Cerampak is weldable, flexible - can be bent on a radius 2 times its diameter - and moisture free when fabricated.



Similar documents
MGO Insulated Thermocouples Index

Thermocouples & Thermoresistances

Industrial Thermocouples

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

CARTRIDGE HEATERS TECNOLOGIC UK. Tel: l Complete temperature control solutions

Index 7.1. Page R2 12/99

ASME Packaged Indirect Fired Water Heater

Light Duty Commercial Electric Water Heater

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

Screw Plug Immersion Heaters

Check Valves & Actuated Valves

Heating Cable. Construction

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

SIMPLAIR PIPING TOOL

THERMOCOUPLES GENERAL DESIGN AND SELECTION THERMOCOUPLE STANDARD

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

ANTENNA PARTS CATALOG

Thermocouple Wire & Cable

HYDRAULIC AND LUBE OIL HEATERS HYDRAULIC AND LUBE OIL HEATERS. HL Series. Warren Electric Corporation

UNITHERM UNITHERM 2256/2266 SELF-REGULATING ELECTRIC TRACE TUBING

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Application Guide. Compensators Hose Assemblies Expansion Joints FLEX-WELD INCORPORATED FLEX-WELD.COM. Manufactured By:

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

Quick Connect. RTDs, Cordsets and Transmitter with M12 Connections

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

AUTOMATIC CHANGEOVER MANIFOLD Series 915

Cables. Accessories. For Force, Torque and Strain Sensors

SECTION PIPE HANGERS AND SUPPORTS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Steam System Best Practices Condensate System Piping

Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems

WD600 STEAM TRAPS. Thermodynamic Steam Trap

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM

Micro Motion Model D and DL Coriolis Flow and Density Meters

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

WELCOME TO MAGNATROL

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

SOLDERING TERMINALS TRAINING CERTIFICATION TEST (DVD-18C)

INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

TECHNO Multi-Purpose Check Valves for Industry

For Multi-Parameter Meters see mvx

SITRANS F flowmeters SITRANS F M

18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30

Typical Aluminum GFM Mass Flow Meter

HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE

James M. Pleasants Company

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Copper Meter Resetters

Commercial Electric Water Heater

Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

with installation dynafact boost GAUGE this manual is for use with systems

PUSH-PULL CABLES CONTROL SYSTEMS

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

INHALT. page. < Thermo 8-plug and 16-plug connector T < Thermo 8-plug plastic connector T

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

POLARIS INSUL-TAP CONNECTORS FOR TWO WIRES & IN-LINE SPLICERS/REDUCERS

POWERS Controls No. 4 Pneumatic Damper Actuator

A full spectrum of custom cables

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Instruction Manual. Cable Splicing. Models , HDF1, HDF SS1

Submersion/Insertion Toroidal Sensor

Many Products...One Source

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

CHEXTER TM FITS YOUR APPLICATION, PROFITABLY

ELECTRICAL SAFETY Information Bulletin

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

THERMOCOUPLE GENERAL INFORMATION

Schedule 40 & Schedule 80 Rigid PVC Piping Systems Scroll Down for Dimensions, Components, Hangars & Supports, Fabrication Techniques

High Pressure Equipment High Pressure Valves, Fittings and Tubing

Waekon Gold. Test Lead Master Kit. Tight Spot Test Lead Kit. Micro Mate Terminal Adapter Set. Magnetic Test Lead Ground Lug

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE

SELECTION, APPLICATION AND MAINTENANCE

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

DRESSER TM PIPELINE SOLUTIONS

High Pressure Equipment Pressure Vessels and Reactors Index

Scraper Passage Indicator. Electrical Indicator. Features

2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com

O to 15,000 psi and media temperature between -130 F and 752 F. Examples of Typical Diaphragm Seal Applications

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES

DESIGN STANDARDS SECTION

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

Application of thermocouples

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

Toroidal Conductivity Sensor

STANDARD SPECIFICATIONS SECTION METAL FABRICATIONS

Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.

