MECHANICAL PIPING PAINTING & IDENTIFICATION REQUIREMENTS



Similar documents
Facility Operations Physical Safety Guidance Document

IDENTIFICATION FOR PIPING AND EQUIPMENT

DIN 2403 Identification of pipelines according to the fluid conveyed. Marking of pipes according to fluid transported

PRODUCT IDENTIFICATION SYSTEM FOR TERMINALS / DEPOTS IN SOUTH AFRICA

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

How to Prevent Liquid Damage Property Losses

Water Incursion Standard Operating Procedure

This will also provide you with the knowledge to insure long life for your Investment

Asbestos Management Program

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Glossary of Heating, Ventilation and Air Conditioning Terms

Automobile Air Conditioning Primer

Dry Ice Color Show Dry Ice Demonstrations

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

Fire Alarm System Plans Review Checklist Property location Date of Review

A. Shop Drawing submittals shall include, but not be limited to, the following:

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

Important Notes Color

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Housing Services Guidance for tackling condensation, damp and mould in your home

During Various Aluminum Fabricating Operations

CATHODIC PROTECTION SYSTEM DESIGN

Tubing and Accessories

Compliant Healthcare Technologies, LLC. NFPA 99, 2012 Changes" November 13, 2013!

Electronics and Soldering Notes

VERIFY HARD COPY AGAINST WEB SITE IMMEDIATELY PRIOR TO USE

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

Refrigeration Installation 101

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

A/C refrigerant system, overview

COATINGS MANUAL HRSD 6.0 EQUIPMENT AND PIPING COLOR IDENTIFICATION CODE

The Anatomy of a Label

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Safeguard Storm Doors Beauty, the security of advanced design, and the guarantee of a lifetime.*

FLOOR TREATMENT 09610

Munsell Soil Color. Munsell Gradient No. Code

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

FIRE EXTINGUISHER TRAINING

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

Quantifying the energy and carbon effects of water saving summary report

Element D Services Plumbing

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Roller bearing life. The Reaction of AISI Bearing Steel to Heat

DC Circuits (Combination of resistances)

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

PMS Reflex Blue C Mining PMS 8401C

Chapter 3.4: HVAC & Refrigeration System

Photo 1: This photograph shows drywall, joint compound, cove base mastic, carpet adhesive, and ceiling tile in store front No. 1.

THE HUMIDITY/MOISTURE HANDBOOK

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

3 Scotch-Seal TM. Tamper Proof Sealant Technical Data Issue No. 5

Energy Efficiency HOSPITALITY.

Simplify your palette

Asbestos WHAT TO DO? Studies of people who were exposed to high levels of asbestos in factories and shipyards, are at increased risk of:

Steam Generation Efficiency Module Blowdown Losses Section

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

Aluminium as Construction Material in Ammonia Refrigeration Cycles

The Peak of Protection

PLUMBING, HEATING & AIR CONDITIONING, REFRIGERATION & BOILER INSTALLATION CONTRACTORS QUESTIONNAIRE

RHOPLEX AC-264 Emulsion Polymer 100% Acrylic Binder for Exterior Flat, Satin and Semigloss Architectural Coatings

Lindab Colour Chart. For every colour under the rainbow

TABLE OF CONTENT

presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Monday, 17 June, 13

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

saving energy in comfort Factsheet Recair Enthalpy

Gas Marketplace Work? July 9-13, 2007

3 Single-Coated Foam Tapes

When Should Examination Preparation Begin?

Chapter 16: Tests for ions and gases

Regulatory Services. Asbestos in the Home. What is asbestos?

Monitoring Air Emissions on Ships. Restricted Siemens AG 2014 All rights reserved.

INDEPENDENTS AIL RET 2012

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

EACH CLASS of fire A, B, C, or D has a different source. Some

Builder Specifications for Solar Ready Homes

08.08 Vic-Check Valves

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 34 C IED (2010/75/EU) (calculated)

REQUEST FOR QUOTE. Material $ Labor/Installation $ tax $ Total $ Material $ Labor/Installation $ tax $ Total $

SPREFIX SPRAY INSULATION _ in the marine market.

Wiring Diagram. Diplomat 400V 3N.

