Repeaters and Mimics Data Sheet



Similar documents
Emergency Voice Communication Systems EVCS Network 8 Data Sheet

FIREDEX Conventional Fire Panels

Conventional Fire Detection and Extinguishant Control System Specification

CB200W Water Leak Detection Panel Application Guide

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

VEGA Analogue Addressable Control Panels

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Telephone- and leased line modem for industrial applications TD-36

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

AIS750 Series Alarm Annunciator

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Electronic Control Devices The European Product Catalogue 2007

In-Sight Hardware specifications

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~

ICP-CP500. User's Guide ICP-CP500 Codepads

EBDSPIR-PRM, EBDSPIR-PRM-IP

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

SECTION DETECTION AND ALARM

Rack mounted telephone- and leased line modem for industrial applications

Product Information Sheet UH36 Hi Pot Tester

COMPALARM AP GENERAL MAIN FEATURES

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

OZW30. Central Unit SYNERGYR

3500/93 System Display

HMI display Installation Guide

PD 100A. Printing data system

DC Electronic Loads 8500 series

EN54-16 Voice Alarm System PRODUCT DATASHEETS

Premier M Plus & Infinity 8

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Communication A BRITISH MANUFACTURER. Features:

TMS TANK MANAGEMENT SYSTEM

GST301. (Single Protection Zone) Operation Manual

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

T a b l e o f C o n t e n t s

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Always on the Lookout Perfect Protection against Burglary

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Model: DC-A2IO Advanced HVAC Controller

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

UniOP epad33 and epad33t

Temperature & Humidity SMS Alert Controller

Industrial 1 Port RS232/422/485 to Dual Ethernet Serial Device Server

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by

I STAR COMPUTER CO., LTD

1 Serial RS232 to Ethernet Adapter Installation Guide

OPAL TM Detector range

A-307. Mobile Data Terminal. Android OS Platform Datasheet

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

welcome to our world fire alarm systems - series 600

4-Channel Thermometer / Datalogger

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

AC-115 Compact Networked Single Door Controller. Installation and User Manual

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Product Data Sheet. User Manual. User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

Product Information Fire alarm panel 8000 C

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

HDMI Matrix Switch USER MANUAL VM0404H

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Digital input modules

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

TX OPEN RS232/485 module

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

500r+ Installation and User Guide

Power Meter Series 700

PROTEC CIRRUS HYBRID ASPIRATING SMOKE DETECTION SYSTEMS

Notifier by Honeywell: Voice Alarm Solutions

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

PIEZOMETER AIRFLOW MEASURING RING

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

HCR3.2/.. Chipcard reader HOTEL SOLUTION

IntesisBox KNX Mitsubishi Heavy Industries AC

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Duct Humidity Transmitter

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Electronic Control Devices The European Product Catalogue 2007

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

ACTIVE 5 ENGINEERING MANUAL

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

Transcription:

Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel. By placing them at strategic points in a facility such as nurse stations, floor landings, gatehouse or control rooms valuable time can be saved when identifying the location of a fire and/or evacuating the building. IDR Series Repeater Panels The IDR series repeater panels combine a compact design with a 2 x 40 character or a 240 x 64 pixel graphics LCD. The LCD replicates the display on the ID panels, and utilises the same simple menu-driven user interface as the host panel. The control buttons and navigation keys on the repeaters provide the operator with the ability to navigate through the menu options and event displays. The nine LED indicators provide a quick summary of the general system status for the user. The compact design makes it very easy to install and commission the IDR Series repeaters. The repeater s event log can store up to 150 most recent events. Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows based off-line configuration tool IDR Series Mimics IDR series mimic systems, when used in conjunction with site plans, allow fast identification of the location of a potential fire at locations away from the the main fire alarm control panel. The incident can be quickly investigated by the building occupants and such displays allow fire services attending an incident to quickly evaluate the situation and respond accordingly. Compatible with Notifier ID50/60 series, ID2000 and ID3000 Fire Control Panels Only one PCB board required for each 16 LEDs/outputs Main board extensible by adding up to 9 further expansion boards each with 16 outputs per board Provides up to 160 total configurable outputs Standard or configurable settings Easy DIP switch addressing Available with off-line Configuration Tool RS485 communications This document is not intended to be used for installation purposes. Every care has been taken in the preparation of this document but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. For more information, contact: NOTIFIER. Charles Avenue, Burgess Hill, West Sussex, RH15 9UF. United Kingdom Phone: +44 (0) 1444 230 300 Fax: +44 (0) 1444 230 888 Page 1 of 7-990-156_0511 ISO9001 Design, Manufacture and Supply to Quality Management Systems Certified to ISO9001:1994

