Gas Touch. Built-in Gas Hobs with Electronic Control and Touch User Interface



Similar documents
INDEPENDENT HOBS WITH HIC ELECTRONIC CONTROL

B/S/H/ Error codes and service programmes PH

INSTRUCTION FOR THE USER

Gas Instantaneous Water Heater

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

DKG 972 Gas Burner Safety Control

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

14. Troubleshooting Guide

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

TWO STAGE GAS BURNERS RIELLO 40 GSD SERIES GS10D 29/ kw GS20D 58/ kw

SERVICE INSTRUCTIONS

Baxi Combi 80e & 105e

PART 11: START-UP PROCEDURES FOR THE INSTALLER

TIG INVERTER INSTRUCTION MANUAL

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Operational Overview and Controls Guide

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.


SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Stove Guard Kit User Manual

Fossil fuel heating equipment

User's Instructions. Alpha HE CB25/33 and HE SY25

GAS LEAKAGE DETECTION & AUTO ON-OFF GAS SYSTEM

Spare Parts List M96A.24SM/B M96A.28SM/B

Instruction manual for Firstline FCS12000CH

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

ONE STAGE GAS BURNERS RIELLO 40 FS SERIES FS kw FS kw FS kw FS kw FS kw

San josé OWNER S MANUAL

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

IMPORTANT SAFETY INFORMATION

DVI 980/982 (Honeywell Nr. S4865) Gas Burner Safety Control

MP-4000 Alarm List (Software version or later)

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Fire Alarm Control Panel. Family. Operating Manual

Designed for multi-injector endurance testing, the

PANASONIC TROUBLE SHOOTING GUIDE

Descriptive Technical Documentation. DTD no

CO2 Alarm. Operation. Application

orlando OWNER S MANUAL

Luft-Heizgeräte 03/2003. Workshop Manual. Water heaters. Thermo Top V. Type Thermo Top V (Petrol) Type Thermo Top V (Diesel)

CARING FOR YOUR WATER HEATER

IMPORTANT SAFETY INFORMATION

ABB i-bus KNX Fan Coil Controller FC/S 1.1

1 General information

Thermo Top - Troubleshooting Tree

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Gas Oven Repair Guide

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

BW-500 BED WEIGHER USER MANUAL

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

GSM HOME SECURITY SYSTEM

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Overheating limit control

E-gas Instant Gas Water Heaters

Continuous Flow Water Heaters

Portable Air Conditioner

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

For installation guide see reverse of book

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

EC450 Power Control System

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

IH E Sigma Island 90

Conventional Fire Detection and Extinguishant Control System Specification

Duct Humidity Transmitter

Technical Support Information No. 113 Revision 2.0 March 2005

HeatSource HS1800 Heater

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

PROCEDURES FOR SELF DIAGNOSTICS

Luna 3 Comfort Troubleshooting Guide June 2008

*.ppt 11/2/ :48 PM 1

User Manual THR840DUK Digital Thermostat

MIGRATION HEIGHT-ADJUSTABLE DESKS. Troubleshooting Guide

Business/Home GSM Alarm System. Installation and User Manual

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

D200+ Auto-Dialler Installation/Operators Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Fused Spur Time Switch

4-Channel Thermometer / Datalogger

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

User Manual. Gas fired condensing wall hung boiler. G.C.N : (12 kw) G.C.N : (18 kw) G.C.N : (24 kw)

BUILT-IN SECURIT GAS HOB

Mikrofill Ethos Condensing combination boiler

MAKE OF AUTOMOBILE: NUMBER : 076/ DATE : Copyright Prins Autogassystemen B.V VERSION NR : B

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SERVICE MANUAL REFRIGERATION

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Transcription:

Gas Touch Built-in Gas Hobs with Electronic Control and Touch User Interface ESSE-N / A.S. February 2005

