Chloride and Salinity

Similar documents
Total Water Hardness

Phosphates (ortho- and total)

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor

Lesson 5: Water Conductivity and Total Dissolved Solids Water Quality Sampling

6 H2O + 6 CO 2 (g) + energy

Appendix C. Vernier Tutorial

Water Hardness. Evaluation copy

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Evaluation copy. Titration of a Diprotic Acid: Identifying an Unknown. Computer

Chem 1B Saddleback College Dr. White 1. Experiment 8 Titration Curve for a Monoprotic Acid

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Dissolved Oxygen Probe (Order Code DO-BTA or DO-DIN)

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

AIRMoN, ph and Conductivity Field Measurement

ph Measurements of Common Substances

Experiment 17: Potentiometric Titration

18 Conductometric Titration

Milwaukee USER MANUAL

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

The Determination of an Equilibrium Constant

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

ION EXCHANGE FOR DUMMIES. An introduction

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide below. HF (aq) + NaOH (aq) H2O (l) + NaF (aq)

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Experiment 4 (Future - Lab needs an unknown)

EXPERIMENT # 3 ELECTROLYTES AND NON-ELECTROLYTES

Salinity Protocol. Welcome Introduction Protocols. Learning Activities Appendix. Purpose To measure the salinity of the water at your hydrology site

Household Acids and Bases

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Osmosis. Evaluation copy

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Evaluation copy. Case File 9. A Killer Cup of Coffee? GlobalTech manager dies

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

The Determination of an Equilibrium Constant

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

Freezing Point Depression: Why Don t Oceans Freeze? Teacher Advanced Version

Acid Base Titrations

Experiment 3 Limiting Reactants

User Guide Dissolved Oxygen Probes

DISSOLVED OXYGEN PROBE

9. Analysis of an Acid-Base Titration Curve: The Gran Plot

ES 106 Laboratory # 3 INTRODUCTION TO OCEANOGRAPHY. Introduction The global ocean covers nearly 75% of Earth s surface and plays a vital role in

Photosynthesis and Respiration

Compact Water Quality Meter B-700 series

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Experiment 6 Coffee-cup Calorimetry

Comparison of the Effects of Increased CO 2 in the Air to Seawater and Distilled Water

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

Neutralizing an Acid and a Base

Experiment 8 - Double Displacement Reactions

LZV585 (B) The 1-cm path is aligned with the arrow on the adapter

Endothermic and Exothermic Reactions. Evaluation copy. Mg(s) + 2 HCl(aq) H 2 (g) + MgCl 2 (aq)

YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen

Electrical Conductivity of Aqueous Solutions

Evaluation copy. Figure 1

Experiment 12- Classification of Matter Experiment

Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy

Trace Dissolved Oxygen Sensor

Measurement by Ion Selective Electrodes

DETERMINATION OF PHOSPHORIC ACID CONTENT IN SOFT DRINKS

Lab 7 Soil ph and Salinity OBJECTIVE INTRODUCTION Soil ph active

FAJANS DETERMINATION OF CHLORIDE

Density and Archimedes Principle

Density and Archimedes Principle

Water Quality Tests Summary

ph: Measurement and Uses

TITRATION CURVES, INDICATORS, AND ACID DISSOCIATION CONSTANTS

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

ph Regulation of Seawater: The Role of Carbonate (CO3) and Bicarbonate (HCO3)

GROUND WATER CONTAMINATION INFORMATION

Solubility Curve of Sugar in Water

Properties of Acids and Bases

Calcium Analysis by EDTA Titration

Mixing Warm and Cold Water

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

Experiment 6 Titration II Acid Dissociation Constant

GENERAL SCIENCE LABORATORY 1110L Lab Experiment 6: Ohm s Law

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Pressure -Temperature Relationship in Gases. Evaluation copy. Figure ml Erlenmeyer flask. Vernier computer interface

Neutralization Reactions. Evaluation copy

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

Hardness - Multivalent metal ions which will form precipitates with soaps. e.g. Ca 2+ + (soap) Ca(soap) 2 (s)

Quaternary Ammonium Compounds DOC

How to prepare your baby s bottle

Determination of a Chemical Formula

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

DISSOLVED OXYGEN METER Model : DO-5509

Chapter 4, Lesson 5: Energy Levels, Electrons, and Ionic Bonding

* Readily available from supermarkets and health food stores minutes (total over 3 to 7 days) SOSE: Investigate Australia s salinity crisis

USEPA Electrode Method Method 8156

LIGHTSTICK KINETICS. INTRODUCTION: General background on rate, activation energy, absolute temperature, and graphing.

