AMPERA FEATURES LED solutions for an optimised return on investment Cost-effective and efficient lighting solution for a fast return on investment LensoFlex 2 photometric engine with photometry adapted to various applications 3 sizes for flexibility IP 66 tightness level Energy savings of up to 75% compared with traditional light sources Mounting with two separated parts for easy installation and set-up (inclination angle) Designed to incorporate Owlet control and sensor solutions ThermiX for long lasting performance Future Proof : smart upgradability Surge protection 10kV TYPES OF APPLICATION Urban roads and streets Roads and highways Residential streets Squares and pedestrian areas Roundabouts Pedestrian crossings Bridges Parks Car parks Bike paths Large areas www.schreder.com. 1/15
DIMENSION DRAWING DIMENSIONS AND CHARACTERISTICS Designer : Thomas Coulbeaut AMPERM (AMPERA MINI) AMPERD (AMPERA MIDI) AMPERX (AMPERA MAXI) Length (mm) 583 674 900 Width (mm) 340 436 438 Height (mm) 90 132 135 Weight (kg)** 8 12 18 Tightness level* IP 66 Impact resistance* IK 09 Electrical class* Class 1US, Class I EU, Class II EU Aerodynamic resistance (CxS) 0.087m² 0.115m² 0.176m² * According to IEC-EN60598 and IEC-EN62262 ** Average weight. The max weight is +/- 10% more but for the exact weight according to the configuration, please contact us. SUMMARY CONCEPT Family of 3 road LED luminaires: Mini, Midi, Maxi Recommended installation height: between 4 and 12m For optimal heat dissipation, the driver and LED engine are in separate compartments and juxtaposed in a horizontal section Independent optical & gear compartment ensures easy installation HOUSING & FINISH Housing in high-pressure, die-cast aluminium, polyester powder coated Direct and tool free access to housing with driver compartment and optical unit by releasing the lateral latches and pivoting downwards. Quick connectors (knife switch) allow easy removal of the housing. Colour: AKZO grey 900 sanded INSTALLATION Reversible fixation in high-pressure, die-cast aluminium Diameter 32-48, 48-60mm or 76mm, tightened with 2 stainless steel screws Can be tilted on a vertical pole from 0 to +15 ; on a horizontal spigot from 0 to -15 by 5 steps Tool free access for maintenance www.schreder.com. 2/15
OPTICAL UNIT Protected against lens degradation by 5mm thick extra-clear hardened glass Flatbed PCB with acrylic lens overlay principle Various photometric distributions: from narrow road to motorway, medium and large area CRI > 70 ULOR: 0% LED lumen depreciation Lifetime residual flux @ Tq=25 C @ 100.000 hrs: 350mA & 500mA: 90%; 700mA: 80% ELECTRICAL Class I or Class II Input voltage: 120-277V - 50-60Hz Power factor > 90% at full load 10kV, 10kA surge protection Power automatically switches off when opened Thermal protection on LED PCBA STANDARDS & CERTIFICATIONS CE ENEC LM79-80 ETL ROHS All measurements in ISO17025 accredited laboratory OPTIONS Other RAL or AKZO colours Back light control OWLET remote management Custom dimming profile; Constant Light Output (CLO); Bi-Power Photocell Presence detection www.schreder.com. 3/15
