SERVICE PARTS INSTRUCTIONS



Similar documents
System Saver Series Single Cartridge Air Dryers

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

Air Dryer Application Guidelines

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work

Electronically Controlled Air Suspension (ECAS) for Trucks

Meritor WABCO Hydraulic Power Brake (HPB) System Bleeding Procedures

Filters Air Dryers 08

Class 5 to 7 Truck and Bus Hydraulic Brake System

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

L /96. Haldex INSTALLATION INSTRUCTIONS HALDEX PURE AIR PLUS EXTENDED PURGE KIT (DQ6027) HEAVY DUTY CANISTER KIT (DQ6028)

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

DiscPlus DX195 and DX225 Air Disc Brakes

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Compressor Service & Maintenance Manual

NITROUS TRANSFER PUMP INSTRUCTIONS

SELF-STEERING AXLE TABLE OF CONTENTS

Cooling Systems. Table of Contents

XL PREMIUM OIL COOLER KIT

Your safety and the safety of others are very important.

Technical Guide 08/15/14

Section 6 Brake Drum Failure Analysis. Brake Drum Wear Conditions. What is Normal Wear? What is Deep or Excessive Wear? WARNING. Deep, Uniform Wear

Oil and Coolant Circulating Heating System. Model - OCSM

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

EZ-Steer Assisted Steering System

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Portable Air Conditioner

accidents which arise due to nonobservance and the safety information herein.

COOLING SYSTEM Section Page

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions

11101, & INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

VOYAGER 570G. 744A Sprayer Control

Before installation it is important to know what parts you have and what the capabilities of these parts are.

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

INSTALLATION MANUAL MODEL RP-100

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

Thermo Top - Troubleshooting Tree

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

13. REAR WHEEL/BRAKE/SUSPENSION

- power windows - alarm system - electric door mirror control - door warning light - central locking - seat memory

Hydraulic Trouble Shooting

MODEL G300 BRAKE BLEEDER

Chapter 7 Hydraulic System Troubleshooting

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Cooling system components, removing and installing

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

Technician High Pressure Pump Guide for the 7.3 Power Stroke Engine

with installation dynafact boost GAUGE this manual is for use with systems

National- Spencer Inc.

CLEAN AND CLEAR PLUS CARTRIDGE FILTER

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

Hydraulic Power Brake (HPB) Catalog

Stainless Steel Single and Dual Circulation Kits

15GAL STEEL OIL DRAIN WITH 110V PUMP

INSTALLATION MANUAL MODEL RP-150

CARING FOR YOUR WATER HEATER

Unit: mm(in) Item Standard value Service limit Axle shaft run out - 0.2(0.008)

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA

INSTALLATION & OPERATING INSTRUCTIONS

WARNING WARNING TABLE 1.

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

How To Fix A Car With A Carbide Engine

Procedures and Intervals to Inspect the Wheel Ends and Tighten the Spindle Nuts on Meritor TL Series Trailer Axles with Unitized Wheel Ends

QT Residential Blower Metal Residential Blower

STEERING SYSTEM - POWER

Select Radiators Installation Guide

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

Unit 24: Applications of Pneumatics and Hydraulics

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

Float and Thermostatic Traps Series H, C and X

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

CHAPTER 11 HEATING, VENTILATION AND AIR CONDITIONING. Section Title Page

SELECTION, APPLICATION AND MAINTENANCE

REMOVAL AND INSTALLATION

CHROME FRONT BRAKE MASTER CYLINDER KIT

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Subject: Pre-Formed and Pre-Flared Hydraulic Brake Pipe Kits Now Available for Service

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Section 7 Adjustment, Repair and Replacement

Table Z. Troubleshooting Chart for Air Conditioners. Cause

ENGINE COOLING SYSTEM

INSTALLATION INSTRUCTIONS

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

1998½-2007 Dodge Ram 5.9L Cummins

PC1130 Electric Air Compressor

OPERATING INSTRUCTIONS AND PARTS LIST FOR U U UNDERGROUND HOSE REELS

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013


SERVICE GUIDE For WARN PULLZALL 120v AC &100v AC P/N &

Water Tec of Tucson Water Systems

NUMBER: 08 DD15-10 S.M. REF.: 3.2 ENGINE: DD15 DATE: September 2008

Transcription:

