TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser



Similar documents
Drayton Digistat +2RF/+3RF

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Digistat RF Troubleshooting Procedure

Wireless 7 Day Programmable Room Thermostat

Drayton Digistat +2RF

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

User's Instructions. Alpha HE CB25/33 and HE SY25

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Installation & User Instructions

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Users Instructions BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER

EK908FHL - Thermostat for floor heating

Combi Eco Elite Range. User s Guide and Important Warranty Information

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

Baxi Combi 80e & 105e

User Manual THR840DUK Digital Thermostat

Fused Spur Time Switch

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

IN-OUT Thermometer with Cable Free Sensor and Clock

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

Installation Guide for Hive Active Heating

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

Wireless Indoor/ Outdoor Thermometer

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Combi 24 HE. User s Guide and Important Warranty Information

Wireless Home Security Alarm System AM 500

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler

For installation guide see reverse of book

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

PROGRAMMING & OPERATING INSTRUCTIONS CL5000 AUDIT TRAIL

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

HEAT PUMP PROGRAMMABLE THERMOSTAT

Please read and keep these instructions. Run water through your machine before first use

FG MOISTURE MONITOR Installation & Operation Manual

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

Combi 30 HE. User s Guide and Important Warranty Information

CM927 - User Guide. Description. Features. 7 day Wireless Programmable Room Thermostat with LoT Technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Mini Timer Owner's Manual. Model MT13A

How To Program An Autodialer

Hi-Spec. sustainable solutions under one roof HEATING HOT WATER VENTILATION. Warm Air Heaters. with System E-T & Basic Control USERS INSTRUCTIONS

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

KD-204. Telephone Remote Switch. Operating Instructions

Table of Contents Function Keys of Your RF Remote Control Quick Setup Guide Advanced Features Setup Troubleshooting

WIRELESS HOME ALARM SYSTEM (WHA1)

INFRARED QUARTZ WALL HEATER

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

PR-2500 Portable Receiver. Owner s Manual

Radio Thermostat Clock Part Number: Installation & User Instructions. Suitable for all Ferroli Combination Boilers

CAD-05 Kit GSM Auto Dialer. Owner s Manual

PSPA711a. LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS. Mt. Laurel, New Jersey 08054, USA

B/S/H/ Error codes and service programmes PH

ES-LCD User Control SD Card Location

GeyserWise TSE. thermostat instruction manual. SANS 181 compliant

DAB+ / FM Tuner Model: TU-201

RF Projection Barometer With Remote Thermo Sensor

Model Owner s Manual. Español - P. 19 Français - P. 39

Safety Warnings and Guidelines

Installation instructions. For the competent person. Installation instructions. VRT 350f. VRT 350f GB, IE

GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER

BoilerMate SP. benchmark. user instructions A - C L A S S

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Model 201 Wiegand Touchpad Reader Installation Guide

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

GSM Alarm System User Manual

EDGE 800. quick start manual TOUCHSCREEN GPS-ENABLED BIKE COMPUTER

User Installation Guide

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

RADIO CONTROLLED DIGITAL CLOCK MODELS / 88906

Portable Air Conditioner

Operating instructions

INSTALLING A/C ADAPTER

User Guide. Promax System Condensing System Boiler

Wireless Thermostats 230v and Battery Operated Instruction Manual

The Black Box Push Button Control Box

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Transcription:

FITTING AND OPERATING INSTRUCTIONS FOR DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM General information is given in the users instruction leaflet despatched with the appliance and/or on the lighting instruction plate fitted to the appliance. RECEIVER TRANSMITTER Digistat Optimiser SET? SELECT SIGNAL HEATING ON OVERRIDE 2 1 YES + LEARN MODE CONFORMS TO THE ESSENTIAL REQUIREMENTS OF THE FOLLOWING DIRECTIVES: 89/336/EEC ELECTROMAGNETIC COMPATIBILITY 73/23/EEC LOW VOLTAGE DIRECTIVE THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE

Gas Safety (Installation and Use) Regulations 1988: All gas appliances must be installed by a competent person, in accordance with the above regulations. Failure to install the appliance correctly could lead to prosecution. the manufacturers notes must not be taken, in any way, as overriding statutory obligations. IMPORTANT: Read these instruction carefully in order to get the best from your appliance. WARNING: This appliance must be earthed and protected by a 3A fuse if a 13A plug is used, or, if any other type of plug is used, by a 5A fuse either in the plug or adaptor or at the distribution board. NOTE: The radio signal transmitter used in the Digistat conforms to DTI standard and is licence exempt. TO FIT THE RECEIVER WARNING: Switch off the power supply before starting work. Release the blanking plate by gently pulling the top lug and withdraw it from the front of the facia. Present the receiver to the facia and plug the programmer connector into the four-way connection on the board (Fig. 1). Push the receiver into position ensuring that the lead is not trapped and that the top lug snaps into place. Refit the control panel before switching on the power supply. Programmer connection Fig. 1. ST5 1

