Kiosk Design Specifications Manual



Similar documents
A Complete Solution CREATING WALLS THAT DEFINE SPACE

PUBLIC RESTROOMS, DESIGN INTENT

glass & Glazing Products

TENANT ARCHITECTURAL DESIGN CRITERIA HANDBOOK #1

DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS

signsvisual i n d u s t r i e s servicing New York City since 1991.

take off FREESTANDING

Walmart 4th Wall. Advertising and Lease Line Guidelines. June Customerexperience

Standard Design TKLP Cab

Hybrid Display System

HOW TO MAKE CUSTOM-SIZED IKEA KITCHEN CABINETS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

DIY CABINET REFACING INSTALLATION GUIDE

Portable Displays & Accessories

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Architectural Casework Description of Work

screens U N D E R S TA N D I N G S C R E E N S PA N E L WA L L A D D - O N S C R E E N B A S I C S...9 3

KITCHENS REMODELED Before and After

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

Base Cabinet with Self-storing Folding Doors and Floor

Beautiful kitchens and bathrooms to meet your budget! KITCHEN REMODELING BATHROOM REMODELING COUNTERTOPS AND MORE!

Contents. Fulcrum CE Executive Workstation Light Oak and gloss white lacquer workstation and storage

Combination & Screen Doors

SECTION MediaStation Model 125 Electric Lateral Files (ELF)

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

Kitchen and Bath Design Tutorial

GENERAL WIRING RULES FOR HOUSES

Automatic Door Selection Guide

Integral Kit Instructions

Retail Reception kiosk

2D & 3D TelePresence

Kitchen planning guide.

Santa Barbara Lounge 24W x 31H x 24D AH22

ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS

Consoles Product Guide. Great American Desk Company Great American Desk Company

Sliding and Folding Door Fittings Sliding Door Accessories

PORTABLE MODULAR DISPLAY DESCRIPTION KIT 115, 129, & 135

Park View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.

REFRIGERATION. Standard Features & Accessories. Model Options. Built-In 30 W. Full-Height Wine Cellar. All models include. VCWB300 Professional

Irvinton Village Apartments 2901 Fulton Houston, Texas Houston Housing Authority J. Allen Management Managing Agent

LIGHTING FOR KITCHENS / UTILITY ROOMS / WORKSHOPS / KITCHEN CABINETS / GLASS CABINETS / FURNITURE

How you select and where to install me! Kitchen BE CAREFUL OF FOLLOWING PARAMETERS : A- Plumbing space needed (specifically the height).

Company Name Contact: Address City. State Zip Code Phone # Exhibit Selection: Please reserve the following unit # Color

THE IDEAL SOLUTION SHELVING. Sales Telephone: Sales Fax:

Installation Instructions and Ordering Information

CLEAR-DIVISIONS CENTERFOLD

REQUEST FOR QUOTE. Material $ Labor/Installation $ tax $ Total $ Material $ Labor/Installation $ tax $ Total $

POPUP DISPLAY SYSTEMS

DIGITUS Network & Server Cabinets. UNIQUE Series

Domain. US Price List

TOTAL SHOWROOM SOLUTIONS 2014 CATALOG. Palmer Promotional Products. dish.palmerdist.com/catalog

Legacy Cabinet Catalog

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

19 DYNAmax Free Standing Server C A B I N E T s

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

LABORATORY CASEWORK. Table of Contents. Laboratory Cabinetry and Specialties. ADVANTAGE laboratory. Series/Model Number Specification...

