Circuit Breaker Accessory



Similar documents
Medium voltage VCP-W MR2 (integral racking)

C3306 LOCKOUT/TAGOUT FOR AUTHORIZED EMPLOYEES. Leader s Guide. 2005, CLMI Training

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

LOCKOUT/TAGOUT (LOTO) SAFETY PROGRAM

WEEKLY SAFETY MEETING All Euramax Subsidiaries LOCKOUT / TAGOUT. Safety Meeting Contents. Meeting Notice. Leaders Guide.

LOCKOUT/TAGOUT PROGRAM ENERGY CONTROL PLAN


Instructions For SF 6 Refill Kit

ABR Brake Rectifier Instruction Manual

BWC Division of Safety and Hygiene

HealthStream Regulatory Script

INSTRUCTIONS FOR MAGNUM DS TRIP UNIT TESTING USING TEST KIT SYLES 140D481G02R, 140D481G02RR, 140D481G03 AND 140D481G04

Circuit Electrical Testing

KeContact P20 User manual

3088 Lockout-Tagout Training Program Course Outline

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

Lockout - Tagout Program

Model 1756 Test Lead Kit

MIGRATION HEIGHT-ADJUSTABLE DESKS. Troubleshooting Guide

What s up with Arc Flash?

LITHIUM BALANCE CHARGER

Arc Fault Circuit Interrupters Frequently Asked Questions

Operation Manual. Plasma torch height controller. Model: Compact THC Controller 150

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR THE CONTROL OF HAZARDOUS ENERGY (LOCKOUT / TAGOUT) SECTION: 2400

Engineering innovation

Validity 1. Installation 2 SIMATIC. WinCC flexible Tag simulator Update 1. Readme

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

*.ppt 11/2/ :48 PM 1

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Energy Control Lockout/Tagout

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Performing an automated installation

CoolWave r 2 Phase Control Board and Cable Replacement Kits

Electronically Controlled Air Suspension (ECAS) for Trucks

Operation Manual. Model : Compact THC Controller SD. ( Step / Dir PID generator) A new generation height controller of plasma torach

Operating Manual Color Changing Fountains

October Safety Subject

AUTOMATIC SLIDING DOOR

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Lockout / Tagout Program

Bypass transfer switch mechanisms

BroadBand PowerShield. User Manual

Help protect your home, possessions and family.

3M Wrist Strap and Footwear Tester 740. User s Guide

Instructions & Safety Information Models A220-20D and A220-20L Version 2

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

Determining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

Square D Clipsal C-Bus Network Analyzer

Zenith Controls ISO R-1000C 5/99

Installation Instructions for EHD, EDB, EDS, ED, EDH, EDC, FDB, FD, HFD, FDC, HFDDC Circuit Breakers and Molded Case Switches

Sunny Boy Accessories SMA POWER BALANCER

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

QUICK PROBLEM SOLVING GUIDE

Department of Environmental Health & Safety. Lock Out/Tag Out Program. Date Effective: November 2010

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

Control of Hazardous Energy LOCKOUT/TAGOUT 29 CFR

LOCK-OUT / TAG-OUT SAFETY TRAINING

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Programming and Operating Manual

Control of Hazardous Energy (Lockout / Tagout)

LOCK-OUT/TAG-OUT PROGRAM I. Purpose

Machine Guarding and Operator Safety. Leader Guide and Quiz

Page85. Lock-out Tag-out Plan

, User s Manual

ARC FLASH HAZARD OVERVIEW. Presented August 13, 2015 WWOA Lake Michigan District by Mead & Hunt, Inc.

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

3 WATT LED SPOTLIGHT Model No. SLM

Electrical Shore Connections / Cold Ironing

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

HP 2400/2500 Ultra Light Docking Station User Guide

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

ADM1TE 5/30A DIN rail single phase two wire energy meter

PUSH BUTTON START INSTALLATION MANUAL

Electronic Brake Controller Hayes Brake Controller Company ENERGIZE III P/N # 81741B or ENERGIZE XPC P/N #81745 OPERATION MANUAL

INSTALLATION & SERVICE MANUAL. Display Panel

Westinghouse AB DE-ION Current Limiting Circuit Breakers

Safety Relays ESM/ESM-F

Lockout - Tagout. Control of Hazardous Energy OSHA Standard

Essential Power System Requirements for Next Generation Data Centers

Hand Held Metal Detector

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

ERC-to-MRC JOB TRANSLATOR MANUAL

Tina 2A/B Adaptor unit

DKG 972 Gas Burner Safety Control

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

Dielectric Withstand Testing in a Production Environment

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

Instruction manual for Firstline FCS12000CH

G670 Intermittent Pilot Ignition Controls

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

Owner s Manual & Safety Instructions

Transcription:

