Fire-Retardant-Treated (FRT) Plywood



Similar documents
HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Wood use in Type I and II (noncombustible) construction

Certification: Building Plans Examiner. Exam ID: B3

CHAPTER 6 CONSTRUCTION TYPES

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Flame Spread Performance of Wood Products

Building Code Clarifications - 7. Fire Resistance

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Excerpts from the Canadian National Building Code (NBC)

FIRE AND SMOKE PROTECTION FEATURES

Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

Residential Deck Safety, Construction, and Repair

FIRE AND SMOKE PROTECTION FEATURES

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

SUPERIOR FIRE RESISTANCE

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

COMMONLY USED RESIDENTIAL BUILDING CODES

Solar America Board for Codes and Standards

FIRE-RESISTANCE-RATED CONSTRUCTION

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 199

Owner s Guide to Understanding Checks in Glued Laminated Timber

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Load-Span Tables for PS-1 Plywood

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

FIRE-RESISTANCE-RATED CONSTRUCTION

ATI Evaluation Service A Division of Architectural Testing Certification Services

Underwriters Laboratories Testing Information

A Guide to Detached Residential Garages and Residential Workshops (based on 2006 BCBC)

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

Fire Testing of Recycled Materials for Building Applications

Designing for Fire Protection

M E M O R A N D U M. To: Partnership for Safer Buildings Date: 21 March 2003

DRICON FIRE RETARDANT TREATED WOOD APPLICATION GUIDE

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

B. Related categories: The following categories contain requirements that relate to this section:

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

Meeting the Fire Code with Continuous Foam Plastic Insulation

LP OSB Sheathing & Structural 1 Sheathing

Discipline: Structural Issued

H-Stud Area Separation Wall System

Classroom Door Security & Locking Hardware

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Fiberglas, Exterior Wall Thermal Insulation

4 Installation Requirements

GYPSUM AREA SEPARATION FIREWALLS GA

EcoTouch Insulation with PureFiber Technology

Glulam Appearance Classifications for Construction Applications

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

Executive Summary Inclusion of Current Firewall Requirements in NBCC

GreenGuard Housewrap Installation Guide

STANDARD OPEN PATIO COVER

Errata has been identified as follows:

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Chapter 3 Pre-Installation, Foundations and Piers

POST AND FRAME STRUCTURES (Pole Barns)

General Fire Code Requirements Within Commercial Tenant Spaces

City of Riverside Building & Safety Division Phone: (951)

Patio Covers / Carports

COMMON FOR ARCHITECTS AND ENGINEERS Excerpts from HB 2284, 82 nd R

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

Residential Decks. Planning and Development Services Department

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

Asphalt Shingle Application Requirements

Tremco Fire Protection Systems Group Technical Bulletin

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

SUBCHAPTER 5 FIRE PROTECTION CONSTRUCTION REQUIREMENTS

Chapter NORTH LIBERTY BUILDING CODE International Building Codes adopted.

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

CHAPTER 7: Building Systems ROOFING SYSTEMS

Dollars & Sense of Compliance!

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

(800) (562) A Subsidiary of the International Code Council *Revised April 2014

BUILDING SAFETY UNIT

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

ICC-ES Evaluation Report

Uncovered Decks & Porches

Fire-Rated Glass and Glazing START

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Standard from CSI Part Section Format For Wood Framing For Metal Framing For Gypsum Sheathing

Handling, Erection and Bracing of Wood Trusses

Gypsum Board Systems Manual

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

PART 1 GENERAL 1.1 SECTION INCLUDES

ISO Types 1-6: Construction Code Descriptions

TAX APPRAISAL DISTRICT OF BELL COUNTY STORES & COMMERCIAL IMPROVEMENT CLASSIFICATION GUIDE

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.