Separation by Solvent Extraction

DETERMINING THE MASS OF A COPPER ATOM

Activity P13: Buoyant Force (Force Sensor)

Determining the Identity of an Unknown Weak Acid

Transcription:

INTRODUCTION Chloride Chloride and Chloride, in the form of the Cl ion, is one of the major inorganic anions, or negative ions, in saltwater and freshwater. It originates from the dissociation of salts, such as sodium chloride or calcium chloride, in water. NaCl(s) Na + (aq) + Cl (aq) CaCl 2 (s) Ca 2+ (aq) + 2 Cl (aq) These salts, and their resulting chloride ions, originate from natural minerals, saltwater intrusion into estuaries, and industrial pollution. Sources of Chloride Ions River streambeds with salt-containing minerals Runoff from salted roads Irrigation water returned to streams Mixing of seawater with freshwater Chlorinated drinking water Water softener regeneration There are many possible sources of manmade salts that may contribute to elevated chloride readings. Sodium chloride and calcium chloride, used to salt roads, contribute to elevated chloride levels in streams. Chlorinated drinking water and sodium-chloride water softeners often increase chloride levels in wastewater of a community. In drinking water, the salty taste produced by chloride depends upon the concentration of the chloride ion. Water containing 250 mg/l of chloride may have a detectable salty taste if the chloride came from sodium chloride. The recommended maximum level of chloride in U.S. drinking water is 250 mg/l. is the total of all non-carbonate salts dissolved in water, usually expressed in parts per thousand (1 ppt = 1000 mg/l). Unlike chloride (Cl ) concentration, you can think of salinity as a measure of the total salt concentration, comprised mostly of Na + and Cl ions. Even though there are smaller quantities of other ions in seawater (e.g., K +, Mg 2+, or SO 4 2 ), sodium and chloride ions represent about 91% of all seawater ions. is an important measurement in seawater or in estuaries where freshwater from rivers and streams mixes with salty ocean water. The salinity level in seawater is fairly constant, at about 35 ppt (35,000 mg/l), while brackish estuaries may have salinity levels between 1 and 10 ppt. Since most anions in seawater or brackish water are chloride ions, salinity can be determined from chloride concentration. The following formula is used: salinity (ppt) = 0.0018066 5 Cl (mg/l) A Chloride Ion-Selective Electrode can be used to determine the chloride concentration, which is converted to a salinity value using the above formula. can also be measured in freshwater. Compared to seawater or brackish water, freshwater has much Page 1 of 8

can also be measured in freshwater. Compared to seawater or brackish water, freshwater has much lower levels of salt ions such as Na + and Cl ; in fact, these ions are often lower in concentration than hard-water ions such calcium (Ca 2+ ) and bicarbonate (HCO 3 ). Because salinity readings in freshwater will be significantly lower than in seawater or brackish water, readings are often expressed in mg/l instead of ppt (1 ppt = 1000 mg/l). Increased salinity levels have been observed in the lower reaches of the Colorado and Rio Grande rivers, due to return of irrigation water (see Table 1). In these arid regions of the United States, water readily evaporates during irrigation, resulting in high concentrations of salt ions in the water returned to the rivers. is also of interest in bodies of water where seawater mixes with freshwater, since aquatic organisms have varying abilities to survive and thrive at different salinity levels. Saltwater organisms survive in salinity levels up to 40 ppt, yet many freshwater organisms cannot live in salinity levels above 1 ppt. Expected Levels Seawater has a chloride ion concentration of about 19,400 mg/l (a salinity of 35.0 ppt). Brackish water in tidal estuaries may have chloride levels between 500 and 5,000 mg/l (salinity of 1 to 10 ppt). Even freshwater streams and lakes have a significant chloride level that can range from 1 to 250 mg/l (salinity of 0.001 to 0.5 ppt). Table 1: Chloride and in Selected Sites Site (fall season) Chloride (mg/l) (mg/l) (ppt) Columbia River, Newport, WA 1.3 2.3 0.0023 Mississippi River, Memphis, TN 14.1 25.5 0.025 Rio Grande River, San Marcial, NM 56 101 0.101 Rio Grande River, Brownsville, TX 220 397 0.397 Colorado River, State Line, CO-UT 67 121 0.121 Colorado River, Andrade, CA 190 343 0.343 Summary of Methods Method 1: Chloride Concentration and (ISE) A Vernier Chloride Ion-Selective Electrode is used to measure the chloride ion concentration in the water (in mg/l) either on site or after returning to the lab. can be determined using the relationship, salinity (ppt) = 0.0018066 5 Cl (mg/l). Method 2: Using a Conductivity Probe (Seawater or Brackish Water) A Vernier Conductivity Probe is used to measure the salinity value of the water (in ppt). If salinity values exceed 13 ppt, dilution of samples, as described in the procedure, will be necessary. This method uses the assumption that most of the ions in the solution are non-carbonate salt ions (e.g., Na +, K +, or Cl ), and converts the conductivity reading to a salinity value. Method 1: CHLORIDE CONCENTRATION AND SALINITY (ISE) Materials Checklist Low Standard (10 mg/l Cl ) Page 2 of 8