Transcription:

MGO Thermocouples Thermo Sensors MGO thermocouple insulation materials feature Cerampak. These MGO thermocouples are recommended where the thermocouple is immersed in liquids, high moisture, corrosive gases, or high pressures. Cerampak is a densely compacted ceramic which is very versatile. This weldable and flexible material can withstand temperatures from cryogenic to 2300ºF as well as pressures from vacuum to 60,000 psi. A wide variety of design, sheath material and diameter selections are available to suit application conditions. A variety of heads, connectors or flexible leads can be specified for the termination. Please refer to our order guide to assist in determining your needs. We can also provide technical design assistance and application suggestions. Give us a call. Introduction to MGO Thermocouples Cerampak is a densely compacted ceramic insulated metal sheathed thermocouple material manufactured to exacting standards to assure unquestioned quality. These standards coupled with the latest fabrication techniques and equipment assure the customer of thermocouples of the highest quality. The versatility of this material is virtually unlimited - temperatures from cryogenic to 2300 F - pressures from vacuum to 60,000 psi. The sheath wall thickness, diameter and installation directly determines the time response of the sensor. Proper selection of sheath material to withstand the temperature and other process governmental perimeters is imperative to provide maximum life of the sensor. Cerampak is weldable, flexible - can be bent on a radius 2 times its diameter - and moisture free when fabricated. Selection of various order code options from the tables on this and the following pages enables the customer to custom build a Cerampak assembly to satisfy his individual requirement. Personnel to provide technical design assistance and application suggestions are available. *Other materials for higher temperatures in special atmospheres are available. www.thermosensors.com Page 1

Cerampak Selection/Hot Junction Selections/Length of Sensor Table 1 Sheath Diameter Order Code ANSI Calibration Order Code Sheath Material Single Dual Order Code 020" 025" 032" 040" 3/32" 1/16" 1/8" 3/16" 1/4" 5/16" 3/8" 1/2" 020 025 032 040 093 1 2 3 4 5 6 8 Chromel/Constantan Iron/ Constantan Chromel/Alumel Nicrosil/Nisil Copper/Constantan Plat 10% RH/Plat Plat 13% RH/Plat Plat 30% RH/PT 6% RH E J K N T S R B 2E 2J 2K 2N 2T 2S 2R 2B 304 St. St. 310 St. St. 316 St. St. 410 St. St. 446 St. St. Inconel 600 Inconel 601 Incoloy 800 Tantalum Platinum Monel Hastelloy "X" Hastelloy "C" Hastelloy "B" Nickel H2300 34 30 36 40 46 60 61 80 99 97 96 95 94 93 92 23 Notes: 1. For Premium Grade (Special Limits of Error) material; add "PG" to the calibration code. Example: 4KPG60 Table 2 Hot Junctions Grounded Order Code G Exposed E Ungrounded U Ungrounded and Isolated (Dual - 4 Wire T/C only) UI Welding Pad* Horizontal Grounded P www.thermosensors.com Page 2

Welding Pad* Horizontal Ungrounded UP Welding Pad* Ungrounded and isolated (Dual T/C only) UIP Welding Pad* Vertical Grounded VP Welding Pad* Vertical Ungrounded VU Welding Pad* Vertical Ungrounded and Isolated (Dual T/C only) UVI * 1" x 1" x 1/8" pad furnished. Stainless steel hold-down clips to secure the pad thermocouple horizontally to the process tube are available. (Fits 3/16" & 1/4" O.D. Sensor). Specify Part Number 101-4. Table 3 Sensor Length Refer to your selection of a Cold Junction Termination from Table 4 and specify required Length ("L"). Order Code: Specify "L" in Inches and Decimal Increments www.thermosensors.com Page 3