Fiera di Vicenza S.p.A. offers fitted booth areas in compliance with fire Safety measures. (Features and dimensions are purely indicative) 70 /sqm

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

MIDMARK DENTAL CABINETRY vs LOCAL CABINET MAKERS

DESK CABINETS & BOOKSHELVES

19 DYNAmax Free Standing Server C A B I N E T s

2015 Building Products Catalog. Design Centers Door, Window & Siding Displays. Columns & Pedestals Demonstration Tools

ARTS AND CRAFTS (open) 5412 (doors) H : 84" Tote Tray Storage. Damp Storage. Tote Tray Storage. Notebook Board Storage, Doors

SECTION REFERENCE. Tilt-Wash Double-Hung. Insert Windows. 400 Series

Latigos Trail 911 Latigos Trail ~ Des Peres, Missouri $428,500

Corporate Design Manual Design Guidelines for Trade Shows and Events

Profiles. Exclusively Manufactured By

HOW AND WHERE DO I USE IKEA

Cascade Remodeling Inc. PO Box Portland, OR Catalyzing Euphoria Phone (503) , FAX (503) CCB # 67007

CLEAR-DIVISIONS VARIOFOLD

MILLENNIUM HIGHEST STANDARD OF QUALITY Millennium features the finest materials available, including the highest grade Cherry, Maple, Oak and Walnut


Holz Choices & Specifications

Kitchen and Bath Design Tutorial

BAR - the build guide. best practice for bar construction

Why buy Nimbus? Nimbus Why Buy?

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...

Concepts. Products. Service. Lindner Plus Organisation

Andersen Clad Inswing Entry Doors (2001 to Present)

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Coat Racks Floor Racks Hooks Hangers Hook Panels Wardrobes

FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1

Video Conferencing Solutions

AMERICAN GOTHIC PLAYHOUSE

contents classic 3 switch 4 mini swing 5 sign wedge 6 chalkboards 7 all purpose A frames 8 H2O swingmaster 9 café banner 10 vision 11

Tel: Sales: STORAGE CABINETS. PREMIERSHIELD anti-bacterial powder coating system. quality products made in the UK

Residential Window Replacement Design Guidelines

CONTAIN Credenzas ORGANIZATION FROM THE INSIDE OUT

NEW. Teramo See Page 136

Wren Kitchens Installation Tips Carefully check your kitchen delivery Measuring out and marking up Fitting the base cabinets...

Coyote popup features

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

6 Signage & Displays External Office Signage Internal Office Signage 6.2 Exhibition Displays 6.3 Slide Presentations

Ceramic Glass Electric Galley Ranges

Master. Pieces. Customization Options from the AMG Performance Studio. Valid from 1 February 2013

MORE THAN A LINEAR DRAIN. THE SOLUTION FOR SHOWERS & WET AREAS.

Transcription:

Kiosk Design Specifications Manual

Kiosk Program I. General Requirements II. Materials Palette III. Design Rules for All Kiosk Components IV. Graphic Design Requirements V. Core Element (Canopy and Spine) VI. Types Design Intent Size Lighting Requirements A. 360 Kiosk Design Intent Size Lighting Requirements Configurations B. Retail Kiosk Design Intent Size Lighting Requirements Configuration Examples C. Food & Beverage Kiosk Design Intent Size Lighting Requirements Configuration Examples D. Wall Hugger Kiosk Design Intent Size Lighting Requirements VII. Special Conditions Attachment: Supplemental Design Intent Documents 2

Kiosk Program Summary Kiosk Program The Kiosk program has been developed to enhance the opportunities to provide quick food and retail offerings to patrons with limited time during transit. The kiosk is a self-contained unit, therefore must be designed for maximum efficiency and flexibility. The following manual will describe the four (4) Kiosk Types developed for DFW Airport. Kiosk Types 1. 360 Kiosk 2. Retail Kiosk 3. Food & Beverage Kiosk 4. Wall Hugger Kiosk General Requirements Kiosks are freestanding units located throughout the Terminals where ceilings and floors are in place, and as temporary in-line tenants along the concourse. Creativity, uniqueness and high quality are characteristics of the overall identity of DFW International Airport. In order to ensure consistency and continuity among the Kiosks, a common design appearance and design standards have been developed. The core of the Kiosk design is a Canopy & Spine Element that is the backbone of the various options of kiosks available for tenant use. Each tenant s kiosk solution must incorporate this Core Element (fig. 1) as shown in provided drawings in this manual. There is a standard core and a shortened core for use in the smaller layouts. In order to meet the tenants various retail needs, flexibility in design will occur in areas other than the core element. The tenant s design solution must be submitted for Airport approval and the Airport reserves final judgment as to the acceptability of proposed solutions. Standard Core Element, Figure 1 Note: The shortened core eliminates the center cabinet and acrylic panel. Please see page 11 of this document for drawings or slide 3 in the Attachment A: Supplemental Information. 3

