Operating instructions Capacitive sensors



Similar documents
Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

Operating instructions Optical distance sensor O1D100 O1D / / 2012

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Operating instructions. AS-i Profibus gateway AC1411 / AC /00 04/2014

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Electronic Pressure Switch EDS 300

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Inductive sensor NI10-M18-Y1X-H1141

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Proximity Switches RS (Reed Switch)

Operating instructions. Monitor FR-1 / FR-1N / / 2011

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Electronic Pressure Switch EDS 3000

Technical Data. Dimensions

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

BOS 73K... BOS 74K...

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

Safety technique. Emergency stop module BO 5988 safemaster

Inductive Proximity Sensors

Magnetic Proximity Switches Series CST - CSV and CSH

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

How To Read A Pipe From A Sensor

photoelectric highlights

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Capacitive Prox E2K-X

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Technical Data. Dimensions

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Infrarot-Bewegungsmelder IP44

Capacitive sensors. Versatile, contactless, durable Edition 2012/2013

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Adjustment functions for both span and shift have been incorporated

Original instructions Tina 3A/Aps Adaptor unit

New XUY roller sensors

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Drayton Digistat +2RF/+3RF

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

WEB log. Device connection plans

Tina 2A/B Adaptor unit

ACS-30-EU-EMDR-10-MOD

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Installation instructions CAN/RS232-USB interface CANfox EC / / 2010

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

HERZ-Thermal Actuators

ENGLISH USER MANUAL. Victron Atlas Combi 12/450. victron energie. user manual 5

96 Variants. The GlobalProx range increases in popularity. 12 PNP Normally-open 12 PNP Normally-closed 12 NPN Normally-open 12 NPN Normally-closed

Product and functional description

WEB log. Device connection plans

LUT Luminescence scanners: Seeing what no-one else can

Cross-beam scanning system to detect slim objects. 100 mm in

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Inductive proximity sensors IM 12 series, sensing range 2 / 4 mm DC 3-wire, metal housing

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

MULTI-BEAM LS10 Light Screen System

SVR 12/24V and SVR Akku 12V Installation instructions

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

Voltage Regulator SPAU 341 C. Product Guide

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Conductive Level Switch FK 2 Technical Data:

Inductive sensors. Compact, fast, reliable. Edition 2013

U-shaped Micro Photoelectric Sensor

Color Mark Sensor with Red or Green LED E3S-VS

Electric Landing Gear controllers and sequencer LGC12 / LGC 13C

POINTS POSITION INDICATOR PPI4

1 General information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Modular I/O System Analog and Digital Interface Modules

PRODUCT PROFILE FEATURES

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Multi-Protocol decoder with Load regulation

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Fitting/Installation Guide - UNIVERSAL

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

THE INPUT/OUTPUT SYSTEM. Key Points

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Malibu Monte Carlo El Camino

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

G670 Intermittent Pilot Ignition Controls

Transcription:

Operating instructions Capacitive sensors UK 700 / 00 0 / 009

Contents Safety instructions Functions and features Installation. Notes on flush and non-flush installation Electrical connection. Wiring. Programming 6. Type KI (with connector) 6.. Programming via the link in the connector 6.. Programming via wiring (KGE - DC PNP/NPN) 6. Type KDE - two-wire technology 6.. Programming via wiring (KDE - AC/DC PNP/NPN) 6. Type KDE - three-wire technology 7.. Programming via wiring (KDE - DC PNP/NPN) 7.6 Type KIE / KGE 8.6. Programming via the wire link 8 Operating and display elements 8. Example type KB 8 6 Settings 9 6. Sensing range 9 7 Operation 9 8 Maintenance, repair, disposal 9 9 Definitions 9

Preliminary note An instruction is indicated by " ": Example: Check whether the unit operates correctly. A reaction to the action is indicated by ">": Example: > Yellow ED lights. Important note Non-compliance can result in malfunctions or interference. Information Supplementary note. UK Safety instructions Please read the product description prior to set-up of the unit. Ensure that the product is suitable for your application without any restrictions. The unit conforms to the relevant regulations and EC directives. Improper or non-intended use may lead to malfunctions of the unit or to unwanted effects in your application. That is why installation, electrical connection, set-up, operation and maintenance of the unit must only be carried out by qualified personnel authorised by the machine operator.