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Module 2.2. Heat transfer mechanisms

Lindab Coverline TM. Lindab Tile Effect Roofing. Make a lasting impression

Horizontal Jet Pumps 1/3-1-1/2 HP

PRODUCT DATA SHEET DESCRIPTION:

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

User's Instructions. Alpha HE CB25/33 and HE SY25

Transcription:

MECHANICAL PIPING PAINTING & IDENTIFICATION REQUIREMENTS This document shall supersede all other published data concerning mechanical piping painting and identification as described below until such time that any conflicting published data is changed to match. The following is a summary of instructions which should be communicated to contractors to simplify the mechanical piping painting and identification requirements. This section is divided into five (5) areas for general clarification. 1. MECHANICAL ROOMS: Insulated Piping shall conform to the following: o Band plastic coverings with appropriate color on 20 ft (6 m) intervals or less; o Alpha-numeric system identification (e.g. CHW1S, CHW1R) on 20 ft (6 m) intervals or less; o Flow arrows on 20 ft (6 m) intervals or less; o Banding, system identification, and flow arrows shall be placed on shorter intervals where piping visibility is affected by congestion of piping, ductwork, electrical conduit and the like; o Stencils may be accepted if paint does not run on the plastic pipe covering. Manufactured pipe labelling systems may be accepted. Un-insulated piping (black steel or otherwise) shall conform to the following: [EXCEPT Natural Gas] o Mould resistant paint light reflective color (can be same color as walls) o Band piping with appropriate color on 20 ft (6 m) intervals or less; o Alpha-numeric system identification (e.g. CNDW1S, CNDW1R) on 20 ft (6 m) intervals or less; o Flow arrows on 20 ft (6 m) intervals or less; o Banding, system identification, and flow arrows shall be placed on shorter intervals where piping visibility is affected by congestion of piping, ductwork, electrical conduit and the like; o Stencils are acceptable; o Manufactured adhesive labels are acceptable if the adhesive is durable. Natural gas piping shall conform to the following: o Entire piping system painted throughout the building; o Mould resistant paint (see color chart below); o Alpha-numeric system identification on 20 ft (6 m) intervals or less (e.g. Natural Gas LP, Natural Gas HP); o System identification shall be placed on shorter intervals where piping visibility is affected by congestion of piping, ductwork, electrical conduit and the like; o Stencils are acceptable; o Manufactured adhesive labels are acceptable if the adhesive is durable. 2. EXPOSED AREAS: [other than Mechanical Rooms] Same conformance criteria as Mechanical Rooms except that the paint need not be mould resistant. 3. CONCEALED AREAS: [EXCEPT within walls] Same conformance criteria as Mechanical Rooms. REV 0 Page 1 of 2

4. HIDDEN PIPING WITHIN WALLS: No system identification except where the mechanical piping enters or leaves the wall. 5. HIGH HUMIDITY AREAS: [Concealed or otherwise] Same conformance criteria as Mechanical Rooms. Notes: 1. Piping system identification, banding, and flow arrows must be provided on both sides of a pipe passing through a wall, at all sides of tees, and behind access doors. 2. Considerations shall be given to the size and scope of the project (e.g. asbestos abatement, small piping alteration, overhaul to a portion of the mechanical systems). In projects where the entire piping system within a room is not being replaced, piping identification may be done to match the existing undisturbed piping. For example, if the existing piping is completely painted canvas wrap, then the newly modified piping system may be completely painted to match the existing. Discuss with the Project Manager and/or the Design Consultant. Provide system identification labels, flow arrows, and stripes as described in this document. 3. Refer to accompanying Pipe Identification Color Code Standard chart. 4. Apply color bands at both sides of the piping system identification stencil. 5. Banding shall consist of a 12 wide colored band, or wider to accommodate system identification labels, with a 3 wide colored stripe overtop of the band on either side of the system identification label. 6. The band shall match the color in the chart for the appropriate pipe service. 7. The stripe shall match the color in the chart for the appropriate pipe service. 8. It is the Contractor s responsibility to devise their method of banding given the following guidelines: a. Banding must be permanently fastened. b. Banding must not be affected by heat, moisture, etc to the extent where it becomes unrecognizable, changed in appearance over time, or no longer adheres to the pipe. c. The Contractor shall submit a sample of the proposed banding method to the University for review and approval. The University reserves the right to refuse the proposed system at no expense to themselves if in their judgment the proposed banding method does not meet the acceptance criteria. In this situation, the Contractor must submit alternative methods until a method satisfactory to the University has been approved. Any comments can be directed to the undersigned. Regards, Darren St.Hilaire, P.Eng Manager, Mechanical Engineering Design and Technical Services, Planning and Project Delivery, Facilities and Operations Phone (780) 492-6126 darren.sthilaire@ualberta.ca REV 0 Page 2 of 2

