Presentation. Lightning Protection practices in Bangladesh :An overview



Similar documents
Transient and Lightning Protection for the Water Industries

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

Between sky and earth

THE LIGHTNING PROTECTION INTERNATIONAL STANDARD

Power Quality for Information Technology System

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

Class I surge protection with sparkover gaps

Lightning Protection Introduction

Minor maintenance issues proving difficult to detect for many solar PV system owners

SURGE PROTECTIVE DEVICES

CHAPTER 6 INSTRUMENTATION AND MEASUREMENTS 6.1 MEASUREMENTS

How can a charging station for electric vehicles be set up simply and safely?

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

1. Franklin Rod Performance 2. LEC/DAS Performance

TABLE OF CONTENT

How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse

The complete range of consumer switchboards and switchgear

Video Camera Installation Guide

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

Lightning strikes onboard

City Of Ottawa High Voltage Substation Inspection, Maintenance Rev July 17 and Testing, ROPEC Page 1

Lightning Arresters P KVA P KVA. Description & Installation

RVH/BCH Data Centres Proposals for Surge Protection and Ventilation

Electric Vehicle Charging Solutions

Canopy Surge. User Manual

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

DOES A STROKE BETWEEN CLOUD AND GROUND TRAVEL UPWARDS OR DOWNWARDS?

Fuses. Introduction. Measuring is knowing. Who chooses?

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note

Coexistence of Automatic Weather Station (AWS) System in harsh environmental conditions at National Meteorological Centre (NMC) Colombo, Sri Lanka.

Data Assessment for Electrical Surge Protection Devices

Electrical Grounding. Appendix C

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. Secondary Transient Protection for T1/E1 Line Cards

Safe Work Procedure. Purpose To ensure all employees are educated and prepared in the event of a lightning storm.

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

FaultAnalysisandElectricalProtectionofDistributionTransformers

HOW DOES A LIGHTNING ROD WORK? by MARTIN A. UMAN ORIGINALLY PUBLISHED IN

THE MINARET INCIDENTS AT PUTRAJAYA

Power surges can also be generated by equipment in your facility such as:

Surge Protection s Essential Role in the Cable Telecommunications Triple Play

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

PowerWorld Transmission Line Parameter Calculator

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Estimation of electrical losses in Network Rail Electrification Systems

EARTHING SYSTEM CALCULATION

Security Cameras, CATV, GPS & Satellite Protection. White Paper

Konti Skan Replacement of Cable 1

This is a preview - click here to buy the full publication TECHNICAL REPORT

Assessment of Soil Resistivity on Grounding of Electrical Systems: A Case Study of North-East Zone, Nigeria

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

RULES FOR INSTALLATION OF COMMUNICATION TOWERS.

Use the following information to deduce that the gravitational field strength at the surface of the Earth is approximately 10 N kg 1.

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Experiment NO.3 Series and parallel connection

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

GroundRod AC Substation Earthing Tutorial

6 Buck Boost Transformers

CHAPTER 4 THE THUNDERCLOUD 4.1 THERMAL DYNAMICS

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

PG&E Transmission Interconnection Handbook. Section L3: SUBSTATION DESIGN FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

7. What is the current in a circuit if 15 coulombs of electric charge move past a given point in 3 seconds? (1) 5 A (3) 18 A (2) 12 A (4) 45 A

Forms of Energy. Freshman Seminar

3 Radio Waves and Human Body 8 Specific Absorption Rate (SAR)... 8 SAR value of a mobile handset... 8 Radiation level by a mobile tower...

3. Cooling System Closed-loop Pure Water-cooling. Rated Voltage: 6 ~ 66kV. Rated Current: 4000A (phase current).

Lightning Protection in India

Voltage, Current, and Resistance

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

Electrical Power System Fundamentals for Non-Electrical Engineers

POWER AND VOLTAGE RATING

Energy efficiency and fuel consumption of fuel cells powered test railway vehicle

HIGH VOLTAGE CALCULATIONS / EVALUATIONS. West Virginia Office of Miners Health, Safety & Training

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

SOLAR PV SYSTEM MAINTENANCE GUIDE

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Chapter 9. Bonding and Grounding

How to Prevent Power Surges: The Leading Cause of Serial Device Server Failures

ELECTRICAL SAFETY RISK ASSESSMENT

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants

Future grid infrastructure Field tests of LVDC distribution

Bourns Resistive Products

Consultants Handbook

Temporal variation in snow cover over sea ice in Antarctica using AMSR-E data product

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space.

How much more electricity do we use in a heatwave?

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Current Measurement of Resistance Spot Welding Using DSP

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Inside atoms + + Democritus

Gas Discharge Tubes GTCX36-XXXM-R05 Series

Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.

Isolated Lightning Protection Systems & HVI Conductor

Transcription:

Presentation on Lightning Protection practices in Bangladesh :An overview Abidur Rahaman Dept. of Applied Physics and Electronics University of Dhaka, Bangladesh

Outline Lightning and lightning protection systems Current practices and measures in Bangladesh

Haunting Memoirs in Bangladesh

Haunting Memoirs in Bangladesh Lightning strikes kill 9 in Bangladesh (21 Mar 2008, Asia World News) Five killed by lightning (28 May 2007, DPA) 6 killed in lightning in Bangladesh's southern districts (08 August 2006, UNI) Lightning Kills 5 in Bangladesh (12 September 2006, The Indian Express) Lightning bolt killed nine and injured 23 in northeastern Bangladesh, 16 February 2006. 8 people were killed and 40 people were injured at Chapainawabgonj, on the 12th July 2005.