COMMISSIONING THE DIGISTAT AND RECEIVER 1. Turn on the power to the appliance/receiver. 2. Push the override button on the receiver once. The green LED should come on and the appliance should run in central heating mode. 3. To enter the learn mode push (and hold) the button marked 1 followed by the button marked 2 (OVERRIDE) and hold both depressed together. The red LED should flash for two seconds then go out signifying that the receiver is in learn mode. Release both buttons. 4. The red and green LED s should now both be on. 5. Take the Digistat (no closer than one meter from receiver.) 6. Slide down the right hand battery drawer of the Digistat, remove the plastic insulator strip and slide drawer back into place. 7. Repeat the same procedure with the left hand battery drawer. The procedure on the right hand drawer must be carried out first. 8. As soon as both battery compartments are slid back into place, the red LED on the receiver should flash for 7 seconds and then go out. The green LED may be ON or OFF depending on the room temperature at the time of commissioning. 9. The Digistat should now display the actual room temperature and the time at 12.00 am midnight. If the unit has been stored in a cold place, it may take time to warm up. 10.If the red LED remains on, slide down both battery drawers on the Digistat, check the battery positions are correct, and once the display has faded, repeat steps 6 to 9. 11.Increase the SET temperature on the Digistat by pressing the + button until a flame symbol appears, in the left hand segment of the display. 12.The red LED on the receiver should flash for 7 seconds. This confirms that the radio signal is being sent and received. After 7 seconds the red LED should go out and the green one come on. 13.Check that the appliance is running in central heating mode. 14.Decrease the SET temperature on the Digistat by pressing the button until the flame symbol disappears. 15.The red LED on the receiver should flash for 7 seconds. After the 7 seconds both the red and green LED s should go out. Check that the appliance has switched off. 16.The Digistat can now be secured to the wall in the desired position. During normal operation the red LED on the receiver will flash for 7 seconds each time a radio signal is received from the Digistat. This will occur approximately every 5 minutes. The green LED on the receiver denotes a call for heat (ON). Once the system has been successfully commissioned, buttons 1 and 2 on the receiver should not be pressed simultaneously, unless a replacement Digistat or receiver is fitted. 2

INSTALLING THE DIGISTAT WARNING: ISOLATE MAINS SUPPLY BEFORE REMOVING ANY EXISTING THERMOSTATS IMPORTANT The Digistat is a battery powered (Four type AA 1.5V alkaline cells, supplied, and replacement must be of the same type) wireless unit, using radio signal technology and DOES NOT require any electrical connections. If the Digistat is being used to replace an existing hard wired thermostat, the wiring to the old thermostat must be made electrically safe and isolated, as it is no longer required. LOCATION Care should be taken to mount the Digistat in a position which is not subjected to direct sunlight or draughts. Preferably it should be mounted on an inside wall, about 1.5m (5ft) above the floor, in a position where it can respond to room temperature but away from the direct influence of radiators or other appliances giving off heat. Minimum wall plate clearances are shown in Fig. 2. It is advisable to carry out the commissioning procedure BEFORE fixing the wallplate, to ensure your chosen location is suitable for transmitting and receiving radio signals. The range of the radio signal is typically 30m, typical house walls have no effect on the signal. FIXING 1. Loosen the securing screw on the bottom of the Digistat and remove the wallplate. 2. Fix the wallplate with securing screw at the bottom directly onto a flat wall. The wall plugs and screws provided must be used. Minimum wall plate clearances are given below (Fig. 2). 3. Note: The Digistat comes pre-set with a temperature range of 5 C to 30 C. If you wish to select the optional range of 16 C to 30 C remove the selector link at the rear of the unit. 4. Plug the Digistat onto the wallplate and tighten the securing screw. DO NOT remove the plastic strips from the battery drawers until you are ready to carry out the commissioning. 50mm minimum clearance Fig. 2. 70mm minimum clearance MAINTENANCE No maintenance is required for the Digistat, apart from battery replacement (Four type AA 1.5V alkaline cells, rechargeable batteries must not be used) 3

