V-TEK IVP System 2.7 System 4.0

Similar documents
Zimmer Small Fragment Universal Locking System. Surgical Technique

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

NCB Distal Femur System. Surgical Technique

Zimmer Periarticular Proximal Tibial Locking Plate

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)

Posterior Referencing. Surgical Technique

Zimmer Periarticular Elbow Locking Plate System

Expert HAN. Expert Hindfoot Arthrodesis Nail.

TransFx External Fixation System Large and Intermediate Surgical Technique

Malleolar fractures Anna Ekman, Lena Brauer

Achilles Tendon Repair, Operative Technique

How To Fix A Radial Head Plate

DARCO MRS. Locked Plating System for Reconstructive Rearfoot Surgery

Technique Guide. Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system.

VariAx Distal Radius Locking Plate System. Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates

ACTIV ANKLE DISTAL AND DIAPHYSEAL FIBULA INNOVATION MEANS MOTION

Technique Guide. 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis.

TwinFix Cannulated Compression Screw

CLAW II. Polyaxial Compression Plating System SURGIC A L T ECHNIQUE

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Technique Guide. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System. Part of the Synthes variable angle locking compression plate (VA-LCP) system.

OptiLock Periarticular Plating System For Proximal Tibial Fractures. Pre-Launch Surgical Technique

Versa-Fx II Femoral Fixation System Surgical Techniques

Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail

Integra. Subtalar MBA and bioblock Implant SURGICAL TECHNIQUE

How To Use A Phoenix Retrograde Femoral Nail

NCB Proximal Humerus System. Surgical Technique

Zimmer Natural Nail System. Cephalomedullary Nail Surgical Technique STANDARD

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation.

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

MatrixNEURO CMF Matrix

DRAFT. Triathlon TS Knee System. Surgical Protocol. Version 1

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

LCP Compact Foot/Compact Hand.

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

PERIPROSTHETIC IMPLANTS

Titanium Wire with Barb and Needle. For canthal tendon procedures.

Expert LFN. Lateral Femoral Nail.

Calcaneus (Heel Bone) Fractures

Knotilus TM. Anchor Instability Repair. Technique Guide

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

TriLock 1.5 Implants for the Phalanges

TABLE OF CONTENTS. Indications and Contraindications 3. Features and Benefits 4. Ease of connection 4 Stable fixation concept 5

NCB Periprosthetic Femur Plate System. Surgical Technique

Technique Guide. 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System.

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

METAL HEMI. Great Toe Implant SURGICAL TECHNIQUE

Technique Guide. Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

Technique Guide. 2.4 mm LCP Distal Radius System. A comprehensive plating system to address a variety of fracture patterns.

Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction

M/DN Femoral Interlocking & Recon Nail Intramedullary Fixation Surgical Technique

Zimmer PSI Knee System For Use with Persona The Personalized Knee System Surgical Technique

The information contained in this document is intended for healthcare professionals only.

Lateral Ankle Instability Repair using TWINFIX Ti 3.5 mm Suture Anchors

ACL Reconstruction with Bone-Tendon-Bone Transplants Using the ENDOBUTTON CL BTB Fixation System

Surgical technique. End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue.

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

ANTERIOR CERVICAL DISCECTOMY AND FUSION. Basic Anatomical Landmarks: Anterior Cervical Spine

Wrist and Hand. Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Fractures of the Wrist and Hand: Carpal bones

Elbow System 2.0, 2.8

Technique Guide. Norian SRS Fast Set Putty. Calcium phosphate bone void filler.

VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty

TRIGEN TAN and FAN Intramedullary Nails

Implant Extraction Guide Module One & Two

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

Zimmer MOST Options System

Original Assembly Guide

Surgical Technique. coflex Surgical Technique

Expert TN. Tibial Nail.

the revo / mini-revo shoulder fixation system s u r g i c a l t e c h n i q u e

TRIGEN INTERTAN Intertrochanteric Antegrade Nail Surgical Technique. Table of Contents

The information contained in this document is intended for healthcare professionals only.

MatrixNEURO. The next generation cranial plating system.

TFN Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

Spinal Arthrodesis Group Exercises

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

Foot Surgery Innovation in Forefoot Reconstruction BAROUK SCREW FRS SCREW TWISTOFF SCREW MEMORY STAPLE VARISATION STAPLE

ZERO-P VA. Variable angle zero-profile anterior cervical interbody fusion (ACIF) device SURGICAL TECHNIQUE

MEDACTA UNCONSTRAINED SCREW TECHNOLOGY. Surgical Technique. Hip Knee Spine Navigation

GENEL KATALOG GENERAL CATALOGUE KİLİTSİZ PLAKLAR NON LOCKING PLATES

KnifeLight. Carpal Tunnel Ligament Release. Operative Technique

LISS PLT. The less invasive stabilization system for proximal tibia fractures.