Power Macintosh or Windows PC Vernier computer interface Logger Pro Chloride Ion-Selective Electrode wash bottle with distilled water Low Standard (10 mg/l Cl ) High Standard (1000 mg/l Cl ) Very High Standard (20,000 mg/l Cl ) tissues small paper or plastic cup (optional) Advanced Preparation The Vernier Chloride Ion-Selective Electrode (ISE) must be soaked in the Chloride High Standard solution (included with the ISE) for approximately 30 minutes. Important: Make sure the electrode is not resting on the bottom, and that the small white reference contacts are immersed. Make sure no air bubbles are trapped below the electrode. If the ISE needs to be transported to the field during the soaking process, use the Short- Term ISE Soaking Bottle. Remove the cap from the bottle and fill it ¾ full with High Standard. Slide the bottle s cap onto the ISE, insert it into the bottle, and tighten. Important: Do not leave the ISE soaking for more than 24 hours. Long-term storage should be in the Long-Term ISE Storage Bottle. ISE soaking for travel Collection and Storage of Samples 1. This test can be conducted on site or in the lab. A 100-mL water sample is required. 2. It is important to obtain the water sample from below the surface of the water and as far away from shore as is safe. If suitable areas of the stream appear to be unreachable, samplers consisting of a rod and container can be constructed for collection. Refer to page Intro-4 of the Introduction of this book for more details. Testing Procedure 1. Position the computer safely away from the water. Keep water away from the computer at all times. 2. Prepare the computer for data collection by opening Test 15 Chloride ISE from the Water Quality with Computers experiment files of Logger Pro. On the Graph window, the vertical axis has chloride concentration scaled from 0 to 20000 mg/l Cl. The horizontal axis has time scaled from 0 to 10 seconds. There is also a Meter window which displays live chloride concentration readings. 3. Prepare the Chloride Ion-Selective Electrode (ISE) for data collection. a. The ISE should be soaking in the High Standard. Make sure that it is not resting on the bottom of the container, and that the small white reference contacts are immersed. b. Plug the ISE Sensor into Channel 1 of the Vernier interface. 4. You are now ready to calibrate the Calcium ISE. First Calibration Point a. Choose Calibrate from the Experiment menu and then click. b. Type 1000 (the concentration in mg/l Cl ) in the edit box. c. When the displayed voltage reading for Input 1 stabilizes, click. Page 3 of 8

Second Calibration Point d. If you are testing a freshwater sample, place the tip of the electrode into the Low Standard (10 mg/l Cl ). If you are testing a seawater- or brackish-water sample, place the tip of the electrode into the Very High Standard (20,000 mg/l Cl ). Be sure that the electrode is not resting on the bottom of the bottle and that the small white reference contacts are immersed. Make sure no air bubbles are trapped below the electrode. e. After briefly swirling the solution, hold the ISE still and wait approximately 30 seconds for the voltage reading displayed on the computer screen to stabilize. f. Enter 10 (the concentration of the Low Standard) or 20,000 (the concentration of the Very High Standard), depending on which one you used. g. When the displayed voltage reading for Input 1 stabilizes, click, then click. 5. You are now ready to collect chloride concentration data. a. Rinse the ISE with distilled water and gently blot it dry. b. Place the tip of the probe into the stream at Site 1, or into a cup with sample water from the stream. Make sure the ISE is not resting on the bottom and that the small white reference contacts are immersed. Make sure that no air bubbles are trapped below the ISE. c. After briefly swirling the solution, hold the ISE still and wait approximately 30 seconds. d. If the chloride concentration value appears stable, simply record it on the Data & Calculations sheet and proceed to Step 7. 6. If the chloride concentration value displayed in the Meter window is fluctuating, determine the mean (or average) value. To do this: a. Click to begin a 10-second sampling run. Important: Leave the probe tip submerged for the 10 seconds that data is being collected. b. When the sampling run is complete, click on the Statistics button,, to display the statistics box on the graph. c. Record the mean chloride concentration value on the Data & Calculations sheet. 7. Return to Step 5 to obtain a second reading. 8. Determine the salinity value of your sample (in ppt). Use this formula to calculate the salinity, based on the chloride concentration, Cl salinity (ppt) = 0.0018066 5 Cl (mg/l) Record this value in the Data & Calculations table (round to the nearest 0.1 mg/l Cl ). DATA & CALCULATIONS Method 1: Chloride Concentration and (ISE) Stream or lake: Time of day: Site name: Site number: Page 4 of 8