WACO MERITOR SERVICE PARTS INSTRUCTIONS Installing the Meritor WABCO System Saver 1000 and 1200 Series Air Dryers For Use on Tractors, Trucks and Buses with Air Brakes Installation Requirements 5 P/N 434 100 3100 1 4 2 3 Item Qty. Description 1 1 12- or 24-Volt Air Dryer 2 3 Capscrew (1/2"-13 UNC 2A x 1.375) 3 3 Lock Washer (1/8" thick) 4 1 Heater Power Harness 5 1 Pressure-Controlled Check Valve 16579/Meritor Printed in the USA Copyright Meritor WABCO, 1998 Page 1

Service Notes You must follow your company safety procedures when you install the System Saver 1000 and 1200 Series air dryers. Meritor WABCO uses the following types of notes to give warning of possible safety problems and to give information that will prevent damage to the air dryer. WARNING A warning indicates procedures that must be followed exactly. Serious personal injury can occur if the procedure is not followed. CAUTION A caution indicates procedures that must be followed exactly. If the procedure is not followed, damage to equipment or components can occur. Serious personal injury can also occur in addition to damaged or malfunctioning equipment or components. This symbol is used to indicate fasteners that must be tightened to a specific torque value. A note indicates an operation, procedure or instruction that is important for correct installation. A note can also give information that will make installation quicker and easier. Part Number Selection Guide (See page 3 for application information) Series Voltage (100 Watts) Replacement Kit ID Tag Number 1200 Standard Application 12 volts R955205 432 413 001 0 1200 Standard Application 24 volts R955206 432 413 002 0 1200E Use with Holset E 12 volts R955207 432 413 006 0 Compressor 1200E Use with Holset E 24 volts R955208 432 413 009 0 Compressor 1200U Discharge Line 12 volts R955210 432 413 007 0 (Continuous Flow) Installation 1200U Discharge Line (Continuous Flow) Unloader Installation 24 volts R955211 432 413 021 0 Meritor WABCO System Saver Single Cartridge Air Dryer Publications MM34 PB-96134 TP-9672 TP-9772 TP-97101 T-97105V Maintenance Manual Parts Book Air Dryer Application Guidelines 26 x 40 Troubleshooting Guide Wall Chart Troubleshooting Guide (laminated card) Troubleshooting and Repair Video (30 min.) To order literature contact the Meritor Customer Support Center at 800-535-5560. 16579/Meritor Page 2 Copyright Meritor WABCO, 1998 Printed in the USA

Introduction This installation manual contains basic installation instructions for standard air systems and includes special instructions for installing the Pressure-Controlled Check Valve (PCCV). It also includes System Saver 1000 and 1200 air dryer diagnostics. Read all instructions before proceeding with your installation. Application Information: Cubic Feet per Minute (CFM) Less than 25 CFM Normal Duty Cycle Less than 30% Typical Compressor 2 Minutes or Less Loaded Time WARNINGS To prevent serious eye injury, always wear safe eye protection when you perform vehicle maintenance or service. Do not work around or under the vehicle unless it is parked on a level surface. Use blocks to keep the vehicle from moving. A moving vehicle can cause serious personal injury and damage. Remove all air from the air system before servicing any component in the air system. Pressurized air can cause serious personal injury. Basic Installation Instructions GOVERNOR COMPRESSOR INTAKE LINE UNLOADER PORT GOVERNOR PORT COMPRESSOR DRYER OUTLET COMPRESSOR DISCHARGE LINE DRYER INLET PURGE VALVE CHECK VALVE SYSTEM RESERVOIR TO BRAKE SYSTEM SYSTEM RESERVOIR PRESSURE-CONTROLLED SUPPLY CHECK VALVE (WET) TANK TYPICAL INSTALLATION FOR SYSTEM SAVER 1000 AND 1200 SERIES AIR DRYER 16579/Meritor Printed in the USA Copyright Meritor WABCO, 1998 Page 3

