase of the sensor the display shows BLOW. You are now ready to begin with gassing the sensor. 1. Run: In the first step you gasing the sensor with a calibration solution of 0,20. Please confirm the measuring result which is indicated by pressing the OK button. 2. Run: Start the second run by pressing the OK button. The display shows again SH 99, the sensor heats up and the display shows again BLOW. Now you start with the second gassing by using a calibration solution of 1,00. Please also confirm the second measuring result and finalise the calibration procedure by pressing the OK button. After the completetion of this works the CA 8010 is ready for operation for the next 6 month. Order information for the CA 8010 Product Number Item no. Price* Breathalyzer CA 8010 black Shipment in a aluminium case, with accessories comprising: 25 mouthpieces, batteries, belt pouch, instruction manual 1. piece 8010 Mouth pieces with rebreathing inhibitor 1 VE = 25 St. einzeln verpackt Belt pouch For the convenient storage of the device and mouth pieces Transport- and storage case USB jack For the connection of the Alco Conect 8010 to a PC or Laptop 1. piece 0023 1. piece 7202 1. piece 1. piece Gas simulator exclusiv Complete with thermostat for constant temp. 34 C, air pump for calibration, flow meter with control and automatic air-flow stop. Calibration-alcohol-solution for Cosmos Gas simulators 500 ml with 0,20 + 1,00 1 piece 0403 1 bottle 0404 * VAT to be added to all prices plus shipping costs, if necessary. Subject to change. - 9 -

Troubleshooting Fault description The device does not turn on Device turns off Measuring data gets lost Err Fault / remedy - Please reload the rechargeable battery by using the USB loading cable Please check the state of charge of the battery. (Image 1 Pos. 5) Batterie + -Buffer battery is weak Send the device to the supplier for repair. Blown too weak or too short Please contact Cosmos Service if the faults cannot be corrected! Caution: Used alkali batteries - do not throw into fire - do not charge batteries. Risk of explosion! - do not use force to open. Risk of explosion! Only dispose of as toxic waste. Comply with local regulations governing disposal. For your safety Please observe the instruction manual exactly and use the device only for the purpose described. As accessories, please only use original parts listed in the spare parts list on page 15. Repairs may only be carried out by specialists. ( Cosmos Service ). Maintenance intervals must be complied with. Liability for the function of the devices transfers to the owner or operator if the maintenance is not performed by Cosmos Service. The manufacturer s warranty conditions apply. - 10 -

Safety information The device is only designed as an alcohol breathalyzer and may only be used for this purpose. Batteries may not be charged or reactivated and must be kept away from children. Medical attention must be sought immediately if a battery is swallowed. Only dispose of batteries at official or retail collection points. If you no longer want the device, please send it to your supplier. The supplier will ensure for proper recycling/disposal. Cleaning Only with a soft, dry cloth. Do not use cleaning agents. Technical information Display: Digital LCD display with backlight Dimensions: W x L x D 54 x 114 x 18,5 mm Weight: approx. 75 g without battery Batteries: 3,7 volt lithium Measurement method: electrochemical sensor ( fuel cell ) Precision: 0,05 at 0.50 Measurement range: 0.10 to 4.00 (0.05 to 2,00 mg/l) Temperature range: 5 C bis +50 C Shutdown: automatic after 30 seconds The CA 8010 should be recalibrated every 6 months. We reserve the right to make necessary technical and optical modifications and improvements without serving notice. Electrical and Electronic Equipement Act ElektroG dated 16/03/05 Manufacturers and importers of these kinds of devices are required to dispose of them properly in accordance with statutory provisions. This alcohol breathalyzer is a device subject above all to the provisions under 2/8 and 9 of this law for wich there is no requirement to make disposal at a public disposal site. Your supplier would like however to comply with any future ordinances. Should you no longer use the device we hope after many years of faithful serve please return it to us so that we can dispose it properly for you. Thank you. Attachment / RoHS - 11 -

EG - KONFORMITÄTSERKLÄRUNG EC - DECLARATION OF CONFORMITY For the following device: Name: COSMOS-ALCOHOL-TESTER Model: C A 8010 Serial no.: 00100-02000 We confirm herewith that the design of the above named device conforms with applicable EC guidelines. The declaration loses its validity if changes are made without authorisation from us. Applicable EC guidelines:: Emissions Radiated emission Interference immunity Electrostatic discharge Electromagnetic field Magnetic field (power-frequency) EN55022 EN61326-1 EN61326-1 EN61326-1 Design model test: We confirm that our design model conforms with the requirements of the EC guidelines above. Bad Segeberg 01.06.2010 COSMOS-ALKOHOLTESTER GmbH Onno Lüttmer Cosmos-Alkoholtester GmbH Am Ihlsee 18, D-23795 Bad Segeberg E-Mail: cosmos@alcoholtester.de Tel.: +49-(0)-4551-83838 Fax: +49-(0)-4551-87171 - 12 -