CONCEPT 1. Thermix for long lasting performance The thermal management of LEDs is crucial for a luminaire s reliability. To maximise effectiveness and maintain flux over time, several parameters are optimised: Thermal compartmentalisation between the LEDs and the control gear Direct conduction by minimising the path between the heat source and the outside Optimised design of the external heat exchange surface. Thermal protection of the LED PCBA: The PCB incorporates a temperature sensor (NTC resistor) which reduces the current to protect the LEDs at higher than rated ambient temperatures. The temperature sensor does not switch off the LEDs at high temperatures. In the worst case scenario (for example at sunset during the summer), the current will be dimmed and maintained at that level until the LED module cools down again. Then, the driver will gradually increase the LED current until the normal value is reached. 2. FutureProof: Smart Upgradability Since LED technology is constantly evolving, both the photometric engine and the gears can be replaced at the end of the LEDs lifespan to take advantage of future technological developments www.schreder.com. 4/15
OPTIONS 1. OWLET wireless remote management dimming & control system The luminaires are pre-programmable, wireless programmable or remotely programmable and controllable. Each individual light point can be switched off/on or dimmed at any time. Operating state, energy consumption and failures are reported and stored in a database with the exact timestamp and geographical location. Owlet helps lighting managers to assure the right lighting level while reducing operating costs and maintaining a sustainable outdoor lighting scheme. The wireless Luminaire Controllers (LuCo) exist in different types, all of them are compatible with each other. 1. Shows status of all light points per zone, per street 2. Defines dimming profiles automatically/manually 3. Produces reports automatically/manually (operating & consumption) 4. Alarm schemes (failures, faults, consumption via SMS, phone, email) 5. Connects to 3 rd party systems 6. Data exchange with other servers 7. Data management Available Luminaire Controllers: LuCo-PD: Wireless Individual Luminaire Controller with integrated photocell that is mounted on top of the luminaire. Connected to the driver via a cable. LuCo-NXP: Wireless Individual Luminaire Controller integrated inside the luminaire with shark fin antenna on top. Both types of luminaire controllers can control of individual luminaires or clusters of luminaires. They build a bidirectional mesh network amongst each other to the Segment Controller (one SeCo per 100/150 light points). The above mentioned LuCo s, are commissioned either manually introduction in the web GUI (Graphical User Interface) or via the use of a wireless handheld device that allows automatic geo-positioning on the Owlet NightShift GUI. *Segment controller & Antenna + cable order number: Equipment Order no. Description Segment Controller 00-05-921 Segment Control Segment Controller Cable + Antenna GSM/UMTS + Zigbee 2,4GHz 00-05-922 Cable 1m 00-05-924 Cable 2m 00-05-927 Cable 3m 00-05-925 Cable 5m 00-05-923 Cable 7m 00-05-926 Cable 10m Commissioning tool C777260 TMGT Wireless Handheld Tool Kit www.schreder.com. 5/15
2. Motion and/or presence detection Motion detection is compatible with any type of control or dimming system. It will enhance the efficacy of the installation by only increasing the light level when a vehicle or a pedestrian is detected. 2.1 Stand-alone luminaire This solution needs to be integrated in each luminaire if the installation is equipped with regular dimming without remote wireless connection. 