Mounting the Air Dryer 1. Park the vehicle on a level surface, stop the engine, set the parking brake and block the wheels. 2. Drain pressurized air from all reservoirs to 0 psi (0 bar). Open all draincocks to expel collected water. 3. Inspect the vehicle for a suitable mounting location that meets the following criteria. The air dryer will operate most efficiently when you follow these guidelines. a. Mount the air dryer where cool air can flow around it... but not directly in the vehicle wind stream... and at least 12 inches away from any heat source. b. Mount the air dryer LOWER than the compressor so that water in the delivery line flows into the air dryer. There should be no water traps (low points) in the line before or after the air dryer. c. Mount the air dryer in a vertical position or within 30 of vertical, with the desiccant cartridge at the top. d. Allow at least two inches (51 mm) of clearance above the top of the air dryer for servicing the desiccant cartridge. e. Mount the air dryer in a location where it is not subject to direct splash or spray from a wheel. 4. Apply the adhesive-backed template to the selected location. Figure 1. Figure 1 4.125" / 105 mm 2.875" / 73 mm Air Dryer Installation Template 2.063" / 52 mm 16579/Meritor Page 4 Copyright Meritor WABCO, 1998 Printed in the USA

Check the vehicle manufacturer s specifications before drilling into the frame member. 5. Drill 9/16-inch holes at each cross mark. Use a mounting bracket, if necessary. Figure 2 or 3. 6. Mount the air dryer using the capscrews and lock washers provided. 7. Tighten each capscrew to 22-30 lb-ft (30-40 N m). Figure 2 Connecting the Air Lines Use pipe sealant or teflon tape on all air fittings. The reference to nylon tubing throughout this manual refers to SAE J844 air brake nylon tubing. 1. Connect the delivery line from the compressor to the air dryer inlet port (1/2" NPTF, marked 1 ) with 1/2-inch-ID minimum stainless-steel braided teflon hose. The air dryer will operate most efficiently when the following guidelines are used. a. The delivery line should follow a DOWNHILL route to the inlet port (Figure 4), free of kinks and sags, which cause water traps. Figure 4 Figure 3 b. Air temperature entering the dryer should be less than 175 F (79.5 C). The delivery line must be at least 6.0 feet (1.83 m), but most vehicles require a greater length to achieve this condition. c. The delivery line should not exceed 20 feet (6.1 m), or moisture within the line can freeze, blocking air passage. d. Insulate a delivery line with a length of over 10 feet (3.0 m). 16579/Meritor Printed in the USA Copyright Meritor WABCO, 1998 Page 5

2. Connect the air dryer outlet port (1/2-inch NPTF, marked 21 ) to the inlet of the supply (wet) tank with 1/2-inch or 5/8-inch nylon tubing. Figure 5. 3. Connect the air governor unloader port to the air dryer control port (1/4-inch NPTF, marked 4 ) with 1/4-inch or 3/8-inch nylon tubing. Figure 6. 4. Check all fittings for leaks before proceeding. Figure 5 Connecting the Heater The System Saver 1000 and 1200 Series air dryers are available in 12- or 24-volt models; each has a 100-watt heater. Each kit contains a two-wire harness which supplies power to the unit. Be sure to select the correct power source for the air dryer model. Using the wrong voltage can cause malfunction and even damage the unit. Check vehicle manufacturer specifications for exact wiring information. 1. Connect one of the leads to a good vehicle ground. Attach the other lead to a line that is powered with the ignition in the run position, and not powered with the ignition off. A 15-amp fuse is recommended for this line for 12 volts and 7.5 amps for 24 volts. 2. Press the male plug on the end of the power cable into the receptacle on the side of the dryer. Plug must be inserted until the latch snaps over the tab on the mating connector. Figure 7. 3. Insulate and seal all electrical splices and properly secure the harness. Figure 7 Figure 6 16579/Meritor Page 6 Copyright Meritor WABCO, 1998 Printed in the USA