Transcription:

T e c h n i c a l n o t e Fire-Retardant-Treated (FRT) Plywood Number K320 January 2009 Introduction Codes assure fire safety by controlling such things as size and design of the structure and flame-spread and fire burnthrough resistance of the components used in structural systems. While FRT plywood is classified by the codes as a combustible material, its low flame spread characteristics have led to building code provisions that safely allow FRT plywood to be used in certain applications in buildings otherwise required to be of noncombustible construction. Fire-retardant-treated plywood or lumber is pressure-impregnated with chemicals to permanently inhibit combustion. This qualifies it for a lower flame-spread rating (at least as low as gypsum wallboard) and smoke developed index, and reduces its fire-hazard classification. When it is identified as such by a code-recognized testing agency label, it is rated on parity with noncombustible construction by many insurance rating bureaus. The required treating standards and locations within the building codes where the standards are referenced, as well as where fire-retardant-treated FRT plywood can be safely used, are outlined in this document. Currently, there is no standard for FRT oriented strand board (OSB). Construction Types The stated purpose of the International Building Code (IBC) is to safeguard public health and safety. To keep buildings on parity with one another, the IBC has established five building types and numerous occupancy classifications based mainly on material usage and fire safety. It thus sets allowable heights and areas for the buildings based on these occupancy classes and building types. Building Types I and II are called noncombustible (usually steel and concrete) and are typically the most expensive of the five types. They allow the largest areas. Fire-retardant-treated wood and Heavy Timber construction are allowed limited use in Type I and II as noted in the code. Often, Heavy Timber design is used where the beauty of exposed wood is used to enhance the appearance. Depending on the design, Building Types IIIA and IV are usually less expensive to construct than Types I and II. The interior walls, floors and roofs can be conventional untreated wood. Noncombustible exterior walls are required for these building types. The IBC, however, allows fire-retardant-treated wood for exterior walls as an option if the designer chooses to use wood walls.

2 Building Type V (often called wood frame) is typically the least expensive of the five building types particularly when load-bearing walls are used. Type V construction allows regular, untreated wood throughout the structure. While the basic allowable areas are smaller than for other building types of construction, the use of fire sprinklers, set-backs and hourly rated walls, floors and roofs (along with other factors) can permit area increases that are quite significant. For instance, IBC Table 503 shows a basic area of 18,500 square feet for Occupancy Group E (education) of Type V-A construction. Permissible area increases detailed in IBC Sections 503 through 507, however, can result in one-story Type V educational buildings up to 87,875 square feet in area and two-story schools can be up to 138,750 square feet. Fire-Retardant Treated Ply wood Fire-retardant-treated wood is defined in Section 2303.2 of the 2006 IBC as any wood product which, when impregnated with chemicals by a pressure process or other means during manufacture, shall have, when tested in accordance with ASTM E 84, a listed flame-spread index of 25 or less and show no evidence of significant progressive combustion when the test is continued for an additional 20-minute period. In addition, the flame front shall not progress more than 10.5 feet (3200 mm) beyond the centerline of the burners at any time during the test. The ASTM E 84 test is also called The Tunnel Test because the test material is suspended from the lid of a test chamber that is approximately 25 feet long by one foot high and 1-1/2 feet wide. A standard gas flame, driven by a standard air flow, moves the flame front along the bottom surface of the mounted test material. The progress of the flame front of the test material is compared with the progress of the flame front on red oak. The test material is given a rating of 100 if the distance is the same as on the red oak. From the test results, materials are assigned a Flame Spread Index that is defined in IBC Section 802 as a comparative measure, expressed as a dimensionless number, derived from visual measurements of the spread of flame versus time for a material tested in accordance with ASTM E 84. The flame spread classifications given in IBC Section 803 are: Class A: Flame spread 0-25; smoke-developed 0-450. Class B: Flame spread 26-75; smoke-developed 0-450. Class C: Flame spread 76-200; smoke-developed 0-450. The fire-retardant pressure treatment of FRT plywood is performed in accordance with Standard U1, Commodity Specification H, as published by American Wood Protection Association (AWPA). FA STENERS FOR FIRE-RETARDANT-TREATED PLY WOOD Section 2304.9.5 of the IBC and Section R319.3 of the IRC require hot-dip zinc-coated steel, stainless steel, silicon bronze or copper fasteners in accordance with ASTM A 153 or ASTM B 695, Class 55 minimum (except for bolts 1/2-inch diameter or larger).

