Redundancy Module QUINT-DIODE/40



Similar documents
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

PHOENIX CONTACT Features

MINI MCR-SL-R-UI(-SP)

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

PHOENIX CONTACT - 01/2007

RM4TG20 three-phase network control relay RM4-T - range V

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

48 SERIES Relay interface modules 10 A

Power Supplies 3. SDN-P DIN Rail Series

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

38 Series - Relay interface modules A

Operating Manual UWAPS-TINY Series

38 Series - Relay interface modules A

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Electronic overload relay EF19 and EF45

49 Series - Relay interface modules A. Features

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Three-phase monitoring relay CM-PFE

Analog signal converters CC-E I/I Current / current isolators

Telephone- and leased line modem for industrial applications TD-36

CompactLogix Power Supplies Specifications

1788 Linking Device Specifications

Electronic overload relay EF65, EF96 and EF146

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

is then retained absolutely without interruption.

E-STOP relays, safety gate monitors

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Type: DILM32 10(24V50HZ) Article No.:

Contact expander modules

PNOZsigma - Base units

Actuator-Sensor-Interface

PSI-REP-PROFIBUS/12MB

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

TX OPEN RS232/485 module

SYSTEM DESCRIPTION Termination Boards

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

MasterINTERFACE 39 Series - Relay interface modules

Contact expansion modules

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

80 Series - Modular timers 16 A. Features

Type: DILM9 10(24VDC) Article No.:

Cross-beam scanning system to detect slim objects. 100 mm in

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Thermistor motor protection

Foxboro Evo Process Automation System

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

1756 ControlLogix Power Supplies Specifications

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

1756 ControlLogix Chassis Specifications

MasterINTERFACE 39 Series - Relay interface modules

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Safety technique. Emergency stop module BO 5988 safemaster

Spring Cage Feed-Through Terminal Blocks ST

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Digital input modules

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

E-STOP relays, safety gate monitors

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

E-STOP relays, safety gate monitors

1701/22 FieldMonitor Management Interface Module

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

7 - Phaseo power supplies and transformers

Product and functional description

Wind Sensor W-RS485 with RS485 Interface

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

E-STOP relays, safety gate monitors

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

STRATO LED Drivers 70W, Single output

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Transcription:

Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping onto the D rail. Short Description The redundancy module can be used to 00% decouple two power supplies of the same type, which are connected in parallel on the output side to increase power or provide redundancy. The reliability of a power supply determines the availability of individual components in a system and whether complex systems can function safely. Redundant connections are designed for supplying systems, which place particularly high requirements on operational safety. The redundant configuration of the power supply ensures continuous system availability. The power supply of a system can be configured redundantly through the connection of at least two power supply units in parallel. Together they then supply the connected devices. The connected power supplies must be large enough that the total current requirements of all devices can be fully met by one power supply. In the event of an internal fault on one device or a mains voltage supply failure on the primary side, the other device automatically takes over the complete power supply without interruption and vice versa. In this way the operational reliability of the system can be increased effectively. Phoenix Contact GmbH & Co. KG 385 Blomberg, Germany Phone 49-5 35-30 0 Fax 49-5 35-34 00 www.phoenixcontact.com Local Contact: www.phoenixcontact.com/salesnetwork

