Ammeter / Voltmeter Series 8402, 8403, 8405, 8404



Similar documents
Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices SolConeX 16 A Series 8570

Series 8146/5-V37 and Series 8150/5-V37

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Control and Distribution Boxes made of Stainless Steel Series 8150

Terminal Boxes Series 8146

Linear Luminaire with LED Series EXLUX 6402/2

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Flameproof Audible Signal 115 db (A) Series YA90

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

2.12. page Products for Explosion hazardous Environment

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Control Stations Made of Polyester Resin Series 8146

7 Lighting Technology

9 Control Equipment. Control Button Series 8082

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Solenoid Valve Island Type 3965

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

A good connection. International approvals.

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Technical Data. Dimensions

8146/5 Series Breaker Panelboards

Vario-Series Accessories

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Control- and feedback head for integrated mounting on Robolux valves Type 2036

STB Series Enclosures

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Electro-pneumatic control valves

Safety technique. Emergency stop module BO 5988 safemaster

Power Supplies 3. SDN-P DIN Rail Series

48 SERIES Relay interface modules 10 A

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

MINI MCR-SL-R-UI(-SP)

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Flow switches Series AD/VH

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

1756 ControlLogix Chassis Specifications

Floodlight Range Installation Guide

SINEAX U553 Transducer for AC Voltage

5SV Residual Current Protective Devices

DS 600. A contact free flux gate based current measurement sensor 600A rms

Redundancy Module QUINT-DIODE/40

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Actuator-Sensor-Interface

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Microcor Wireless Transmitter (MWT)

Inductive sensor NI10-M18-Y1X-H1141

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Digital inductive conductivity transmitter

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

FGM 160 ATEX EC type examination certificate

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Differential-Hall-Effect based Sensors Series A5S Overview

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Technical Information RIA14

3/2-way Solenoid Valve, direct-acting, NC or NO

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

S-series Mass Connection Solutions

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Thermometer in stainless steel with capillary and switch contacts

TEIP11 I/P signal converter for standard signals. Measurement made easy

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

Pluggable interface relays CR-P Pcb relays

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Circuit Breakers. NRC Series. NRC Series

TTF300 Field-mount temperature transmitter

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

Assisted lift operated 2/2-way solenoid valves Type EV250B

Compact pressure switch Flameproof enclosure Ex d Model PCA

J TB/TW Temperature limiter, temperature monitor

ConSig 8040 Series CONTROLS Features:

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Terminal Box. Specifications TNCN

Inductive slot sensor

Micro Motion 3098 Gas Specific Gravity Meter

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Transcription:

/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected, electrical components with a moving iron instrument of the accuracy class 2.5. Integrated in enclosures with the type of protection "Ex e", they are used to measure and indicate current and voltage values. The externally adjustable red pointer of the device allows a rapid measurement comparison. The current transformer (CT) versions (1 A and 5 A) allow a rapid and easy measurement range assignment on site due to the scale plate which can be slid in from the side. ATEX / IECEx Class I (NEC 505) (NEC 506) Class I Class II Class III Zone 0 1 2 20 21 22 0 1 2 20 21 22 Division 1 2 1 2 1 2 8402, 8403, 8404: 8405: x x 8403, 8404: x x x 8405: x WebCode 8402A Control Devices /1

/, 8403, 8405, 8404 Selection Table Description Overload scale Measuring range Order number Weight without 1... 20 ma resp. 4... 20 ma, for connection to certified intrinsically circuits only kg 8402/5 0.222 for Ex i circuits,,, 48 x 48 mm, 02414E00 01841E00 01842E00 01843E00 with scale for CT for CT with scale 2 times 0... 20 / 40 ma 8403/2-0,02/0,04-. 0.218 4... 20 / 40 ma 8403/2-0,02/0,04-. 0.220 2 times 4... 20 / 40 ma 8403/2-100%/200% 0.218 0... 1 / 2 A 8403/2-1/2 0.216 0... 4 / 8 A 8403/2-4/8 0.222 0... 10 / 20 A 8403/2-10/20 0.222 0... 15 / 30 A 8403/2-15/30 0.222 0... 25 / 50 A 8403/2-25/50 0.264 2 or 5 times sek. 1 A 8403/2-1 0.216 sek. 5 A 8403/2-5 0.216 2 times 0... 20 / 40 ma 8405/2-0,02/0,04-. 0.122 0... 1 / 2 A 8405/2-1/2 0.124 0... 4 / 8 A 8405/2-4/8 0.118 0... 10 / 20 A 8405/2-10/20 0.120 0... 15 / 30 A 8405/2-15/30 0.120 2 or 5 times 1 A 8405/2-1 0.125 5 A 8405/2-5 0.125 without 0... 10 V 8404/2-10 0.216 0... 100 V 8404/2-100 0.216 0... 150 V 8404/2-150 0.216 0... 250 V 8404/2-250 0.274 0... 500 V 8404/2-500 0.216 Bezel á 64 mm (for ammeter ) Bezel á 72 mm (for ammeter and voltmeter ) 8603A0740-11-0 0.500 8603A0145-21-0 0.025 Bezel Note 01845E00 * Please order scales separately. Further measuring ranges or scales on request. /2 Control Devices

