C ertainteed. Concrete Forming and Drainage....It's About Time...Your Time



Similar documents
pvc well casing & drop pipe

Best Basement Water Management Practices

Built to Last. Built for Beauty. Good. Solid. Logix. TM

State of Connecticut Department of Public Health RADON PROGRAM

Foundation Drainage. Gable Roof Runoff. Hip roof Runoff. By: Brent Anderson, P.E. Moisture Control Engineering Leader STRUCTURAL TECHNOLOGIES

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

GYPSUM AREA SEPARATION FIREWALLS GA

Comment Form on Proposed Gut Rehabilitation Alternatives

Waterproofing membranes are a critical component

CertainTeed. Shaftliner For A rea Separation Firewalls

R E S I D E N T I A L H O U S I N G

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

Foundation Code compliance and Best Practices By Michael Coello

Residential Foundations and Basements

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

LAYING BLOCK AND BRICK

The minimum reinforcement for the stem wall is the placement of:

DELTA Premium Moisture Management Systems for Foundations.

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

What you need to know about concrete block basement construction.

Note: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change.

Retrofitting an Insulated Cold Roof

COMMONLY USED RESIDENTIAL BUILDING CODES

Basement Moisture Problems

Asphalt Shingle Application Requirements

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

CertainTeed SOLAR. Solar From A Proven Source

Foundation. Foundation

Tools Required. Recommended Adhesives Vinyl Bonding: - Christy s White Hot Vinyl Cement

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

OSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION

Pre-Drywall Inspection Report

Installation & Technical Guide

PANEL CONCEPTS LLLP.

Product Support Catalog. Product Literature and Promotional Support Materials

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Wet Basements. While listening to a home-improvement call-in. Foolproof Cure for

Wall and Ceiling Products Moisture and Corrosion Proof Panels

WET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.

GreenGuard Housewrap Installation Guide

Shingle Installation Guide

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Self-Home Inspection Checklist

Renovating Your Basement

HOW TO INSULATE A CRAWLSPACE

BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR MARCH 2003 REVISED JUNE 13, 2012

SANITARY SEWER SPECIFICATIONS

How To Use A Hydraway System

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Chapter 3 Pre-Installation, Foundations and Piers

COMMERCIAL BUILDING APPLICATIONS

C e r t a i nte e d. D e s i g n e r S h i n g l e s. Shown in: Roof - Fieldstone; Siding - Cedar Impressions Double 7" Perfection Shingles Seagrass

How To Repair A Boat Landing Deck With A Boat Bed

52 Ways To Save. 3. Ask for feedback. Ask about the pros and cons of different elements of your design and how each will affect your budget.

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

HOW TO INSULATE CATHEDRAL CEILINGS

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

PANELIZED HOME INSTALLATION GUIDELINE

AMERICAN GOTHIC PLAYHOUSE

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Quality Building Products for over 50 Years

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Mark Cramer Inspection Services, Inc.

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

Water Damage & Repair

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

Chapter 2: Foundations

EZFold Trade Show Flat Panel TV Stand for 37-70" Flat Panel Displays

Waterproofing and interior insulation for basements takes new twist in technology.

Electrical Wiring Technical Bulletin

How To Repair A House

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

POST AND FRAME STRUCTURES (Pole Barns)

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

Lighthouse Engineering, L.L.C.

Basement & Foundation Damage

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope

1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.

MUNICODE SERVICES LTD.

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

about your house Before You Start Renovating Your Basement Moisture Problems Figure 1 Moisture problems to solve

Mobile Home Pre-Inspection Checklist

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Scepter PVC Molded Junction Boxes

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

Excerpts from the Canadian National Building Code (NBC)

VILLAS OF TRADITIONS AT GREY OAKS

Special Use Commercial Properties

Transcription:

