MUELLER FALLING FILM CHILLERS



Similar documents
SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

MAC-120HE-01 Air-Cooled Chiller

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Defining Quality. Building Comfort. Heating and Cooling Coils

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

SECTION HEAT PUMPS

FLASH TANK ECONOMIZER PRODUCT GUIDE

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Mechanical Rooftop Custom Capabilities

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Using Portable Spot Air Conditioners in Industrial Applications

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

How To Use A Water Source Heat Pump

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Attachment J-C18.1. HVAC Work Instructions

Technical data. Danfoss DHP-A

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

How To Understand Evaporator

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

VACUUM REFRIGERATION SYSTEMS

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

DESIGN STANDARDS SECTION

Packaged Glycol Chiller Systems Operation Manual

Air Eliminators and Combination Air Eliminators Strainers

CEILING CASSETTE FAN COIL UNIT

How To Clean Water From An Ammonia Refrigeration System

HL Series - Commercial Heaters Tankless Water Heating Solutions

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Legacy Chiller Systems, Inc

Select Radiators Installation Guide

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance ( scfm models)

Light Duty Commercial Electric Water Heater

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

ASME Packaged Indirect Fired Water Heater

Medical Air Systems: Scroll

Morrison Bros. Co. General Product Specifications

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

NSN

Nirvana. Cycling Refrigerated Dryers

Product Data. Features/Benefits. AquaForce 30XA Air-Cooled Liquid Chillers. 80 to 500 Nominal Tons (265 to 1740 Nominal kw)

Rental Services Temporary Cooling - Flexible Water Hose

SECTION MORTUARY REFRIGERATORS

ice 3 FLUID TO FLUID HEAT PUMP

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

RPV - RP - RA air handling units

Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities.

Chilled Water HVAC Systems

Glossary of Heating, Ventilation and Air Conditioning Terms

Model 1210C Battery Powered Pump Shown. Description

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

Packaged Terminal Air Conditioner Wall Sleeve Installation

Cool Design for Homes and Offices

SECTION Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

Installer s Guide 18-AH39D1-13

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

Steam System Best Practices Condensate System Piping

HVAC Preventative Maintenance Basics. Presented by Mike Crawley

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

SECTION AIR CONDITIONING UNIT

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

Refrigeration and air-conditioning. Alfa Laval s offering at a glance

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

INSTALLATION AND SERVICE MANUAL

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

Commissioning - Construction Documents (Page 1 of 6)

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

PBM has solutions for your valve application.

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

MDT5N25 & MTD5N40 SERVICE PARTS

V47 Series Temperature Actuated Modulating Water Valves

REFRIGERATED COMPRESSED AIR DRYERS

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Commercial Gas Water Heaters

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

A. Section includes air conditioning units, controls and control panels.

Ceiling Mount Air Handler Manual

Installation Manual CLIFC Fan & Coil Variable Speed

AABC Specifications for Testing and Balancing HVAC Systems

HOSHIZAKI AMERICA, INC.

ARMSTRONG AIR HEAT PUMPS

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Transcription:

MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Mueller s falling film chiller is to cool food-grade liquids that will become an ingredient in a food product, or that will come into contact with a food product. Other applications include cooling fluids that have an initial temperature of more than 80 F. This task cannot be accomplished in most conventional chillers. REFRIGERATION PRODUCTS

The Chilling Solution To qualify as a food-grade chiller, the chiller must meet USDA and FDA requirements. The following are a few important issues to consider: An acceptable material for construction must be chosen. All product contact surfaces shall be visible for inspection. All product contact surfaces shall be smooth and free of pits, crevices, and scale. The product zone shall be free of recesses, open seams, and gaps. All internal corners or angles in the product zone shall have a smooth and continuous radius of 1 /4" or greater. Equipment shall be capable of draining all of the fluid it holds. Gaskets and O-rings must be made of approved food-grade material. The falling film chiller was designed to meet all of these requirements and provide you with the chilling solution to all your chilling requirements. 1 1-800-MUELLER www.muel.com

