LEOY-SOME ISTALLATIO POULIBLOC 000-000 097 en - 0.06 / e This document complements the general instructions ref. 557 (recommendations), ref. 7 (ATEX specific recommendations) and the maintenance instructions Poulibloc 000-000 ref. 5069. OTE LEOY-SOME reserves the right to modify the characteristics of its products at any time in order to incorporate the lastest technological developments. The information contained in this document may therefore be changed without notice. LEOY-SOME gives no contractual guarantee whatsoever concerning the information published in this document and cannot be held responsible for any errors it may contain, nor for any damage resulting from ist use. CAUTIO The specifications, instructions and descriptions are for standard operation. They do not take account of structural variants or special adaptations. Failure to comply with these recommendations may lead to premature deterioration of the gearbox and voiding of the manufacturer s guarantee. Throughout the manual, this symbol warns of consequences which may arise from inappropriate use of the Poulibloc 000-000 since risks may lead to material or physical damage. Despite all the care taken in the manufacture and checking of this equipment, LEOY-SOME cannot guarantee that lubricant will not escape during the product s lifetime. If slight leaks could have serious consequences for the safety of people and property, the installer and user should take all necessary precautions to avoid such consequences. COTETS - POULIBLOC 000.... - Installation recommendations..... - Identification..... - Tapered bushing mounting..... - educer mounting..... - Input shaft sheave mounting.....5 - Torque arm mounting.....6 - Motor location.....7 - Mounting a cylindrical hollow shaft into the driving machine shaft.....8 - Backstop installation.... - Lubrication..... - Plugs position..... - Oil quantity... 5. - Maintenance... 5 - POULIBLOC 000...6. - Installation recommendations... 6.. - Identification... 6.. - Mounting... 6. - Lubrication... 6.. - Plugs position... 6.. - Oil quantity... 6. - Maintenance... 6 Copyright 0 : MOTEUS LEOY-SOME. This document is the property of MOTEUS LEOY-SOME. It cannot be reproduced in any form without prior authorisation. All brand names are registered trademarks. 0
LEOY-SOME ISTALLATIO POULIBLOC 000 097 en - 0.06 / e - POULIBLOC 000. - Installation recommendations Installation must be performed by qualified personnel. Allow sufficient room around the gearbox for plugs accessibility. Gearbox: For the installation of Poulibloc 000 gearbox, follow the ecommendations chapter in the general manual... - Identification Gearbox nameplate: - gearbox type ; - operating position ; - K fixing type : torque arm ; - possible options (AD) ; - reduction ; 5- serial number ; 6- lubricant : delivered without oil... - Tapered bushing mounting For small bore bushings (fig. ) - Fit the bushing key () into the keyway on the tapered bushing (). - Insert the tapered bushing () into the locking ring () and driving hollow hub, taking care that bushing key fits into hollow hub keyway. - Turn locking ring counter clockwise two turns. For large bore bushings (fig. ) - Fit single special key () into driven shaft keyway. - Insert the tapered bushing () into the locking ring () and driving hollow hub. - Turn locking ring counter clockwise two turns. F GA en 5 H7 i min - MOTEUS LEOY-SOME Pb B K 89 7 90 / 00 50088 GB fig. fig. 6 Standard bore sizes (fig. ) Taper bushes depending on size D H7 F GB GA 0 5 6 7 0 6 6.5.5 l 5 8 8 l l 0 8 6 l l l 5 0 0 8 ll l l l 0 5 ll l l l 5 9.5 8.5 ll l l l 50.5 5.5 ll ll l l 55 6 9 59 ll ll l 60 8 5 6 ll l l 65 8 58 69 l l 70 0 6.5 7.5 ll l l 75 0 67.5 79.5 ll l l 80 7 85 ll l 85 76 90 ll l 90 5 8 95 l l 95 5 86 00 ll 00 8 90 06 ll l 0 8 00 6 l 0 09 7 l Minimum length of customer shaft 80 8 05 6 5 9 60 l Key to be supplied by customer with small bore, GA dimensions indicated. ll Key supplied, GA dimensions non-indicated.