Table 4 Connectors / Fittings Order Code Connectors Order Code B3* M *For longer lengths; replace "3" with desired length. SB Standard male plug. HM F Standard female jack. HF 1/2" npt x 1/2" npt SS Double threaded bushing brazed to the sheath. DM FS4 Dual male plug. HDM DF 1/2" NPT SS threaded bushing brazed to sheath. SBS Dual female jack. HDF TM 1/2" NPT x 1/2" NPT SS Double threaded bushing springloaded to sheath Miniature male plug. (for sheath diameters 1/8" maximum) HTM TF Miniature female jack. (for sheath diameter 1/8" maximum) HTF www.thermosensors.com Page 4

Table 4 continued Extended Leads / Lead Terminations Fiberglass Insulation Order Code TG(X)* 20 AWG Wire Extension** Polyvinyl Insulation Teflon Insulation TP(X)* TT(X)* Kapton Insulation TK(X)* Polyvinyl Insulation, Twisted, Alum-Mylar Sheilded w/ Drainwire Grounded to the sheath. TPZD(X)* Fiberglass Insulation TGS(X)* 20 AWG Wire Extension Inside Stainless Steel Overbraid** Polyvinyl Insulation Teflon Insulation TPS(X)* TTS(X)* Kapton Insulation TKS(X)* Fiberglass Insulation TGA(X)* 20 AWG Wire Extension inside stainless steel flexible tubing armor.** Polyvinyl Insulation Teflon Insulation TPA(X)* TTA(X)* Kapton Insulation TKA(X)* Fiberglass Insulation TGP(X)* 20 AWG Wire Extension inside polyvinyl covered stainless steel flexible tubing armor.** Polyvinyl Insulation Teflon Insulation TPP(X)* TTP(X)* Kapton Insulation TKP(X)* * Replace (X) with desired length in inches. ** Standard conductors are solid. For stranded conductors - Specify by placing "F" in the order code before length. Example: TGSF36. (Not available for "TPZD" option). *** "DRIP loop" style T/C's are available in armored lead options. Choose head option in the hardware section and add head order code as a suffix to the complete part number. www.thermosensors.com Page 5

Table 4 continued Terminal Heads Figure 1 T/C Assembly Without Process Fitting Figure 2 T/C Assembly w/ 1/2" NPT Process Fitting Figure 3 T/C Assembly w/ 1/2" NPT Spring Loaded Fitting www.thermosensors.com Page 6

Table 4 continued www.thermosensors.com Page 7

Table 5 Stainless Steel Adjustable Mounting Fittings Compression Type (One time adjustable) Compression Type (Readjustable) Metal Collets Teflon Collets Mounting NPT Order Code Mounting NPT Order Code 1/8" NPT 1/4" NPT 3/8" NPT 1/2" NPT *3/4" NPT 1AS 2AS 3AS 4AS 6AS 1/8" NPT 1/4" NPT 3/8" NPT 1/2" NPT *3/4" NPT 1RS 2RS 3RS 4RS 6RS *3/4" npt compression type fittings are supplied as smaller npt fittings bushed to 3/4" npt. Note: Fittings furnished may not have the same physical appearance as illustrated above, but will be functionally equal. Extended Leads / Lead Terminations Spade lugs for No. 8 screw. Order Code L Male plug. M HM Female jack. F HF 1/2" npt "BX" connector (not watertight). BX Water tight connector for condulet installation. (Neopren sealant). 1/2" npt W1 3/4" npt W3 www.thermosensors.com Page 8

Miscellaneous Options A) Bends: To specify a 90 bend along the "L" length; Add "- 90 B (Length from Tip) Example: 90 B8 for a 90 bend 8" from tip. B) High Temp Potting: To specify a higher temperature than the 300 F. rated material in the transition, Add the following suffix: For 400 F Epoxy: -EII For 1000 F Cement: -HTC C) Adjustable spring "FP-275" Order Code FP 275 D) Adjustable spring loaded fitting Order Code SSL E) Adjustable spring-loaded fitting Order Code FP 240 www.thermosensors.com Page 9