Osteoarthritis progresses slowly and the pain and stiffness it causes worsens over time.

Sports Injuries of the Foot and Ankle. Dr. Travis Kieckbusch August 7, 2014

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

LCP Olecranon Plate. The anatomical fixation system with angular stability for olecranon and proximal ulnar fractures.

Cable System. For Orthopaedic Trauma Surgery.

NARROW DIAMETER implant

Assembly and Usage Instructions

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

Lentur Cable System. Surgical Technique

Zimmer PSI Knee System For Use with the NexGen Complete Knee System Surgical Technique

Fracture Fixation Devices Compression Hip Screws Cannulated/Bone Screws Bone Plates, Pins, Wires

INTRODUCTION INTERLOCK KIT K-8110

Double Bone Plug Meniscus Reconstruction Surgical Technique

Transcription:

V-TEK IVP System Ankle 2.7 Fix System 4.0 Surgical Technique Surgical Technique Titanium osteosynthesis system for tibio-talar and tibio-talo-calcaneal fusion

SECTION 1 Ankle Fix System 4.0 Titanium osteosynthesis system for tibio-talar and tibio-talo-calcaneal fusion Patient Positioning Place the patient in the supine position with an ipsilateral pelvic sand bag or midlateral position. Surgical Technique Step 1 Incision for Ankle Fix Plates (TT Fusion) Using a lateral approach, make a straight incision to enable the best view of the lateral talar and calcaneal walls. Mobilize the peroneal tendons. Incision for Ankle Fix Plus Plates (TTC Fusion) Using a lateral approach, make a straight incision longer than the TT fusion incision to allow access to the subtalar joint. Mobilize the peroneal tendons and retract them posteriorly. Step 2 Fibular Resection Resect approximately 8 cm-10 cm of the distal fibula, depending on the patient s anatomy and according to the plate dimension. The fibula may be morselized for additional bone graft after removing the periosteum and all soft tissue. Step 3 Bone Preparation Prepare the joint in the usual manner. Use burrs, curettes, and osteotomes (such as a Charcot chisel or special osteotomes for joint surface preparation) to decorticate the involved joint surfaces until subchondral bone is fully exposed on each side. Ensure that the joint surfaces are prepared congruently. Note: Care should be taken to maintain the desired position of the arthrodesis throughout the procedure. In particular, when the compression is applied to the arthrodesis, the surgeon should prevent the hindfoot drifting into excessive valgus alignment. Decortication of joint surfaces Decortication of joint surfaces 2

Step 4 Temporary Positioning of the Arthrodesis Temporarily position and fix the ankle alignment with 2 mm K-wires. Optional: With the fibula removed, there is easy access to the posterolateral aspect of the tibial metaphysis. A K-wire can be placed from the postero-lateral tibia into the neck of the talus over which a cannulated single- and partial threaded screw (with or without a washer) can be applied to provide compression across the arthrodesis. Ensure the screw is of sufficient strength and does not lock the arthrodesis in the direction in which compression will be applied by the Compression/Distraction Device later on in Step 12. The Ankle Fix plate is then used to neutralize the fixation. Optional Step 5 Temporary Fixation of the Plate Select the appropriate anatomical plate side and size (see page 6), according to the patient s bony anatomy and chosen procedure (TT or TTC fusion). Apply the plate to the bone surface and temporarily hold it with 2 mm K-wires while using image intensification to ensure that it is correctly positioned. Some contouring of the tibial incisura may be required to seat the plate flush with the bone. Step 6 Drilling the Distal Screw Holes Drill distal screw holes accordingly to each specific plate: Ankle Fix drill only the talus screw holes Ankle Fix Plus drill only the calcaneus screw holes Bicortically drill the distal screw holes (calcaneus/talus) through the holes in the plate, using the 2.7 mm Twist Drill (black mark). Use as many screw holes as possible to ensure stable fixation. For locking screws, the corresponding 2.7 mm threaded-tip Drill Guide (black mark) must be used to avoid damaging the threads and to ensure correct drill direction. While not required, the Drill Guide is also recommended for standard screws to help minimize wear on the drill bit and damage to the threads on the plate. Note: Because of the plate contours, a threaded screw will not always engage the screw hole at a 90 angle to that portion of the plate s surface that surrounds the hole. For proper threading of the Drill Guide into the hole, ensure that the Drill Guide is aligned with the direction of the threads in the hole (see illustration). Then tighten it gently. Step 7 Depth Measurement for Distal Screws Position the Depth Gauge on the plate hole and advance the probe into the predrilled hole until it penetrates the opposite cortex. Read the length directly from the Depth Gauge. Note: If the drill hole does not penetrate the opposite cortex, measure where the probe bottoms out. Read the length directly from the gauge and subtract 1 mm to determine the appropriate screw length. (The screw length includes the length of the head.) 3