/, 8403, 8405, 8404 Explosion Protection Ex i Global (IECEx) Gas IECEx PTB 06.0006 IECEx PTB 06.0017 U IECEx PTB 06.0017 U IECEx PTB 06.0017 U Ex ib IIC T6 Europe (ATEX) Gas PTB 98 ATEX 2101 PTB 01 ATEX 2158 U PTB 01 ATEX 2158 U PTB 01 ATEX 2158 U E II 2 G Ex ib IIC T6 E II 2 G Ex e II E II 2 G Ex e II E II 2 G Ex e II Certificates and approvals Certificates Technical Data Electrical data Canada (CSA), Russia (CTB), Canada (UL, CSA), USA (UL, FM), Ex i Isolating voltage 690 V 690 V 690 V Type of current AC 15... 100 Hz, AC 15... 100 Hz, DC calibration DC calibration AC 15... 100 Hz, DC calibration Power input max. 0.43 W max. 0.43 W max. 2,1 VA Max. short circuit current max. 150 ma Internal resistance ~ 2.93 Ω Internal inductance 68.5 mh Internal capacitance ~ 0 Ambient conditions Ambient temperature -20...+40 C Mechanical data Ex i Enclosure material Polyamide - polyester Polyamide - polyester Polyamide - polyester Polyamide - polyester Connection cross-section Finely stranded 2.5 mm 2 2.5 mm 2 2.5 mm 2 Solid 4.0 mm 4.0 mm 4.0 mm Assembly / Installation Mounting on TS35 rail Movement Ex i Movement Moving coil instrument Moving iron Moving iron Moving iron Accuracy Class 1.5 Class 2.5 Class 2.5 Class 2.5 Scale 0-100 linear,, Length 40 mm Overload capacity 2 x I N 25 sec 50 x I N 1 sec Related to the measuring range end value 2 x I N 25 sec 50 x I N 1 sec Related to the measuring range end value 1,2 times continuous 2 times 60 sec Bezel Ex i Material Glass - polyester Glass - polyester Glass - polyester Glass - polyester Degree of protection IP66 IP66 IP66 IP66 Gaskets Neoprene Neoprene Neoprene Neoprene Impact strength ) 7 J ) 7 J ) 7 J ) 7 J Sizes á 72 mm á 72 mm á 64 mm á 72 mm Control Devices /3

/, 8403, 8405, 8404 Accessories and Spare Parts Designation Figure Description Art. no. Weight Push-in scales for the 8405 series and the 8403 series 05062E00 For the 8405 series and the 8403 series Measuring range - double overload 0 A... 1 A 5 A 10 A 15 A 20 A 25 A 30 A 40 A 50 A 60 A 75 A 100 A 150 A 200 A 300 A 500 A Specify measuring range kg - - 05062E00 For the 8405 series and the 8403 series Measuring range - quintuple overload 0 A... 1 A 5 A 10 A 15 A 20 A 25 A 30 A 40 A 50 A 60 A 75 A 100 A 150 A 200 A 250 A 300 A 500 A Specify measuring range - - Assembly accessories For 8405 series To engage on TS 35 mounting rail 130954 0.022 05615E00 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 53 A 48 57 48 Bezel assembly code 740 for ammeter 04071E00 04087E00 04490E00 Slide -in scale for ammeter with CT /4 Control Devices

/, 8403, 8405, 8404 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Bezel assembly code 145 for ammeter and voltmeter 04576E00 03348E00 04492E00 Slide-in scale for ammeter with CT We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. 04593E00 Control Devices /5