THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features



Similar documents
THE WALL-MOUNT TM HEAT PUMPS - (60HZ)

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

WALL MOUNTED PACKAGED AIR CONDITIONER INSTALLATION INSTRUCTIONS. Models: WA182, WA242. Bard Manufacturing Company, Inc.

WALL MOUNTED PACKAGED AIR CONDITIONER INSTALLATION INSTRUCTIONS. Models: WA301, WA361. Bard Manufacturing Company Bryan, Ohio 43506

WALL MOUNTED PACKAGED WA372. Bard Manufacturing Company Bryan, Ohio Manual No.: Supersedes: File: Volume III, Tab 16 Date:

THE WALL-MOUNT 6-TON AIR CONDITIONERS

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W70A1 W70L1. Models: Contents. General Notes. Important. Description

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel.

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

SECTION AIR CONDITIONING UNIT

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Housing

catalog Single Package Vertical Air Conditioners and Heat Pumps

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION HEAT PUMPS

MAC-120HE-01 Air-Cooled Chiller

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

NSN

GCS16 GCS20 WARNING CAUTION

Bring the fresh in. Dedicated Outside Air Systems

york air-conditioning products Residential & VRF News 2015

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

ECOCIAT. Domestic hot water heat recovery unit

FOXAIR 60/50 ALL MODELS

GCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Split System Cooling Product Data

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Single Package Vertical Air Conditioners. Vert-I-Pak

LOBOY 16 AIR CONDITIONERS

Commercial Gas Furnace Upflow

ARMSTRONG AIR HEAT PUMPS

Operation and Installation Manual. Max Series

Air Conditioning System

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

USER S MANUAL HSC-24A

Glossary of Heating, Ventilation and Air Conditioning Terms

Portable Air Conditioner

Air-Cooled Condensers

Split System Heat Pump Product Data

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Local Dealer:

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Product Data. Split System Cooling F-EN. March 2015

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION BLOWER COIL UNITS

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Dehumidification Frequently Asked Questions

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Split System Cooling Product Data

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

air conditioners how to choose a cooling system

ComPac I and ComPac II Air Conditioner Product Manual

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Cooling Capacity CFM in. w.c. (125 Pa)

CE6500 Energy Recovery Ventilator

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Cooling/Heat Pump Convertible Air Handlers

PACKAGED TERMINAL AIR CONDITIONERS

PACKAGE AIR CONDITIONERS REPLACEMENT PARTS MANUAL

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

SPLIT-SYSTEM CONDENSING UNITS SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION FEATURES

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE HEAT PUMP UNITS BQ 036, 048 & XTG-C-0109

E2 Series Electric Furnaces

Mechanical Rooftop Custom Capabilities


AIR-COOLED CONDENSERS Technical Guide

SECTION MORTUARY REFRIGERATORS

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Air Conditioning Sign-Off Sheet

Installation Instructions

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL. Rev. F 2015 Pentair Equipment Protection P/N

Installation Manual CLIFC Fan & Coil Variable Speed

TECHNICAL MANUAL GDS8 & GHS8

Transcription:

THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating and cooling system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. The One Ton is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities. Factory or field installed accessories are available to meet specific job requirements. Engineered Features Aluminum Finned Copper Coils Grooved tubing (evaporator coil only) and enhanced louvered fin for maximum heat transfer and energy efficiency. Quiet Twin Blowers: Designed to accept full ducted system or for non-ducted free blow installations. High Efficiency Rotary Compressor R-A Refrigerant: Designed with R-A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and 20 EPA requirements. Liquid Line Filter Drier: Standard on all units. Protects system against moisture. Galvanized 20 Gauge Zinc Coated Steel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand 00 hours of salt spray tests per ASTM B7-03. Electrical Components: Are easily accessible for routine inspection and maintenance through a right side, service panel opening. One Inch, Disposable Air Filter: Easily removed for replacement from the outside. Optional two-inch pleated filter, factory or field installed. Optional Product Features Alarm Relay: Dry contacts for remote alarm on high or low pressure lockouts. Low Ambient Control: Permits operation down to 0 F outdoor ambient. Can be factory or field installed. Top Rain Flashing: Standard feature on all models. Slope Top: Standard feature for water run-off. Compressor Control Module: Standard on all units. Built-in off-delay timer adjustable from 30 seconds to 5- minutes. 2-minute on-delay if power interrupt. 20-second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. High & Low Pressure Switches are Auto-Reset: Standard on all units. Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Barometric Fresh Air Damper: Allows up to 0 CFM of fresh air. Automatic Condensate Disposal System: Eliminates the need to provide a separate condensate drain. The drain valve closes at temperatures above 0 and opens when the temperature drops below 0. Built-in slinger ring fan blade. Full Length Mounting Flanges: Built into cabinet for improved appearance and easy installation. Fully Modulating Economizer: Can be factory or field installed. Commercial Room Ventilator: Can be factory or field installed. Complies with efficiency requirements of ANSI/ASHRAE/IESNA 90.-20. Certified to ANSI/ARI Standard 390-2003 for SPVU (Single Package Vertical Units). Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI/UL 995/CSA 22.2 No. 236-05, Fourth Edition. Commercial Product - Not intended for Residential application. Page of 8