Ankle Fix System 4.0 Step 8 Distal Screw Insertion Use as many screws as possible to ensure stable fixation. Attach the screwdriver blade to the handle by pulling back on the coupling, inserting the blade into the shaft, and releasing the coupling. Pull on the blade to ensure that it is locked into the handle. The screwdriver has a ratchet function to simplify screw insertion. Insert the screws bicortically, if possible. The screwdriver can be used to facilitate removal of the screws from the tray by pushing the tip of the blade firmly into the screw head in a vertical direction to achieve a secure grip. Note: Use only the screwdrivers available with the Ankle Fix System. Inserting the screws with inappropriate instruments may damage the screw threads. Do not use damaged screws. Step 9 Adjustment of Compression/Distraction Device Attach the Hinge Blade to the screwdriver handle and use it to move the fixation pin sleeve into the middle of the Compression/Distraction Device (see illustration 1). 1 proximal middle distal Step 10 Application of Compression/Distraction Device Remove any K-wires that were used for temporary plate or bone positioning. While holding the device in a proximal/distal direction as marked on the device (see illustration 1), insert the two 3.2 mm Threaded Drill Guides (with red markings) through the holes in the proximal and distal arms of the Compression/Distraction Device, and thread the guides into the plate holes directly above and below the slotted hole (see illustration 2). 2 Step 11 Fixation Pin Insertion Insert a 4.0 threaded fixation pin (28.14.140) into the middle of the slotted hole on the tibial part of the plate (see illustration 2) until bicortical fixation is achieved. Step 12 Joint Compression Compress the joint by using the Hinge Screwdriver to turn the bolt clockwise on the distal end of the Compression/Distraction Device (see illustration 3/4). Use image intensification to assess the progress of the compression. Note: Be careful to ensure that the desired position of the arthrodesis is maintained during compression. In particular, avoid drifting of the hindfoot into excessive valgus which may create a valgus orientation in the construct. Congruent preparation of the joint surfaces will aid in maintaining the desired position. Note: The middle pin position provides the possibility to distract prior to compression, which allows additional joint preparation if necessary. 3 4 Option for Distraction Compression 4

Step 13 Proximal Screw Fixation Once adequate compression has been achieved, drill, measure, and insert locking screws in the plate in the same manner as with the distal screws for: Ankle Fix insert screws in the tibial part Ankle Fix Plus insert screws in the talus and tibial part For tibial screws, use the 3.2 mm instruments (with red markings). After achieving adequate fixation, remove the fixation pin and the Compression/Distraction Device. Then insert locking screws into the remaining tibial holes. For improved stabilization, always insert a standard screw in the fixation pin hole. Note: Only standard screws may be used in the slotted hole. Before Compression Device removal After Compression Device removal Step 14 Wound Closure and Dressing Use image intensification to confirm adequate plate and screw placement. Then close the wound in layers, and apply a cast in the usual manner. Postoperative Treatment Postoperatively the limb is elevated in a back slab plaster cast for the first two weeks. A wound check is performed at two weeks, and if the wound is healing, a new cast or boot is applied with the patient allowed to partially weight bear as dictated by the strength of the bone and the fixation at the time of the surgery. At 6-8 weeks post-op, the cast is removed (an X-ray may be performed at this stage depending on surgeon preference), and the patient may then commence full weight bearing in a removable boot or cast. At 12 weeks post-op, an X-ray is taken, and if healing is established, the patient may fully weight bear without support. Implant Removal There is no need to routinely remove the implant or any screws once bony consolidation is confirmed. If the hardware is causing tendon or soft tissue irritation, then removal may be carried out, but care must be taken to confirm that the underlying joint is completely consolidated with bone. This step may require a CT scan. If there is no irritation, then the plate and screws should remain in the bone indefinitely. 5