2.2 Stand-alone network of luminaires To monitor stand-alone networks or luminaire clusters with motion and/or presence detectors. The location of the detection device can be multiple (for example, either attached or integrated in the luminaire or in a remote location. To detect the arrival of a person that requires light, the sensor can either be on one, on a selection of luminaires, on all luminaires or in a remote location for the most optimum detection. In that case, in addition to the sensor selection, the LuCo-ADP will serve as communication node in all of the luminaires in the network. Each sensor can be attributed to one or multiple luminaires and vice versa! LuCo-ADP: Wireless Individual Luminaire Controller to manage a cluster of luminaires. The LuCo is integrated inside the luminaire with an antenna on the top. The luminaires communicate between each other via a bi-directional mesh network. A Master or Segment Controller is only temporarily required during the set-up of the system. 2.3 Remote wireless solutions (interoperable) For installations with remote wireless solutions, the motion and presence detectors can also be located on one, on a selection of luminaires, on all luminaires or in a remote location to detect the arrival of people in the most optimum way. The LuCo-NXP and LuCo-PD will in that case play the role of the communication node. This option combines the functionality of the stand-alone network with remote wireless control. 2.4 Presence detection capabilities The detection capabilities depend on the height of the installation and the type of sensor. The settings of the luminaire will determine: - The temporisation: the length of time a luminaire is switched on when a presence is detected - When the sensor is idle or in detection mode - The inclination of the luminaire influences the scope of the detection zone The integration of sensors into round luminaires, needs to be synchronised and oriented according to the photometry and the motion path. Our staff is happy to help you with this analysis. www.schreder.com. 6/15
A stand-alone unit to integrate into a wireless Owlet control network; either autonomous or interoperable and equipped w/o PIR sensor: Equipment Order no. Description Moov-Box P6010000001beu P6010 MOOVBOX NO SENSOR LuCo-ADP Moov-Box P6010000002beu P6010 MOOVBOX WITH SENSOR LuCo-ADP Moov-Box P6010000003beu P6010 MOOVBOX WITH SENSOR LuCo-NXP Moov-Box P6010000004beu P6010 MOOVBOX NO SENSOR LuCo-NXP 3. Dimming without wireless remote management Custom dimming profile; Constant Light Output (CLO); Bi-Power dimming and Dali are available. 3.1 Custom Dimming This option enables dimming profiles with up to 5 levels to adapt the light according to the real needs during the night. The dimming profile can be set up in two ways. The standard way determines the dimming profiles based on the middle of the night and is fully operational after 3 full nights. The second way (on request) determines that the night starts from the moment that the lights are switched on. The dimming profiles are immediately operational. 3.2 Constant Light Output This system compensates for the depreciation of luminous flux and to avoid excess lighting at the beginning of the installation's service life, providing substantial energy savings. Standard lighting consumption LED lighting consumption with CLO Energy savings 3.3 Bi-Power functionality In several countries an extra wire, a so-called control wire or switched line, is distributed throughout the street lighting network. In most cases, when the street lighting is switched on, both the line and the switched line are energized to the 230V level. At a certain point during the night this switched line is switched off from the grid. The bi-power driver detects this signal as a command to reduce the output current to a lower preset value. In most cases this value equals 50%. www.schreder.com. 7/15