General Features built-in gas-on-glass hob, 73 x 51 cm tempered glass surface (8 mm thickness) standard Electrolux components: 4 gas burners: 1 rapid / 2 semirapid / 1 auxiliary ignition unit (spark generator) spark plugs flame detector thermocouples 2

General Features Electronic control system (supplier: SIT) Power board Touch-control user interface L.H. user interface controlling 2 L.H. burners R.H. user interface consisting of: user interface controlling 2 R.H. burners main ON/OFF and timer board Main shut-off valve Modulation valves for each burner 3

Safety Features Child lock Automatic shut-off : time-controlled temperature-controlled 4

Battery Kit A kit with a rechargeable battery will be available as a service part, to be fitted in areas with power supply problems The battery offers a backup power supply to bridge a short mains power failure 5

Brands / Models / Countries EHS 740 K pnc 949 750 638 ES cat. II 2H3+ EHS 742 K pnc 949 750 637 GB, IE cat. II 2H3+ EHS 746 K pnc 949 750 639 HU cat. II 2HS3B/P EHS 746 K pnc 949 750 640 CZ, HR, cat. II 2H3+ SI, SK EHS 74 K pnc 949 750 641 SE, TR cat. II 2H3B/P 6

Brands / Models / Countries 79900 G-m pnc 949 750 626 IT, PT cat. II 2H3+ 79901 G-m pnc 949 750 628 FR cat. II 2E+3+ 79902 G-m pnc 949 750 629 BE cat. II 2E+3+ 79903 G-m pnc 949 750 627 GB, IE cat. II 2H3+ 79904 G-m pnc 949 750 631 NL cat. II 2L3B/P 79905 G-m pnc 949 750 630 DK, NO cat. II 2H3B/P 7

Brands / Models / Countries ZGG 742 EX pnc 949 750 636 GB, IE cat. II 2H3+ ZGG 743 EX pnc 949 750 647 BE cat. II 2E+3+ 8

Brands / Models / Countries TGE 7096 N pnc 949 750 634 FR cat. II 2E+3+ 9

Brands / Models / Countries PVN 74 XE pnc 949 750 632 IT cat. II 2H3+ 10

Aesthetics AEG-Electrolux 11

Aesthetics : Electrolux, Zanussi, Rex-Electrolux 12

Aesthetics : Arthur Martin Electrolux 13

Countries / Gas Categories II 2H3+ Countries: CZ, ES, GB, HR, IE, IT, PT, SI, SK 2H G20 at 20 mbar 3+ G30 at 28-30 mbar or G31 at 37 mbar 14

Countries / Gas Categories II 2E+3+ Countries: BE, FR 2E+ G20 at 20 mbar or G25 at 25 mbar 3+ G30 at 28-30 mbar or G31 at 37 mbar 15

Countries / Gas Categories II 2H3B/P Countries: SE, NO, DK, TR 2H G20 at 20 mbar 3B/P G30 or G31 at 30 mbar 16

Countries / Gas Categories II 2L3B/P Countries: NL 2L G25 at 25 mbar 3B/P G30 or G31 at 30 mbar 17

Countries / Gas Categories II 2HS3B/P Countries: HU 2HS G20 at 25 mbar or G25.1 at 25 mbar 3B/P G30 or G31 at 30 mbar 18

Test Gasses for Normal Operation Gasses indicated on rating labels and in specifications are test gasses for normal operation in accordance with EN 437 2nd Family : natural gas Group H: G20 = CH 4 100% Group L: G25 = CH 4 86% + N 2 14% Group S: G25.1 = CH 4 86% + CO 2 14% (only Hungary) 3rd Family : LPG Group B: G30 = n-c 4 H 10 50%, i-c 4 H 10 50% Group P: G31 = C 3 H 8 100% Real gasses will be slightly different 19

Gasses CH 4 methane n-c 4 H 10 butane i-c 4 H 10 isobutane C 3 H 8 propane CO 2 carbon dioxide N 2 nitrogen 20