Determine the Correct Pressure-Controlled Check Valve (PCCV) Placement for the System Saver 1000 and 1200 Series Air Dryer The regeneration volume is determined by how much compressed air is pumped through the air dryer during each compressor cycle. The following chart shows the proper sizing of the system and the volume of the reservoirs contributing to the regeneration volume required for a given installation. The reservoirs contributing to regeneration will determine the placement of the PCCV in the system. Since the air dryer will take approximately 10 psi from the contributing reservoirs, the volume for regeneration will be a function of the reservoir sizes. The Total System Size is the sum of all the air tanks to be filled on all vehicles that the compressor will be filling. For instance, if the tractor has a total air system of 6000 in 3 (supply 900 in 3, primary 3200 in 3, secondary 1900 in 3 ) and it pulls a lead single trailer with 1400 in 3, a single axle dolly with 1400 in 3, and a second single axle trailer with 1400 in 3, the total system size is 10,200 in 3. Looking at the chart and finding 10,200 in 3 at the bottom, reading up and over shows the system needs 2856 in 3 of reservoir volume contributing to regeneration. From this volume, 10 psi would be taken for regeneration. In this case, installing the PCCV on the primary tank gives adequate regeneration volume (supply 900 in 3 + primary 3200 in 3 = 4100 in 3 ). Figure 8. Formula for Total System Size Use the formula below to compute total system size. r Total System Size = Sum of all reservoir tanks an air compressor must service in the vehicle s air system. Example: (IN 3 ) r Supply (Wet) Tank 900 Primary Reservoir Tank 3200 Secondary Reservoir Tank 1900 Tractor s Total Air System 6000 (IN 3 ) r Lead Single Axle Trailer 1400 Single Axle Dolly 1400 Second Single Axle Trailer 1400 Total Load Pulled: 4200 r Total Combination Vehicle System Size (IN 3 ) The Air Compressor Must Service 6000 + 4200 = 10,200 Figure 8 5000 Volume of reservoirs contributing to regeneration in 3 4000 3000 2000 1000 0 0 5000 10,000 Total reservoir volume in 3 16579/Meritor Printed in the USA Copyright Meritor WABCO, 1998 Page 7

434 100 MERITOR Installing the Pressure-Controlled Check Valve (PCCV) The pressure-controlled check valve replaces the one-way check valve on either the secondary or primary service reservoir. Use pipe sealant or teflon tape on all air fittings. 1. Identify the appropriate service reservoir (see above) and locate the one-way check valve at the inlet. This reservoir is fed by the supply (wet) tank and typically supplies air to the front brakes and air-operated accessories. For more information about the PCCV, please refer to TP-9672, Air Dryer Application Guidelines. If the one-way check valve is internal or otherwise inaccessible, locate the check valve on the primary reservoir. 2. Remove and discard the one-way check valve from the reservoir. The arrow located on the face plate of the PCCV must point TOWARD the reservoir. Figure 9. 3. Install the pressure-controlled check valve in place of the check valve you discarded. If space is limited, you can use a 45 or 90 pipe fitting. 4. Reconnect the supply line from the supply (wet) tank to the inlet of the PCCV. Reroute or shorten the air hose as necessary. Figure 9 P/N WACO 3100 Check the Vehicle s Air System for an Alcohol Evaporator Typically, an alcohol evaporator will be installed in the line between the air dryer and the supply (wet) tank. Common installations are on the truck s firewall, on a frame rail and behind the cab. However, an alcohol evaporator can also be found at other locations. 1. Check the vehicle s air system to determine if an alcohol evaporator is installed. 2. If an alcohol evaporator is installed in the air system, check for a bypass line connected to the evaporator, as illustrated in Figure 10. Figure 10 LINE TO AIR DRYER BYPASS LINE ALCOHOL EVAPORATOR 1/4" NYLON LINE LINE TO SUPPLY TANK CAUTION If a check valve is installed in the bypass line, the air dryer will not function properly. Damage to the system can result. 3. If a bypass line is connected to the evaporator, check to see if a check valve is installed in the bypass line. If check valve is installed: a. remove the check valve from the bypass line, b. remove the bypass line and c. replace the bypass line with 1/4-inch nylon line. 4. If there is no bypass line installed at the alcohol evaporator, install one using 1/4-inch nylon line. Figure 10. 16579/Meritor Page 8 Copyright Meritor WABCO, 1998 Printed in the USA

