IMR 6000/10../20../30



Similar documents
SYSTEM DESCRIPTION Termination Boards

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Modular I/O System Analog and Digital Interface Modules

Redundancy Module QUINT-DIODE/40

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Power Supplies 3. SDN-P DIN Rail Series

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Quick Connect. quick - simple - efficient.

COMPALARM AP GENERAL MAIN FEATURES

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Cable Plug acc. to DIN EN , Form A

NC-12 Modbus Application

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Safety technique. Emergency stop module BO 5988 safemaster

Preset Counter signo 721

TX OPEN RS232/485 module

Barcode Reader Series BCL 31, BCL 32, BCL 34

PHOENIX CONTACT Features

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

CQM1-SF200/CS1W-SF200

Multifunction devices

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Installation manual. Generator Paralleling Controller GPC multi-line C

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Digital input modules

DOCUMENTATION PD16 CP3-SVE-M75DC-24

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS

Product and functional description

S-series DC to DC Power Supply

Pluggable interface relays CR-P Pcb relays

RM4TG20 three-phase network control relay RM4-T - range V

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Hardware Manual CAN-IB130/PCIe CAN-IB230/PCIe PCIe/104 CAN Interface

3500/62 Process Variable Monitor

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Actuator-Sensor-Interface

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Plug-in relays Mini ISO relays

Repeaters and Mimics Data Sheet

PHOENIX CONTACT - 01/2007

SKR - industry relay

MINI MCR-SL-R-UI(-SP)

Thyristor-controlled power supplies and battery chargers

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Operating Instructions for Plastic Flow Meter. Model: KSK

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

J TB/TW Temperature limiter, temperature monitor

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Data Sheet. Electro-mechanical counters Hengstler 800 series

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

S-series SQ Controller

DLP-PU/E Instruction Manual

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

TECHNICAL DATASHEET Incremental Encoder RI 58-H

GAE953 Electrical Alarm Unit 19" with Indicator

S-series Mass Connection Solutions

Technical Data. back-up time in minutes 100% load % load

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Protect IT MNS Motor Management INSUM. MPU - Multi Purpose Unit. - Catalogue - ABB

+ Incremental interface

SYSTEM 4C. C R H Electronics Design

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Contact expansion modules

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

RY2 miniature industrial relays

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

CompactLogix Power Supplies Specifications

Intersection Preassembled 19-inch Rack

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

48 SERIES Relay interface modules 10 A

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Transcription:

IMR 6000/10../20../30 System frame Component of the MMS 6000 Machine Monitoring System Applications: Slots for adaptation of the signal processing periphery (monitors, logic cards and interface cards) External connection of the periphery via spring cage and screw connection plugs System frame configuration (depen ding on the version) by hardware via bridges or via Dip switches Build up of RS485 bus lines for integration and configuration of the monitors with the system frames Generation of master key signals by a key monitor at the 1st monitor slot (not at IMR 6000/20) The system frames IMR 6000/10../20../30 are developed for general use in industrial applications, where reliable adaptations between electronic devices and plant devices are necessary. The system frames IMR 6000/10,../20,../30 are components of the epro MMS 6000 machine monitoring system. They consist of a 19 card frame and comprise the following card slots at the front side: 8 10 Monitor slots (depending on the IMR type) for monitors of the MMS 6000 series 2 4 slots (depending on the IMR type) for adaptation of one or more logic cards e.g. MMS 6740 1 slot for adaptation of an interface With the system frames IMR 6000/10,../20,../30, an appropriate adaptation of the signal processing periphery like: alarm signals error signals The first monitor slot at the system frames IMR6000/10 and IMR6000/30 offers the possibility to imply a key monitor (MMS 6310 or MMS 6312) and to relay these key signals to other monitors via the system frame or external connections. The rear of the system frames IMR 6000/10,../20,../30 serve the purpose of: signal supply signal output for further processing parameterization of the system frame connection results external signals can be realized and processed to feed in and spend out all relevant signals. The connection to the external frame is made by spring cage or screw connection plugs. If neccessary, it is possible to build up several RS485 bus lines within one system frame by the integration of a corresponding interface card. The appropriate parameterization does take place via external connections and/or via the configuration of the regarding Dip switches. The system frames IMR 6000/10,../20,../30 offer substantial saving potential with the wiring complexity. Page 1 of 6