Hob Top 21

Component Layout Main Control & Power Board Main Shutoff Valve Mains Terminal Box Modulation Valves Ignition Unit Main Earth Spark Plugs Thermocouples R.H. User Interface: ON / OFF + Timer L.H. User Interface R.H. Burner UI 22

Schematic Layout 23

Gas Touch Wiring 1 With EMC Filter 24

Gas Touch Wiring 2 Without EMC Filter 25

Gas Touch Wiring Initial production wiring will have an EMC filter between terminal box and main board Main board will be modified by mid-2005 for RoHS compliance; this modified board will also comply with EMC regulations without the need of a filter (to be confirmed) The allowed leak current will not be exceeded if this board is used as service replacement on an older hob having the filter 26

Gas Control Schematic 27

Power Board to igniter from mains power supply to main shut-off valve 2x white to modulation valves 2x white: shut-off valve 5x grey: linear step motor to thermocouples to user interface serial PC interface (not used in service) 28

User Interface L.H. 29

User Interface R.H. 30

Main Shut-off Valve SOLENOID VALVE TERMINALS SOLENOID 12 Vdc 60 ohms (at 20 C) GAS OUTLET GAS INLET 31

Modulation Valve MODULATOR CONNECTOR SOLENOID VALVE TERMINALS SOLENOID 12 Vdc / 87 ohms LINEAR STEP ACTUATOR 12 Vdc 158 ohms per phase GAS OUTLET GAS INLET 32

Modulation Valve SHUT-OFF VALVE LINEAR STEP ACTUATOR 33

Step Motor 34

Characteristic of Step Actuator Natural Gas 20 mbar 35

Characteristic of Step Actuator LPG 37 mbar 36

Flame Modulation The flame can be set in 6 levels At maximum level, the valve is always fully open The other 5 flame levels are defined for each type of gas by a so-called map stored in the EEPROM This map is a set of 5 step values for the step motor 37

Electrolux Burners Ignition Burner Body Safety thermocouple Main nozzle in primary air chamber 38

Electrolux Burners Burner Crown Burner Lid Burner Body Safety thermocouple 39

Electrolux Burners Primary air from above, not adjustable 40

Burners Variants 41

Burners Variants 42

Electrolux Burners natural gas (H/L) 20 mbar LPG 30 mbar LPG 50 mbar Wok rapid semirapid auxiliary main nozzle H [x 0.01 mm] 146 119 96 70 DKK: main nozzle L [x 0.01 mm] 150 133 106 74 ZO: main nozzle LL [x 0.01 mm] 153 133 106 74 DKK: by-pass nozzle [x 0.01 mm] 44 39 30 25 ZO: by-pass nozzle [x 0.01 mm] 56 40 32 28 ON APPLIANCES ADJUSTABLE TO LPG 30mb ZO: by-pass nozzle [x 0.01 mm] 45 35 28 23 ON APPLIANCES ADJUSTABLE TO LPG 50mb DKK: max. power [kw] 3.8 3 1.9 1 ZO: max. power [kw] 4 3 2 1 DKK: min. power [kw] 0.9 0.55 0.45 0.35 ZO: min. power [kw] 1.2 0.65 0.45 0.33 main nozzle [x 0.01 mm] 98 86 71 50 DKK: by-pass nozzle [x 0.01 mm] 44 39 30 25 ZO: by-pass nozzle [x 0.01 mm] 56 40 32 28 power [kw] 4 2.8 2 1 DKK main nozzle [x 0.01 mm] 88 75 60 43 ZO main nozzle [x 0.01 mm] 92 75 60 43 DKK: by-pass nozzle [x 0.01 mm] 39 31 27 23 ZO: by-pass nozzle [x 0.01 mm] 45 35 28 23 DKK: power [kw] 4 2.8 2 1 ZO: power [kw] 4 3 2 1 burner diameter [mm] lid diameter [mm] gasket diameter [mm] Burner type 130 104 74 58 126 / 46 102 72 55 171 134 126 / 95 126 / 95 43