s Circuit Breaker Accessory WL Hand-Held Test Set Instruction No.: 11-C-9017-00 REVISION Initial revision. APPLICATION This accessory is intended for use with the following Siemens type WL circuit breakers: Molded Case Circuit Breaker (E231263) Types WLxxD3 xx & WLxxF3xx Low Voltage AC Power Circuit Breaker (E223684) Type WLxxA3xx Low Voltage AC Integrally Fused Power Circuit Breaker (E224354) Type WLFxA3 xx DANGER Hazardous voltages are present during operation. Will cause death, serious personal injury, or equipment/ property damage. Disconnect power before performing service or retrofitting on Low Voltage Switchgear or Low Voltage Power Circuit Breakers, strictly adhering to OSHA lock-out / tag-out policies. Only qualified personnel should work on this equipment, after becoming thoroughly familiar with all warnings, safety notices, and maintenance procedures contained herein and on the devices. The successful and safe operation of this equipment is dependent on proper handling, installation, operation, and maintenance. Only SIEMENS authorized repair or replacement parts shall be used on this equipment. All maintenance / inspection policies dictated here-within must be strictly adhered to. 1 of 2

NOTICE These instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the Purchaser s purposes, the matter should be referred to the local Siemens Sales Office. The contents of this instruction manual shall not become part of or modify any prior or existing agreement, commitment or relationship. The sales contract contains the entire obligations of Siemens. The warranty contained in the contract between the parties is the sole warranty of Siemens. Any statements contained herein do not create new warranties or modify the existing warranty. Designations in this documentation can be trade-marks. Use by third parties for their own purposes violates the owner's rights. 2 of

DANGER Hazardous voltage! Will cause death, serious personal injury, or equipment / property damage. Disconnect power before removing or installing accessories in this equipment. HAND-HELD TEST DEVICE The test device is used to verify the proper operation of the trip unit, the energy transformers and current transformers as well as the tripping solenoid F5 and the measured value display. View (1) LED for operating voltage indication (2) Control buttons (3) 6 LED's to show test results Preparations - OPEN and isolate the circuit breaker - Interrupt external voltage supply for the electronic system, if available CAUTION Nuisance Tripping. May cause unintended opening/closing of downstream equipment, and damage to test equipment. Do not use the Hand-Held Test Unit with the circuit breaker in the CONNECTED position. 1 of 3

DANGER Hazardous voltage! Will cause death, serious personal injury, or equipment / property damage. Disconnect power before removing or installing accessories in this equipment. Connection NOTICE Observe the connecting sequence! Otherwise there may be false tripping and false results. 2 1 3 (1) Test socket at the trip unit (2) 40-pole ribbon cable with plugs (3) Voltage supply (4) Test device Voltage supply The test device is supplied by a 110V AC network. Operation The status test starts immediately after connecting the voltage supply and queries the various components and parameters of the trip unit. If the status test is succesful, the "ETU STATUS" LED will light up. 2 of 3

DANGER Hazardous voltage! Will cause death, serious personal injury, or equipment / property damage. Disconnect power before removing or installing accessories in this equipment. Otherwise, the "ETU STATUS" LED will flash. It is possible to draw conclusions about the fault cause from the way in which it flashes. Indicator Significance 1 x briefly, pause Test device defective 2 x briefly, pause Trip unit defective 4 x briefly, pause 5 x briefly, pause - Parameters not set correctly - Current sensor not properly connected - wrong rating plug - Missing rating plug - Tripping solenoid F5 not properly connected - Solenoid defective The status test can be repeated any time by pressing the "START" button for at least three seconds. It is basically also possible to test an trip unit that is already activated, i.e. supplied by an external voltage source. However, it must be taken into account that the "ETU STATUS" LED may briefly flash twice when the status test result is displayed even if there have not been any faults. As a precaution, the status test should be repeated without external voltage supply of the trip unit. Testing the current and energy sensors To test the current sensors and energy transducers, press the "START" button. A lit-up LED confirms the proper operation of the corresponding transformer/transducer. If an LED flashes, the corresponding transformer/ transducer is not available, not properly connected or defective. Testing the tripping function - Charge the storage spring by hand - Close To test the tripping function, press one of the buttons "L", "S", "I", "N" or "G". The circuit breaker must trip after the time delay adjusted for the corresponding function. The tripping reason can be inquired through the "QUERY" button at the trip unit. Otherwise, the trip unit doesn't have the corresponding protective function or is defective. Testing the display of the measured values To check the correctness of the measured values displayed, simultaneously press the "I" and "N" keys if the circuit breaker has this feature. A current is successively simulated via the measuring transformers in L1, L2, L3, N and G for 30 sec.. The LED of the respective transformer will flash. The test can be considered successful if current is indicated in the corresponding position. Catalog number Order No. Test device WLTS 3 of 3

s Siemens Energy & Automation, Inc. 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-241-4453 seainfo@sea.siemens.com www.sea.siemens.com/power Printed in USA 2004 Siemens Energy & Automation, Inc. All Rights reserved Siemens is a registered trademark of Siemens AG. Product names mentioned may be Trade-