PROGRAMMING & OPERATING INSTRUCTIONS Once the system has been commissioned, the unit will display the actual room temperature and the time at somewhere after 12.00 am (midnight). Digistat has an indicator to show when the heating system is ON or OFF, for example if the SET temperature is 20 C and the actual temperature is below 20 C a flame symbol will appear on the display (Fig. 3).This indicates a demand for heat (system will switch ON). During normal operation, the Digistat will display actual room temperature continuously. TO SET THE CLOCK C AM Figure 3 1. Press SET? button. 2. Press YES ( ) button. The hours will flash. Use the + and buttons to set correct hour. 3. Press SET? button again and the minutes will flash, use + and buttons to set correct minute time. 4. Press SET? button, day of week will flash, 1 = Monday, 7 = Sunday, use + and buttons to set correct day. 5. Press SET? button twice to return to normal operating mode. Digistat is supplied with a pre-set programme shown below which can be easily changed to suit your requirements: FACTORY PRE-SET PROGRAMMES Table 1 1 2 3 Setting Time (Mon-Fri) Time (Sat-Sun) Temperature Start of early morning 6.30am 7.00am 21 C Start of day time 8.30am 9.00am 16 C Start of evening 4.30pm 4.00pm 21 C Start of night time 10.30pm 11.00pm 7 C* * 16 C if selector pin removed see INSTALLING THE Digistat TO VIEW OR CHANGE THE PRE-PROGRAMMED TIMES AND TEMPERATURES 6. Press SET? button until display is shown. 7. Press YES ( ) button. You have selected the Monday to Friday part of the programme. 8. Press YES ( ) button again. This tells you that at 6.30am, the heat ing system will control your home at 20 C. If you wish to alter the tem perature use the + and buttons. 9. Press SET? button. The time will now flash. If you wish to alter the switching time use the + and buttons. This will change the switching time in 10 minute steps. 4

10.Press SET? button, this tells you that at 8.30am, the heating system will control your home at 16 C. If you wish to alter this temperature use the + and buttons. 12. Once Mon-Fri have been set, the display will show this. This means do you want to set the times for Monday (1) dif ferently from the rest of the week? If you do, press the Yes ( ) button, and follow the routine as points 9 to 11. 11. Continue to press the SET? button as in 9 & 10 above to advance through the times & temperatures for Mon to Fri. (1-5). If you wish to alter any of the times & temperatures use the + & button, when the one you wish to alter is flashing. 13. Continue to press the SET? button to advance through the week (1-5). When the display is this. press the Yes ( ) button if you wish to view or alter the times for Sat-Sun. (6-7). Repeat steps 9-12 as required. 14.Continue to press SET? button until you return to normal operating mode with a display similar to: OPERATING MODES The Digistat can be operated in one of three modes. 1) Normal Running (all pre-set times and temperatures) 2) Continuous night temperature (useful for low limit temperature protection when on holiday) 3) 1 Continuous DAY 1 preset temperature Use the SELECT button to change the operating mode to suit your requirements, The symbols are positioned on the right hand side of the display. OPTIMUM START The Digistat Optimiser unit features a unique self learning energy saving system by delaying the first start up point when the weather is milder. There is no extra programming required. The self learning software is factory preset and will start to monitor and adjust the boiler start time for the first switching time of the day, as soon as the unit is installed. The delay period can vary between 0-60 minutes depending on; a) The actual room temperature at the first switch time. b) The set temperature of the Digistat Optimiser. c) The stored information on how fast the heating system responded the previous day. The flame symbol provides the operating status as follows; Flame on = heating on No flame = heating off Flashing flame = saving energy (optimum start cycle operating) When the flame is flashing, the optimum start can be overriden by pressing the + button once. This returns the unit to normal operation. IMPORTANT Always set your heating to the time that you would normally want it to start allowing for the coldest weather conditions eg. perhaps one hour before you get out of bed. Optimum start will automatically delay the start time and save you money on milder days. NOTE: There is no delay for the other switch times of the day. There is no delay if the room temperature is 13 C or lower. TEMPERATURE OVERRIDE If at anytime during normal operation, you wish to increase or decrease the set temperature simply use the + or buttons to change to your desired setting. 5 seconds after releasing the + or button the display will revert to showing the actual room temperature. The Digistat will now control the temperature to the override setting until the next programmed switching time, when it will revert to the times and temperatures you have already programmed. NOTE: If the next programmed temperature setting is the same as the present programmed setting, the override temperature will remain in force. 5