LIGHTNING FACTS Globally 44,000 thunderstorms/day and 100 lightning strokes /sec Duration of one stroke of lightning, 1/5 th of second. Voltages 1,00,000 kv and peak current 30 ka. Total energy released 40 GJ. Temperatures rises 50,000 degrees Celsius Lightning strokes ranges from 100 m 8 km length. Lightning can travel at speeds of 60,000 m/sec Lightning heats nearby air to about 10,000 C.

Real captured image of lightning strike

Some examples of damage by Lightning and surge current The microscopic runs on a processor chip are extremely susceptible to surge related heat stress. The surges meets resistance, converts to heat and causes a blister on the run. Cumulative Catastrophic Installation in Bangladesh Surge Protective Device (SPD) As the repetitive surges continue to hit the spot over time, the blister grows until it effectively blocks the power or data flow on that circuit.

World s Thunderstorm days per year Bangladesh has 80 to 120 days/year

Annual flash rate: NASA satellite report, Bangladesh has 40-50 flash per square kilometer

WHAT IS LIGHTNING LIGHTNING is a SPARK Lightning a Gigantic Electrical Spark Traveling between Cloud to Cloud or Cloud to Earth Containing an average charge of 30 to 50 lakhs Volts and a current of 30 Kilo amperes with a speed of 220 km per hour.

A Complete LIGHTNING PROTECTION system Air Terminals Down Conductors Ground Terminals Interconnecting Conductors Surge Protective Devices, and Other Connectors or fittings required to complete the system.

Lightning Protection System Capturing system: Franklin rod system Meshed Conductor by Faraday cage Early Streamer Emission

FRANKLIN RODS Based on the Benjamin Franklin s (1752) original design which uses points effects. Charges around a conductor accumulate on the sharpest ends and easily overcome air resistance. Rp H The protected area is limited and depends directly on the height at which the point is placed and on the required protection level.

MESHED CONDUCTORS Commonly known as Faraday Cages In use since 1884 when Melsens proposed this practice for buildings protection. Fundamentals: inside a perfect continuous conductive cage there is no risk and no electrical field variation appears when an electrical current is flowing over its surface. In practice, this is possible with costly and most of the times unaesthetic arrangements.

EARLY STREAMER EMISSION AIR TERMINAL : ESE Bigger protection area (min 32 meter radius) Right moment trigerring (15-45 micro second) Easy installation Air terminal with a triggering device which ionizes the end point of the rod, controlling the generation. This control leads an early streamer emission before any Franklin rod does ( t) and in the right moment, achieving a bigger protection area. Rp 2 H Rp 1

LIGHTNING PROTECTION SYSTEM (LPS) ESE METHOD WITH SIMPLE AND COST EFFECTIVE INSTALLATION WORKS Installation in Bangladesh DAT CONTROLER PLUS ❶ Protecting very costly And sensitive equipment At the tower and beneath its control room from direct Lightning strike ❹ ❷ ❸

Lightning Protection: Implementation Franklin method Radius of influence : 3m Height of lightning rod: 1m Cost per 32 meter radius protected area: 3Million BDT Faraday case method Cost per 32 metre radius protected area: 5 million BDT ESE method Cost per 32 meter radius protected area: 0.3 Million BDT With imported ESE lightning rod

Continuous Effort in Bangladesh Bangladesh National Building Code (BNBC) first proposed in 1993 and legally binding in 2006 gives clear regulations for setting up Lightning Arrestor in buildings more than 33m high. Fire Service and Civil Defense department and Public Works Dept. (PWD) of Bangladesh government are working relentlessly in lightning awareness and protection in common people. It is obligatory to take the NOC (No Objection Certificate) for all realtors which comply with BNBC code. Border Guards Bangladesh (BGB) completed a survey on lightning and surge protection in September 2008 in the country s hilly southeast portion signaling sites and camps. Barapukuria coal mining company started for setting up modernized lightning protection device from 29 th September 2008

Continuous Effort in Bangladesh More than 35000 Base Station Subsystem (BSS) sites by six cellular operators all over the country. Two WiMAX operators & Radio-TV broadcast stations tower only increases this number. These are all structures built on plain fields or rooftops. The average height ranging of these tower are 15-50 meters. All of these tower and high rise structures are more prone to get a lightning strike. As these sites are backed up by Batteries, IPS and auto start diesel driven generator, the probable occurrence of lightning and subsequent firing damage is a looming threat. In 2006, mobile operator Teletalk Bangladesh Ltd. completed setting up modern lightning protector to their 150 BTS. Their estimated budget for lightning protection is 110 million BDT. A Dhaka based organisation named TARA(Technological Assistance for Rural Advancement) working on lightning awareness program to mass people that achieved notable attention.

Preventive Measures For safety and protection the following measures are essential: Proper installation of ESE Type Lightning Protection System (LPS) Proper installation of Surge Protective Devices (SPD) Installation of Residual Current Circuit Breaker (RCCB) or Residual Current Device Installation of Miniature Circuit Breaker (MCB or MCCB) Very low resistance Grounding / Earthing as per international standard.

Thank You