Capacity and Efficiency Ratings Models Volts Phase Heat Strip Cooling Cap. BTUH EER 2 W2A2-A0Z 230/208 NONE,800 W2A2-A03 230/208 3.6,800 W2A2-A05 230/208 5.0,800 W2A-K00 5 NONE,800 W2A-K02 5 2.2,800 Capacity is certified in accordance with ANSI/ARI Standard 390-2003. 2 EER = Energy Efficiency Ratio and is certified in accordance with ANSI/ARI Standard 390-2003. All ratings based on fresh air intake being 0% closed (no outside air introduction). Electrical Specifications Models W2A2-A0Z A03 A05 W2A-K00 K02 Rated Volts and Phase Operating Voltage Range 230/208-97-253 5- -26 No. Field Power Ckts. Minimum Circuit3 Ampacity 9 20 28 20 29 Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. 2 Based on 75 C copper wire. All wiring must conform to NEC and all local codes. 3 These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical Code (latest revision), article 3 for power conductor sizing. Internal circuit breakers are standard on W2A2-A models. Maximum External Fuse or Circuit Breaker 5 20 30 30 30 Field Power 2 Wire Size 2 Ground 2 Wire Size 2 CAUTION! When more than one field power conductor circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of table 3 regarding Ampacity Adjustment Factors when more than 3 conductors are in a raceway. Specifications Compressor Outdoor Fan Motor Indoor Blower Motor CFM/ESP Rated-WET Coil 00/. 00/. Shipping Weigh 60 lbs 60 lbs Electrical Rating - 60 HZ 30/208-5- Models RLA LRA HP-RPM-SP FLA HP-RPM-SP F LA ( ) t W2A2-A 2 5.5/. 8 32. 5 /-75-. 70 /8-650-2. 85 0. W2A-K. 6 63. 0 /-75-.0 /8-650-2.60 0. Electric Heat Table Models W2A2-A 20V- 208V- AMPS BTUH AMPS BTUH 5. 2,285 3. 0,230 20. 7,065 8. 2,800 W2A-K 20V- AMPS BTU H 3.0 0 9 - - 5.0 8 - - 2.0 - - - - 8. 3 7,5 Indoor Blower Performance - CFM at 230 E.S.P. IN H 2 High Speed Dry/Wet Coil. 0 30/500. 85/60. 2 0/25. 3 90/375. 25/300 Low Speed Dry/Wet Coil 65/2 5/0 365/35 35/30 300/28 5 5 0 0 3 0 3 5 Cooling Application Data - Outdoor Temperature F M odels D.B./W.B. 2 Cooling Capacity 75 80 85 90 95 0 5 5 20 75/ 62 Total Cooling Sensible Cooling,00 9,0,000 8,900,500 8,800,000 8,600 9,00 8,00 9,000 8,0 8,300 7,800 7,800 7,500 7,0 7,0 6,00 6,00 W2A 80/ Total Cooling 2,0,900,600,300,800,00 9,800 9,200 8,500 7,700 67 Sensible Cooling 8,800 8,700 8,700 8,600 8,00 8,200 8,000 7,700 7,300 6,900 85/ 72 Total Cooling Sensible Cooling,500 9,0,000 8,900 3,00 8,800 2,800 8,600 2,000 8,300,00 8,000,600 7,700 9,800 7,300 9,000 6,800 8,000 6,300 Below 55 F, unit requires a factory or field installed low ambient control. CAPACITY MULTIPLIER FACTORS 2 Return air temp. F. % of Rated Airflow - Rated + Total BTUH 0.975. 0.02 Sensible BTUH 0.950. 0.05 Page 2 of 8

Ventilation System Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a barometric fresh air damper as the standard ventilation package. All ventilation packages can be built-in at the factory or field-installed at a later date. BAROMETRIC FRESH AIR DAMPER BFAD- STANDARD The barometric fresh air damper is a standard feature on all models. It is installed on the inside of the service door and allows outside ventilation air, up to 25% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The damper opens during blower operation and closes when the blower is off. Adjustable blade stops allow different amounts of outside air to be introduced into the building and can be easily locked closed if required. Barometric Fresh Air Damper NOTE: The above vent systems are intake only without built-in exhaust capability. Building will likely require separate field installed barometric relief or mechanical exhaust elsewhere within the conditioned space. Balancing dampers in the return air grille may be required to achieve specified amount of outdoor air intake. BLANK OFF PLATE BOP-A OPTIONAL A blank off plate is installed on the inside of the service door. It covers the air inlet openings, which restricts any outside air from entering the unit. The blank off plate should be utilized in applications where outside air is not required to be mixed with the conditioned air. COMMERCIAL ROOM VENTILATOR CRVS- OPTIONAL The built-in commercial room ventilator is internally mounted behind the service door and allows outside ventilation air, up to 50% of the total airflow rating of the unit, to be introduced through the air inlet openings. Commercial Room Ventilator The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field controlled based on room occupancy. Two versions available (except on.5 and 2-Ton models). The CRV and CRVS are power open - spring return on power loss, and CRVP is power open and power close. Complies with ANSI/ASHRAE Standard 62. Ventilation for Acceptable Indoor Air Quality. ECONOMIZER JIFM- OPTIONAL The built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. Economizer Standard Features: Fully modulating Honeywell Direct Drive Hi-Torque Actuator No linkage required Simple single blade design Positive shut-off with non-stick gaskets Electronic Enthalpy sensor Honeywell JADE electronic economizer module with precision settings and diagnostics Moisture Eliminator and Prefilter permanent, washable, aluminum construction Page 3 of 8

