PowerChute Business Edition. Getting Started



Similar documents
To use PowerChute Web Device Manager, the Smart-UPS must connect to your network through one of the following types of servers or workstations:

Network Management Card Wizard--1. Introduction... 1 Using the Network Management Card Wizard... 5

Network Management Card. Installation and Quick Start Manual

Release Notes: PowerChute plus for Windows 95 and Windows 98

SOCET GXP V4.1 LICENSE MANAGER QUICK-START GUIDE

Using ESXi with PowerChute Business Edition

Title Page. Installation Guide. PowerChute plus Version for Windows 95

How To Install Safari Antivirus On A Dv8000 Dv Recorder On A Pc Or Macbook Or Ipad (For A Pc) On A Microsoft Dv8 (For Macbook) On An Ipad Or Ipa (

SAS 9.3 Foundation for Microsoft Windows

Symantec LiveUpdate Administrator. Getting Started Guide

AdminToys Suite. Installation & Setup Guide

Smart Control Center. User Guide. 350 East Plumeria Drive San Jose, CA USA. November v1.0

MIGRATING TO AVALANCHE 5.0 WITH MS SQL SERVER

Guide to Installing BBL Crystal MIND on Windows 7

Table of Contents. FleetSoft Installation Guide

Juris Installation / Upgrade Guide

VERSION NINE. Be A Better Auditor. You Have The Knowledge. We Have The Tools. INSTALLATION GUIDE

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

How To Upgrade Your Microsoft SQL Server for Accounting CS Version

Datacolor TOOLS. Datacolor TOOLS QCX. Datacolor TOOLS WORKSTATION

STATISTICA VERSION 10 STATISTICA ENTERPRISE SERVER INSTALLATION INSTRUCTIONS

Getting Started Guide

Client for Macintosh

Practice Fusion API Client Installation Guide for Windows

IBM WebSphere Application Server Version 7.0

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

MTS Remote Drive Service. Quick Start Guide

Wireless Remote Control of the TT24

Avaya Identity Engines Ignition Server Getting Started. Avaya Identity Engines Ignition Server Release 7.0

WINDOWS 64-BIT INSTALLATION NOTES ORACLE VIRTUALBOX Micro Planner X-Pert V3.5.1 Digital Download Edition

How to install and use the File Sharing Outlook Plugin

Using Remote Web Workplace Version 1.01

Virtual Owl. Guide for Windows. University Information Technology Services. Training, Outreach, Learning Technologies & Video Production

Snow Active Directory Discovery

DX8100 Series Symantec AntiVirus Corporate Edition Installation Instructions. Version

StarWind iscsi SAN Software: Using with Citrix XenServer

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

MDM Mass Configuration Tool User s Manual

Stellar Phoenix Exchange Server Backup

8x8 Virtual Office Telephony Interface for Salesforce

Installation Guide Command WorkStation 5.5 with Fiery Extended Applications 4.1

VERITAS Backup Exec TM 10.0 for Windows Servers

StarWind iscsi SAN Software: Installing StarWind on Windows Server 2008 R2 Server Core

Topaz Installation Sheet

Web based training for field technicians can be arranged by calling These Documents are required for a successful install:

BIGFI X. BigFix Remote Desktop for Windows. BigFix, Inc. Emeryville, CA. Last Modified: 9/13/07 Version BigFix, Inc.

Sophos Anti-Virus for NetApp Storage Systems startup guide

Installation Manual UC for Business Unified Messaging for Exchange 2010

ProSystem fx Document

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

Mobility Services Platform Software Installation Guide

Reconfiguring VMware vsphere Update Manager

Symantec Virtual Machine Management 7.1 User Guide

DriveLock Quick Start Guide

Registered Trademarks and Proprietary Names

Inmagic ODBC Driver 8.00 Installation and Upgrade Notes

Magaya Software Installation Guide

How schedule AccuTRConsole to run every hour

Patching the Windows 2000 Server Operating System on S8100 Media Servers, IP600 Communications Servers, & DEFNITY ONE Communications Systems

Dell Statistica Statistica Enterprise Installation Instructions

Global VPN Client Getting Started Guide

ESET REMOTE ADMINISTRATOR. Migration guide

Deployment of Keepit for Windows

Windows Server 2008 Hyper-V, Windows Server 2008 Server Core Installation Notes

Scan to SMB(PC) Set up Guide

Connecting to Remote Desktop Windows Users

MagiCAD License Server Utilities

4cast Client Specification and Installation

StarWind iscsi SAN: Configuring Global Deduplication May 2012

ESET NOD32 Antivirus 4 for Linux Desktop. Quick Start Guide

Installation Instruction STATISTICA Enterprise Small Business

TEKLYNX BACKTRACK VERSION4

PartnerConnect software. Installation guide

Deploying BitDefender Client Security and BitDefender Windows Server Solutions

1. Installing and configuring APC UPS Management

TOSHIBA GA Printing from Windows

Net Protector Admin Console

USER GUIDE. Snow Inventory Data Receiver Version 2.1 Release date Installation Configuration Document date

Installation and Connection Guide to the simulation environment GLOBAL VISION

Remote Monitoring Service - Setup Guide for InfraStruXure Central and StruxureWare 1 5

LRDC Computing Services

LifeCyclePlus Version 1

Reconfiguring VMware vsphere Update Manager

LT Auditor+ for Windows

Acronis Backup & Recovery 11

Introduction 1-1 Installing FAS 500 Asset Accounting the First Time 2-1 Installing FAS 500 Asset Accounting: Upgrading from a Prior Version 3-1