ADDITIONAL INFORMATION IMPORTANT: ENSURE THAT THE COMMISSIONING PROCEDURE HAS BEEN CARRIED OUT AS DESCRIBED ABOVE. NORMAL OPERATING MODE Once the Digistat system has been commissioned, there should be little need for any user interface with the receiver. During normal operation the red and green LED s will occasionally be on, and these signify the following: GREEN LED The green LED will be on when there is a demand for heating, and off when there is no demand. RED LED The red LED will flash for 7 seconds, approximately every 5 minutes. This denotes that a radio signal is being received from the Digistat unit. SITUATIONS REQUIRING ATTENTION RED LED CONTINUALLY FLASHING This denotes that the batteries in the Digistat unit are approaching the end of their life (see Battery replacement). RED LED CONTINUALLY ON This denotes that the receiver has been unable to receive a radio signal from the Digistat unit. This may be caused by the batteries being dead (see Battery replacement) or some temporary interference with the radio signal. To re-send and test the signal, go to the Digistat unit. If the flame signal is visible on the display, press the button until it disappears. If the flame symbol is not visible, press the + button until it appears. If the radio signal has been successfully transmitted and received, the red LED will flash for seven seconds then go off. If the red LED is still on, learn mode may have been selected by accident. To correct, open both Digistat battery drawers and wait for the display to fade, close the right hand drawer followed by the left and re-programme the Digistat with your desired time and temperature settings. If the red LED is still on, there may be a poor battery connection inside a drawer (perhaps due to a leaking battery). Clean contacts. If problem is not solved the fault will require the attention of a heating engineer/electrician. MANUAL OVERRIDE In a fault situation, the heating can be manually switched on and off by using the OVERRIDE button on the receiver, even though the red LED will stay on until a satisfactory signal is reinstated. Once the receiver receives a satisfactory signal again, it will automatically reset itself for normal operation. 6

BATTERY REPLACEMENT Thirty days before the batteries need replacing, a battery symbol will flash in the right hand side of the display. (Fig. 4). This signifies that 4 x 1.5v type C + AA alkaline batteries will be needed to replace the old ones. If battery replacement is carried out in this condition the settings will only be held in the memory for a maximum of one minute, after which reprogramming may be necessary. Figure 4 Important To avoid the possibility of having to reprogramme the switching times and + temperatures, it is advisable to wait until the flashing battery display changes to a continuous battery only display (after 30 days). (Fig. 5). In this condition the unit will be OFF but your programmed settings will be held in the memory for a number of weeks. The battery compartment can now be left opened, to replace the batteries for approximately one hour. If Figure 5 the compartment is left opened for longer the unit will revert to the factory preset times and temperatures. It may be necessary to reset the correct time of day after changing the batteries. The battery compartment is situated at the bottom of the unit (press to unlatch and slide down). Ensure new batteries are positioned correctly. Close right hand compartment first. HELPFUL HINTS 1. FIRST/LAST SET TIMES The Day 1 setting 1 cannot be programmed before 12.00 am. The night setting can be programmed at whatever time you require, even after 12.00 am (midnight) so long as it is not more than 23 hours 50 minutes after the Day 1 setting. 2. PART OR FULL DAY OMISSION If during programming the Digistat one of the symbols on the left hand side of the screen starts to flash, this indicates that two or more of the switching times have been set to the same time. This facility enables you to omit one or more of the switching periods. When one or more of the switching times are programmed together the later setting takes precedent. For example, if all four switching times were set together the Digistat would control continuously at the fourth (night) temperature setting. 3. PROGRAMME SEQUENCE The Digistat will not allow you to program the switched periods out of sequence but will hold the times together as stated above. 4. RESET If at any time during the programming you get confused and would like to start the procedure from the beginning press the SELECT and buttons at the same time and hold for two seconds. This resets the Digistat to the factory pre-set times and temperatures (Table 1). 5. SELF REVERT If during programming no button is pressed for between 1 and 2 minutes the Digistat will revert automatically to its normal operating mode. HOT WATER SUPPLY Hot water is available whenever a tap or shower is turned on. The supply of hot water takes priority over the delivery of heat to the central heating system for the period that the hot water is required. TEMPERATURE CONTROL The central heating water temperature is controlled by the centre knob on the facia. The domestic hot water temperature is controlled by the right hand knob on the facia up to a pre-set maximum. 7

REPLACEMENT PARTS The receiver and Digistat are available separately for replacements or as a complete system. G.C. No. Part WHS Part No. E90-617 Transmitter Digistat Optimiser 8 716 105 128 0 E89-870 Receiver Digistat (Small) 8 716 105 129 0 8

Worcester Heat Systems Ltd. (Bosch Group), Cotswold Way, Warndon, Worcester WR4 9SW. Telephone: 01905 754624. Fax: 01905 754619. Technical Helpline 08705 266241. www.worcester-bosch.co.uk This booklet is accurate at the date of printing but will be superseded and should be disregarded if specifications and/or appearances are changed in the interests of continued improvement. All goods sold are subject to our official Conditions of Sale, a copy of which may be obtained on application. PUBLICATION 8 716 105 136a 07/02 06490020001