Testing the System Saver 1000 and 1200 Series Air Dryers 1. Close the drain cocks on all reservoirs. 2. Start the vehicle. Wait for the air system to reach full operating pressure. 3. If the air dryer exhausts air for 10-20 seconds after the governor cuts out, it is working correctly. 4. Apply vehicle brakes several times until the compressor cuts in. 5. If the air dryer exhausts air for 10-20 seconds after the compressor cuts out, it is working correctly. One of the air pressure gauges on the vehicle instrument panel will decrease by approximately 10 psi when the compressor cuts out and the air dryer purges. This decrease is normal for the System Saver 1000 and 1200 Series air dryers. If the gauge does not decrease, recheck the plumbing to ensure proper placement of the pressure-controlled check valve. Final Checks 1. Start the vehicle. Wait for the air system to reach full operating pressure. When the compressor cuts out, listen to the air dryer. If either of the following conditions exist, refer to Meritor WABCO Maintenance Manual No. 34, System Saver 1000 and 1200 Series Air Dryers. a. The air dryer continues to exhaust air for longer than 30 seconds. b. The air dryer does not exhaust air after initial decompression. 2. Shut engine OFF. Apply a soap solution to each connection that contains pressurized air: a. If soap bubbles do not appear, connections are sealed properly. b. If soap bubbles appear: r Drain all reservoirs. r Remove leaking connection. r Inspect for damaged threads or cracks; replace as necessary. r Apply pipe sealant or teflon tape to the connection. r Repeat process. 16579/Meritor Printed in the USA Copyright Meritor WABCO, 1998 Page 9

16579/Meritor Page 10 Copyright Meritor WABCO, 1998 Printed in the USA

System Saver 1000 and 1200 Series Air Dryers Diagnostics Condition Possible Cause Solution Dryer leaks from purge valve during compressor loaded cycle. The leak may cause excessive compressor cycling or prevent the system from building air pressure. Slight leak from purge valve. After several hours, the supply tank may be empty. Regeneration cycle too long (more than 30 seconds), accompanied by loss of pressure in the supply tank. Regeneration cycle too short (less than 10 seconds). No regeneration cycle. No airflow from purge valve after initial purge blast (dryer decompression). Air dryer purges too often, perhaps as frequently as every 15 seconds, accompanied by excessive cycling of the compressor. Air dryer does not purge when compressor unloads (no blast of air from purge valve). Air flows out of purge valve entire time compressor is unloaded. Purge valve frozen open (cold weather operation). Debris under purge valve seat, such as particles from fittings or air inlet line. Purge valve washer installed upside-down. Wrong air line connected to dryer port 4 (unloader port). Purge valve snap ring not fully seated in groove. Outlet check valve not seating or regeneration valve not shutting off regeneration airflow. Outlet check valve not seating. Regeneration valve not shutting off regeneration airflow. High air system demands during compressor unloaded cycle. Pressure-controlled check valve not installed in system or not working properly. One-way check valve installed in system reservoir instead of, or with, pressure-controlled check valve. Regeneration valve not working. Air governor not working properly. Air dryer not connected to supply tank or connections reversed at dryer. Regeneration valve not working. One-way check valve installed in supply tank. Alcohol evaporator installed between dryer and supply tank. Leak in line between governor and dryer port 4. Leak in line between supply tank and governor. Excessive air system leaks. Excessive air system demands. Outlet check valve not sealing. Regeneration valve not shutting off properly. Air governor has less than 16 psi range. Leaking air compressor unloader(s). Air line between governor and air dryer port 4 kinked or plugged. Purge valve stuck closed. Air governor not working properly. Cut-out pressure never achieved by air compressor. Turbo cut-off valve not sealing. Check heater. Repair/replace if necessary. Make sure governor to dryer port 4 line is free of water/oil. Remove and inspect purge valve and clean water/oil from top of piston. Disassemble and clean purge valve. Remove cartridge and clean dryer sump area. Ensure lip on aluminum washer faces down, away from dryer. Verify correct air line installation and correct as needed. Seat snap ring fully into groove. Remove, inspect, and clean outlet check valve and regeneration valve diaphragm. Replace if worn or damaged. Inspect and replace outlet check valve as needed. Replace regeneration valve. Increase air system capacity or reduce air demands. Check and replace pressure-controlled check valve as needed. Remove one-way check valve. Make sure pressurecontrolled check valve is installed correctly. Remove regeneration valve and clean oil from diaphragm. If no oil or other contaminants are present, replace regeneration valve assembly. Inspect per manufacturer s instructions and repair/ replace as needed. Verify proper dryer installation per system diagram. Replace regeneration valve. Remove one-way check valve. Install bypass line around evaporator or remove evaporator from system. Repair air line. Repair air line. Repair leaks. Increase air system capacity or reduce air demand. Inspect and replace outlet check valve as needed. Replace regeneration valve. Replace air governor. Inspect compressor. Repair/replace per manufacturer s instructions. Repair air line. Replace purge valve. Inspect air governor. Repair/replace per manufacturer s instructions. Check for air leaks in system and repair as needed. If no leaks in system, check compressor output. Repair/replace per manufacturer s instructions. Replace turbo cut-off valve. 16579/Meritor Printed in the USA Copyright Meritor WABCO, 1998 Page 11