Chiller Components Cabinet Cabinets are available in designs to meet your specific chilling requirements. Standard units are built to accommodate the following: (8) 3 x 5 plates or (8, 16, 24, and 32) 4 x 8 plates. Construction Features Standard units are constructed of Type 304 stainless steel with a 2B finish. All welds are blasted with glass beads. Optional materials are available upon request, including 316L and AL6XN, as well as others. Optional finishes include No. 4 food-grade finish and electropolish for ultra-high purity or corrosive applications, as well as others. Evaporator The evaporator allows water to be chilled as low as 34 F and other solutions to within one or two degrees of their freeze points with no freeze-up problems or chiller damage. Multi-size evaporators are available to meet specific load requirements (3 x 5 and 4 x 8). Evaporator plates are circuited to maintain proper oil return and ensure maximum refrigeration efficiency. The system is suitable for use with R-22, R-404A, R-134A, and ammonia refrigerants as well as most new non-cfc refrigerant products in flooded, recirculated, or directexpansion systems. Built to ASHRAE 15 standards, the system is rated at 300 psi at 400 F. Optional ASME code-stamped evaporators are available. Fill Connection Chillers are equipped with a threaded fill connection which allows for the use of electronic level controls. The fill connection is located on the water pan inlet. Optional Refrigeration Manifolding Optional manifolding is available for all types of refrigerants. When direct expansion refrigeration systems are used, manifolding includes the mounting of required expansion valves. Copper or stainless steel would be the ideal material to choose. Overflow Connections All chillers are equipped with a female, threaded overflow connection, which allows for simple piping of excess fluid. Tank Reservoir Standard tank sizes are available from 190 to 1,400 gallons. The holding tank is insulated with a minimum of 2-inch insulation for elimination of heat loss and condensation buildup. A sloped bottom allows for complete drainage of the holding tank. Adjustable legs enable the chiller to sit level on uneven surfaces for proper operation of the distribution pan and allow an even laminar flow pattern over the evaporator plates for maximum cooling efficiency. Water Distribution Pan The distribution pan has holes over each vertical evaporator plate to allow a thin, uniform solution to flow over both sides of each plate. The hole size and spacing are determined by the flow rate requirements for each chilling application. Pans are available in extra low, low, and high flow. Minimum flow is 1.2 gpm per linear foot of plate with a maximum flow rate of 6.2 gpm per linear foot of plate. Mueller Refrigeration Products 2

Features and Benefits Standard Option Concept The falling film chiller product was designed around the standard option concept to enable us to improve quotation lead time, delivery time, and lower cost. This concept has allowed us to pre-design the entire product line once, which eliminates the unnecessary cost of re-engineering a custom product for each order. By taking the time to evaluate the needs of all of our different customers, we were able to design all of the needed options. This also makes it unnecessary for our customers to pay for something on their chiller they do not need. These two advantages provide you with the lowest cost and the shortest lead time in the industry. Cabinet Sizes We currently build two chiller sizes, 3 x 5 and 4 x 8. The 3 x 5 chiller is available in an 8-plate cabinet. The 4 x 8 chiller is available in an 8-, 16-, 24-, and 32-plate cabinet. Each of these chillers has a tank that was properly sized to satisfy the requirements of the chiller. We also offer a tankless chiller cabinet in the following sizes: 8-plate 3 x 5, 8-plate 4 x 8, 16-plate 4 x 8, and 24-plate 4 x 8. Cabinet Top Options Each cabinet is available with a welded in place top or a top fitted with a hinged door over each distribution pan. The above options allow for access (or not) to the top of the chiller, depending upon your needs. Cabinet Expandability Adding additional plates (up to cabinet capacity) is nearly effortless due to the advanced cabinet design of all of our chillers. So, be sure to select a cabinet that allows for future expansion when you are ready to buy your next chiller. When expansion time comes, you will only have the cost of additional plates and distribution pans, not a second chiller which requires an expensive installation. Evaporator Features and Options We offer 3 x 5 and 4 x 8 plate sizes. Each plate size is available for DX, recirculated, and flooded refrigerant controls for R-717, R-22, R-404A, and all other conventional refrigerants. Due to the plate design, no special refrigerant controls are necessary, nor are you forced to select flooded controls when DX would be less expensive and a better fit for your application. All plates are built to ASHRAE 15 standards rated at 300 psi at 400 F. Optional ASME plates at the same rating are available. Evaporator Internal Plate Capacity Mueller s patented Temp-Plate is the most efficient falling film chiller evaporator available today. Each evaporator is designed to use the smallest refrigerant charge possible and is circuited to ensure that the entire evaporator operates at the correct temperature. The internal volume is.15 cubic feet for the 3 x 5 plate and.42 cubic feet for the 4 x 8 plate. These capacities are 8 to 10 times less than others. Tank Connection Options Each chiller is laid out with multiple locations for tank connections. This option allows you to pick the location and any standard size connection for your chiller. You can select the connection size and location from our list of standard connections located on the submittal drawing for each cabinet. Refrigerant Controls We provide DX and flooded refrigerant controls for all refrigerants. For details on the individual components, review the Falling Film Chiller Operations and Installation Manual. 3 1-800-MUELLER www.muel.com