LEOY-SOME ISTALLATIO POULIBLOC 000 097 en - 0.06 / e.. - educer mounting (fig. ) - Fit bushing reducer assembly onto driven machine shaft (5). ote: on large bore bushing, take care special key fits into hollow hub keyway. - Slide unit to desired position. It should not be mounted such that dimension A is less than 6 mm and greater than one shaft diameter. - Tighten locking ring () with special wrench (supplied) allowing the reducer to draw up the bushing (). Do not exceed 70.m of torque on the locking ring. - Insert and tighten set screw (6). ote: inspect and tighten tapered bushing after 8 hours of use. To remove bushing or reducer, reverse above procedures. Do not remove screw ref. 99 of part list. ote: protective output shaft cap can be removed in applications where driven shaft is mounted through hollow shaft. In other applications, keep in place for protection against dirt and water. fig... - Input shaft sheave mounting emove protective material from input shaft and clean it with cleaning solvent, if necessary, to remove any residue remaining on shaft. Mount sheave on input shaft as near as possible to shaft shoulder because excessive overhung loads could occur and greatly reduce the life of the bearings (fig. ). In particular do not hammer on reducer or sheave in mounting it. If difficulties occur in the mounting of the sheave, it is advised to use a soft mallet (neoprene type) or heat the sheave for easy installation. Warning: excessive belt tension can greatly reduce -belt life and damage bearings (motor, reducer). Follow -belt manufacturers instructions and recommendations. Once sheaves and -belts have been installed, check for proper alignment. Caution: for safety, user must provide a protective guard mounted around the -belt and sheave...5 - Torque arm mounting Attach the torque arm housing bracket to the reducer housing. Three positions are recommended, although eight positions are possible (fig. 6). Assemble the torque arm and attach the torque arm floor support to a rigid base. Since all the reactive forces go through the torque arm, it is most adventageous to mount the torque arm at 90 to a line between the hollow shaft and the torque arm holding bolt (fig. 7, 8 & 9). The torque arm must allways be mounted so the reactive forces are in tension with the reducer. This is dependent upon the rotation of the output shaft; mount torque arm in: - section A for clockwise rotation (fig. 5a); - section B for counter-clockwise rotation (fig. 5b)...6 - Motor location Tension of -belt is adjusted by the torque arm. Install the motor such that the belt be at 90 from the center line between driven and input shaft. Do not restrain the housing of Poulibloc on the built of the machine; use the torque arm bracket. Section A : clockwise rotation Section B : counter-clockwise rotation Poulibloc seen from output shaft end side fig. fig. 5a fig. 5b fig. 6 fig. 7 fig. 8 fig. 9
C LEOY-SOME ISTALLATIO POULIBLOC 000 097 en - 0.06 / e..7 - Mounting a cylindrical hollow shaft into the driving machine shaft MOUTIG Pb 0-- to Pb 6-- Size ØA B C Hub C Shaft Mini lenght Client shaft Maxi lenght Pb 0 8 0. 75 90 Pb Pb Pb Pb Pb 5 Pb 6 Pb 7 5. 5 75 00 5 8.8 8.5 75 00 8 5.8 5.5 95 0 50 5.8 5.5 95 0 55 6 59. 59 95 0 60 8 6. 6 95 0 55 6 59. 59 05 0 60 8 6. 6 05 0 65 8 69. 69 5 5 70 0 7.9 7.5 5 5 75 0 79.9 79.5 5 5 75 0 79.9 79.5 50 85 80 85. 85 50 85 85 90. 90 50 85 80 85. 85 90 0 00 8 06. 06 90 0 90 5 95. 95 60 0 00 8 06. 06 60 0 05 8. 60 0 0 8 6. 6 60 0 0 7. 7 60 0 O ring seal Pb 7-- Fixing on shouldered shaft O ring seal en B Fixing on shaft without shoulder O ring seal A DISMOUTIG Pb 0-- to Pb 6-- - Ensure that the cylindrical shaft has been machined according to standard F - E - 75, with a sliding fit: g6 (the hub is: H7). - Ensure that the keyway is standard and the shaft has a minimum length : see chart... - Before mounting, clean grease off all parts, taking care not to get solvent on the seals. Cover all parts which come into contact with a light coating of oil, so as to prevent corrosion. Take care not to knock the shaft when mounting as shown below. The Pb 7 gearbox is mounted on the machine shaft with a threaded tierod, screwed to the shaft. By tightening the nut which presses on the washer, the shaft is gently inserted in the cylindrical hub of the Poulibloc. Pb 7-- O ring seal A hydraulic hub-remover is used for dismantling the shaft, by pressing on the outer groove of the hub.