3 Burn-Through Resistance and Design Capacities of FRT Wood While fire-retardant treatment of wood inhibits the ability of flames to spread across the surface of the wood product, fire retardants do not reduce the rate at which wood degrades through its thickness when subjected to an elevated heat source. Therefore fire-retardant treatments do not improve the fire endurance rating of a fire-rated assembly, such as a one-hour wall, to any significant extent; nor will FRT plywood take the place of gypsum wallboard in listed fire-rated assemblies. In addition, the treatment process itself may require a modification of the design capacities of the treated plywood. IBC Sections 2303.2.2.1 and 2303.2.2.2 require that the effect of treatment and the method of redrying after treatment, and exposure to high temperatures and high humidities on the flexure properties of fire-retardant-treated softwood plywood shall be determined in accordance with ASTM D 5516. The test data developed by ASTM D 5516 shall be used to develop adjustment factors, maximum loads and spans, or both, for untreated plywood design values in accordance with ASTM D 6305. Each manufacturer shall publish the allowable maximum loads and spans for service as floor and roof sheathing for its treatment. It should be noted that the manufacturer in this case is the treater of the plywood, not the manufacturer of untreated plywood. The treatment processes used are mostly proprietary and the manufacturers of the untreated plywood have no knowledge or control over the treatment process or whether the panels shipped from their mills will ultimately be treated. Treating Process and Test Standards FRT plywood involves treating plywood with chemicals in accordance with the AWPA Standard U1. The FRT treating process is a secondary step accomplished after manufacturing of the plywood and therefore involves proprietary treating and redrying processes, evaluation, quality assurance and product labeling that are conducted by treating companies. Treating companies and their certification agencies evaluate FRT plywood for properties that influence their flame spread characteristics, structural performance and other properties that influence the performance of the products in construction uses. Model codes recognize only FRT plywood that is labeled by independent certification agencies that provide inspection and testing services. This certification is separate from the APA trademark that is applied to the untreated plywood prior to leaving the plywood manufacturing plant. The FRT treating and redrying process may affect properties such as structural capabilities, hygroscopicity (moisture content at a stable humidity) and corrosiveness of the finished products to fasteners and hanger hardware. Test methods and standards published by ASTM and AWPA are used to evaluate these mechanical and corrosiveness properties of FRT plywood. Information on the effect of treatment on the structural capacities of plywood is available from FRT plywood treaters. The International Code Council Evaluation Service, Inc. (ICC-ES) publishes Acceptance Criteria AC66, Acceptance Criteria for Fire-Retardant-Treated Wood, as a basis for defining the necessary technical evaluation to assess the properties and performance of FRT wood products. Manufacturers that have had their products evaluated in accordance with AC66 can be found from the evaluation reports published at the ICC-ES web site (www.icc-es.org). Since the FRT treating and redrying processes may affect the structural performance of plywood, APA Span Ratings and load capacities that apply to untreated plywood may not apply following fire-retardant treating. Obtain structural performance characteristics of FRT plywood from the company providing the treatment and redrying process.