CRVS- TOTAL AND VENTILATION AIRFLOW 600 500 Airflow (cfm) 00 300 200 Total Air 0.0 ESP Total Air 0. ESP Total Air 0.2 ESP Total Air 0.3 ESP Vent Air 0.0 ESP Vent Air 0. ESP Vent Air 0.2 ESP Vent Air 0.3 ESP 0 0 A B C D Vent Position Brown/white wire must be switched from terminal X to terminal D on damper motor to attain D position. This will bypass potentiometer function and go to full open when energized. Page of 8

This Page Intentionally Left Blank Page 5 of 8

Page 6 of 8 This Page Intentionally Left Blank

Dimensions of Basic Unit for Architectural and Installation Requirements (Nominal) 7.00 7.00 3.37 Adjustable Return Flanges Optional Electrical Entrance Fixed Supply Air Opening Return Air Opening in Lower Position 7.00 5.00 5.00.95 5.03.05.05 Fixed Supply Air Opening Return Air Opening in Upper Position 7.00.50 20.3 Back View (Lower Return) Back View (Upper Return) 5. C L.25 TYP. 32.00 30.29 7.50 TYP. Rain Flashing (Shown Installed) Heater and Filter Access Panel.67 2.8 9.72 7.28 C L Control Panel Ventilation Air Low Voltage Entrance 26.69 6.06 2.79 Electrical Entrance 5.80 9.72 Condenser Air Exhaust (Blow through cond. coil) 8.69 9.88 C.93 L Condenser Air Entrance.38 SQ. C L C L Mounting 3.5 Holes Right Side View Front View MIS-2738 Page 7 of 8

Air Conditioning Model Nomenclature W 2 A 2 A 0Z X X X X X J MODEL NUMBER CAPACITY 2 - Ton AIR CONDITIONER REVISION VOLTS & PHASE A - 230/208-60- K - 5-60- 0Z - No 03-3.6 05-5.0 00 - No 02-2.2 COLOR OPTIONS X -Beige (Standard) - White - Buckeye Gray 5 - Desert Brown 8 - Dark Bronze CONTROL MODULES (See chart below) COIL OPTIONS X - Standard - Phenolic Coated Evaporator 2 - Phenolic Coated Condenser 3 - Phenolic Coated Evaporator and Condenser VENTILATION OPTIONS (See Vent Options Below.) FILTER OPTIONS X - -Inch Throwaway - x 20 x W - -Inch Washable - x 20 x P - 2-Inch Pleated - x 20 x 2 (MERV 8) OUTLET OPTIONS X - Front (Standard) Internal circuit breakers are standard on -A models. Clearances Required for Service Access and Adequate Condenser Inlet Airflow MODEL LEFT SIDE RIGHT SIDE W 2A 5" 20" NOTE: For side by side installation of two (2) W**A models there must be 20" between units. Minimum Clearances Required to Combustible Materials MODEL SUPPLY AIR DUCT FIRST THREE FEET CABINET W 2A 0 " 0" Ventilation Options Model W2A Description Factory Installed Field Installed Code No. Part No. Barometric Fresh Air Damper - Standard X BFAD- Blank-Off Plate B BOP-A Commercial Ventilator - Spring Return w/exhaust V CRVS- Economizer - Fully Modulating E JIFM- Low ambient control is required with economizer for low temperature compressor operation. Air Conditioning Control Modules HPC LPC 2 CCM 3 LAC ALR 5 Factory Installed Code All Models Except As Noted Field Installed Part X N/ A E CMA-28 J Factory Only = Standard equipment for these specified models. HPC High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3. 2 LPC Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3. 3 CCM Compressor control module has adjustable 30-second to 5-minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delayon-make will be 2 minutes plus % of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with retry) for high and/or low-pressure controls, and a 2-minute timed bypass for low-pressure control. LAC Low ambient control permits cooling operation down to 0 F. 5 ALR The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls. Bard Manufacturing Company, Inc. Bryan, Ohio 3506 www.bardhvac.com Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. S30 January, 20 Page 8 of 8