Installation : Dimensions 44

Installation : Dimensions 45

Installation : Ventilation or 46

Installation : Electrical Connection Cable fitted to appliance : H05 V2V2-F (T90) 3x0.75 mm², without plug Connect appliance to mains supply either with a suitable plug-and-socket connection (UK: 3 Amp fuse) or with a fixed connection; in this case a double pole switch with a minimum gap of 3 mm must be installed between the appliance and the mains supply 47

Installation : Connect to Power Supply An initialization procedure is started after connecting the appliance to the power supply (or after a power reset) All LEDs will illuminate for some seconds, then extinguish again The hob can be switched on now 48

Operation : Switch On Hob Touch the main ON/OFF control for about 3 seconds The power control LED will illuminate, a long beep will sound The hob is ready for use now If no other control is activated within 30 seconds, the hob will be switched off automatically 49

Operation : Switch On Burner Touch the Ignition control of the required burner The 2 outer LEDs of the flame level indicator, and the residual heat LED, will illuminate Within 3 seconds, touch either the Flame Increase or the Flame Decrease Control of that burner 50

Operation : Ignite Burner - High Flame Level If the Flame Increase control is used, the burner will ignite at maximum flame level All 6 flame level LEDs illuminate The power board controls the respective modulation valve, fully opening the gas supply to the burner The ignition device is activated for about 6 seconds 51

Operation : Ignite Burner - Low Flame Level If the Flame Decrease control is used, the burner will ignite at medium flame level 3 flame level LEDs illuminate The power board controls the respective modulation valve, opening the gas supply to the burner The ignition device is activated for about 6 seconds 52

Operation : Select Flame Level By further touching either the Flame Increase or the Flame Decrease control, the flame level can be adjusted as required The flame level LEDs will show the setting 53

Operation : Select Flame Level N.B: Whichever the selected flame level, the modulation valve will be fully open during ignition, and the flame will start burning at maximum level The flame will be reduced to the selected level only after the thermocouple safety device delivers a stable signal 54

Operation : Ignition of Several Burners If ignition is selected for more than 1 burner, these will be ignited sequentially, i.e. the ignition procedure must be finished for one burner before it is started for the next one 55

Operation : Switch Off Burner To switch of one burner, touch the repective Ignition Control 56

Operation : Residual Heat Indicator After switching off the burner, the respective residual heat indicator LED will stay on for about 40 minutes (only timecontrolled) The LED will not light up again after a power reset, even if the burner is still hot 57

Operation : Switch Off Hob To switch off the hob, i.e. all burners and the timer, touch the main ON/OFF control 58

Operation : Lock (Child Lock) Hob is switched OFF Touch Lock control for about 3 seconds, until the associated LED illuminates, and a long beep is heard To switch on the hob, the child lock must be de-activated first, by touching the Lock control again, until LED extinguishes, and long a long beep is heard 59

Operation : Lock (Function Lock) Hob is switched ON, at least one burner functioning Touch Lock control for about 3 seconds, until the associated LED illuminates, and a long beep is heard Flame setting can t be changed, only the OFF control is active To de-activate the lock, touch the Lock control again until LED extinguishes and a long beep is heard, or switch off the hob 60

Ignition Failure Spark generator will attempt ignition for about 6 seconds If ignition is not successful, the gas supply to this burner is interrupted for 3 seconds, after which sparks are again generated for 6 seconds If ignition fails after 3 attempts, the burner will go into safety mode The selected segments of the flame level indicator will flash Fault 01 is shown flashing in timer display for the respective burner (if timer is switched on) 61