Table 1 Code References Where FRT May Be Used in Lieu of Noncombustible Materials 1 Location Construction Type IBC, IRC or M 2 Section Location Kiosks I, II, III & IV 402.10.1.1.1 Malls Children s Playground May be used when structures exceed 10 feet in U 402.11.1.1 Structures height AND 150 square feet in area. Canopies IV 406.5.2 Over fuel pumps Platforms-permanent I, II & IV 410.4 Where platforms are not more than 30 inches above the main floor AND not more than 1/3 the area of the room AND not more than 3,000 square feet in area. Wall framing III 602.3 FRT permitted within exterior wall assemblies with a 2-hour rating or less. Exterior wall assemblies IV 610.4 FRT framing permitted within exterior wall assemblies with a 2-hour rating or less. Partition-nonbearing I & II 603.1.1.1.1 Where the required fire-resistance rating is 2 hours or less. Exterior wall assemblies I & II 603.1.1.1.2 Nonbearing - where no fire rating is required. Including girders, trusses framing and decking. Roof constructions I & II 603.1.1.3 Partitions I & II 603.1.8 Unprotected roof members I, II, III & V Table 601, footnote c Projections I, II, III & IV 704.2.3 Parapets exterior wall Parapets - roof III, IV & V III, IV & V 704.11.5.5.1, R317.2.2.2 705.6.4.3, R317.2.2 Walls and ceilings III & V 803.4.2 Veneers exterior (sidings) I, II, III & IV 1405.4.1 Trim - exterior I, II, III & IV 1406.2.2 Porches, decks, balconies and stairways - exterior I & II 1406.3.1 Bay Windows I, II, III & IV 1406.4 EXCEPTION: In Type I Construction exceeding two stories in height, FRT is not permitted in roof construction when the vertical distance from the upper floor to the roof is less than 20 feet. Dividing portions of stores, offices or similar places, occupied by only one tenant, do not establish a corridor and have an occupant load of 30 or less. May be FRT when every part of roof construction is at least 20 feet above any floor immediately below it (EXCEPT in F-1, H, M and S-1 Occupancies). FRT projections permitted where openings are not permitted or protection of openings is required. Not required where exterior wall terminates at the underside of the roof sheathing or deck in Type III, IV and V construction provided that deck or sheathing is FRT for a distance of 4 feet. R-2 and R-3 with Class C roof covering. Not required where wall terminates at the underside of combustible roof sheathing or deck in provided that deck or sheathing is FRT for a distance of 4 feet on both sides. May be FRT in lieu of fire-resistance rated or noncombustible construction. FRT veneers (sidings) may be used on buildings up to 4 stories in height. May exceed 10% of wall area even when separation distance is 5 feet or less. Balconies, porches, decks and exterior stairways in buildings 3 stories or less may be FRT provided they are not used as required exits. FRT construction permitted in buildings of 3 stories or less. Pedestrian Walkway I & II 3104.3.2 Roof may be FRT per Table 601, Note c. Solar collector mounts 2 All M3201.2.2 FRT may be used. 1 Based on the 2006 IBC and 2006 IRC. Always check code references and with local building officials prior to construction. Other modification language in the local codes may alter applicability. 2 Based on the 2006 International Mechanical Code

5 Table 2 Code Locations for Applicable Standards 1 IBC/IRC Section Treating/Test Standard(s) Referenced 2303.2 ASTM E 84 (flame spread) 2303.2.1 ASTM D 2898 (weathering) 2303.2.2.1, R802.1.3.2.1 ASTM D 5516, ASTM D 6305 (panel tests) 2303.2.2.2, R802.1.3.2.2 ASTM D 5664, ASTM D 6841 (lumber tests) 2303.2.3, R802.1.3.1, R802.1.3.3 ASTM D 2898 (weathering) 2303.2.4, R802.1.3.4 ASTM D 3201 (hygroscopic properties) 2304.9.5, R319.3, R803.2.1.2 ASTM A 153, ASTM B 695 (fasteners) 1 Based on the 2006 IBC and 2006 IRC. Always check code references and with local building officials prior to construction. Other modification language in the local codes may alter applicability. Code-Approved Applications for FRT Ply wood The following provisions permitting the use of FRT plywood in noncombustible structures and in lieu of noncombustible construction materials are provided in the IBC and the International Residential Code (IRC). Verify the correct application of FRT plywood with your local building code department. Identification of Fire-Retardant-Treated Ply wood IBC Section 2303.2.1 requires that FRT plywood be labeled by the company that treats the plywood and that the label shall contain the following information: 1. The identification mark of an approved agency in accordance with IBC Section 1703.5. 2. Identification of the treating manufacturer. 3. The name of the fire-retardant treatment. 4. The species of wood treated. 5. Flame spread index and smoke developed index. 6. Method of drying after treatment. 7. Conformance with appropriate standards in accordance with IBC Sections 2303.2.2 through 2303.2.5. 8. For fire-retardant-treated wood exposed to weather, damp or wet locations, the words of No increase in the listed classification when subjected to the Standard Rain Test (ASTM D 2898), must be included. Conc lusion FRT plywood can be used in a variety of code-permitted applications. FRT plywood, however, is fire-retardant-treated subsequent to manufacture at the plywood mill. The plywood manufacturer has no knowledge of, nor responsibility for, the treated product or its subsequent performance. The required treater's marks are applied by the treater at the treating plant and are completely separate from the APA trademark.