Technical Data: Machine Monitoring Systems Data to the special versions of the system frameworks, you can find in the appropriate sections of this data sheet. Data and configuration references to the monitors, logic and interface cards please find in the relevant data sheets.! These system frameworks have two separated power supply, because they offer the possibility to fulfill the NEC guide lines of Low Voltage Limited Energy. A max. supply voltage of 24VDC and a max. input current of 4A per supply result in a maximum Power of < 100VA per supply. With a limitation of the supply voltage and current to this limit, the NEC guide lines of Low Voltage Limited Energy (LVLE) are generally complied. Ambient conditions: application class: KTF according to DIN 40 040 ambient temperature: reference temperature: +25 C / +77 F nominal use range: 0... +65 C / 32... +167 F temperature range for storing and transport: 30... +85 C / 22... 185 F Configuration For the stand alone operations of the system frames IMR 6000/10,../20,../30 no software configuration is necessary. Dimensions allowed relative humidity: 5...95%, not condensing permissible vibration: regarding to IEC 68 2, Part 29 vibration range: peak value of acceleration 98 m/s 2 / 3858.3 in/s 2 vibration acceleration: nominal shock duration: 16ms The parametrization of the system frames must be realized in terms of hardware via bridges, and Dip switches at the rear of the corresponding system frame. permissible shock load: regarding IEC 68 2, Part 29 peak value of the acceleration: 98 m/s 2 / 3858.3 in/s 2 frame shock duration: nominal impact load: 16 ms System of protection: IP 00, open design regarding DIN 40 050 EMC: regarding EN50 081 1 / EN50 082 2 References to the monitor configuration please find in the data sheets and the operating instructions of the appropriate monitors and the associated parameterization software. (The allocation of the components in the system frame is version dependent.) top view 437 mm / 17.2 in 214 mm / 8.4 in 482 mm / 19.0 in 132 mm / 5.2 in front view 180 mm / 7.1 in Page 2 of 6

IMR 6000/10 Machine Monitoring Systems Slots for adaption of the signal processing periphery: monitors: 10. x MMS 6xxx * logic card: e.g. MMS 6740 interface card: e.g. MMS 6824 External connection of the periphery via spring cage and screw connection plugs System frame configuration via hardware bridges and parameterization of the Dip switches. Build up and configuration of the RS485 bus linies for connection and intergration of all monitors Generation of master key signals by a key monitor at the 1st monitor slot * only: MMS 6110, MMS 6120, MMS 6125, MMS 6140, MMS 6210, MMS 6220, MMS 6310, MMS 6312, MMS 6410 The system frame IMR 6000/10 comprises the following card slots at the front side: 10 slots for monitors of the MMS 6000 series * 2 slots for adaptation of one logic card e.g. MMS 6740 1 slot for connection of an interface The following monitors are supported by the system frame IMR 6000/10 with their basic functions: MMS 6110, MMS 6120, MMS 6125 MMS 6140, MMS 6210, MMS 6220 MMS 6310, MMS 6312, MMS 6410 Technical Data: voltage supply: Two redundant, diode decoupled inputs, nominal +24V with common ground. voltage input: +24V UN+, +24V UB+ common reference: 0V U, GND permissible voltage range: +18V... +31.2V typical power consumption: < 100 W max. permissible fuse of the input current: 4A (per supply) internal generated galvanically seperated voltage: +24V max. power of the interal generated galvanically seperated voltage: 2W Page 3 of 6 The connection of the external frame is made by 5 and 8 pole spring cage or screw terminal connection plugs (Phoenix). The RS485 bus connections, the respective key connection as well as all channel clear, alert and danger alarms of the monitors are carried out via these plugs. The voltage supply plugs at the rear of the system frame can be made by 5 pole spring cage or screw terminal connection plugs. voltage supply inputs: KFT according DIN 40 040 Accesories: for signal connection and voltage supply spring cage and/or screw connection plugs are required at the rear of the system frame IMR 6000/10. The epro offered spring cage connection plug set (IMR6000/10 NC: 9510 00029) contains: 45 plugs: FK MCP 1,5/5 ST 3,5 (5 pole) 26 plugs: FK MCP 1,5/8 ST 3,5 (8 pole) 2 plugs: FKC 2,5/5 STF 5 (5 pole, voltage supply) The 1st monitor slot at the system frame offers the possibility to imply a key monitor and to relay its key signals to the other monitors. On the one hand the interface card offers the option of direct connection to a RS485 bus via Dip switch configuration and, in addition, the possibility to connect the monitors to the RS 485 bus by external wiring at the plugs. On the basis of the implemented Dip switches, the RS485 Bus can be configured accordingly. The epro offered screw connection plug set (IMR 6000/10 NC: 9510 00028) contains: 45 plugs: MC 1,5/5 ST 3,5 (5 pole) 26 plugs: MC 1,5/8 ST 3,5 (8 pole) 2 plugs: (5 pole, voltage supply) FRONT MSTB 2,5/5 STF 5 1 bridge: ELB2, (2 pole, ground) mechanical design: dimensions see drawing rear elements: 2 LEDs yellow, voltage supply OK (+24V) net weight: gross weight: approx. 2120 g approx. 2680 g