Redundancy Module. Technical Data 0 mm (4.06 in.) 84 mm (3.307 in.) 6 mm (.44 in.) 0 mm (0.39 in.) solid flexible torque [mm ] AWG [Nm] [Ib in.] 0.5-6 0.5-0 0-6. -.5 0.6-3.3 Redundancy module Description Type Order No. Pcs. Pkt. Redundancy module 9 38 96 3 Technical Data Input Data Input voltage U N /U max Input current I N (Cable cross section 6 mm [0 AWG]) I max (Cable cross section 0 mm [8 AWG]) I max (Cable cross section 6 mm [6 AWG]) I max Transient surge voltage protection using Transil diode Protection against polarity reversal with diode Input/output voltage drop Maximum power dissipation with nominal load 4 V DC/< 30 V DC x 0 A, x 40 A x 9 A, x 39 A (< 40 C [04 F]), x 6 A, x 3 A (< 60 C [40 F]) x 7 A, x 54 A (< 40 C [04 F]), x A, x 43 A (< 60 C [40 F]) x 30 A, x 60 A (< 40 C [04 F]), x 4 A, x 48 A (< 60 C [40 F]) Yes Yes, < 60 V 0.5 V, approximately 0 W, approximately General Data Insulation voltage: Mounting position Can be mounted with spacing Degree of protection Protection class (without PE connection) Efficiency Housing version Dimensions (W x H x D) D rail Weight Input, output/housing - Vertical - Horizontal kv NS 35 D rail according to EN 50 0 5 cm (.969 in.) cm (0.787 in.) IP0 II > 97% AIMg (enclosure), GD-ZnAICu (heatsink) (6 x 84 x 0 mm [.44 x 3.307 x 4.06 in.]) 0.7 kg, approximately Phoenix Contact page of 6

Redundancy Module Climatic Data Ambient temperature - Operation - Storage Humidity Vibration according to IEC 68--6 Shock according to IEC 68--7 Degree of pollution according to EN 50 78 Climatic category Certification/Standards Electrical safety (of IT equipment) Industrial control equipment Conformance mark according to EN 50 0 Electrical equipment for potentially explosive areas Electromagnetic compatibility c Conformance with EMC directive: Noise immunity Noise emission -5 C to 70 C (-3 F to 58 F) -5 C to 60 C (-3 F to 40 F) -40 C to 85 C (-40 F to 85 F) > 95% 3-5 Hz, amplitude ±.5 mm/5 Hz - 50 Hz,.3 g 30 g, 8 ms EN 60 950/VDE 0805, EN 50 78/VDE 060 u UL/C-UL Recognized UL 60 950 U UL/C-UL Listed UL 508 LISTED X II 3G EEx na IIC T4 KEMA 03 ATEX 97X UL/C-UL Recognized UL 604 Class I, Division, Groups A, B, C, D 89/336/EEC EN 6 000-6- EN 55 0/EN 55 0 B ) ) Class B: Industrial and domestic applications EN 55 0 = CISPR ; EN 50 0 = CISPR ; EN 6 000 = IEC 000 3. Device View, Connections, and Control Elements QUT DIODE 3 4 Figure 04 DC input :U N = 4 V, I N = 0 A, I max = 8 A DC input :U N = 4 V, I N = 0 A, I max = 8 A 3 DC output 4 Universal latching foot for NS 35 D rails according to EN 50 0 Phoenix Contact page 3 of 6

Redundancy Module 4. Safety Notes and Warning Instructions To ensure that the device can be operated safely and all functions can be used, please read these instructions carefully. Installation and startup must only be carried out by qualified personnel. The relevant country-specific regulations (e.g., VDE, D) must also be observed. Before startup it is particularly important to ensure that: All supply lines have sufficient fuse protection and are the correct size. All output cables are the correct size for the maximum device output current or have separate fuse protection. Sufficient convection is ensured. To protect the device, the input current of 56 A must not be exceeded. This is ensured if the supply is provided from an automatic current limiting source (e.g., QUT POWER) or if a suitable fuse is connected. To meet directive 94/9/EU (ATEX), the following safety notes must be observed: The redundancy module corresponds to standard EN 50 0. This redundancy module may be installed within a potentially explosive area, in which Category 3 equipment is required. When working on the redundancy module, observe the national safety rules and regulations for the prevention of accidents. The module must only be installed and operated by qualified personnel. Installation should be carried out following the instructions given in this data sheet. The redundancy module should be installed in the control cabinet so that IP54 protection according to EN 60 59 or higher is ensured. If dust is present, the device must be installed in suitable housing. The device must not be subject to mechanical strain or thermal load, which exceed the limits described in this data sheet. To ensure sufficient convection, the following minimum spacing should be provided between other modules: 5 cm (.969 in.) for vertical installation and cm (0.787 in.) for horizontal installation. During operation only devices, which are suitable for operation in potentially explosive areas of zone, can be connected to the redundancy module. The redundancy module does not require maintenance, is closed ex works, and should not be opened. Repairs can only be carried out by the manufacturer. The safety data and features provided according to the valid conformance mark are listed after the technical data. Phoenix Contact page 4 of 6

