Passive House Projects in Norway an Overview



Similar documents
The first apartment house renovation with Passive House components in Norway

Case study on residential building renovation and its impact on the energy use and thermal comfort

Klosterenga, Oslo, Norway, page - 1

Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015

Norwegian Tax Authority - Oslo Norway

Extra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes

Passive house rehabilitation of post war residential building in Zug, Switzerland

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

Challenging the possibilities

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Hybrid heat pumps. saving energy and reducing carbon emissions

Energy Efficiency in Buildings

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Parametric Analysis of School Classroom Typologies' Energy Performance

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

Isover Multi-Comfort-House Comfort and Energy Efficiency in Buildings

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ

BPC Green Builders. Green building for new and existing homes. Health Comfort Energy

School in Schwanenstadt, Austria

ENERGY BALANCE OF LOW ENERGY HOUSE WITH GHPS IN HOKKAIDO

Module 3.7. Thermal bridging

3-D Modeller Rendered Visualisations

Energy savings in the residential area are essential in

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Kvernhuset Lower Secondary School

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

Integrated Solar Radiant Systems

Performance of 8 Passive House Envelopes in Cold Climates

BYG DTU. Thermal properties of window frame Type 1 Sheet: 1. Type: Side, top and bottom profile. Source file: Format: dwg/dxf bmp

SENSITIVITY STUDY FOR ARCHITECTURAL DESIGN STRATEGIES OF OFFICE BUILDINGS IN CENTRAL CHILE: EFFECTIVENESS OF NOCTURNAL VENTILATION.

New technical solutions for energy efficient buildings

Directorate for the Built Environment Building Standards Division

RESEARCH HIGHLIGHT. Solar Energy Potential for the Northern Sustainable Houses

BER Assessors Dwellings Technical Bulletin

Rosslare Case Study Passive House Cost Analysis. Seamus Mullins Quantity Surveyor Michael Bennett Group

Improving thermal insulation of concrete sandwich panel buildings

Moisture Content in Insulated Basement Walls

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

FACTSHEET Assessing the Feasibility of Using Solar-Thermal Systems for Your Agricultural or Agri-Food Operation

Twinning «Improvement of the Energy Efficiency in Turkey»

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

Energy audit in Finland

HEATING-COOLING WALL PANELS SYSTEM IN SLOVENE ETHNOGRAPHIC MUSEUM

Solar Heating Basics Page 1. a lot on the shape, colour, and texture of the surrounding

Innovative solution for heat recovery of ventilation air in older apartment buildings - with low intervention affecting the residents

Rainwater Harvesting

Solar Aquaponics Designing a 100% Solar Aquaponics Greenhouse

DISTRIBUTED GENERATION AND ENERGY EFFICIENCY FOR ACHIEVING ENERGY SELF-SUSTAINING INDUSTRIAL AREAS

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Data Collection Summary Report

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Active Roofs and Facades in Sustainable Renovation

RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING

Achieving Net Zero. Bradley Berneche, President Alouette Homes. National Marketing Committee Canadian Home Builders Association Ottawa, June 6, 2008

Climate Change Preparedness and Resiliency Checklist Performance Criteria

Energy Concept and Technology in the Rosenheim Solar Decathlon House

SIP (STRUCTURAL INSULATED PANEL)

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation

Building Integrated Combined Solar Thermal and Electric Generation Demonstration Project at Concordia University

Building Energy Labels: The Swiss MINERGIE Label

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

áååçî~íáîé=äìáäçáåöë

Window Thermal Performance Optimization in Governmental Emirati Housing Prototype in Abu Dhabi, UAE

SAP 2012 IN A NUTSHELL

Each icon on this map represents the physical location of a station.

Adaptive strategies for office spaces in the UK climate

BER Assessors Dwellings Technical Bulletin

Federation of European Heating, Ventilation and Air-conditioning Associations

BEST 3, Atlanta, April 2012 Grahame E. Maisey, P.E.

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

Zero Emission Buildings and Architecture Anne Grete Hestnes

Project Build with CaRe - WP 2 Education and Training

Assessment Methods. 15 th November 2010 Huw Jenkins Simon Lannon

Crawl space heat and moisture behaviour

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

Low energy class 1 typehouses according to the Danish building regulations

1..GENERAL DATA 2. CLIMATIC DATA. Location

Could a European Super Energy Efficient Standard Be Suitable for the U.S.?