IMR 6000/20 Slots for adaptation of the signal processing periphery: monitors: 8 x MMS6620 logic cards: 2 x e.g. MMS6740 interface card: 1x e.g. MMS6825 Connection of the external periphery via spring cage and/or screw connection plugs System frame configuration via hardware by bridges or by configuration of the Dip switches Configuration of the RS485 bus lines for integration of all implemented monitors The system frame IMR 6000/20 comprises the following card slots at the front side: 8 slots for monitors of type MMS 6620 4 slots for adaption of two logic cards e.g. MMS 6740 1 slot for connection of an interface Technical Data: voltage supply: two redundant, diode decoupled inputs, nominal +24V with common ground. voltage input: +24V UN+, +24V UB+ common ground: 0V U, GND permissable voltage range: +18V... +31.2V typical power consumption: < 100 W max. permissible fuse of the input current: 4A (per voltage supply) internal generated, galvanically separated voltage: +24V max. power of the internal generated, galvanically separated voltage: 2W The connection of the external frame does take place via 5, 6 and 8 pole spring cage and/or screw connection plugs (Phoenix). The RS485 bus connections as well as the channel clear and the signal outputs of the monitors are fed out via these plugs. voltage supply inputs: KFT according DIN 40 040 accessories: For signal connections and voltage supply, spring cage and/or screw connection plugs are required at the rear of the system frame IMR 6000/20. The spring cage connection plug set offered by epro (IMR6000/20 NC: 9510 00031) contains: 7 plugs: FK MCP 1,5/5 ST 3,5 (5 pole) 36 plugs: FK MCP 1,5/6 ST 3,5 (6 pole) 28 plugs: FK MCP 1,5/8 ST 3,5 (8 pole) 2 plugs: FKC 2,5/5 STF 5 (5 pole, voltage supply) The voltage supply does take place via two 5 pole plugs at the rear of the system frame. On the one hand the interface card offers the option of direct connection to the RS485 bus and in addition the posssibility to connect the monitors to the RS 485 bus by external wiring at the plugs. On basis of the implemented Dip switches the RS485 Bus can be configured accordingly. The screw connection plug set offered by epro (IMR 6000/20 NC: 9510 00030) contains: 7 plugs: MC 1,5/5 ST 3,5 (5 pole) 36 plugs: MC 1,5/6 ST 3,5 (6 pole) 28 plugs: MC 1,5/8 ST 3,5 (8 pole) 2 plugs: (5 pole, voltage supply) FRONT MSTB 2,5/5 STF 5 mechanical design: dimensions see drawing rear elements 2 LEDs yellow, voltage supply OK (+24V) net weight: approx. 2120g/ 74,78oz gross weight: approx. 2680g/ 94,53oz Page 4 of 6