4. Photocell The photocell will switch on the luminaire as soon as daylight has reached a certain level. The photocell is compatible with regular or programmable drivers. Our photocell catalogue is at your disposal should you require a particular photocell according to your regional requirements and regulations. 5. Advanced Photometry 5.1 Back Light control Back Light control will prevent light spill from the back of the luminaire. 5.2 Pedestrian crossing Schréder has designed specific photometric distributions to meet the challenges of providing secure pedestrian crossings while maintaining aesthetical consistency in the urban landscape. These lenses exist for pedestrian crossings, whether it is a one-way, two lane or three lane application. For one-way traffic, one single luminaire is able to light a pedestrian crossing for a 2 lane road. For a 3 lane one-way traffic road, a second luminaire will be necessary at the opposite side of the road. For 2 way traffic road, a minimum of two luminaires is necessary to create a positive contrast for traffic in both directions. 6. Other colours available Other RAL or AKZO colours are available on request. www.schreder.com. 8/15
LUMEN AND POWER DETAILS Typical data for Neutral White (NW) LEDs (4000 K, CRI min. 70) at Tq 25 C. Model Acronym Colour temp. Flux code Typical luminaire output (lm) Luminaire power (W) Luminaire efficacy (lm/w) Current (ma) Typical LED flux (lm) AMPERA MINI AMPERM NW 001A0 1000 10 100 350 1200 8 AMPERA MINI AMPERM NW 001A1 1400 14 100 500 1600 8 AMPERA MINI AMPERM NW 001A2 1800 19 95 700 2100 8 AMPERA MINI AMPERM NW 002A3 2000 18 111 350 2400 16 AMPERA MINI AMPERM NW 002A4 2700 26 104 500 3200 16 AMPERA MINI AMPERM NW 003A5 3000 27 111 350 3600 24 AMPERA MINI AMPERM NW 003A6 3500 36 97 700 4200 16 AMPERA MINI AMPERM NW 004A7 4100 38 108 500 4900 24 AMPERA MINI AMPERM NW 005A8 5300 55 96 700 6300 24 AMPERA MIDI AMPERD NW 004A0 4100 36 114 350 4800 32 AMPERA MIDI AMPERD NW 005A1 5500 51 108 500 6400 32 AMPERA MIDI AMPERD NW 006A2 6100 51 120 350 7200 48 AMPERA MIDI AMPERD NW 007A3 7100 71 100 700 8400 32 AMPERA MIDI AMPERD NW 008A4 8100 70 116 350 9600 64 AMPERA MIDI AMPERD NW 008A5 8200 75 109 500 9600 48 AMPERA MIDI AMPERD NW 010A6 10600 106 100 700 12500 48 AMPERA MIDI AMPERD NW 010A7 10900 99 110 500 12900 64 AMPERA MIDI AMPERD NW 014A8 14200 139 102 700 16700 64 AMPERA MAXI AMPERX NW 009A0 9900 86 115 350 12000 80 AMPERA MAXI AMPERX NW 011A1 11900 109 109 350 14400 96 AMPERA MAXI AMPERX NW 013A2 13400 122 110 500 16200 80 AMPERA MAXI AMPERX NW 013A3 13900 124 112 350 16800 112 AMPERA MAXI AMPERX NW 015A4 15900 140 114 350 19200 128 AMPERA MAXI AMPERX NW 016A5 16100 153 105 500 19400 96 AMPERA MAXI AMPERX NW 017A6 17300 180 96 700 20900 80 AMPERA MAXI AMPERX NW 018A7 18800 174 108 500 22700 112 AMPERA MAXI AMPERX NW 020A8 20700 213 97 700 25100 96 AMPERA MAXI AMPERX NW 021A9 21400 198 108 500 25900 128 AMPERA MAXI AMPERX NW 024AA 24200 245 99 700 29200 112 AMPERA MAXI AMPERX NW 027AB 27600 279 99 700 33400 128 LED Count Note: The flux is an indicative average and may vary with the different optics and types of protector. Tolerance on LED flux is ± 7% and on total luminaire power ± 5 %. The precise flux and corresponding matrix for each configuration are available on www.schreder.com www.schreder.com. 9/15