Windows are one of the most important components of a

DIETRISOL SOLAR WATER HEATING SYSTEMS ENERGY SAVINGS AND ECOLOGICAL BENEFITS SUSTAINED COMFORT SIMPLICITY AND RELIABILITY INNOVATIVE, MODULAR SYSTEMS

Transcription:

Passive Houses in Cold Climates SESSION 4 Passive House Projects in Norway an Overview Inger Andresen and Tor Helge Dokka, SINTEF Building and Infrastructure Architecture and Building Technology, N-7465 Trondheim, Norway Michael Klinski and Ulla Hahn, Norwegian State Housing Bank Postboks 1243 Vika, N-0110 Oslo, Norway. 1 Introduction During the last 2-3 years, the interest in low energy and passive houses has increased significantly in Norway. More than 15 passive house projects incorporating more than 1000 apartments are currently in the planning phase, but only a few has so far been completed. This paper includes a description of the projects that have been completed and some of the projects that have come furthest in the planning. The projects are located in different climatic zones, ranging from the relatively mild coastal climate of Bergen to the cold inland climate of Lillehammer. The locations span from 58 to 70 degrees Northern latitude. The work is partly carried out within the framework of the European project "Promotion of European Passive Houses" (PEP), financed by the Energy Intelligent Europe programme (www.passivhouses.org). 1.1 Overview of current passive house projects in Norway The table below shows an overview of current passive house projects in Norway. In the following, the projects are described in more detail. Building type Location Client /Developer Architect Energy Engineering Status Single family dwelling Tromsøya, Tromsø Passivhus Norge AS Steinsvik Architects Steinsvik Architects Completed Dec 2005 7 dwellings in a row house Storelva, Tromsø Maurstadgruppen Steinsvik Architects Steinsvik Architects To be completed April 2007 Single family dwelling Sørumsand, Akershus H. Ringstad Dipl. Ing. Stephan Blohm and Arch. Toril R. Grønvold Dipl. Ing. Stephan Blohm, and SINTEF Construction starts April 2007 1 single family dwelling in a row house Venstøp, Skien Hansen & Lauritzen AS T.A. Danielsen, Aplan Viak SINTEF a. Erichsen & Horgen AS Completed Fall 2006 28 apartments in multi-storey blocks Fyllingsdalen Bergen ByBo AS ABO Arkitekter SINTEF Construction starts summer 07 32 apartments in 2 tory row houses Smestadmoe n Lillehammer LOBB housing cooperative Asplan Viak and Kai S. Hekne SINTEF Construction starts spring 07 210 apartments in multi-storey blocks Lerkendal, Trondheim Skanska Bolig Selberg Arkitektkontor AS and Madsø&Sveen SINTEF Construction starts fall 2007 Table 1: Overview of current passive house projects in Norway Bregenz 2007 125

SESSION 4 Passive Houses in Cold Climates 1.1.1 Single family house at Tromsøya, and 7 dwellings at Storelva, Tromsø, latitude 69.6 N Figure 1: Left: Schematic drawing of the technical system of the I-Box concept (illustration by O. K. Steinsvik). Right: Picture of the completed dwelling at Tromsøya (photo by R. Steinsvik) Both these projects are designed according to the I-Box concept from Steinsvik Architects (www.passivhus.no). The single family dwelling at Tromsøya was completed in December 2005, and was the first passive house project to be completed in Norway. The 7 dwellings at Storelva are due to be completed in March/April 2007. Tromsø has a relatively cold coastal climate, with a yearly mean ambient temperature of 3.0 C and design winter temperature of -17.5. The dwellings are constructed in massive wood elements (from KLH Massivholz, Austria). The exterior walls have 25-30 cm of mineral wool, the roof has 36 cm of insulation, and the floor has 15 cm. The ventilation system is coupled to an earth to air tube collector buried beneath the basement and a compact heat pump unit with heat recovery (Vitotres 343 from Viessmann). The dwellings have no conventional heating systems; the entire space heating load is covered by the ventilation system. A solar collector system produces most of the warm water during the spring and summer seasons. The total end energy use is estimated to less than 50 kwh/m2/yr for all dwelling units. The heating energy load for all dwellings is estimated to be below 5 kwh/m2/yr. The developer has estimated the total construction cost of the project to about 10 % above typical construction cost. The indoor temperatures in the dwelling at Tromsøya have been measured during the warmest summer days, and are reported to be in the range of 126 Bregenz 2007