Water Level Control Option All Mueller falling film chillers are equipped with a 1 /4" connection to allow for the installation of an optional water level control. This control will allow you to set the upper and lower level anywhere you choose. There are three optional control panels which allow you to set the level control. The three components needed to operate the level control are the pressure transducer, a 1" water solenoid valve, and one of the optional control panels described in the Control Panel Options section. Control Panel Options We offer three standard control panels. The following is a brief description of each panel. Model 100 Control Panel The Mueller Model 100 chiller control is designed to control chiller water temperature. It requires 230/60/1 electrical input. Outputs to control temperature are 24-volt to operate a refrigeration unit, chiller circulation pump, process circulation pump, and optional water level control and fill solenoid valve. Model 200 Control Panel The Mueller Model 200 chiller control is designed to control chilled water temperature. The chiller control will accommodate 208/60/3, 230/60/3, or 460/60/3 electrical input. Outputs to control temperature are 24-volt and can operate up to four stages of refrigeration. It will also control the operation of a chiller circulation pump (up to 5 hp), a process circulation pump (up to 5 hp), and optional water level control and fill solenoid valve. Refrigeration Units We offer a complete line of condensing units that have been designed to match the performance requirements of the falling film chiller. These units are available in outdoor air-cooled, water-cooled, and remote aircooled (with outdoor) condensers. Each type of unit is available in horsepower sizes from 5 to 120 hp. Some sizes may not be available in all types. Specially Designed High Sides Custom high sides of all sizes and configurations are available upon request. Quotation Lead Time For quotations on chillers with standard options, the normal lead time is 24 hours or less from the time we receive your request. Requests for quotes that include no standard options may take longer. Order Lead Time The normal shipment lead time after the receipt of an order is four weeks. Some orders with special requirements may take up to two weeks longer. Quality, price, and service Mueller provides all three! Level Control Panel This board is mounted in the 6" x 6" level control box and can be used to set up the reservoir level to control the water fill valve. Mueller Refrigeration Products 4

Options, Accessories, & Other Equipment Refrigerant Controls Refrigerant controls for ammonia and other refrigerant including direct expansion, flooded, and recirculated systems are available. Refrigerant Circuit Manifolds Refrigerant circuit manifolds are available to simplify installation. Manifolds for DX systems include valves and external equalizers already mounted. Flooded and recirculated manifold are available in copper and stainless steel materials. Additional Equipment Surge drums, receivers, hand valves, and other refrigerant accessories are available upon request. Temperature Control Assemblies Temperature control packages are available to control temperature, circulating pumps, and make-up water levels. Pumps Circulating pumps are available in various flow ranges and materials to suit your needs. Condensing Units Condensing units (semi-hermetic and scroll compressors) are available in air-cooled, remote aircooled, or water-cooled models. 5 1-800-MUELLER www.muel.com

3 x 5 Chillers The Mueller 3 x 5 falling film chiller reduces chilling time, increases production, and brings a faster return on your investment. The Mueller 3 x 5 falling film chiller is designed with a fully welded cabinet which includes a hinged and gasketed door for access. Built for lower-capacity applications, the unit is equipped with a 190- or 400-gallon self-contained storage tank. Distribution pans are available with extra-low, low, and high flow rates, based on chilled water usage. Extra-low flow rates range from 4 to 10 gpm, low flow rates range from 8 to 15 gpm, and high flow rates range from 16 to 30 gpm (per evaporator). 3 X 5 CHILLER SIZING CHART No. of Plates Dimensions Maximum Shipping Tank Capacity Distribution Pan Cabinet Size Minimum Maximum L x W x H (in) Weight (lbs) (gal) Connection Size N 2 8 68 1 /2 x 36 1 /2 x 77 3 /4 1,820 190 2" or 3" O 2 8 68 1 /2 x 36 1 /2 x 97 3 /4 2,020 400 2" or 3" Notes: Refrigerant inlet connection size per plate is 1 1 /8" tube and the outlet size is 1 1 /2" tube. Maximum weight is based on the maximum number of plates that a chiller will hold being in the chiller. Low flow/extra-low flow distribution pan connection is 2". High flow distribution pan connection is 3". Mueller Refrigeration Products 6