IDR-2P Passive Repeater The IDR2P passive repeater is an indication only repeater. The back lit LCD and the common system status LED s follow the indication on the main fire alarm panel. Furthermore the IDR2P passive repeater has configuration and test functions such as Lamp Test, LCD Test, and Buzzer Test. The nine LED indicators provide a quick summary of the general system status for the user. The compact design makes it very easy to install and commission the IDR Series repeaters. The repeater s event log can store up to 150 most recent events; this also aids commissioning. Passive Repeater IDR-2P (002-451) Dimensions Weight: Material: 165 mm 254 mm 50 mm 1.7 Kg (approx) Mild steel sheet enclosure Max Wire Gauge for Terminals: 0.5mm 2 to 2.5mm 2 Quiescent Current: Alarm Current: Communications medium: 18-32V dc 120mA (-2P/-2A),155mA (-6A). Address Range Switch-selectable in range 0-31 (0 is unmonitored and must not be used except during power-up commissioning check) RS485 isolated serial port Isolation Baud rate Connector Screw terminals on board Maximum cable length: 3000m (minimum of 1mm 2 screened cable recommended) Bezel Kit (option) Operating temperature range: Humidity: 5 to 95% relative humidity (non-condensing) Panel Sealing: IP 30, (EN 60529) Vibration: EN 60068-2-6, 10-150Hz at 0.981ms-2 (Meets the requirements of EN 54-2/4) Page 2 of 7-990-156_0511

IDR-2A Active Repeater The IDR2A active repeater will repeat the LCD & LED indications on the main fire alarm panel and allow the operator to command the system, using system control pushbuttons (Mute Buzzer, Accept, Evacuate, Silence Sounders, Resound Sounders and Reset). Furthermore, the IDR2A has configuration and test functions such as edit Normal message, Lamp Test, LCD Test, Buzzer Test and a Pushbutton Test option. For added security, a keyswitch on the front of the repeater enables/disables certain push buttons. The nine LED indicators provide a quick summary of the general system status for the user. The compact design makes it very easy to install and commission the IDR Series repeaters. The repeater s event log can store up to 150 most recent events; this also aids commissioning. Active Repeater IDR-2A (002-450) Dimensions Weight: Material: 165 mm 254 mm 50 mm 1.7 Kg (approx) Mild steel sheet enclosure Max Wire Gauge for Terminals: 0.5mm 2 to 2.5mm 2 Quiescent Current: Alarm Current: Communications medium: 18-32V dc 120mA (-2P/-2A),155mA (-6A). Address Range Switch-selectable in range 0-31 (0 is unmonitored and must not be used except during power-up commissioning check) RS485 isolated serial port Isolation Baud rate Connector Screw terminals on board Maximum cable length: 3000m (minimum of 1mm 2 screened cable recommended) Bezel Kit (option) Operating temperature range: Humidity: 5 to 95% relative humidity (non-condensing) Panel Sealing: IP 30, (EN 60529) Vibration: EN 60068-2-6, 10-150Hz at 0.981ms-2 (Meets the requirements of EN 54-2/4) Page 3 of 7-990-156_0511

IDR-6A Active Repeater The IDR6A active repeater panel combines a compact design with a 240 x 64 pixel graphic backlit LCD and system control pushbuttons. The large LCD replicates the display on the ID3000 panel and utilises the same simple menu-driven user interface as the ID3000 panel. The control buttons and navigation keys on the repeater provide the operator with the ability to navigate through menu options and event displays. Furthermore it allows the user to remotely reset the system, accept events, silence sounders, resound sounders, initiate evacuation and to run diagnostics tests on the repeater. For added security, a keyswitch on the front of the repeater enables/disables certain pushbuttons. The nine LED indicators provide a quick summary of the general system status for the user. The compact design makes it very easy to install and commission the IDR Series repeaters. The repeater s event log can store up to 150 most recent events; this also aids commissioning. Active Repeater IDR-6A (002-452) Dimensions Weight: Material: 165 mm 254 mm 50 mm 1.7 Kg (approx) Mild steel sheet enclosure Max Wire Gauge for Terminals: 0.5mm 2 to 2.5mm 2 Quiescent Current: Alarm Current: Communications medium: 18-32V dc 120mA (-2P/-2A),155mA (-6A). Address Range Switch-selectable in range 0-31 (0 is unmonitored and must not be used except during power-up commissioning check) RS485 isolated serial port Isolation Baud rate Connector Screw terminals on board Maximum cable length: 3000m (minimum of 1mm 2 screened cable recommended) Bezel Kit (option) Operating temperature range: Humidity: 5 to 95% relative humidity (non-condensing) Panel Sealing: IP 30, (EN 60529) Vibration: EN 60068-2-6, 10-150Hz at 0.981ms-2 (Meets the requirements of EN 54-2/4) Page 4 of 7-990-156_0511