6 All FRT plywood shall be properly labeled with the identifying mark of an approved testing agency, identification of the treating manufacturer, name of fire-retardant treatment, wood species, flame spread index and smoke developed index, drying method used after treatment and conformance with appropriate standards as required by Sections 2303.2.2 through 2303.2.5 of the IBC and R319.3 of the International Residential Code (IRC). Consult with the individual manufacturers of FRT chemicals and treaters for FRT plywood design information or questions. References American Society for Testing and Materials, Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware, ASTM A 153/A153M-05, Annual Book of ASTM Standards, West Conshohocken, PA American Society for Testing and Materials, Specification for Zinc Mechanically Deposited on Iron and Steel, ASTM B 695-04, Annual Book of ASTM Standards, West Conshohocken, PA American Society for Testing and Materials, Test Methods for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing, ASTM D 2898-08, Annual Book of ASTM Standards, West Conshohocken, PA American Society for Testing and Materials, Test Method for Hygroscopic Properties of Fire-Retardant Treated Wood and Wood-Based Products, ASTM D 3201-08a, Annual Book of ASTM Standards, West Conshohocken, PA American Society for Testing and Materials, Test Method of Evaluating the Flexural Properties of Fire-Retardant Treated Softwood Plywood Exposed to Elevated Temperatures, ASTM D 5516-03, Annual Book of ASTM Standards, West Conshohocken, PA American Society for Testing and Materials, Test Methods of Evaluating the Effects of Fire-Retardant Treatment and Elevated Temperatures on Strength Properties of Fire-Retardant Treated Lumber, ASTM D 5664-08, Annual Book of ASTM Standards, West Conshohocken, PA American Society for Testing and Materials, Practice for Calculating Bending Strength Design Adjustment Factors for Fire- Retardant-Treated Plywood Roof Sheathing, ASTM D 6305-08, Annual Book of ASTM Standards, West Conshohocken, PA American Society for Testing and Materials, Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-Retardant-Treated Lumber, ASTM D 6841-08, Annual Book of ASTM Standards, West Conshohocken, PA American Society for Testing and Materials, Test Methods for Surface Burning Characteristics of Building Materials, ASTM E 84-08a, Annual Book of ASTM Standards, West Conshohocken, PA International Code Council Evaluation Service, Acceptance Criteria for Fire-Retardant-Treated Wood, AC66, February 2007, ICC-ES, Whittier, CA International Code Council, International Building Code, 2006, Country Club Hills, IL International Code Council, International Residential Code, 2006, Country Club Hills, IL International Code Council, International Mechanical Code, 2006, Country Club Hills, IL

We have field representatives in many major U.S. cities and in Canada who can help answer questions involving APA trademarked products. For additional assistance in specifying engineered wood products, contact us: APA Headquarters 7011 So. 19th St. Tacoma, Washington 98466 (253) 565-6600 Fax: (253) 565-7265 Product Support HELP Desk (253) 620-7400 E-mail Address: help@apawood.org Disclaimer The information contained herein is based on APA The Engineered Wood Association s continuing programs of laboratory testing, product research and comprehensive field experience. Neither APA, nor its members make any warranty, expressed or implied, or assume any legal liability or responsibility for the use, application of, and/or reference to opinions, findings, conclusions or recommendations included in this publication. Consult your local jurisdiction or design professional to assure compliance with code, construction and performance requirements. Because APA has no control over quality of workmanship or the conditions under which engineered wood products are used, it cannot accept responsibility for product performance or designs as actually constructed. Form No. K320/Issued January 2009