Functions and features The capacitive sensor detects without contact metals, almost all plastics, glass, ceramics, wood, paper, oils, greases, water and all hydrous materials and indicates their presence by providing a switched signal. Installation. Notes on flush and non-flush installation In case of flush installation of non-flush units the sensor properties change and the sensor can remain permanently switched (loss of function). Observe the free space around the sensing face. : flush : non-flush S n : nominal sensing range (see data sheet) d: unit diameter Observe the minimum distances when installing several sensors of the same type. S n : nominal sensing range (see data sheet) d: unit diameter

Observe the minimum distance when installing the type KD : sensor type KD (only non-flush installation) UK The distances need to be determined by the user in his application. Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Disconnect power. Connect the sensor according to the indications on the type label. Note: use a miniature fuse according to the technical data sheet, if specified. Recommendation: check the safe functioning of the unit after a short circuit.. Wiring -wire technology -wire technology : : : miniature fuse (for AC units) negative switching positive switching

. Programming. Type KI (with connector).. Programming via the link in the connector : : programmed as normally open (factory setting) programmed as normally closed.. Programming via wiring (KGE - DC PNP/NPN) / / / /. Type KDE - two-wire technology.. Programming via wiring (KDE - AC/DC PNP/NPN) AC; DC NPN N AC; DC NPN N DC PNP DC PNP 6

. Type KDE - three-wire technology.. Programming via wiring (KDE - DC PNP/NPN) NPN NPN UK PNP PNP BN BK BU Core colours of ifm sockets: BN (brown), BU (blue), BK (black). 7

.6 Type KIE / KGE.6. Programming via the wire link : programmed as normally open (wire link closed, factory setting) : programmed as normally closed (wire link open) Use an appropriate tool to disconnect the wire link. Operating and display elements. Example type KB : : ED potentiometer 8

6 Settings 6. Sensing range Set the sensing range via the potentiometer using the enclosed screwdriver. : : 7 increase the sensing range reduce the sensing range Operation Check whether the unit operates correctly. Bring about a sensor response by taking suitable measures. Display by EDs: ED yellow out: switching output disabled ED yellow on switching output enabled UK 8 Maintenance, repair, disposal The operation of the unit is maintenance-free. To ensure a correct function: keep the sensing face and a clear space, if any, free from deposits and foreign bodies. It is not possible to repair the unit. After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations. 9 Definitions Active zone Area above the sensing face in which the sensor reacts to the approach of the target. 9

Output function Normally open: object within the active zone - output switched. Normally closed: object within the active zone - output blocked. Programmable: choice between normally closed or normally open. Positive switching: positive output signal (to -). Negative switching: negative output signal (to ). Power-on delay time The time the sensor needs to be ready for operation after application of the operating voltage (in the millisecond range). Hysteresis Difference between the switch-on and the switch-off point. eakage current Current for the internal supply of -wire units, also flows through the load when the output is blocked. Current consumption Current for the internal supply of -wire DC units. Switch point drift Shifting of the switch point owing to changes of the operating conditions (e.g. temperature, pressure, air humidity). Short-circuit protection ifm sensors which are protected against excessive current by means of a pulsed short-circuit protection. The inrush current of incandescent lamps, electronic relays and low resistance loads may cause this protection to cut in and turn the sensor off! Operating voltage The voltage range in which the sensor functions safely. A stabilised and smoothed direct voltage should be used! Take into account residual ripple! Technical data and further information at www.ifm.com Select your country Data sheet direct: 0