C ertainteed Concrete Forming and Drainage...It's About Time...Your Time

Features and Benefits Builders and contractors alike now have a revolutionary way to design a superior foundation system into their homes Features Builder Benefits Features Contractor Benefits Ideally located drainage system, parallel to footing, below foundation wall Relieves hydrostatic pressure on walls and slabs, reducing risk of cracking Stay-in-place lineal footing form system Eliminates wood or metal form cost, and form removal, cleaning, and transportation costs Drainage system cannot sag or crimp Greater water intake capacity than traditional drain pipe Level installation Reduces risk of blockage or uneven drainage Ensures rapid collection of ground water. Minimizes possibility of basement water infiltration. Uniform drainage of foundation; easier to set wallforms and masonry block Less elapsed time between footing pour and wall construction Immediate drainage capability Simple adaptation with a round pipe T and vertical PVC pipe stack provides radon reduction Increases productivity Can minimize down time in inclement weather Eliminates material and labor costs for a separate radon reduction system; sub-slab perimeter system already in place Smooth interior surface and less chance of build-up and clogging Allows for free flow of water Eliminates need for conventional corrugated poly drain tile Reduces material and labor associated with drain tile installation Drainage is provided for both the inside and outside of foundation footing Better protection against basement water infiltration. Reduces risk of cracking and leaking. Complete line of lineals, couplings, 90 and 45 corners, vertical L s, outlets, and accessory items Can accommodate virtually any foundation layout Strong, rigid PVC construction; Minimizes possibility of system greater stiffness failure due to a collapsed or crushed drainage system Conforms with EPA s "Model Acceptance by local code Standards & Techniques for officials and inspectors Radon Control in New Residential Buil dings. Form-A-Drain is the subject of ICC-ES Legacy Report Number 95-37.01 and CCMC 13492-R. No oiling of forms required Lightweight lineals: 4" = 7 lbs, 6" = 10 lbs, 8" = 13 lbs, 10" = 14 lbs Simple leveling method Job site assembly without the use of solvent cement or mechanical fasteners Easy to cut with hand or power saw Spacer straps available in pre-determined width dimensions Reduced oil cost and elimination of oil handling and disposal Reduced job site labor, lower risk of injury, reduced fatigue Labor savings during form set-up/installation Similar set-up time to wood, may reduce overall form set-up time No additional or special tools required for cutting; fast installation Improved set-up time by reducing time used for measuring, possible rebar chair

Money Time is Every contractor knows that time is money. The more jobs You can finish in a day, A week, or a month, the more revenue you generate. that s why the Form-A-Drain foundation footing system is such a great idea. It saves you time in several different ways, allowing you to move from one job to the next more quickly. Form-A-Drain is used in place of wood to form the footing, then remains in place after the concrete is poured. You don t have to go back to strip and clean your old forms, load them on the truck, and haul them to the next job. Form-A-Drain is both the footing form and the foundation drainage system, so your crew accomplishes these two jobs at the same time. For many contractors, the time saved using Form-A-Drain allows them to complete more jobs, resulting in additional profits. Form-A-Drain is easily adapted to be part of a radon gas venting system, so your crew can carry out this job efficiently in areas where code or local practice requires it. Time, labor and material savings add up in your favor when you use Form-A-Drain. And your customers will appreciate the fact that you ve incorporated the best available foundation drainage system, a quality CertainTeed product, into their homes. 4", 6", 8", 10" lineals 8" and 10" sizes are suitable for light commercial and large residential construction. Lineal sections, couplings, and corners ensure precise form set-up. A 3-in-1 solution from CertainTeed A well-built home begins with the foundation. That s why CertainTeed developed Form-A-Drain, a patented, permanently installed system that handles three vital foundation functions. Form-A-Drain: forms the footing, drains the foundation and provides a means for radon reduction.

The 3-in-1 2. Integrated drainage Sol During the concrete pour, grade stakes hold the Form-A-Drain system at the proper elevation. Thereafter, Form-A-Drain remains permanently in place. 1. Precise footing forms, permanently in place Form-A-Drain lineal sections, couplings and corners are designed to ensure a precise form set-up. And because Form-A-Drain is a manufactured product, there are little or no variations from piece to piece allowing for a very flat and level footing. Optional spacer straps can be used to hold the lineals in place at specified widths for consistent dimensions ; rebar stakes can also be used if desired to pin the 90 corners and couplings. Proper staking with forming pins, wood stakes or CertainTeed grade stakes holds the Form-A-Drain system to the proper height as well as helping to keep the forms in place. One of the many unique features of the Form-A-Drain system is that it stays permanently in place. There s no need to return to the job site to strip, clean and load wood forms making Form-A-Drain a very cost-effective way for contractors to complete the forming and draining of the foundation footing. With Form-A-Drain, even as you re setting up the footing forms, you re creating the drainage system two jobs accomplished at one time, with no need to purchase and install separate drain pipe. Form-A-Drain is an outstanding alternative to perforated pipe when it comes to drainage performance. It has a greater water intake capacity than traditional drain pipe, and its strong, rigid construction assures a quality installation. Each lineal section is manufactured with one slotted wall, which allows the collection of water at the footing. The collected water then flows through the hollow core of the Form-A-Drain system to the drainage outlet, where it is safely discharged away from the home. With Form-A-Drain, the foundation system is located where it should be at the top of and on both sides of the footing. This is the optimum area of a home s foundation where water can be effectively collected and ultimately discharged away from valuable living space. Another Form-A-Drain benefit is that it provides drainage on both the exterior and interior sides of the foundation. Crossovers can be used to connect the inner and outer lineal sections, allowing drainage from both sides of the footing to be discharged to either a sump pit or away from the foundation, toward the back of the building lot and safely away from the home. A third option is to position the outlets so that water in the outside lineals drains away from the foundation and water in the inside lineals drains to a sump pit. FORMS FOOTINGS Drains Foundations

