Pressure relief valves Size 6



Similar documents
2/2 and 3/2 Way Size 6 Seat Valves

Pressure Relief Valves SPV, SPVF

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Pressure reducing valve, direct operated, Type ZDR 6 D

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

2-way flow control valve Type 2FRM 6

Chapter 5: Flow Valves

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Electro-hydraulic pressure switches type DG

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

KDG3V-5/7/8, 10 Series

Line rupture protection valves type LB

Hydraulic Control Solutions

Chapter 6: Check Valves

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

3/2- and 2/2-way cartridge valve type BVE

4/2-Way Pneumatic Solenoid Valve

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Richter Twin Piston Quarter-turn Actuators

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Rotary Actuators, NAMUR interface VDI/VDE 3845 & ISO 5211 (ATEX certified) Series ARP

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

3/2 Solenoid Cartridge Valve, Size 6

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

DATA PD RE21.., KX..., Quick Release Valves. Product. Function. Technical Features. Range Overview

Variable Displacement Pump AA10VSO

kymanual or Automatic - it s your Choice

SOLENOID VALVES 3-4 WAY

Valve systems Base plates, according to standard ISO Brochure

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Open center control block in monoblock design MO-40

Flow Control (and Check) Valves FG FCG -01/02/03/06/10. Specifications / Model Number Designation / Others. Min. Metred Flow Capacity

2-way flow control valve with sliding throttle type SB and SQ

Check Valves Valve locator

MHT. Pressure Filters HIGH PRESSURE INLINE FILTER

Pneumatic actuators The Original! Technics of the top class.

9 Control Equipment. Control Button Series 8082

Hydraulic Flow Control Valves

Load-sensing control block in mono and sandwich plate design

Return line filters. Return line filters

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

STAR Linear Bushings and Shafts Supplement RE / Linear Motion and Assembly Technologies

Pneumatic. PXC Limit Switches. Authorised Distributor TTS Valve Technologies Sdn Bhd

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Vacuum Gate Valve DN 100 and DN 150

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

System 8. ü ( System 8

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

3/2-way pneumatic cartridge solenoid valve

15/40/80CN Series Medium Pressure Filters

High Pressure Gear Motors KM 1

3/2-way Solenoid Valve, direct-acting, NC or NO

Electric Rotary Actuator - On/Off or programmable control actuator

1. General. D 7490/1 2/2-way cartridge valve EM 2.2. Operation pressure p max Flow Q max. = 450 bar = 160 lpm. Cartridge valve (see section 2)

Directional seated valves type VP 1

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Hydraulic multidisc Brake H420

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Cooling system components, removing and installing

Unit 24: Applications of Pneumatics and Hydraulics

Vickers. Piston Pumps

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve


Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Series PVP Variable Volume Piston Pumps

Solenoid Operated Directional Valves

Pressure regulating valve with modulating kit, type DRV

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB EDITION 5.

Solenoid Operated Directional Valves

Construction of the Gear Pump KF

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

SISTO-16TWA/HWA/DLU. Type Series Booklet

The cylinder head bolts tightening stages have been updated as listed in Table 1.

Reaction Torque Sensor

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

3/2-way Mini Solenoid Valve

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

Solenoid valves 2/2-way direct-operated Type EV210A

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Transcription:

Pressure relief valves Size 6 direct controlled Interface to DIN 24 340 and ISO 6264 PN [p max. ] = bar 750400.06.0.06 Description (standard units) Design The pressure relief valves of Type D B C 6 are directcontrolled seat valves. Actuation The pressure is set manually by means of a rotary knob. The setting can, if desired, be safeguarded by means of locking (E 0closure) or by means of a lead seal. Line connection and mounting The mounting of the units depends on the line connection and type: Line connection: Subplate Threaded port Plugin design Type code Mounting: On subplate by means of bolts Sealing by means of Orings On equipment rack, etc. by means of bolts Complete unit is screwed into threaded bore Pressure relief valve D B C 6......... 00... O... 2 3 4 5 Actuation: H Manual setting HV Manual setting (lockable) HK Setscrew with cover (can be lead sealed) 2 Line connection: S4 Threaded port flange mounting G /2 internal threaded to ISO 228/ C4 Threaded port controlpanel installation G /2 internal threaded to ISO 228/ E Plugin design G Subplate, interface to DIN 24 340 and ISO 6264 3 Pressure 50 up to 50 bar setting range: 70 up to 00 bar 80 up to 20 bar 90 up to 35 bar 9 up to bar 4 Engineering version: 5 Sealing material: O Perbunan V Viton Features High flow rating Insensitive to vibration Suitable for use as remote pilot valve Subplate P S 6 G... 00... O O 2 Line connection: 2 G /4 (internal threaded 3 G 3/8 to ISO 228/) 2 Engineering version: 2 HERION Systemtechnik GmbH Untere Talstraße 65 D7263 Weil der StadtMerklingen Tel.: +49 (0) 70 33/30 80 Fax: +49 (0) 70 33/30 80 www.herionsystemtechnik.de info@herionsystemtechnik.de