IMR 6000/30 Slots for adaptation of the signal processing periphery: monitors: 8 x MMS6xxx * logic cards: 2 x e.g: MMS6740 interface card: 1 x e.g. MMS6825 Connection of the external periphery via spring cage and/or screw connection plugs System frame configuration via hardware by bridges or by configuration of the Dip switches Configuration of the RS485 bus lines for integration of all implemented monitors Generation of master key signals by a key monitor at the 1st monitor slot * only: MMS 6110, MMS 6120, MMS 6125, MMS 6140, MMS 6210, MMS 6220, MMS 6310, MMS 6312, MMS 6410 The system frame IMR 6000/30 comprises the following card slots at the front side: 8 slots for monitors of the MMS 6000 series * 4 slots for adaptation of two logic cards e.g. MMS 6740 1 slot for connection of an interface The following monitors are supported at the system frame IMR6000/30 in their basic functions: MMS 6110, MMS 6120, MMS 6125 MMS 6140, MMS 6210, MMS 6220 MMS 6310, MMS 6312, MMS 6410 Technical Data: voltage supply: two redundant diode decoupled inputs, nominal +24V with common ground: voltage input: +24V UN+, +24V UB+ common ground: 0V U, GND permissible voltage range: +18V... +31.2V typical power consumption: < 100 W max. permissible fuse for input current: 4A (per supply) internal generated, gavanically separated voltage: +24V max. power of the internal generated, galvanically separated voltage: 2W voltage supply inputs: KFT according to DIN 40 040 Page 5 of 6 The connection to the external frame takes place via 5, 6 or 8 pole spring cage and/or screw connection plugs (Phoenix). The RS485 bus connections, the respective key connection as well as the channel clear, alert and danger alarms of the monitors, are fed out via these plugs at the rear of the system frame. The voltage supply does take place via two 5 pole plugs at the rear of the system frame. accessories: for signal connection and voltage supply, spring cage and/or screw connection plugs are required at the rear of the system frame IMR 6000/30. The spring cage connection plug set, offered by epro (IMR6000/30 NC:9510 00033), contains: 37 plugs: FK MCP 1,5/5 ST 3,5 (5 pole) 5 plugs: FK MCP 1,5/6 ST 3,5 (6 pole) 28 plugs: FK MCP 1,5/8 ST 3,5 (8 pole) 2 plugs: FKC 2,5/5 STF 5 (5 pole,voltage supply) The 1st monitor slot at the system frame offers the possibility to imply a key monitor (MMS6310 or MMS6312) and to relay its key signals to the other monitors. The interface card offers the option of direct connection to the RS485 bus and in addition the possibility to connect the monitors to the RS 485 bus by external wiring with the plugs. The RS485 bus can be configured accordingly by the implemented Dip switches. The screw connection plug set offered by epro (IMR 6000/30 NC: 9510 00032) contains: 37 plugs: C 1,5/5 ST 3,5 (5 pole) 5 plugs: MC 1,5/6 ST 3,5 (6 pole) 28 plugs: MC 1,5/8 ST 3,5 (8 pole) 2 plugs: (5 pole, voltage supply) FRONT MSTB 2,5/5 STF 5 1 bridge: ELB2 5 (2 pole,voltage suppy) mechanical design: dimensions see drawing rear elements: 2 LEDs yellow, voltage supply OK (+24V) net weight: approx. 2120g/ 74,78oz gross weight: approx. 2680g/ 94,53oz

Order numbers: IMR 6000/10 system frame IMR 6000/20 system frame IMR 6000/30 system frame 9100 00095 9100 00096 9100 00097 accessories (not part of the scope of delivery of the system frame) plug set screw connection terminals for IMR 6000/10 9510 00028 plug set spring cage terminals for IMR 6000/10 9510 00029 plug set screw connection terminals for IMR 6000/20 9510 00030 plug set spring cage terminals for IMR 6000/20 9510 00031 plug set screw connection terminals for IMR 6000/30 9510 00032 plug set spring cage terminals for IMR 6000/30 9510 00033 Installation and commissioning of the device may only be made by trained staff. STOP The manufacturer is not liable for damages, caused by improper use or by operation errors of not authorized persons. 1. epro GmbH Jöbkesweg 3 D-48599 Gronau Phone +49 (0) 2562 709-0 Fax +49 (0) 2562 709-255 Page 6 of 6 Further Informations: Internet: www.epro.de E mail: info@epro.de 6010 00104 14/08/2007 V1.00 Printed in Germany. Due to continuous research and product development epro reserves the right to change the specification without notification