Typical data for Warm White (WW) LEDs (3000 K, CRI min. 80) at Tq 25 C. Model Acronym Colour temp. Flux code Typical luminaire output (lm) Luminaire power (W) Luminaire efficacy (lm/w) Current (ma) Typical LED flux (lm) AMPERA MINI AMPERM WW 000A0 900 10 90 350 1100 8 AMPERA MINI AMPERM WW 001A1 1300 14 93 500 1500 8 AMPERA MINI AMPERM WW 001A2 1700 19 89 700 2000 8 AMPERA MINI AMPERM WW 001A3 1900 18 106 350 2200 16 AMPERA MINI AMPERM WW 002A4 2500 26 96 500 3000 16 AMPERA MINI AMPERM WW 002A5 2800 27 104 350 3400 24 AMPERA MINI AMPERM WW 003A6 3300 36 92 700 3900 16 AMPERA MINI AMPERM WW 003A7 3800 38 100 500 4500 24 AMPERA MINI AMPERM WW 005A8 5000 55 91 700 5900 24 AMPERA MIDI AMPERD WW 003A0 3800 36 106 350 4500 32 AMPERA MIDI AMPERD WW 005A1 5100 51 100 500 6000 32 AMPERA MIDI AMPERD WW 005A2 5700 51 112 350 6700 48 AMPERA MIDI AMPERD WW 006A3 6600 71 93 700 7800 32 AMPERA MIDI AMPERD WW 007A4 7600 75 101 500 9000 48 AMPERA MIDI AMPERD WW 007A5 7600 70 109 350 9000 64 AMPERA MIDI AMPERD WW 009A6 9900 106 93 700 11700 48 AMPERA MIDI AMPERD WW 010A7 10200 99 103 500 12000 64 AMPERA MIDI AMPERD WW 013A8 13200 139 95 700 15600 64 AMPERA MAXI AMPERX WW 009A0 9300 86 108 350 11200 80 AMPERA MAXI AMPERX WW 011A1 11100 109 102 350 13400 96 AMPERA MAXI AMPERX WW 012A2 12500 122 102 500 15100 80 AMPERA MAXI AMPERX WW 013A3 13000 124 105 350 15700 112 AMPERA MAXI AMPERX WW 014A4 14800 140 106 350 17900 128 AMPERA MAXI AMPERX WW 015A5 15000 153 98 500 18100 96 AMPERA MAXI AMPERX WW 016A6 16100 180 89 700 19500 80 AMPERA MAXI AMPERX WW 017A7 17500 174 101 500 21200 112 AMPERA MAXI AMPERX WW 019A8 19300 213 91 700 23400 96 AMPERA MAXI AMPERX WW 020A9 20000 198 101 500 24200 128 AMPERA MAXI AMPERX WW 022AA 22600 245 92 700 27300 112 AMPERA MAXI AMPERX WW 025AB 25800 279 92 700 31200 128 LED Count Note: The flux is an indicative average and may vary with the different optics and types of protector. Tolerance on LED flux is ± 7% and on total luminaire power ± 5 %. The precise flux and corresponding matrix for each configuration are available on www.schreder.com www.schreder.com. 10/15
Typical data for Cool White (CW) LEDs (6200 K, CRI min. 70) at Tq 25 C. Model Acronym Colour temp. Flux code Typical luminaire output (lm) Luminaire power (W) Luminaire efficacy (lm/w) Current (ma) Typical LED flux (lm) AMPERA MINI AMPERM CW 001A0 1000 10 100 350 1200 8 AMPERA MINI AMPERM CW 001A1 1400 14 100 500 1600 8 AMPERA MINI AMPERM CW 001A2 1800 19 95 700 2100 8 AMPERA MINI AMPERM CW 002A3 2000 18 111 350 2400 16 AMPERA MINI AMPERM CW 002A4 2700 26 104 500 3200 16 AMPERA MINI AMPERM CW 003A5 3000 27 111 350 3600 24 AMPERA MINI AMPERM CW 003A6 3500 36 97 700 4200 16 AMPERA MINI AMPERM CW 004A7 4100 38 108 500 4900 24 AMPERA MINI AMPERM CW 005A8 5300 55 96 700 6300 24 AMPERA MIDI AMPERD CW 004A0 4100 36 114 350 4800 32 AMPERA MIDI AMPERD CW 005A1 5500 51 108 500 6400 32 AMPERA MIDI AMPERD CW 006A2 6100 51 120 350 7200 48 AMPERA MIDI AMPERD CW 007A3 7100 71 100 700 8400 32 AMPERA MIDI AMPERD CW 008A4 8100 70 116 350 9600 64 AMPERA MIDI AMPERD CW 008A5 8200 75 109 500 9600 48 AMPERA MIDI AMPERD CW 010A6 10600 106 100 700 12500 48 AMPERA MIDI AMPERD CW 010A7 10900 99 110 500 12900 64 AMPERA MIDI AMPERD CW 014A8 14200 139 102 700 16700 64 AMPERA MAXI AMPERX CW 009A0 9900 86 115 350 12000 80 AMPERA MAXI AMPERX CW 011A1 11900 109 109 350 14400 96 AMPERA MAXI AMPERX CW 013A2 13400 122 110 500 16200 80 AMPERA MAXI AMPERX CW 013A3 13900 124 112 350 16800 112 AMPERA MAXI AMPERX CW 015A4 15900 140 114 350 19200 128 AMPERA MAXI AMPERX CW 016A5 16100 153 105 500 19400 96 AMPERA MAXI AMPERX CW 017A6 17300 180 96 700 20900 80 AMPERA MAXI AMPERX CW 018A7 18800 174 108 500 22700 112 AMPERA MAXI AMPERX CW 020A8 20700 213 97 700 25100 96 AMPERA MAXI AMPERX CW 021A9 21400 198 108 500 25900 128 AMPERA MAXI AMPERX CW 024AA 24200 245 99 700 29200 112 AMPERA MAXI AMPERX CW 027AB 27600 279 99 700 33400 128 LED Count Note: The flux is an indicative average and may vary with the different optics and types of protector. Tolerance on LED flux is ± 7% and on total luminaire power ± 5 %. The precise flux and corresponding matrix for each configuration are available on www.schreder.com www.schreder.com. 11/15
