Model DE-3 Air Release Head

Similar documents
Air Eliminators and Combination Air Eliminators Strainers

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

Morrison Bros. Co. General Product Specifications

Features and Benefits

Assisted lift operated 2/2-way solenoid valves Type EV250B

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

Automatic Self-Cleaning Strainers

Solenoid valves 2/2-way direct-operated Type EV210A

4 Posiflow Proportional Solenoid Valves

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Smith Meter AccuLoad III

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Scraper Passage Indicator. Electrical Indicator. Features

The Unique Accelabar Flow Meter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Variable Area Flowmeters

Stainless Steel Valves For the Sanitary Industries

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Toroidal Conductivity Sensor

VAD. Variable Area Desuperheaters

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

DESIGN STANDARDS SECTION

Model 43AP Pneumatic Controller, Style B

PRESSURE REDUCING CONTROL VALVE

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS

Solenoid and Air Operated Valves. Supporting Fleet Operations for Over 60 Years

08.08 Vic-Check Valves

NAVIEN AMERICA INC FITCH AVENUE

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

HYDROSTATIC TEST PUMPS

VIKING HEAVY DUTY PUMPS SERIES 4195 STANDARD CONSTRUCTION

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Goulds Water Technology

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

REGULATORS 175/153 Series

Specification Data CM /10. Putting You In Control Series MiniTork ll Control Valves. Heavy Duty Control Butterfly Valves

Typical Aluminum GFM Mass Flow Meter

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

TorqPlus TM Electric Valve Actuators and Controls

300 Series PA Pump and Cooler Assemblies

Model 1210C Battery Powered Pump Shown. Description

MAC-120HE-01 Air-Cooled Chiller

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

FLASH TANK ECONOMIZER PRODUCT GUIDE

Centro-Matic Automatic Lubrication Systems System Controls

Electronic Flow Switches

! WARNING. Before using product, read and understand instructions.

1301 Series High-Pressure Regulators

Explosion-Proof Electric Unit Heaters

Sanitary Type Electronic Flow Switches

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

WHOLESALE DIRECT INC WEST 65TH STREET

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Float and Thermostatic Traps Series H, C and X

3/2-way Solenoid Valve, direct-acting, NC or NO

Mono-Block II Installation & Operation Manual

Powers Controls TH 192 S Single Temperature Room Thermostat

TECHNICAL BULLETIN. Kämmer LinedFlow Corrosive Application Valves. Experience In Motion FCD KMENTB /12

Type 92S Pilot-Operated Steam Regulator

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial

Copper Meter Resetters

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Automated Lubrication Systems Parts & Accessories

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

In-Line Electronic Flow Switches

Screw Plug Immersion Heaters

KLE-115U Single Rack Undercounter Configuration Instruction Manual

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Vogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS ARS PAGE 1 OF 5

Baumann Flexsleev Sanitary Control Valve

Transcription:

SPECIFICATIONS MEASUREMENT SOLUTIONS Model Air Release Head Bulletin SS03037 Issue/Rev. 0.2 (10/15) We put you first. And keep you ahead. SMITH METER AIR ELIMINATOR The Smith Meter Model Air Release Heads are an electric float switch devices for installation on a model AR or VAR air eliminator tanks. They are intended to be used in metering systems where air entrapped in the product is particularly troublesome (e.g., pumping off tank trucks and barges). The triple float switch air release head provides a unique method of air elimination designed to function in an unloading or Petro-gard II system. The elimination of air from liquid product is essential for accurate metering. The is used in conjunction with the AccuLoad Preset controller that operates the control valve, air eliminator solenoid and pumps. With the probability of a large slug of air at the beginning and end of the batch, and possible entrapped air during the batch, the operation of the air release head functions to remove the air as it accumulates in the tank. The three float switches suspended at different levels in the tank sense the level of fluid and perform the appropriate functions as programmed in the AccuLoad. FEATURES»» Efficient Air Elimination Performs under a wide range of operating conditions.»» Hazardous Areas Suitable for use in NEC Class I, Division 1, Group D¹. PRINCIPLE OF OPERATION 2 Maximum Flow Rate Smith Meter Model Air Release Head is designed to be used in conjunction with a Petro-gard II unloading system interfaced to an AccuLoad. The three float switches on the assembly are configured as Stop 1 Since power must be present at the reed switches in the float stem within the vessel, damage to the stem could cause a short circuit. Danger of an explosion is eliminated by the use of safety barriers, which limit the current below the level where incendiary sparking can occur. 2 The principle of operation described is only one of the possible sequences of operation available with the AccuLoad. (lower switch), Low (middle switch) and High (top switch) flow digital inputs in the AccuLoad to define when to open the flow control valve, when to advance from the low flow rate to high flow rate and when to close the valve in the unloading system. When the batch is started, the main pump is turned on and product begins to fill the system and the AccuLoad monitors the Stop float switch. The control valve remains closed to allow the air vent solenoid to vent the initial slug of air from the tank. The vented air should be plumbed to a low pressure point in a safe location such as a tank or sump. The location must be considered as vapors will vent and accumulate. If the vent solenoid should fail in sealing, there is also the possibility of fluid accumulation in the vent line. A sight glass is incorporated in the vent plumbing to verify that the product is not bypassing the meter. When the Stop float switch is activated, the control valve is opened and low flow is initiated as programmed in the AccuLoad. An optional zero flow timer can be programmed into the AccuLoad. If this option is not used, as the fluid level rises in the tank, the zero flow timer counts down. If the Stop float switch is not activated by the incoming fluid within the countdown timer, the batch is stopped.