Materials The approved finishes for the kiosks are shown below. Reference images for each particular type of material and the location to be used on the kiosk is shown below. Any finish substitutions must closely match the finishes provided below and must be submitted for review and approval by DFW. All materials used in the kiosk fabrication must be durable and non-corrosive. A carefully defined edge must be established between different materials and surfaces on the kiosk. Approved Kiosk Finishes Bamboo Accent Panels Used in Core Element & Base cabinets. Acceptable Manufacturers: PlybooPure Veneer Amber Prefinished Edge Grain Teragren Vertical Grain Carmelized panels 3/4 (Prefinished). Fabrication Standards: 1. Panels to be installed so that grain is horizontal. 2. Bamboo Panels must be trimmed in Stainless Steel at all edges, ¼ wide. Laminate Used in base cabinets (not in Core Element). Acceptable Manufacturers: Pionite Laminate #SG254 Ash Gray Nevamar #S7027T Smoky White No Substitutions. Manufactured Granite Used as countertops in Core Element and base cabinets in SLAB form. Acceptable Manufacturer: Silestone Rosa Grey Fabrication Standards: 1. Fabricator to provide an Eased Edge. No Substitution. Bronze Metallic Paint Used in Core Element top spine signage field. Acceptable Finish: Forms +Surfaces Fused Bronze Metal Finish: Sandstone Scuffmaster Paint Solid Metal SM8106 Finish description: Baked enamel metallic bronze paint on metal. 4

Approved Kiosk Finishes, cont d. Frosted Acrylic Panels Used in Core Element and Wallhugger signage panel. Acceptable Manufacturer: 3Form 1. Varia panel with Vapor Layer (to be used at top beam element where panels are to be lit from within) 2. Chroma Reflect with Vapor Layer (for use in panels with no backlighting) No Substitutions. Brushed Stainless Steel Used in Core Element Base cabinets (metal or laminate clad). Acceptable Manufacturers: Forms +Surfaces Stainless Steel Finish: Sandstone Generic finish designation #4 Brushed Finish Stainless Steel Fabrication Standards: 1. Brushed Stainless Steel panels to be installed so that brushed pattern is installed vertically. Polished Stainless Steel Used to frame the mesh panels in the canopy, the transitional trim between materials and all light fixtures. Generic finish designation #8 Mirror Finish Champagne Metallic Paint Used as an accent infill panel in base cabinets and Wall-hugger unit. Acceptable Manufacturers: Scuffmaster Paint #EM8369B Finish description: Baked enamel metallic champagne paint on metal No image provided Silver Metallic Paint Used in Core Element Canopy (painted, brushed finish). Acceptable Manufacturers: Scuffmaster Paint EM808B Finish description: Baked enamel metallic silver paint on metal White Matte (Flat) Paint Used in reveals at the acrylic panels. Description: White matte paint, color to match 3Form Acrylic Panels. Ref. Elevations for locations. Acceptable Manufacturers: Benjamin Moore Sherwin Williams 5