Passive Houses in Cold Climates SESSION 4 22-23 C. The windows are equipped with an exterior automatic shading system. The energy use for the Tromsøya house has not been measured yet, but the all the dwellings are to be monitored. Special challenges reported were lack of knowledge and skills among HVAC and electrical engineers, so the architects were to deal with the technical matters on their own. Also, the special construction method related to the massive wood elements, were new to the Norwegian construction practitioners. However, the thermal bridge challenges related to the massive wood elements were found to be relatively easy to solve. 1.1.2 Single family house (NorOne) at Sørumsand, Akershus, latitude 59.9 N Figure 2: Drawing of the south facade (illustration by Arch. Toril R. Grønvold) Figure 3: Detail of exterior wall meeting ground floor slab (Illustration by Dipl. Ing. Stephan Blohm) The ambition of this project is to be the first dwelling in Norway which is self-sustained with energy over the year. It will also be the first Norwegian project certified by the Passivhaus Institute in Darmstadt. The 3 storey dwelling has a total floor area of 345 m². Sørumsand is located close to Oslo, with a yearly mean ambient temperature of 6.2 C and a winter design temperature of -20 C. Global horizontal solar radiation is 970 kwh/m²/yr. The U- values of the envelope construction are as follows: floor 0.09 W/(m²K), wall 0.11 W/(m²K), roof 0.09 W/(m²K), windows 0.76 W/(m²K). The ventilation system has high-efficient heat recovery and air is preheated via a ground coupled heat exchanger. There will be a water based floor heating system in bathrooms and hallways. LED lighting and A-labelled household appliances as well as a building management system will be installed to reduce the electricity use to a minimum. The house will also be equipped with a roof mounted, grid coupled PV panel of about 5 kwp and vacuum tube solar collectors that produces 2350 kwh/yr for DHW. Auxiliary heating is electrical. The total heating energy and power use is estimated to 14.9 kwh/m²/yr and 9.9 W/m², respectively. Total end energy use is estimated to 62 kwh/m²/yr. The developer has estimated the total construction cost of the project to about 10 % above typical construction cost. Special challenges so far have been difficulties related to finding a suitable, biomass-fired central heating system with low (3-5 kw) output. Bregenz 2007 127

SESSION 4 Passive Houses in Cold Climates 1.1.3 Single family house at Venstøp, Skien, latitude 59.3 N This passive house is part of a 7 house development including 2 low energy houses. The houses were completed in Fall 2006, and monitoring has started. The small town of Skien has a climate typical of the east coast, with a mean annual temperature of 5.6 C and a winter design temperature of 20 C. Global horizontal solar radiation is 930 kwh/m²/yr. The construction of the passive house includes exterior walls and floors with 30 cm of insulation, and 45 cm in the roof. Windows are triple glazed with a U- value of 0.8 W/(m²K). Infiltration rate has been designed to 0.04 ACH using 2 air-tight layers and careful detailing. The house is equipped with a mechanical ventilation system with 80 % heat recovery. The heating system includes water based floor heating in bathrooms. A novel air-to-water heat pump system with an average COP of 3.2 (kw-smart, www.abk.as) provides space and DHW heating. Assuming energy-efficient lights and appliances, the heating energy load was estimated to 22 kwh/m²/yr and the total end energy use was estimated to 64 kwh/m²/yr. Thus, the heating load does not meet the passive house requirement; however the total end energy use is comparable to a passive house. The construction cost of the passive house was 8-10 % higher than the standard houses. Special challenges reported were some extra time spent on fine tuning of the ventilation system during commissioning, and some dew gathering on the exterior surface of the windows during wet and cold mornings and afternoons. 1.1.4 28 apartments at Fyllingsdalen, Bergen, latitude 60.4 N The 28 passive house apartments are planned as a part of a large low energy dwelling complex Løvåshagen with a total of 80 apartments. The construction will start summer 2007. The average size of the apartments is 80 m². Bergen has a relatively mild and moist coastal climate, with a yearly ABO Arkitekter mean ambient temperature of 7.8 C and design winter temperature of -10. Floor slabs are in-situ concrete and exterior walls are wood frame with 35-40 cm of mineral wool. Windows have a U-value of 0.8 W/(m²K) (N-Tech from Nor-Dan). Slab on ground has 35 cm of rigid foam insulation. Thermal bridges are minimized to < 0.02 W(/mK). Air tightness is planned to reach the requirement of n 50 =0.6 ACH. Each apartment has a mechanical ventilation system with 80 % heat recovery (rotary wheel, placed in the 128 Bregenz 2007