PHOTOMETRY 5068AS Wide 5096AS Medium 5098AS Medium 5102AS Medium 5102BL Back light Medium www.schreder.com. 12/15
5103AS Wide 5112AS Wide 5117AS Wide 5118AS Medium 5119AS Extra-wide www.schreder.com. 13/15
5120AS Asymmetrical 40 5121AS Asymmetrical 60 5136AS Narrow 5137AS Medium 5138AS Medium www.schreder.com. 14/15
5139AS Wide 5140AS Medium 5141AS Wide 5144AS Zebra left Pedestrian crossing 5145AS Zebra right Pedestrian crossing www.schreder.com. 15/15
How to create a valid ordering code? 1 to the Ordering Data page(s) and compose your solution by choosing one code per column Go in order to specify the PRODUCT ID, country (of installation), optical BLOCK, GearS, Controls, Fixations and Colour. You may choose several Options. 2 your solution easily: most of the proposed options do not require Configure any additional information and are briefly explained below the code (refer to the footnotes to check compatibility between the selected options). 3 your Flux, Photometry and Control codes by referring to more detailled information included in the Product Choose Sheet. Depending on your choice of colour temperature, please refer to the corresponding table to find the flux code for the typical lumen package you require (*). Please check the Product ID to make sure that the lumen package you need is available with the size you have chosen. To choose the photometry, refer to the 4 digit codes beside the curves and diagrams (*). AS = asymmetrical, SY = symmetrical and BL = Back Light control. (*) The precise flux and corresponding matrix for each configuration are available on www.schreder.com To configure the ideal solution between the features you need and the available controllers, refer to the description in the Product sheet. examples of valid ordering codes only with standard features with customised requests PRODXX - 00 - NW008AH - 5118BL - GL01 - V02D03S3 - C000 - C201 - U4 - A1 - A6-0L Product ID (6 digits) Universal (2 digits) ISO 3166 country code (2 digits) Colour temperature + Flux code (7 digits) Photometry type (6 digits) Custom photometry Protector type (2 digits) Voltage & elec. class + Dimming + Elec. protection (8 digits) Voltage & elec. class + Custom dimming + Elec. protection (8 digits) Power cable type (4 digits) Custom power cable (4 digits) Controller + Photocell + Sensor (4 digits) Custom contr., Photocell & Sensor (4 digits) Fixation (2 digits) Options (2 digits each) Colour (2 digits) Customised options (Photometry, Dimming, Cables, Control & Photocell) for which you will receive a specific code (4 digits each) Specific RAL colour (8 digits) PRODXX - AT - NW008AH - CUSTOM - GL04 - V02D04S3 - CJZZ - ZZZZ - U4 - PXXX - DXXX - CXXX - SXXX - TXXX - RAL3005M
ORDERING DATA ID COUNTRY OPTICAL BLOCK GEARS CONTROLS [4] FIXATIONS OPTIONS COLOUR PRODUCT ID COUNTRY OF INSTALLATION [1] AMPERA COLOUR TEMP FLUX CODE [2] PHOTOM ETRY TYPE [3] PROTECTOR VOLTAGE & EL. CLASS DIMMING ELECTR. PROTECTION POWER CABLE CABLE TYPE CONTROLLER PHOTO CELL SENSOR FIXATIONS OPTIONS [5] COLOUR AMPERM 00 NW 5068AS GL01 V01 D00 S3 C0 00 C0 0 0 U2 N0 0N Universal Neutral Flat Glass 120V CLI No Dimming 10kV - no Fuse No Cable No Cable No Controller No Photocell No Sensor Universal 32mm No Others AKZO 900 GS AMPERD Standard White 5096AS AMPERX AO WW 5098AS V02 D01 CH 2C C1 B 1 U3 A2 0B