Approved Kiosk Finishes, cont d. Stainless Steel Mesh Used in Core Element and Wallhugger Canopy. Description: 3/16 Round on 7/32 Staggered Perforated Metal. Satin Finish Acceptable Manufacturers: McNichols Marco Specialty Steel, Inc. Direct Metals Gordon Fabrication Standards: 1. Perforated Stainless Steel panels to be inset into Polished Stainless Steel frames. Toe Kick Base (straight) Used in all Base cabinets. Acceptable Manufacturers: Johnsonite #63 Burnt Umber Roppe #193 Black Brown Burke Flooring #523 Black Brown Fabrication Standards: Base of cabinets to be 4 high x 3 deep. Finish material to be of a rubber or vinyl material, straight (un-coved) profile Canopy Light Fixtures Used as light source in canopy. Description: 1-Light Linear Double Gimbal fixture with built-in Electronic Transformer. Input voltage: 120V Output voltage: 12V Lamp: MR16 Trim Finish: Silver/Polished Acceptable Manufacturers: Jesco Lighting Group MG1560-1E Cooper Lighting Combolight C1037M16E1TGSS (lamp wattage may vary) Nora Lighting NL-463 6

Design Rules for All Kiosk Components All fabricator drawings and samples must be submitted for review and approved by DFW prior to actual fabrication to concur that the design intent has been satisfied. 1. Coordinating Trim Stainless Steel (#8 finish) to be used at all outside corners and as a transition between changes in materials. Stainless steel corner guards to be ¼ in width. Transition strips shall be ½ wide at changes in material other than where manufactured granite is used on counters. The transition detail at counters should be 1 wide. Detail at outside corner Transitions between material changes Examples shown by Haogin and Schulter. 2. Where standards and brackets are used for shelving supports, the standard must be installed so that it sits behind the face of the panel and be low profile Front view of low profile standard behind wood panel, with bracket attached. Rockler Low Profile Standard 7

3. All cabinet hinges must be concealed (Soss, European type, or similar) or semiconcealed (piano type). Where piano hinges are used, they should run continuous the full length of the cabinet door. Examples of manufacturers include Rockler, Blum, Soss, Grass, Sugatsune. Figure 2. Hinge Types, Figure 2 4. The design solution must provide an integrated security grill mechanism or blocking mechanism to inhibit encroachment or access into the kiosk after hours. The use of fabric shrouds or tents will not be permitted. The materials used for security should remain consistent with those of the kiosk itself, (metal, mesh, glass, etc). When not in use the security mechanisms must be concealed. The kiosk fabricator will have the ability to tailor the security requirement to the actual kiosk use. Refer to the figures on this page for conceptual ideas. Figure 3. Close up of conceptual security component Figure 3 8

Graphic Design Requirements Below are the guidelines for Tenants to use for signage, kiosk are to be fabricated to accommodate the following guidelines. Signage is an important finishing touch for kiosks and must receive the same attention to quality and detail as the rest of the kiosks. Figure 4 1. On all kiosks, excluding the Wall-hugger type, the core Canopy and Spine Element is where tenant signage will be located. Figure 4. 2. The Tenant s name or logo must be located at both ends of the top beam. An area in the bamboo spine has designated to accept an internally illuminated sign box, supplied by the manufacturer. The outside edges of the sign box are to be trimmed stainless steel. Figures 4 & 5. The following construction methods and materials are permitted for signage, supplied by the Tenant. Other conditions are subject to approval: Figures 5 Dimensional (3D) graphics with pinned letterforms or logo constructed of an acrylic face panel, lit from behind. All exposed edges to be clad in brushed stainless steel or aluminum. The area for letters must not exceed 1 6 w x 11 h, see graphic to the left. 3. Signage is required on the front of the kiosk within the niche of the bamboo spine. Options for signage are a light box, supplied by manufacturer. Light box will need to be able to accept a duratran inserts. Graphics will supplied by the Tenant. Figure 6 4. The designated area for Graphics in the Wall-hugger unit is located in the illuminated frosted acrylic area beneath the canopy. Tenants shall display their name or logo with applied vinyl copy to the illuminated acrylic panels. Figure 7. Figure 6 Figure 7 9