ution 3. Radon reduction The third element of Form-A-Drain s 3-in-1 advantage is its ability to capture radon from under the basement slab and around the interior perimeter of the foundation footing for venting. Again, because Form-A-Drain stays in place after the footing is poured, it s in perfect position to perform as part of a radon reduction system. Simply add a single outlet to one of the inner Form-A-Drain lineals and connect it to dedicated vent pipe, as described in the Form-A-Drain installation guide (40-95-04). Form-A-Drain forms a complete loop around the inside perimeter of the footing, serving as a radon collection point in conformance with the Environmental Protection Agency s Model Standards & Techniques for Radon Control in New Residential Buildings. Why Contractors love Form-A-Drain: A Better Alternative to Boards and Round Pipe Form-A-Drain allows us to dig the hole, pour the footing and have the complete tile and gravel job done all in one day. James Bartels, M.B.I. Construction, Inc., Effingham, IL The drain and radon systems are excellent. William Alaimo, Confor, Inc., Peckville, PA With simple adaptations, Form-A-Drain can perform as part of a radon reduction system. As a custom builder, we re always looking for ways to save time on the job and improve quality for our customers. We began using Form-A-Drain on our homes several years ago because it s easy to install and makes a nice looking job. It s a quality product that s good for our bottom line and our reputation. Joe Nadu, Lancaster Home Builders, Lancaster, PA Quality is far superior to conven tional methods. Erwin Sweet, Perma-Structo, Inc., Sturtevant, WI We switched from flexible perforated pipe to Form-A-Drain. It saves time, labor costs and headaches. It s faster and easier to install on a level grade, virtually eliminating any water problems that might occur. John Azzari, Alessio Azzari Concrete, Inc., Mickleton, NJ SUPPORTS RADON VENTING

piecing together a custom Solution Lineals are 12 feet long, are available in profile heights of 4", 6", 8" (2 1 /4" width) and 10" (1 1 /2" width), and weigh between 7 and 14 pounds depending on profile. Lightweight Form-A-Drain lineals are easy to transport and work with, and can be cut to desired lengths with a hand or power saw. Available fittings include couplings, 45 and 90 corners, single and double drainage outlets, outlet adapters, and vertical 90 L adapters. Spacer straps come in various widths to ensure proper footing dimensions, and grade stakes are either 18" or 30" in length. All lineals, fittings and accessories are made to exact CertainTeed product specifications. Fittings are designed for easy assembly, with no need for mechanical or solvent fastening. Quality is just the beginning Since 1904, CertainTeed has been manufacturing high quality, innovative building products, including roofing, insulation, vinyl and fiber cement siding, vinyl fence, railing and deck and pipe. Our name is derived from the slogan Quality made certain, satisfaction guaranteed, and reflects an unwavering commitment to the building professionals who rely on us. This commitment, and our many years of experience in product design, were applied to the challenge of creating a better foundation footing and drainage system and Form-A-Drain is the result. Form-a-Drain lineals are made from 100% recycled PVC for conformance with Green building construction practices. CertainTeed respects the environment through the responsible development of sustainable building products and systems. SYSTEM COMPONENTS AVAILABLE SizeS Part # Lineals 4" x 12' LN124 6" x 12' LN126 8" x 12' LN128 10" x 12' LN1210 Fittings Coupling 4" XCPL4 (extruded) 6" XCPL6 8" XCPL8 10" XCPL10 Coupling with Hole 6" COUP6 (molded) 8" COUP8 10" COUP10 90 Corner 4" CN904 (molded) 6" CN906 8" CN908 10" CN9010 45 Corner 4" CN454 6" CN456 8" CN458 10" CN4510 4" Outlet 4" OUT44 6" OUT46 8" OUT48 10" OUT410 4" Double Outlet 6" DOF46 8" DOF48 10" DOF410 Vertical 90 L 4" VL904 6" VL906 8" VL908 10" VL9010 Accessories Grade Stake 18" GS018 30" GS030 Spacer Strap width 4"d x 16"w SS416 For 4", 6", 8" 4" 4"d x 20"w SS420 4"d x 24"w SS424 Spacer Strap width 8"d x 20"w SS820 For 10" 8"d x 24"w SS824 Snap-in Adapter 8" 4" fits all AD004 The properties, dimensions and weights of lineals and fittings listed here are subject to normal manufacturing tolerances. This information is supplied for user reference only and is subject to change without notice. NEW Ask your distributor for the new CertaForm leave-in-place form a perfect complement to Form-A-Drain in one-sided drainage applications. ASK ABOUT ALL OF OUR OTHER CERTAINTEED PRODUCTS AND SYSTEMS: ROOFING SIDING TRIM WINDOWS DECKING RAILING FENCE INSULATION GYPSUM CEILINGS FOUNDATIONS PIPE www.certainteed.com http://blog.certainteed.com CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 Professional: 800-233-8990 Consumer: 800-782-8777 08/12 CertainTeed Corporation Code No. 40-95-07J U.S. Patent # 5,474,400.Canadian Patent # 2,135,168.