As the tank fills with product and air is vented through the air vent solenoid, the middle and upper float switches are monitored. Once the middle and the upper float switches are activated, the AccuLoad will initiate the high flow rate programmed in the AccuLoad. If during the batch entrapped air in the fluid accumulates in the tank so that the fluid level drops below the upper and the middle float switches, the low flow rate will remain until the air is vented and the middle and the upper float switches are raised. At this time, the high flow will be returned to resume delivery of the batch. At the end of the batch, the fluid level in the tank will lower as air enters the tank. As the air accumulates, the upper and the middle floats will drop initiating low flow. The delivery will continue at low flow until the fluid level in the tank drops to the lower float switch. When the lower float drops, the AccuLoad will close the flow control valve and turn off the main pump. *Reference AB06055 for optional gear pump operation and product detection using Boolean equations in the AccuLoad. AIR VENT RATE 450 SPECIFICATIONS Viscosity : Up to 45 mpa s 3 (200 SSU) V: Up to 19.8 mpa s 3 (100 SSU) Consult factory for higher viscosities. Recommended Product Specific Gravity : 0.65 or greater V: 0.40 or greater Pressure Rating 150 psi (1,034 kpa) maximum working pressure with standard solenoid Temperature Range -10 F to 225 F (-12 C to 107 C) For other temperatures, consult factory Power Requirements Voltage: : 120 VAC +0% - 15%, 50/60 Hz Optional: 240 VAC +0% - 15%, 50/60 Hz For other voltages, consult factory. Weight : 20 lb (9.1 kg) V: 53 lb (24.0 kg) 40 Vent Rate Ft /Min. (scfm) 3 400 350 300 250 200 150 100 50 High Capacity V 0 0 20 40 60 80 100 120 140 Pressure Differential Across Vent Line (psig) Vent Rate Actual Ft /Min. (acfm) 3 35 30 25 20 15 10 5 0 High Capacity V 0 20 40 60 80 100 120 140 Pressure Differential Across Vent Line (psig) MATERIALS OF CONSTRUCTION (WETTED PARTS) Model Type Float Assembly Mounting Plate Tubing and Fittings/ Pilot s s 4 Sight Glass 316 S.S. Carbon Steel Carbon Steel/Viton Low Swell Buna 300/400 S.S./Viton/ Low Swell Buna Brass V 316 S.S. Carbon Steel Carbon Steel/Viton 300/400 S.S./Viton Stainless Steel 3 1,000 mpa s = 1,000cP = 1 Pa s. 4 Consult factory for alternate materials. 2 Bulletin SS03037 Issue/Rev. 0.2 (10/15)