System Saver 1000 and 1200 Series Air Dryers Diagnostics (Continued) Condition Possible Cause Solution Rapid spitting of air from purge valve in small amounts. Frequency varies with engine speed. Air leak at turbo cut-off valve vent. Hole burned in piston. Air leak at turbo cut-off valve vent. Air dryer frozen (water collecting in base of dryer is freezing). No air pressure build-up in system. Water in tanks; often following aftermarket installation or when dryer is a replacement for a competitive brand. Water, oil, or sludge in air system tanks. Water in system tanks, everything else checks out okay. Holset E-Type compressor used, but non-1200e dryer installed. Compressor not completely unloading when cut-out pressure is reached. Temperature of air coming into dryer is too high not enough cooling takes place before dryer inlet. Lip seal installed upside-down on piston. Lip must face UP (towards dryer). Valve bore worn excessively. No electrical power to heater connector. Low voltage to heater connector. Heater assembly not working. Wrong voltage air dryer used; i.e., 12-volt air dryer used in a 24-volt system. Air dryer not plumbed correctly (connections reversed). Wrong air line connected to dryer port 4. Air governor not working properly. Air system leaks, such as compressor discharge line, air dryer, reservoirs, brake or suspension valves, etc. Air dryer leaks from purge valve. Pressure-controlled check valve not installed in correct tank or not installed at all. Pressure-controlled check valve properly installed, but one-way check valve not removed. Desiccant contaminated with oil. Holset E-type compressor used, but non-1200e dryer installed. Dryer not suitable for application. Replace air dryer with a System Saver 1200E air dryer. Inspect compressor. Repair/replace per manufacturer s instructions. Move dryer farther from compressor. Add additional compressor discharge line before air dryer. Add cooling coil or heat exchanger before air dryer. : Inlet air temperature must not exceed 175 F. Install lip seal correctly. Inspect valve bore for wear. If a new turbo cut-off valve does not seal in a clean, lubricated bore, replace the air dryer. Check for a blown fuse. Repair heater circuit. : There must be power to the heater connector the entire time the vehicle s ignition is on. Repair cause of low voltage, such as poor electrical ground, bad connections, corroded wire splices, etc. Replace heater assembly. Replace with correct voltage air dryer. Ensure compressor discharge line is plumbed to air dryer port 1, and air dryer port 21 is connected to vehicle s supply tank. Ensure dryer port 4 line is connected to the UNL port of the air governor. Inspect governor per manufacturer s instructions. Repair or replace as needed. Locate leak(s) and repair. See purge valve conditions listed in this chart. Install pressure-controlled check valve in secondary tank. Remove one-way check valve so that only the pressure-controlled check valve is installed between the secondary tank and supply tank. Replace desiccant. Inspect compressor per manufacturer s instructions. Replace air dryer with a System Saver 1200E air dryer. Review application guidelines. For assistance, call Meritor Customer Support Center at 1-800-535-5560. Meritor WABCO Vehicle Control Systems 2135 West Maple Road Troy, MI 48084 U.S.A. 800-535-5560 www.meritorauto.com Information contained in this publication was in effect at the time the publication was approved for printing and is subject to change without notice or liability. Meritor WABCO reserves the right to revise the information presented or discontinue the production of parts described at any time. Copyright 1998 Meritor WABCO All Rights Reserved Printed in the USA Please Recycle 16579/Meritor