Mimics IDR-M & IDR-MD The IDR-M and IDR-MD mimic products make up a versatile system where mimic displays are required in association with NOTIFIER fire control panels. Common fire, fault, test and disablement outputs and power OK outputs can be configured in addition to a keyswitch input to enable evacuate, silence, lamp test, mute and reset inputs. The IDR-M Control and Termination kit comprises a Control board and a Termination board co-located on one metal chassis. The Control board contains the processor and memory, and the Termination board allows connection of power, RS485 and other external signals. The Control board communicates with up to eight Mimic Driver boards. IDR-MD Mimic Driver kit comprises a Mimic Driver board and two Mimic Termination boards, each mounted on a discrete metal chassis. Up to eight Mimic Driver boards can be driven by one Control board. Mimics IDR-M & IDR-MD Dimensions - Control or Driver pcb: 45 mm 126 mm 240 mm Dimensions - Mimic Termination pcb: 45 mm 57 mm 203 mm Max wire gauge for terminals: 0.5mm 2 and 2.5mm 2 IDR-M Mimic control Kit Mimic Control board mounted on a discrete metal chassis. The control board communicates with up to eight mimic driver boards. 18-32Vdc Operating Current: Control board: Each driver board: 10mA Each LED: 4.4mA Max. total (Board & 64 LEDs): 265mA Each relay: 80mA Communications Medium: Isolation: Baud Rate: Max. Cable Length: Operating temperature Relative humidity: 3000m RS485 Network Emissions: EN 61000-6-3 15% to 95%, non-condensing IDR-MD Mimic Driver and termination board Kit This comprises a driver board and two termination boards each mounted on to individual metal chassis. Page 5 of 7-990-156_0511

Compact Mimic IDR-CM & IDR-CME The Compact Mimic is an expandable mimic suitable for standard or more complex applications where mimic displays are required in association with NOTIFIER fire control panels. Common fire, fault, test and disablement outputs and power OK outputs can be configured in addition to a keyswitch input to enable evacuate, silence, lamp test, mute and reset inputs. The Compact Mimic has two types of boards: a main board (IDR-CM) and an expansion board (IDR-CME), both of which can have up to 16 configurable outputs. A fully utilized compact mimic system can comprise one main board and up to 9 expansion boards, providing a maximum total of 160 configurable outputs. Compact Mimic IDR-CM & IDR-CME Dimensions IDR-CM Control Board: 25 mm 102 mm 152 mm Dimensions IDR-CME Expansion Board: 25 mm 44 mm 152 mm Max wire gauge for terminals: 0.5mm 2 and 2.5mm 2 The IDR-CM Control Board has provision for General Fault, General Disablement, Power OK, General Fire and Test LEDs. There are 16 LED or relay outputs which can be configured either out-the-box (as all fire or as 8 fire and 8 fault/test/disablement, both starting at a specified zone number) or individually via an Off-line Configuration Tool. Provision is made for Evacuate, Silence Sounders, Lamp Test, Mute Buzzer and Reset pushbuttons and for a level 2 access keyswitch. Expandable with up to 9 additional IDR-CME expansion boards each providing 16 additional configurable outputs, giving a maximum total of 160 configurable outputs Current Consumption: IDR-CM Control board: IDR-CME expansion board: Individual active output current: Configured for LED Configured for relay Communications Medium: Isolation: Baud Rate: Max. Cable Length: 18-30Vdc 35mA max. 0.5mA max. limited to 6mA. maximum 50mA. 3000m RS485 Network Operating temperature Relative humidity: 15% to 95%, non-condensing Page 6 of 7-990-156_0511

Product Range at a Glance Part Number IDR-2P Passive Repeater 002-451 IDR-2A Active Repeater 002-450 IDR-6A Active Repeater 002-452 IDR-M Mimic control PCA Kit 020-573 IDR-MD Mimic Driver and termination board PCA Kit. 020-574 IDR-CM Compact Mimic driver. 020-741 IDR-CME Compact Mimic Expansion board 020-742 Flush Mounting Bezel for IDR Series Repeaters. Black/Grey. H:218mm W:307mm D:60mm. Hole size: H:170mm W:260mm. 020-600-009 IDR6-A Active Repeater. 240 x 60 Graphic LCD STAINLESS STEEL, Flush. Requires external power source and RS485 communication card (to be installed in the panel). H:218mm W:307mm D:60mm. Hole size: H:170mm W:260mm. 002-466 Page 7 of 7-990-156_0511 Charles Avenue Burgess Hill W. Sussex RH15 9UF T: +44 (0) 116 246 2255 F: +44 (0) 116 246 2210 E: sales@notifierfiresystems.co.uk