MODELING CODE for Horizontal AR Tank Example Type Plate Float Volt / Special C 5 6 Strainer Type Triple Float Configuration Mounting Plate / Material C Smith Meter/"RB" Bolt Circle/Carbon Steel CF Smith Meter/"RB" Bolt Circle/Carbon Steel/FIC-3 AC 3" 150 ASME Flange/ Carbon Steel Float Assembly 3 PTFE 5 Floats with 316 Stainless Steel Stem - Used for model AR-3-1030 4 PTFE 5 Floats with 316 Stainless Steel Stem - Used for model AR-4-2040 6 PTFE 5 Floats with 316 Stainless Steel Stem - Used for model AR-6-3050 7 PTFE 5 Floats with 316 Stainless Steel Stem - Used for model AR-6-4565 and AR-8-45100 Voltage / (All Stainless Steel) 6 120/60 Viton-F Stainless Steel 7 240/60 Viton-F Stainless Steel 8 120/60 Viton-F H-coil Stainless Steel 9 110/50 Viton-F Stainless Steel 10 220/50 Viton-F Stainless Steel 11 120/60 Chemraz H-coil Stainless Steel 12 110/120 Viton-A High Capacity Stainless Steel Special 0 Nothing Special T Tee Vent Plumbing HC High Capacity Plumbing ET Ethanol or Bio-Diesel Service (no sight glass) 5 Polytetrafluoroethylene (PTFE) Bulletin SS03037 Issue/Rev. 0.2 (10/15) 3

MODELING CODE V for Vertical VAR Tank Example Type Plate Float Volt / V CC 1 1 Strainer Type V Triple Float Configuration Mounting Plate / Material CC 6" 150 ASME Flange/Carbon Steel/FIC-3 Float Assembly 1 PTFE 5 float s.g. 0.45/316 Stainless Steel Stem 2 316 Stainless Steel float s.g. 0.40/316 Stainless Steel Stem Voltage / (All Stainless Steel) 1 110/120 Viton-A Stainless Steel 2 220/240 Viton-A Stainless Steel 3 110/120 Viton-A Stainless Steel (Class H Coil) 4 Bulletin SS03037 Issue/Rev. 0.2 (10/15)

FIGURES Flame * 03A Ball 10B Air Vent (N.C) Sight Glass Customer Supplied Input Power J. Box w/relay, Current Limited Barrier Plug To AccuLoad Mounting Plate Upper AR Tank Middle Float Switch Assembly Supply To Meter Lower *Can be connected to Vapor Recovery Figure 1 Smith Meter Model with Model AR Air Eliminator Tank Customer Supplied Input Power 03A Ball 10B Sight Glass Air Vent (N.C) J. Box w/relay, Current Limited Barrier To AccuLoad Plug Mounting Plate VAR Tank Supply Upper Middle Float Switch Assembly Lower To Meter *Can be connected to Vapor Recovery Figure 2 Smith Meter Model V with Model VAR Air Eliminator Tank Bulletin SS03037 Issue/Rev. 0.2 (10/15) 5

DIMENSIONS () Inches (Millimeters) Conduit Connection 0.500 - (14) NPT Approx. 5.25 (133.4) Sight Glass We put you first. 17.50 And keep (444.5) you ahead. Ball Flame Barrier 10.06 (255.5) 3.50 (88.9) 6.00 (152.4) 7.37 (187.5) 10.06 (255.5) Approx. 18.75 (476) for 4" Air Eliminator 15.75 (400) for 3" Air Eliminator 38.25 (971.5) for Vertical Eliminator Conduit Connection 0.500 - (14) NPT Approx. 5.25 (133.4) 2.25 (57.2) Sight Glass 17.50 (444.5) Ball Flame Barrier 3.50 (88.9) 7.37 (187.5) 6.00 (152.4) x. for 4" Air Eliminator for 3" Air Eliminator 2.25 (57.2) 5) for Vertical Revisions Eliminator included in SS03037 Issue/Rev. 0.2 (10/15): Changed sight glass material to brass. Remove PWHT from special option. Correct mounting plate on Figure 2. Remove #7 from Model Horizontal AR Tank Float Assembely Chart. Updated modeling code for for horizontal AR tank. Replaced photo. The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. Contact information is subject to change. For the most current contact information, visit our website at www.fmctechnologies.com/measurementsolutions and click on the Contact Us link in the left-hand column. www.fmctechnologies.com/measurementsolutions 2015 FMC Technologies. All rights reserved. SS03037 Issue/Rev. 0.2 (10/15) FMC Technologies Measurement Solutions, Inc. 500 North Sam Houston Parkway West, Suite 100 Houston, Texas 77067 USA P:+1 281.260.2190 USA Operation 1602 Wagner Avenue Erie, Pennsylvania 16510 USA P:+1 814.898.5000 Germany Operation Smith Meter GmbH Regentstrasse 1 25474 Ellerbek, Germany P:+49 4101 304.0 6