Automatic Reignition If the flame is accidentally extinguished, this is detected by the thermocouple, and the main board will close the respective shut-off valve to interrupt the gas flow After 20 seconds, the gas flow is opened again, and the ignition procedure is restarted After 3 unsuccessful attempts, the burner will go into safety mode The selected segments of the flame level indicator and the residual heat indicator will flash Fault 01 is shown flashing in timer display for the respective burner (if timer is switched on) 62

Overheating If the NTC sensor on the main board detects a temperature of 95 C, all functioning burners are switched to minimum flame level If temperature continues to increase, reaching 105 C, the hob is switched off completely, and goes into safety mode Fault 09 is shown flashing in the timer display for all burners (if timer is switched on) 63

Burner Safety Switch Off Any burner will be automatically switched off after 4 hours from the last user intervention (e.g. flame level adjustment) The burner goes into safety mode Fault 10 is shown flashing in timer display for the respective burner (if timer is switched on) 64

Operation : Safety Mode Reset When a safety mode is set on one or more burners, the respective controls cannot be operated for about 60 seconds After this, the burner (or the hob), can be reactivated by simultaneously touching the Flame Increase and the Flame Decrease controls 65

Operation : Switch-off Timer Ignite the required burners If more burners are operating, the switch-off timer can be set for one of them only Repeatedly touch the Timer control, until the LED corresponding to the desired burners illuminates 66

Operation : Switch-off Timer Set the time (up to 99 minutes) by using the Time Increase or Time Decrease controls Countdown will start immediately Countdown of the last minute is in seconds, last 10 secs accompanied by beeps Repeated beeps after switch off - touch Timer control to cancel 67

Operation : Minute Minder If the timer is set when none of the burners are operating, it will act as a minute minder 68

Conversion to Another Gas Change the main nozzle using a 7 mm socket spanner 69

Single Nozzles Marking / Spare Part Numbers auxiliary burner semirapid burner rapid burner natural gas H 20 mbar 70 354 400 413 / 2 96 354 400 412 / 4 119 354 400 404 / 1 natural gas L 25 mbar (NL) 71 354 400 436 / 3 100 354 400 435 / 5 124 354 400 434 / 8 LPG 28-30/37 mbar 50 354 400 071 / 8 71 354 400 036 / 1 86 354 400 432 / 2 70

Kits The following kits can be used for conversion or retrofit: for natural gas H, 20 mbar: 5026 73 42-00 / 9: 1 x 0.70; 2 x 0.96; 2 x 1.19 5027 36 08-00 / 5: 1 x 0.70; 3 x 0.96; 1 x 1.19; 1 x 1.46*; 1 x 1.13** for natural gas L, 25 mbar (NL): 5026 45 43-00 / 5: 1 x 0.71; 3 x 1.00; 1 x 1.24; 1 x 1.33* for LPG, 28-30 / 37 mbar: 5027 36 09-00 / 3: 1 x 0.50; 3 x 0.71; 1 x 0.86; 1 x 0.98* 5026 94 49-00 / 0: 1 x 0.50; 2 x 0.71; 1 x 0.86; 1 x 0.83* **nozzle for 3-crown burner * nozzle for oven burner 71

Setting the Gas Type After changing the nozzles, the gas type must be set in the main board To do this, switch on the hob Switch on the timer and set it to the auxiliary burner (front left) 72

Setting the Gas Type Using the Time Increase control, set timer to 99 73

Setting the Gas Type Using the Time Decrease control, set timer to 80 (or below) 74

Setting the Gas Type Using the Time Increase control, set timer to 83 75

Setting the Gas Type The timer display will now show the current setting, usually n0 (factory setting) If required, change the setting in accordance with instructions If n2 is not defined for the respective model, the hob will not work with this setting (eventually showing fault 01 ) 76

Minimum Flame Adjustment If the flame aspect and the flame stability are not satisfactory, carry out the procedure of Setting the Gas Type, until the setting is shown Ignite the burner to be adjusted - an automatic adjustment will be carried out, in the course of which the burner may repeatedly extinguish an re-ignite During this sequence, a manual adjustment can be done by using the Flame Increase or Flame Decrease controls 77