Passive Houses in Cold Climates SESSION 4 bathrooms). The apartments have a simplified water based heating system with floor heating in the bathroom and one radiator (800-1000 W) in the living room. Each apartment also has its own solar heating system delivering about 19 kwh/m²/yr. Auxiliary heating energy is supplied by electricity. Heating energy use is estimated to 15 kwh/m²/yr and the total end energy use is estimated to 70 kwh/m²/yr. The developer has estimated the total construction cost of the project to about 1000 NOK/m², which corresponds to about 5-6 % above typical construction cost. 1.1.5 32 apartments at Smestadlunden, Lillehammer, latitude 61.1 N Figure 4: North facade (left) and south facade (east). Illustration: Asplan Viak At the city of Lillehammer, LOBB housing cooperative has planned to build 32 dwellings in 2-storey row houses. The construction will start spring 2007. The average size of the apartments is 90 m². Lillehammer has a cold and relatively dry inland climate, with a yearly mean ambient temperature of 3.3 C and design winter temperature of -25. Floor slabs are in-situ concrete and exterior walls are wood frame with 35-45 cm of mineral wool. Windows have a U-value of 0.8 W/(m²K) (N-Tech from Nor-Dan). Slab on ground has 35 cm of rigid foam insulation and roof has 55 cm of mineral wool. Thermal bridges are minimized to < 0.01 W(/mK). Air tightness is planned to satisfy the requirement of n 50 = 0.6 ACH. The ventilation and heating systems are similar to those of the Løvåshagen project described above. Each apartment also has its own solar heating system delivering about 20 kwh/m ² /yr. Heating energy use is estimated to 15 kwh/m²/yr and the total end energy use is estimated to 70 kwh/m²/yr. The developer has estimated the total construction cost of the project to about 950 NOK/m², which corresponds to about 5-7 % above typical construction cost. 1.1.6 210 apartments at Lerkendal, Trondheim, latitude 63 N In the city of Trondheim, the construction company Skanska is planning a large passive house project consisting of more than 200 apartments. The construction will start in the fall of 2007. The average size of the apartments is 55 m². Trondheim has a yearly mean ambient temperature of 4.9 C and design winter temperature of -19 C. The construction is based on steel columns and pre-cast concrete floors, with exterior walls in either foam insulated concrete sandwich elements or wood frame construction. The roof has 50 cm of mineral wool. Windows have a U-value of 0.8 W/(m²K) (N-Tech from Nor-Dan). Floor towards the parking cellar has 35 cm of insulation. Thermal bridges are minimized to < 0.02 W(/mK). Air tightness is planned to meet the requirement of n 50 = 0.6 ACH. Bregenz 2007 129

SESSION 4 Passive Houses in Cold Climates The heating and ventilation systems are similar to that of the Løvåshagen project described above. Heating energy use is estimated to 15 kwh/m²/yr and the total end energy use is estimated to 85 kwh/m²/yr. All thermal energy is supplied by the district heating system. The developer has the ambition to keep the construction cost equal to their standard construction cost. 1.2 Lessons learned and future prospects The greatest challenges reported are related to finding appropriate energy systems, i.e. there is a lack of efficient energy supply systems based on renewable energy. Also, there seems to be a lack of high-efficient ventilation aggregates. With respect to designing the construction details, the greatest challenge is connected to exterior walls. There is also a lack of standardized design details with respect to minimizing thermal bridges, thus the design of such details is time-consuming. Extra investment costs of the passive house projects range from 0 to 10 % compared to normal standard. The costs seem to increase proportionally with the size of the project, i.e. the highest costs are for the single family houses and the lowest costs are for the larger apartment buildings. Estimated total end energy use ranges from 50 to 85 kwh/m²/yr. However, these numbers are not confirmed, since none of the houses have yet been monitored. Thus, the greatest challenge related to ensuring the further success of passive houses in Norway is to establish some form of organised performance testing or certification scheme. 130 Bregenz 2007