Pipe Identification Color Code Standard Pipe Service Band/Stripe (Low VOC / CP4 Fandeck) Chilled Water (Supply) Band: - 17BG 36/333 [ Taking the Plunge ] Card 181 & Number A1266 Chilled Water (Return) Band: - 17BG 36/333 [ Taking the Plunge ] Card 181 & Number A1266 Stripe: - 4216.9000 [Title - Safety Red *] or 31YR 10/591 [ Crimson Red ] Card Condensed Water (Supply) Band: - 17BG 36/333 [ Taking the Plunge ] Card 181 & Number A1266 Stripe: - 4216.9990 [Title - Black *] Condensed Water (Return) Band: - 17BG 36/333 [ Taking the Plunge ] Card 181 & Number A1266 Stripe: - 4216.DC2000 [Title- Aluminum Gray *] or 30BB 53/012 [ Silver Trophy ] Card Low Pressure Steam Stripe: - 4216.DC2000 [Title- Aluminum Gray *] or 30BB 53/012 [ Silver Trophy ] Card Low Pressure Condensate Stripe: - 4216.DC2000 [Title- Aluminum Gray *] or 30BB 53/012 [ Silver Trophy ] Card High Pressure Steam Stripe: - 4216.9000 [Title - Safety Red *] or 31YR 10/591 [ Crimson Red ] Card High Pressure Condensate Stripe: - 4216.9990 [Title - Black *] or 30YY 05/044 Title - The Dark Side ] Card 262 / Number A1834 Pumped Condensate Stripe: - Custom color 4216 [Title- Tudor Brown ] or 80TR 17/129 [ Turret Brown ] Card 246 / Number A1721 Dust Mop Band: - 00NN 31/000 [Title- Icon Grey ] Card 288 & Number A2012 Fuel Oil Stripe: - 4216.9000 [Title - Safety Red *] or 31YR 10/591 [ Crimson Red ] Card Lubricating Oil Valve (Low VOC / CP4 Fandeck or Alt * ) or Valve Color: - 30YY 05/044 Title - The Dark Side ] Card 262 / Number A1834 Valve Color: - 4216.9000 [Title - Safety Red *] or 31YR 10/591 [ Crimson Red ] Card 42/Number A0291 Valve Color: - 4216.9000 [Title - Safety Red *] or 31YR 10/591 [ Crimson Red ] Card 42/Number A0291 REV 0 Page 1 of 4