Ordering Information Ankle Fix Ankle Fix Plus Ankle Fix System 4.0 Implant Kit ST-5885-280-50 Titanium Ankle Fix Plates 4.0 mm Plate profile = 3.0 3.5 mm Tibia-Talus Fusion Cat.No. Description Basic Set 28.14.101 Ankle Fix titanium plate, Standard, left 1 28.14.102 Ankle Fix titanium plate, Standard, right 1 28.14.103 Ankle Fix titanium plate, Large, left 1 28.14.104 Ankle Fix titanium plate, Large, right 1 Ankle Fix Tibia-Talus-Calcaneus Fusion Cat.No. Description Basic Set 28.14.105 Ankle Fix Plus titanium plate, Standard, left 1 28.14.106 Ankle Fix Plus titanium plate, Standard, right 1 28.14.107 Ankle Fix Plus titanium plate, Large, left 1 28.14.108 Ankle Fix Plus titanium plate, Large, right 1 Ankle Fix Plus 67 mm 67 mm 67 mm 67 mm 21 mm 22 mm 20 mm 21 mm Standard Large 22 mm 25 mm Titanium screws for osteosynthesis 4.0 mm Locking Screws 4.0 mm, TX 10 Standard Screws 4.0 mm, TX 10 Standard Cat.No. Description Basic Set Cat.No. Description Basic Set 28.30.018 18 mm 10 28.30.118 18 mm 5 28.30.020 20 mm 10 28.30.120 20 mm 5 28.30.022 22 mm 10 28.30.122 22 mm 5 28.30.024 24 mm 10 28.30.124 24 mm 5 28.30.026 26 mm 10 28.30.126 26 mm 5 28.30.028 28 mm 10 28.30.128 28 mm 5 28.30.030 30 mm 10 28.30.130 30 mm 5 28.30.032 32 mm 10 28.30.132 32 mm 5 28.30.034 34 mm 5 28.30.134 34 mm 5 28.30.036 36 mm 5 28.30.136 36 mm 5 28.30.038 38 mm 5 28.30.138 38 mm 5 28.30.040 40 mm 5 28.30.140 40 mm 5 28.30.042 42 mm 5 28.30.142 42 mm 5 28.30.044 44 mm 5 28.30.144 44 mm 5 28.30.046 46 mm 5 28.30.146 46 mm 5 28.30.048 48 mm 5 28.30.148 48 mm 5 28.30.050 50 mm 5 28.30.150 50 mm 5 28.30.055 55 mm 5 28.30.155 55 mm 5 Large 6

Ankle Fix System 4.0 Complete Quad-paq Tray KT-5885-280-50 Instruments and Storage Trays Cat.No. Description Basic Set 508004275 Quad-paq instrument tray for Ankle Fix System 4.0, w/o instruments 1 508002000 Quad-paq tray for implant modules w/ 4 lids, w/o implant modules 1 508005012 Quad-paq Ankle Fix plate-tray system 4.0, w/o implants 1 508005013 Quad-paq Ankle Fix Plus plate-tray system 4.0, w/o implants 1 508005016 Quad-paq Ankle Fix screw tray system 4.0, 34-55 mm locking, w/o implants 1 508005017 Quad-paq Ankle Fix screw tray system 4.0, 34-55 mm standard, w/o implants 1 508003009 Quad-paq Ankle Fix screw tray system 4.0 18-32 mm, w/o implants 1 28.14.000 Compression/Distraction device for Ankle Fix System, 0-15 mm 1 28.14.100 Hinge blade HEX 5 for 28.14.000, 112 mm, AO-style shaft 1 28.14.140* Pin with screw thread 4.0 for 28.14.000, 140 mm, AO-style shaft 2 503004680 Silicone ratchet T-handle, black, cannulated, AO-style connection 1 503004660 Silicone ratchet handle straight, black, non-cannulated, AO-style connection 1 503004187 Screwdriver blade TX 10, 90 mm, non-cannulated, AO-style shaft 2 503004046 Drill guide for drill 2.7, threaded tip, 65 mm, black marker 3 503004047 Drill guide for drill 3.2, threaded tip, 65 mm, red marker 3 502015217 Twist drill 2.7 x 125 mm, for 4.0 mm screws, AO-style shaft, black marker 2 502015650 Twist drill 3.2 x 145 mm, for 4.0 mm screws, AO-style shaft, red marker 2 503004262 Depth gauge 60 mm, round, for 2.3 4.5 mm screws 1 503004250 Titanium plate and screw holding forceps, angled, 150 mm 1 605202150* K-wire 150 x 2.0 mm, trocar/trocar, 10/Pack 1 * Disposable Instrument 7

Developed in cooperation with Dr. Mark Davies and Dr. Chris Blundell, Sheffield, UK. Text, pictures and x-rays by courtesy of Dr. Mark Davies and Dr. Chris Blundell, Sheffield, UK. Note: Zimmer is not affiliated with AO. DISCLAIMER: This documentation is intended exclusively for physicians and is not intended for laypersons. Information on the products and procedures contained in this document is of a general nature and does not represent and does not constitute medical advice or recommendations. Because this information does not purport to constitute any diagnostic or therapeutic statement with regard to any individual medical case, each patient must be examined and advised individually, and this document does not replace the need for such examination and/or advise in whole or in part. Please refer to the package inserts for important product information, including, but not limited to, indications, contraindications, warnings, precautions, and adverse effects. Contact your Zimmer representative or visit us at www.zimmer.com The CE mark is valid only if it is also printed on the product label. 97-8779-013-00 MC0000112223 05-07-2015 Printed in USA 2015 Zimmer, Inc.