Angola Warm 230V CLI 0-10V Cable length 2X1.5² LuCo-NXP Nema Socket PIR Presence Universal 42-48mm Gear Plate RAL 3004 T White 5102AS 4m AR CW 5103AS V03 D02 CI 2D C2 E Z U4 A6 0C Argentina Cold White 230V CLII DALI Cable length 2X2.5² LuCo-ADP Nema Socket 7 pins CUSTOM Universal 48-60mm Seaside RAL 6005 T 5112AS 5m SENSOR AU 5117AS V14 D03 CJ 3B C3 G U5 AA 0D Australia 277V CLI Bi-Power 50% (if switched Cable length 3X1.5² LuCo-PD Ø20 hole Universal 76mm Special labeling RAL 6009 B 5118AS line OFF) 6m 5119AS V04 D04 CK 3C C4 H PXXX 0E 347V CLI Custom Dimming Profile Cable length 3G1.5² LuCo-P7 Nema Socket 6 pins Photometry RAL 7016 B 5120AS 7m custom 5121AS V05 D05 CL 3D ZZ I DXXX 0F 480V CLI No Dimming + CLO Cable length 3X2.5² CUSTOM 20 lux 1:1 IP67 Dimming profile RAL 7035 B 5136AS 8m CONTROLLER custom 5137AS D06 CM 3E J CXXX 0G 0-10V + CLO Cable length 3G2.5² 35 lux 1:0.5 Cables custom RAL 7040 B 5138AS 9,5m 5139AS D07 CN 4C K SXXX 0H DALI + CLO Cable length 4X1.5² 35 lux 1:0.5 IP67 Control/Sensor RAL 7040 T 5140AS 10m position, type, 5141AS D08 CO 4D L TXXX 0I Bi-Power 50% (if switched Cable length 4G1.5² 55 lux 1:0.5 Photocell RAL 9005 B 5144AS line OFF) + CLO 12m 5145AS D09 CP 4E M LXXX 0J Custom Dimming Profile + Cable length 4X2.5² 55 lux 1:0.5 IP67 Label custom RAL 9006 B 5102BL CLO 15m 5103BL D14 CQ 4F N FXXX 0K Bi-Power 50% (if switched Cable length 4G2.5² 70 lux 1:0.5 Finishing Colour, RAL 9011 T 5112BL line ON) 20m vernish, 5117BL D15 5A O OXXX 0L Telemanagement 5G1.5² 70 lux 1:0.5 IP67 Others AKZO 150 GS 5118BL 5119BL D16 ZZ Z 0M Bi-Power 30% (if switched CUSTOM CUSTOM PHOTOCELL AKZO 200 BS 5120BL line OFF) CABLE 5121BL D17 0O Bi-Power 30% (if switched RAL 7038 B 5136BL line OFF) + CLO Ampera Product Sheet - 13/03/2015 - To make sure this is the most recent revision, please consult www.schreder.com
ORDERING DATA ID COUNTRY OPTICAL BLOCK GEARS CONTROLS [4] FIXATIONS OPTIONS COLOUR PRODUCT ID COUNTRY OF INSTALLATION [1] AMPERA COLOUR TEMP FLUX CODE [2] PHOTOM ETRY TYPE [3] PROTECTOR VOLTAGE & EL. CLASS DIMMING ELECTR. PROTECTION POWER CABLE CABLE TYPE CONTROLLER PHOTO CELL SENSOR FIXATIONS OPTIONS [5] COLOUR 5137BL D18 0P Bi-Power 30% (if switched RAL 9003 M 5138BL line ON) 5139BL 5140BL 5141BL 5144BL 5145BL CUSTOM* 0R RAL 9022 T 0S RAL 7001 T 0T RAL 9006 M 0U RAL 9005 M 0V RAL7040 M 0W RAL 9006 T 01 RAL 7037 T RALxxxx M Other RAL colour Matte RALxxxx B Other RAL colour Brilliant RALxxxx T Other RAL colour Textured Your Order AMPER GL01 V D S _ C _ C _ Example: AMPERD-AT-NW008A4-5102AS-GL01-V03D00S3-CJ2C-C000-U2-N0-0N Notes: +++ 8 LEDs version available only with 230V and DALI. +++ CL II with 10kV surge protection available in differential mode only. +++ Bi-Power need gear plate +++ LuCo-NXP and LuCo-ADP available only with D15 Telemanagement [1] Please provide country of installation to ensure country specific settings are taken into account. Schréder will provide you the code to use (00 (universal standard) or the country's ISO code). [2] See further Lumen and Power details table. [3] See further Photometrics table. [4] Schréder fixtures are compatible with most controls equipment available on the market. Please contact Schréder for more information. [5] Multiple SELECTIONS and VARIANTS concatenation possible eg. -A2-AA-P0Z0-D0W0-C0Y0-S0M0-L0H0. *Please contact Schréder to specify your requirement. A custom requirement must be validated by Schréder and may impact the delivery leadtime. ZZ Other specific paint* Ampera Product Sheet - 13/03/2015 - To make sure this is the most recent revision, please consult www.schreder.com