Parameters to VDI 3276 Type designation D B C 6..S4.. D B C 6..C4.. D B C 6..E.. D B C 6..G.. General parameters Designation Symbol Pressure relief valve Design Seat valve, directcontrolled Type of mounting Flange Switch board Plugin design Flange installation Line connection Thread Subplate Mounting position Optional Flow direction From P to T Actuation By hand Weight [kg] 2.4 3.0 0.7 2 Weight of subplate [kg] 0.7 Ambient temperature range ϑ u [ C] 20 to +50 Size NG 6 Hydraulic parameters Operating pressure range p e max. [bar] up to Adjustable pressure range p v [bar] p v min.: see characteristic curve p v max.: Pressure stage: 50: 50 Pressure stage: 70: 00 Pressure stage: 80: 20 Pressure stage: 90: 35 Pressure stage: 9: Pressure fluid temperature ϑ m max. [ C] +70 Viscosity range ν [mm 2 /s] 2 to 500 Flow Q [l/min] See characteristic curve Characteristic curves p v min. = smallest adjustable pressure under which valve remains closed by pressure spring Q = 0 (l/min). 2 Subject to alteration 750400.06.0.06

Ordering The units are designated by their type number. The composition of this number can be drawn from the type code. The standard versions are listed in the type survey. When ordering any of the standard versions, please state type number as well as catalog number to preclude possible misinterpretations. When inquiring about or ordering units not listed in our type survey of this publication, the type number made up by you by means of the type code, however, will do. The corresponding catalog number will then be stated in our confirmation of order. Units with flanged connection are delivered complete with mounting bolts and Orings. The subplate must be ordered separately. Example of order Wanted: Pressure relief valve size 6 with threaded port for switch board installation, with manual setting, setting pressure max. 35 bar Pressure relief valve: Type No.: D B C 6 H C4 90 00 O O Cat. No.: 60467 Type survey (standard versions) Size Q Actuation Line connection [l/min] 6 See Manual setting Threaded connection characteristic Flange mounting curve p v max. [bar] 25 50 00 20 35 50 00 20 35 50 00 20 35 50 00 20 35 Threaded connection Switch board installation Plugin connection Subplate G /4 P S 6 G 2 00 2 O O 06573 Subplate G 3/8 P S 6 G 3 00 2 O O 06583 Type D B C 6 H S4 25 00 O O D B C 6 H S4 50 00 O O D B C 6 H S4 70 00 OO D B C 6 H S4 80 00 OO D B C 6 H S4 90 00 OO D B C 6 H S4 9 00 OO D B C 6 H C4 50 00 OO D B C 6 H C4 70 00 OO D B C 6 H C4 80 00 OO D B C 6 H C4 90 00 OO D B C 6 H C4 9 00 OO D B C 6 H E 50 00 OO D B C 6 H E 70 00 OO D B C 6 H E 80 00 OO D B C 6 H E 90 00 OO D B C 6 H E 9 00 OO D B C 6 H G 50 00 OO D B C 6 H G 70 00 OO D B C 6 H G 80 00 OO D B C 6 H G 90 00 OO D B C 6 H C4 9 00 OO Cat. No. 604578 60498 60499 60420 60466 604407 604202 604203 604204 60467 auf Anfrage 60492 60493 60494 60464 604473 604443 604444 604445 604439 60530 Dimensional drawings D B C 6 H S4... D B C 6 HV S4... D B C 6 HK S4... 750400.06.0.06 Subject to alteration 3

Dimensional drawings D B C 6 H C4... D B C 6 HV C4... D B C 6 HK C4... D B C 6 H E... Tightening torque 50...60 Nm Mounting bore for D B C 6...E... D B C 6 HV E... D B C 6 HK E... 4 Subject to alteration 750400.06.0.06

Dimensional drawings Pressure relief valve D B C 6 HK G... D B C 6 HV G... D B C 6 H G... Subpalte with hole pattern to DIN 24340C62 and ISO 2664AB034C G /4 Recess for connections in control panel G 3/8 Recess for connections in control panel 750400.06.0.06 Subject to alteration 5

Spare parts drawings D B C 6 H S4... D B C 6 HV... D B C 6 HK... D B C 6 H C4... D B C 6 H G... D B C 6 HV G... D B C 6 HK G... D B C 6 H E... Spare parts (Quanties) Part 2 3 4 5 6 7 8 Designation Oring (9.2 x.8) Usitring (7.4 x 24 x.5) Oring (20.3 x 2.6) Oring (7.6 x.8) Oring (20.3 x.8) Spring pressure stage 50: pressure stage 70: pressure stage 80: pressure stage 90: pressure stage 9: Lock cylinder with key Key Mounting bolts 4 Cylinder bolts (M 5 x 80 DIN 920.9) D B C 6 H S4... D B C 6 H C4... D B C 6 H E... D B C 6 HK S4... D B C 6 HK E... D B C 6 HV S4... D B C 6 HV C4... D B C 6 HV E... D B C 6 H G... D B C 6 HK G... 2 4 D B C 6 HV G... 2 4 Cat. No. 070252 06572 07054 070484 070259 07204 07205 07206 0569442 0720880 056859 066005 0700397 Set of spare parts consists of parts to 5. 6 Subject to alteration 750400.06.0.06