4 x 8 Chillers Fully enclosed design eliminates product contamination. The Mueller 4 x 8 enclosed-type falling film chiller is fully enclosed to ensure your product is free from airborne particles. The unit is easily accessible through gasketed doors and is designed for large-capacity chilling applications. Distribution pans are available in extra-low, low, and high flow rates, based on chilled water usage. Extra-low flow rates range from 6 to 16 gpm, low flow rates range from 13 to 24 gpm, and high flow rates range from 25 to 48 gpm (per evaporator). 4 X 8 CHILLER SIZING CHART No. of Plates Dimensions Maximum Shipping Tank Capacity Distribution Pan Cabinet Size Minimum Maximum L x W x H (in) Weight (lbs) (gal) Connection Size J 2 8 104 1 /2 x 39 1 /8 x 90 3 /4 2,735 361 4" or 6" K 2 16 104 1 /2 x 72 3 /8 x 90 3 /4 5,220 706 (2) 4" or 6" L 2 24 104 1 /2 x 105 7 /8 x 90 3 /4 7,705 1,052 (3) 4" or 6" M 2 32 104 1 /2 x 139 x 90 3 /4 10,190 1,397 (4) 4" or 6" Notes: Refrigerant inlet connection size per plate is 1 1 /8" tube and the outlet size is 2" pipe. Maximum weight is based on the maximum number of plates that a chiller will hold being in the chiller. Low flow and extra-low flow distribution pans have a 4" connection and high flow pans have a 6" connection. 7 1-800-MUELLER www.muel.com

4 x 8 Chillers Back View (left) Gasketed door with latches make the chiller easily accessible for inspection and servicing. Outlet connections are available in various sizes and piping configurations. Top View Optional top doors are available for accessibility to the distribution pan for needed cleaning. Inlet Connection Inlet connection is shown here with optional make-up water valve. Overflow Connection Each chiller has an overflow connection to guard against over filling the reservoir. Water Level Control Optional water level sensor is available if needed. Mueller Refrigeration Products 8

Tankless Chillers Versatility to match your specific storage needs. Mueller s tankless chiller is designed for applications where it is necessary to place the chiller over the top of an existing tank. Distribution pans are available in extra-low, low, and high flow. Units are available in both 3 x 5 and 4 x 8 evaporators from 8- to 24-plate cabinets. TANKLESS CHILLER SIZING CHART Cabinet L x W x H Weight with Refrigeration Connection Size Water Pan Size (in) Plates (lbs) Inlet* Outlet* Connection Size 8-3 x 5 70 x 43 x 48 990 1 1 /8" Tube 1 1 /2" Tube 2" or 3" MPT 8-4 x 8 108 x 43 x 62 1,550 1 1 /8" Tube 2" Pipe 4" or 6" MPT 16-4 x 8 108 x 67 x 62 2,980 1 1 /8" Tube 2" Pipe (2) 4" or 6" MPT 24-4 x 8 108 x 104 x 62 4,220 1 1 /8" Tube 2" Pipe (3) 4" or 6" MPT Note: *Inlet and outlet connection sizes are per plate connection sizes. 9 1-800-MUELLER www.muel.com

Falling Film Chiller Model No. Breakdown Plate Sizes Sanitary/ Non-Sanitary No. of Plates Cabinet/Plate Material N = 3 x 5 1 = Sealed Edge 3 x 5 = 2-12 1 = 304 / 304 L = 4 x 8 2 = Non-Sealed Edge 4 x 8 = 2-36 2 = 304 / 316L 3 = 316L / 316L 4 = 304 / 304EP Cabinet Models I = Tankless J = 361 4 x 8 2-8 ASME/Non-ASME A = ASME N = Non-ASME 5 = 304 / 316L EP 6 = 316L / 316L EP 7 = Other K = 652 4 x 8 9-16 L = 943 4 x 8 17-24 M = 1234 4 x 8 25-32 N = 190 3 x 5 2-8 O = 400 3 x 5 2-8 Refrigeration Control Type A = R-22 DX B = R-404A & R-507A DX Manifold 1 = Yes 2 = No C = R-134A DX D = R-717 DX E = R-22 Flooded F = R-404A & R-507A Flooded G = R-134A Flooded H = R-717 Flooded I = R-22 Recirc J - R-404A & R-507 Recirc K = R-134A Recirc L = R-717 Recirc M = Glycol N = Other Pan Type 1 = High Flow 2 = Low Flow 3 = Extra-Low Flow PP.O. Box 828 Springfield, Missouri 65801-0828, U.S.A. Phone: (417) 831-3000 1-800-MUELLER Fax: 1-800-436-2466 www.muel.com E-mail: refrigeration@muel.com 1998-2005 Paul Mueller Company CR-1225-5