Kiosk Core (Spine) Element 1. 2. Figure 8 1. The Canopy is comprised of a painted metal frame, with a secondary frame (polished or chromed stainless steel) to house a metal mesh (satin finish). The mesh panels (see 1.3.7) will provide the location for the light fixtures (see 1.3.8). The canopy terminates into the Spine Element. Ref. Figure 8, Pages 11 & 12. 2. The Spine element consists of a base cabinet clad in brushed stainless steel, topped with a white frosted acrylic display element and a bamboo wood box with framed niche for a light box. The display element has the option for both open and closed shelving at the end. Ref. Figure 8, Pages 11 & 12 3. The top element has areas on each end, and both sides, for tenant signage. The middle portion consists of white frosted acrylic panels and linear lighting. The linear lighting must be installed so it will provide an evenly dispersed up-lighting affect. This can be achieved with the use of linear LED or Cold Cathode lamps. Ref. Figure 8, Pages 11 & 12 4. DFW design requirements for electrical service to tenant spaces do not allow for individual circuits to originate from board panels. The intent is for the tenant to install a feeder to the built-in subpanel with main circuit breaker located within the kiosk space. This allow for the capability to disconnect power within the space and not having to find where circuits are being fed from. The kiosk electrical panel must be located in the bottom cabinet on the far right side of the kiosk. The food and beverage kiosk requires four (4) 20 amp circuits, two (2) 20 amp circuit for the 360 kiosk, wall-hugger, and retail. All circuits to be connected to the kiosk panel with a disconnect switch. 10

11

12

13

360 Shop Around Kiosk Figure 8 Figure 9 1. Design Intent Figure 10 Figure 11 The 360 Shop Around is designed for the tenant requiring the smallest footprint and provides a complete walk around shopping experience. Figures 8, 9, 10 & 11. 2. Size The footprint of the 360 Shop Around base unit must be 4 x 8, drawing below. The configuration of each 360 Shop Around can vary to fit each tenants needs as long as the core Canopy and Spine Element and all finishes match those provided in this Design Manual. The footprint must not exceed the limits provided by DFW Concessions Airport. Figure 12. Figure 12 14

3. This kiosk utilizes the shortened Core Element as indicated on previous page, see # 2. 4. Lighting Requirements Direct lighting will come from the light fixtures located in the canopy. There will be 2 directional fixtures in each end panel and one fixture in the center panels. (Reference section on materials for light fixture standards. ) Figure 13 Canopy Plan with Light Fixtures Figure 13 5. Configuration Examples The layouts shown below are examples of the 360 Shop Around unit. This is not a comprehensive list or limited to what is shown. Each tenant will be able to submit a proposed layout that addresses their needs. Figure 14. Figure 14 15

Retail Kiosk Figures 15 Figures 16 Figure 17 Figure 18 1. Design Intent 2. Size The retail RMU kiosk is for a tenant who is seeking a larger footprint and more flexibility in display configurations. Figures 15, 16, 17 and 18. The Retail Kiosk size will vary based on configurations and lease agreement. The standard module will start from a 10 x 10 footprint, and expand to 10 x 15, 10 x 20, etc. The standard Core Element is required. Configurations of cabinets and display cases are to be designed utilizing the aforementioned rules and must be submitted for review by DFW Concessions Department. Figure 19. 16 Figure 19

3. Lighting Requirements Direct lighting will come from the light fixtures located in the canopy. There are to be 2 directional fixtures in each panel. (Reference section on materials for light fixture standards.) Figure 20. Canopy Plan with Light Fixtures Figure 20 4. Configuration Examples Layouts shown are examples of approved layouts and material usage of the Retail Kiosk. Each tenant must submit proposed layout to DFW Concessions Department for review and approval. 17