Date: Column A B Reading 1 Chloride (mg/l Cl ) (ppt) 2 Average Column Procedure: A. Record the chloride concentration value (in mg/l Cl ) from the computer. B. Calculate salinity, using the formula: salinity (ppt) = 0.0018066 5 Cl (mg/l). Field Observations (e.g., weather, geography, vegetation along stream) Test Completed: Date: Method 2: SALINITY USING A CONDUCTIVITY PROBE Materials Checklist Power Macintosh or Windows PC wash bottle with distilled water Vernier computer interface tissues or paper towels Logger Pro 5 ppt salinity standard Vernier Conductivity Probe 10 ppt salinity standard 100-mL graduated cylinder small paper or plastic cup (optional) 500-mL bottle with lid Page 5 of 8

Collection and Storage of Samples 1. This test can be conducted on site or in the lab. A 100-mL water sample is required. 2. It is important to obtain the water sample from below the surface of the water and as far away from shore as is safe. If suitable areas of the stream appear to be unreachable, samplers consisting of a rod and container can be constructed for collection. Refer to page Intro-4 of the Introduction of this book for more details. Testing Procedure 1. Position the computer safely away from the water. Keep water away from the computer at all times. 2. Prepare the computer for data collection by opening Test 15 Conductivity from the Water Quality with Computers experiment files of Logger Pro. On the Graph window, the vertical axis has salinity concentration scaled from 0 to 13 ppt. The horizontal axis has time scaled from 0 to 10 seconds. There is also a Meter window which displays live chloride concentration readings. salinity). 3. Prepare the Conductivity Probe for data collection. a. Plug the Conductivity Probe into Channel 1 of the Vernier interface. b. Set the switch on the probe box to the 0-20000 µs range (0-13 ppt 4. You are now ready to calibrate the Conductivity Probe. If your instructor directs you to use the calibration stored in the experiment file, then proceed to Step 5. If your instructor directs you to perform a new calibration for the Conductivity Probe, follow this procedure: First Calibration Point a. Choose Calibrate from the Experiment menu and then click. b. Perform the first calibration point by placing the Conductivity Probe into the 5 ppt salinity standard. The hole near the tip of the probe should be covered completely. c. Type 5 (the salinity value) in the edit box. d. When the displayed voltage reading for Input 1 stabilizes, click. Second Calibration Point e. Place the Conductivity Probe into the 10 ppt salinity standard solution. The hole near the tip of the probe should be covered completely. f. Type 10 (the salinity value) in the edit box. g. When the displayed voltage reading for Input 1 stabilizes, click, then click. Page 6 of 8

h. Rinse the electrode with distilled water and gently blot it dry with a tissue. 5. You are now ready to collect salinity concentration data. a. Place the tip of the electrode into a cup with sample water from the body of water you are testing. The hole near the tip of the probe should be covered completely. b. Monitor the salinity concentration value in the Meter window. If the value is less than 13 ppt (the upper range of the Conductivity Probe), record this value on the Data & Calculations sheet. If you did a ¼ dilution of the sample, be sure to multiply this value by 4! If the salinity value is greater than 13 ppt, go to Step 7. 6. Repeat Step 5 to obtain a second reading. 7. If your salinity value is greater than 13 ppt, then the sample had a salinity value that is beyond the upper range of the Conductivity Probe. You will need to dilute the sample to a salinity value that is within the range of the probe. To do this, a. Use a graduated cylinder to add 100 ml of the water sample to a 500-mL bottle. b. Add 300 ml of distilled water to the sample in the bottle, screw the lid on, and shake it well. c. Important: The sample has been diluted by a factor of 100 / 400 or ¼. Any salinity measurements made on this sample will have to be multiplied by a factor of 4 to account for this dilution. d. Repeat Step 5 to obtain a second reading. DATA & CALCULATIONS Method 2: Using a Conductivity Probe Stream or lake: Time of day: Site name: Site number: Date: Column Reading A (ppt) 1 2 Page 7 of 8

Average Column Procedure: A. Record the salinity concentration as determined by interpolation of the calibration curve. Field Observations (e.g., weather, geography, vegetation along stream) Test Completed: Date: Page 8 of 8