LEOY-SOME ISTALLATIO POULIBLOC 000 097 en - 0.06 / e..8 - Backstop installation The backstop used to prevent the reverse rotation of the gearbox, is mounted on the input shaft (manual ref. ) for Pb 0 to. For Pb 05, 5, 6 and 7 sizes, it is fitted with rotation as specified on the order. Backstop kit ef. Description Qty 09 backstop cap 0 free wheel flange 0 inner race external retaining ring 7 internal retaining ring 8 shims (Pb 05, 5, 6 and 7) to 6 O ring seal 70 O ring seal 9 cover cap 09 inner race key 68 fixing screws, washers 0 free wheel. - Lubrication Gearbox Poulibloc is supplied without oil. Before running it is necessary to: - determine mounting position (see table..) ; - install drain plug (magnetic) to lowest gearbox point ; - fill gearbox up to level plug ; - place the breather plug to highest gearbox point. ecommended oil Gearbox with or without backstop, for operation: - between -0 and +50 C: mineral oil extreme pressure ISO G 0 (Mobilgear 600 XP 0, Shell Omala S G 0) ; - between -0 and +50 C: synthetic oil PAO ISO G 50 (Mobil SHC SIBUS 50)... - Plugs position (,, ) 5 5 5 5 A = 5 B = 0 60 95 5 5 fig. 0 Tapered bushing Input shaft. Plugs: fig. 0 Pb 0 to : G / ; Pb 5 to 7 : G / ; (before 0/06 -> Pb 0 to 7 : M6x50) : Filling - : Level - : Draining Areas to be used for satisfactory operation and perfect lubrication
LEOY-SOME ISTALLATIO POULIBLOC 000 097 en - 0.06 / e Oil capacities The oil capacities shown in table are approximative values and should be used only as reference in determining how much oil to provide. The proper oil levels can only be determined by filling the reducer to the level of the plug (fig. 0). ote: For proper oil level other than horizontal position, maximum inclination allowed is A=5 and B=0 (fig. ). For special mounting position not shown, please consult LEOY-SOME... - Oil quantity (considering operating position) Place the breather plug at the top of the gearbox B Operating position Pb 0 Pb Pb Pb Pb Pb 5 Pb 6 Pb 7 G / G / G / G / G / G / G / G / litre litre litre litre litre litre litre litre en 0.75.75.5 5 8.5 B6 0.75 0.9.75..55 5. 8. B7 0.75 0.9.75..55 5. 8. B8 0.7 0.75...9 7.6 5.5.5.5.5.5 6.5 9.5 7. Tolerance: ± 0.05 litre for oil quantity < 5 litre ± % for oil quantity 5 litre. - Maintenance - Mineral oil: drain every 5000 hours of operation (or every 6 months). - Synthetic oil: for T 70 C, drain every 5000 hours of operation. It is nevertheless recommended to check proper oil level periodically (every 5000 hours) and oil should be added if the level is low. 5
LEOY-SOME ISTALLATIO 097 en - 0.06 / e POULIBLOC 000 - POULIBLOC 000. - Installation recommendations Installation must be performed by qualified personnel. Allow sufficient room around the gearbox for plugs accessibility. Gearbox: For the installation of Poulibloc 000, follow the ecommendations chapter in the general manual. For very low speed applications the gearbox must be completely filled since ther is no splash lubrication. unning in: change oil after approximately 00 hours. ever use additive or doping when a backstop is fitted... - Plugs position.. - Identification Gearbox nameplate: - gearbox type ; - operating position ; - fixing type (U) ; - reduction ; 5- serial number ; 6 - lubricant : Pb is lubricated with grease for 0 000 hours running. 5 Place the breather plug at the top of the gearbox 5 Operating position 50088 Pb 05 B U 89 7 900 / 00 5,08 min- EP 0 Plugs type B6 MOTEUS LEOY-SOME Pbh 08 B U 89 7 90 / 00 7,85 min- B7 50088 i 6 B8.. - Mounting Mount the unit directly on the driven shaft of the machine, then secure it axially by tightening two pointed grub screws provided, (Pbh series) or by one screw and washer at the end of the shaft. In order to make easier the mounting and later a possible removal, it is strongly recommended to coat the driven shaft and the hollow shaft with molybdenum disulfur grease. Only parallel keys.. - Lubrication Pb 000 : For operation between -0 C and + 0 C, the gearbox Pb 000 is normally supplied lubricated for 0 000 hours running with grease (Mobil, MOBILUX EP 0). Pbh 000 : Gearbox Pbh 000 is supplied without oil. Before running it is necessary to: - install drain plug (magnetic) to lowest gearbox point ; - fill up approximatly to one third of the height (considering B position) ; - place the breather plug to the highest gearbox point. ecommended oil: for operation between -0 and +50 C, mineral oil extreme pressure EP ISO G 0 ; between -0 and +50 C: synthetic oil PAO ISO G 50 (Mobil SHC SIBUS 50). 6 n Pbh G / litre Pbh G / litre Pbh G / litre.7.75.7.75.7.75.7.75.7.75 B 6 Pbh delivered without oil... - Oil quantity MOTEUS LEOY-SOME i 5. Tolerance: ± 0.05 litre for oil quantity < 5 litre Level - Draining - Breather - Filling. - Maintenance The gearboxes do require a minimum of care, and, when dismantled following instructions: - mineral oil: drain every 5 000 hours. - synthetic oil: for operating temperature < or = 70 C, drain every 5 000 hours. It is nevertheless recommended to check proper oil level periodically. It is important to check periodically that the belt tensions are not excessive and that the alignement of the drive is correct. Observe the lubricant instruction. Consult us for details regarding abnormal temperature conditions and suitable oils. An excess of oil may cause overheating and leakage.