Flame Adjustment If the minimum flame level (step 1) is manually adjusted, this means that the step value for level 1 is changed The step values for levels 2 to 5 will be shifted accordingly Level 6 remains unchanged (fully open), the flame level being determined only by the inlet pressure and by the size of the nozzle 78

Fault Codes If a fault condition occurs on one burner, this will be shown by flashing flame level LEDs and residual heat LED (N.B.: not always all 7 LEDs will flash, but only those which were illuminated when the fault condition occured) To read the fault code, switch on the timer, and set it to the respective burner: a flashing 2-digit decimal fault code is shown 79

Fault Codes Faults are marked B or S on the following slides B faults affect only individual burners: the affected burner goes into safety mode the fault code is shown in the timer display only when the timer is set to the respective burner the system, and the other burners, remain operative S faults affect the whole system the system, and all burners, are locked the fault code is shown in the timer display for all burners 80

Fault Codes Possible Causes 00 - No error 0 I B No flame after retry Absence of spark Absence of gas supply Incorrect spark Wrong position of burner cap Wrong position of thermocouple Wrong connection of thermocouple Main shut-off valve faulty Burner shut-off valve faulty Wrong gas setting Main board faulty 81

Fault Codes Possible Causes 02 B Solenoid valve feedback fault Wiring to burner shut-off valve faulty Burner shut-off valve faulty Main board faulty 82

Fault Codes Possible Causes 03 B Step motor phase 1 fault 04 B Step motor phase 2 fault 05 B Step motor phase 3 fault 06 B Step motor phase 4 fault 07 B Step motor enable fault For all above: Wiring to step motor faulty Step motor faulty Main board faulty 83

Fault Codes Possible Causes 08 B Generic fault Main board faulty 09 S Temperature out of range NTC on main board detects temperature > 105 C Overheating - wait for cool down (if frequent, check for causes, e.g. excessive use, unfavourable build-in situation) Main board faulty 84

Fault Codes Possible Causes I0 B I I S I2 S Continuous run timeout Timeout exceeded (burner on for more than 4 hours without any user intervention) No fault (normal safety function) Power supply Vpp fault Fault in 12.8 V supply on main board Power supply Vdd fault Fault in 3.3 V supply on main board 85

Fault Codes Possible Causes I3 - Power supply battery Battery discharged or missing (Only when battery backup kit is installed!) I4 B Abnormal thermocouple condition Parasite flame detected by thermocouple Thermocouple faulty Thermocouple wiring faulty Main board faulty 86

Fault Codes Possible Causes I5 S I6 S I7 S I8 S I9 S System locked, fatal fault NTC sensor fault NTC value out of working range (broken / short circuit) Time base ratio fault (time slot monitoring) AD converter fault Data memory fault 20 S Program memory fault / configuration bit fault 87

Fault Codes Possible Causes 2 I S EEPROM memory fault 22 S EEPROM data out of range 23 S Software watchdog fault (time slot monitoring) 24 S Logical monitoring tracing fault all above (15 to 24): Main board faulty 30 S Uninstalled burner 88

Faulty PCB In case a fault of the electronic control is suspected, knowledge of the signal flow between the boards will be helpful to detect the faulty board Communication between the main board and each of the two user interface board is detailed on next slide 89

Communication PB - UI R.H. User Interface Main On/Off Timer Lock L.H. User Interface Fault code Flame presence Off request from clock Residual heat Flame level request Off request Reset request after lockout General off Child/function lock Fault code Flame presence Off request from clock Residual heat Beep request Flame level request Reset request after lockout Mains Supply Main & Power Board NTC to Main Shut-off Valve to Burner Shut-off Valves to Burner Step Actuators to Ignition Unit Thermocouple Signals 90

Service Manual Soon in TDS: Service Manual Publ. No. 599 366 262 91