University of Alberta Pipe Identification Color Code Standard Pipe Service Band/Stripe (Low VOC / CP4 Fandeck) Engine Exhaust Glycol (Supply) Stripe: - 50BB 08/257 [Title- Subzero Blue] (doesn t match exactly) Card 199 & Number A1393 Glycol (Return) Stripe: - 4216.9000 [Title - Safety Red *] or 31YR 10/591 [ Crimson Red ] Card Nitrogen Band: - 67GY 40/437 [Title- Garden Party ] Card 145 / Number 1011 Demineralized Water Band: - 90GY 08/187 [Title- Southern Pine ] Card 146 & Number A1022 - Very Dark Green Stripe: - 4216.9000 [Title - Safety Red *] or 31YR 10/591 [ Crimson Red ] Card Constant Head Band: - 70GY 74/149 [ Marine Glow ] Card 157 Number A1094 Freon (liquid) Band: - 90BB 67/069 [Title- Lavender White ] Card 218 / Number A1520 Sprinkler Wet Stand Pipe Dry Stand Pipe Stripe: - 4216.0100 [Title- White *] Carbon Dioxide Stripe: - Pipe: - 17BG 36/333 [ Taking the Plunge ] Card 181 & Number A1266 Valve (Low VOC / CP4 Fandeck or Alt * ) Valve Color: - 67GY 40/437 [Title- Garden Party ] Card 145 / No. 1011 Valve Color: - 90GY 08/187 [Title- Southern Pine ] Card 146 & Number A1022 - Very Dark Green Valve Color: - 90GY 08/187 [Title- Southern Pine ] Card 146 & Number A1022 - Very Dark Green Valve Color: - 90GY 08/187 [Title- Southern Pine ] Card 146 & Number A1022 - Very Dark Green] Oxygen Band: - 95GY 24/449 [Title- Green Street ] Card 160 / Number A1120 Nitrous Oxide Band: - 90BG 50/157 [Title- Jordan ] Card 196 Number A1368 Natural Gas Valve Color: - 4216.9000 [Title - Safety Red *] or 31YR 10/591 [ Crimson Red ] Card 42/Number A0291 Vacuum Band: - 4216.DC2000 [Title- Aluminum Gray *] or 30BB 53/012 [ Silver Trophy ] Card REV 0 Page 2 of 4

University of Alberta Pipe Identification Color Code Standard Pipe Service Band/Stripe (Low VOC / CP4 Fandeck) Compressed Air (7 PSI) Band: - 4216.DC2000 [Title- Aluminum Gray *] or 30BB 53/012 [ Silver Trophy ] Card Compressed Air (HP) Band: - 4216.DC2000 [Title- Aluminum Gray *] or 30BB 53/012 [ Silver Trophy ] Card Compressed Air Controls Band: - 4216.0100 [Title- White *] or 10BB 83/006 [ Atmosphere ] Card 23 / Distilled Water Band: - 90GY 08/187 [Title- Southern Pine ] Card 146 & Number A1022 - Very Dark Green Drinking Water Chilled (Supply) Band: - 50BB 08/257 [Title- Subzero Blue] (doesn t match exactly) Card 199 & Number A1393 Stripe: - 29YR 19/621 [Title- Shanghai ] Card 59 & Number A0410 Drinking Water Chilled (Return) Band: - 50BB 08/257 [Title- Subzero Blue] (doesn t match exactly) Card 199 & Number A1393 Domestic Cold Water Band: - 95GY 24/449 [Title- Green Street ] Card 160 / Number A1120 Domestic Hot Water Stripe: - 95GY 24/449 [Title- Green Street ] Card 160 / Number A1120 Domestic Hot Water Band: - 95GY 24/449 [Title- Green Street ] Card 160 / Number A1120 (Return or Recirculation) Heating Hot Water (Supply) Stripe: - 00NN 31/000 [Title- Icon Grey ] Card 288 & Number A2012 Heating Hot Water (Return) Band: - 00NN 31/000 [Title- Icon Grey ] Card 288 & Number A2012 Sump Pump Discharge Lines Band: - Custom Color 4216 [Title- Tudor Brown ] or 80TR 17/129 [ Turret Brown ] Card 246 / Number A1721 Valve (Low VOC / CP4 Fandeck or Alt * ) Valve Color: - 29YR 19/621 [Title- Shanghai ] Card 59 & Number A0410 REV 0 Page 3 of 4

University of Alberta Pipe Identification Color Code Standard Notes: 1. Colors listed with the following Coding/Naming System (ie: 95GY 24/449 [Title- Green Street ] Card 160 / Number A1120) are selected from the ICI Glidden Paints CP4 Fan Deck Master Colour Palette. 2. *Alternate Paints (Particularly solid colors and safety colors) often feature two (2) paint options the 1 st taken from the #68100E Devoe, High Performance Coatings Brochure Titled, Colors for Industry typically contain the Coding/Naming System (ie: 4216.9400 [Title- Safety Yellow *] and the 2nd from the ICI CP4 Fan Deck Master equivalent (ie: 45YY 51/758 [ Golden Green ] ). 3. Only Low VOC Paints should be used in U of A Projects. 4. The Prefix 4216 usually indicates a Devflex HP system in a Standard Color or a Custom Paint Mixture using low VOC tinting. REV 0 Page 4 of 4