Redundancy Module 5. Installation 5.. Mounting The redundancy module can be snapped onto all D rails according to EN 50 0-35. The module can be mounted horizontally (input terminal blocks facing upwards or downwards) or vertically on the D rail. Installation Dimensions Mounting Removal To ensure sufficient convection, we recommend the following minimum spacing be used between modules: 5 cm (.969 in.) for vertical installation cm (0.787 in.) for horizontal installation Mounting: Place the module with the D rail guideway on the top edge of the D rail and then snap it downwards. Removal: Release the snap-on catch using a screwdriver and then detach the module from the bottom edge of the D rail. Connection Cable: The following cable cross sections can be connected: QUI Figure 05 Solid Flexible AWG Torque [mm ] [mm ] [Nm] [Ib in.] 3 0. - 6 0.5-0 0-6. -.5 0.6-3.3 For reliable and safe-to-touch connection: Strip 0 mm (0.39 in.) from the connector ends. 0 mm (0.39 in.) mm To maintain UL approvals, use copper cables, which are designed for operating temperatures of at least 75 C (67 F). 3 Figure 06 Phoenix Contact page 5 of 6

Redundancy Module 6. Function 6. Input The maximum permissible current depends on the cross section of the connected cables and the ambient temperature (see Table ). Only one redundancy module is required to decouple two power supplies that are connected in parallel (A and B) with nominal currents up to 0 A. The individual modules are wired together as shown in Figure 7. One redundancy module per power supply is required to decouple power supplies with nominal currents from 0 A to 40 A. Both inputs "" and "" of the redundancy module must be connected to the power supply via two cables as shown in Figure 8. This is required as the maximum current carrying capacity of 30 A per input must not be exceeded. For connecting the redundancy module to the power supply, we recommend using two cables of the same length and with identical cross sections. 6. Output During operation only devices, which are suitable for operation in potentially explosive areas of Zone, can be connected to the output of the redundancy module in Zone. The plus pole of the device is wired to the output of the redundancy module as shown in Figure 7/8. 6.3 Temperature Response In the horizontal mounting position (input terminal blocks facing upwards or downwards), the redundancy x 7 A or x 54 A at ambient temperatures of up to 40 C (04 F). The permissible current carrying capacity reduces according to the ambient temperature as shown in Figure 9, curve a for a cable cross section of 0 mm (8 AWG). At an ambient temperature of 60 C (40 F), the x A or x 43 A. In the vertical mounting position, the redundancy x 7 A or x 54 A at ambient temperatures of up to 30 C (86 F). The permissible current carrying capacity reduces according to the ambient temperature as shown in Figure 9, curve b for a cable cross section of 0 mm (8 AWG). At an ambient temperature of 60 C (40 F), the x 0 A or x 40 A. Table Cable Cross Section 6 mm /0 AWG x 9 A x 39 A 0 mm /8 AWG x 7 A x 54 A 6 mm /6 AWG Ambient Temperature 40 C (04 F) 50 C ( F) 60 C (40 F) x 30 A x 60 A x 8 A x 36 A x 5 A x 50 A x 7 A x 55 A x 6 A x 3 A x A x 43 A x 4 A x 48 A A AB A B I max = 30 A I max = 30 A I max = 60 A I max = 60 A Output current [A] Output current [A] x 7, x 54 x, x 43 x 9, x 38 0 mm /8 AWG 0-5 40 60 70 Ambient temperature [ C] x 7, x 54 x 0, x 40 x 7, x 34 b 0-5 30 40 60 70 Ambient temperature [ C] a GND 4V DC Figure 07 GND 4V DC Figure 08 Figure 09 TNR: 556438-00 04/30/03 Phoenix Contact Phoenix Contact page 6 of 6