Food & Beverage Kiosk 1. Design Intent The Food & Beverage kiosks are designed for those tenants selling food and beverage items. 2. Size The Food and Beverage kiosk size will vary based on configurations and lease agreement. The standard module will start from a 10 x 10 footprint, and expand to 10 x 15, 10 x 20, etc. The standard Core Element is required. Configurations of cabinets and display cases are to be designed utilizing the aforementioned rules and must be submitted for review by DFW. Layouts shown are examples of approved layouts and material usage. Figure 21. Figure 21 3. Lighting Requirements Direct lighting will come from the light fixtures located in the canopy. There are to be 2 directional fixtures in each panel. (Reference section on materials for light fixture standards.) Figure 22. Figure 22 18

4. Configuration Examples The layouts shown below provide an example Food & Beverage Kiosks. Each tenant must submit a proposed layout for DFW Concessions Department for review and approval. Figures 23 and 24 Figure 23 Figure 24 19

Wall-hugger Figure 25 Figure 26 Figure 27 1. Design Intent 2. Size The Wall-huggers were developed to be used against walls and do not require the standard core element but a back wall element. Unit must incorporate a way to secure the merchandise afterhours. All designs must be submitted to DFW Concessions Department. The footprint of the Wall-hugger unit is 5 w x 2 d x 9 h. The configuration of each Wall-hugger can vary to fit each tenants needs as long as the core back wall Element and all finishes match those provided in this Design Manual. These units must be stand-alone to form a continuous line and/or fill a niche space. The footprint must not exceed the limits provided by DFW Concessions Department. Figures 25, 26, 27 and Pages 20,21 and 22. 3. Lighting Requirements Direct lighting will come from the light fixtures located in the top of the wall-hugger and the back-lit acrylic panels. There are (two) 2 directional fixtures in each mesh panel. (Reference section materials for light fixture standards.) Figure 25, Page 21 4. For dimensions and details refer to following pages 20, 21 and 22. 20

21

22

23

VII. Special Conditions General Information o Power must be provided for lighting and signage light box. o All cabinets must be lockable. o All glass enclosed cabinets must be lockable. o All drawers must be lockable. o Wall-hugger must have four (4) adjustable shelves with low profile brackets. o All units must have a hidden latch system which prevents units from moving while in place. o Food and Beverage Kiosk must allow space for refrigerator, ice machines and soda fountains. Equipment to be provided by operator. o Wall-hugger units must be interlocking. o DFW design requirements for electrical service to tenant spaces do not allow for individual circuits to originate from board panels. The intent is for the tenant to install a feeder to the built-in sub-panel with main circuit breaker located within the kiosk space. This allow for the capability to disconnect power within the space and not having to find where circuits are being fed from. The kiosk electrical panel must be located in the bottom cabinet on the far right side of the kiosk. The food and beverage kiosk requires four (4) 20 amp circuits, two (2) 20 amp circuit for the 360 kiosk, wall-hugger, and retail. All circuits to be connected to the kiosk panel with a disconnect switch. o All units must be constructed to meet the DFW Airports current adopted codes. o Food and Beverage kiosks must be constructed to include all requirements of the Tarrant Co. Health Department. Specific Information-Refer to Supplemental Information o Base Unit C- Must include two (2) adjustable shelves with low-profile brackets. o Base Unit H-This unit is only to be used on the sides of the F&B Kiosk. Upper storage cabinets are an option only for this unit. o Base Unit I Must include three (3) adjustable shelves with low-profile brackets. o Base Unit J Must include three (3) compartment sink per Tarrant Co. Health department. o Base Unit F- Drawers are in a cabinet inserted underneath a parsons table. Category Configurations, each category consists of the following combinations: o 360 Kiosk Spine (Core)-Shortened version. Base Unit D Base Unit E o Retail Kiosk Spine (Core) Base Unit A Base Unit B Base Unit C o Food and Beverage Kiosk Spine (Core) Base Unit A Base Unit C Base Unit G 24

o Wall-hugger Wall-hugger Unit 25