Getting Started with RES Automation Manager Agent for Linux

How To Install Outlook Addin On A 32 Bit Computer

Software Installation Requirements

Active Directory Software Deployment

Avigilon Control Center Gateway User Guide

VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide

Setting up VMware ESXi for 2X VirtualDesktopServer Manual

Acronis Backup & Recovery 11.5 Quick Start Guide

RUNNING TRACKER ON A TERMINAL SERVER

Installation Guide. . All right reserved. For more information about Specops Deploy and other Specops products, visit

Transcription:

PowerChute Business Edition Getting Started

Contents Getting Started Guide 1 PowerChute Business Edition Components 2 Installation Procedure 3 STEP 1: Install the PowerChute Business Edition Agent 3 STEP 2: Install the PowerChute Business Edition Server 4 STEP 3: Install the PowerChute Business Edition Console 5 STEP 4: Add UPS systems to your network 5 Silent Installation of a Windows Agent 5 Supported UPS Models 7 i

ii

Getting Started Guide The PowerChute Business Edition software suite consists of the three individual components identified in the illustration below: PowerChute Business Edition Agent PowerChute Business Edition Server PowerChute Business Edition Console For a description of these three applications, see PowerChute Business Edition Components; for an overview of the process you use to install these components, see Installation Procedure. 1

PowerChute Business Edition Components PowerChute Business Edition Agent Provides UPS status monitoring and, in the event of an extended power outage, system shutdown capabilities for your UPS-protected computers. This software must be installed on each computer that is directly attached to one of the UPS systems described in Supported UPS Models. PowerChute Business Edition Server Used to configure and monitor the PowerChute Business Edition Agents. The PowerChute Server gathers information from the PowerChute Agents and provides centralized event tracking, event notification and a single point of contact for the PowerChute Console. This software must be installed on one of your networked computers. PowerChute Business Edition Console Connects to the PowerChute Business Edition Server to provide the user interface for managing and configuring your UPS-protected systems. Install the PowerChute Console on any workstation, desktop, or laptop (running a supported operating system). Note: This help sometimes uses PowerChute to represent PowerChute Business Edition, for example, PowerChute Server instead of PowerChute Business Edition Server. 2

Installation Procedure The following list identifies the steps used to install PowerChute Business Edition, and provides links to more information about each step. STEP 1: Install the PowerChute Business Edition Agent STEP 2: Install the PowerChute Business Edition Server STEP 3: Install the PowerChute Business Edition Console STEP 4: Add UPS systems to your network You might find this section useful: Silent Installation of a Windows Agent Note: You should uninstall other APC PowerChute applications before trying to install PowerChute Business Edition. These applications include PowerChute plus, PowerChute Personal Edition, and PowerChute Network Shutdown. STEP 1: Install the PowerChute Business Edition Agent Install the PowerChute Agent on each of your UPS-protected computers. If you are downloading from the APC Web site, read the following points for the operating system that you are using: Windows 2000/ XP: download the setup executable file and double-click to start the installation. Linux - Download the rpm file. - Type rpm -i <rpm file name> to start the installation. Note: It might be necessary to use chmod to modify the file s permissions in order to make the file an executable prior to launching it. Solaris - Download pbe-agent-solaris_jvm.bin - Change the folder to the download folder. - Type./pbe-agent-solaris_jvm.bin to start the installation. Note: It might be necessary to use chmod to modify the file s permissions in order to make the file an executable prior to launching it. Novell NetWare - Create a folder pcbe on the NetWare server under SYS:\. - Download the installation files to this folder. - Type SYS:\pcbe\install to start the installation. For all installations, follow the steps below. 3

1. Click on the Install button for a standard installation, or click on the Upgrade button to install over an existing installation. 2. Accept the license agreement. 3. Choose the destination location for the PowerChute Agent files. You are not asked for a location during an upgrade type installation. The previous value is used by default. 4. Allow the install to automatically detect your attached UPS. You are not asked to select a UPS during an upgrade type installation. The previously used one is selected by default. Notes: If you click No when asked, Would you like to automatically search all communications ports for an APC UPS, a dialog box appears which you use to select the UPS type and Communication Port that the PowerChute Agent s host uses. If your UPS uses simple-signaling, then you have to detect it manually. If you are using a simple-signaling UPS with an accessory such as Interface Expander or Share-UPS, then select the basic port of the accessory. This will enable you to support both Timer Mode and Confirm Mode. 5. Enter a user name and password. This user name and password must be the same for all of your PowerChute Agents, but does not have to match any computer, administrator or domain accounts. You are not asked for a user name and password during an upgrade type installation. The previous values are used by default. STEP 2: Install the PowerChute Business Edition Server Install the PowerChute Server on one of your UPS-protected computers to provide centralized management of your PowerChute Business Edition Agents. It is recommended, but not required, that you install the PowerChute Server on one of your PowerChute Agent machines to maximize system availability. 1. Click on the Install button for a standard installation, or click on the Upgrade button to install over an existing installation. 2. Accept the license agreement. 3. Enter a user name and password. This user name and password must be the same as the information chosen in STEP 1: Install the PowerChute Business Edition Agent for your PowerChute Agents. You are not asked for a user name and password during an upgrade type installation. The previous values are used by default. 4. Enable Automatically check for product updates if you want the PowerChute Server to check periodically with APC for newer product versions. 5. Create your configuration profile, the global settings for all of your PowerChute Agents. 4

You are not asked to configure a profile during an upgrade type installation. The previous settings are used by default. 6. Select the PowerChute Agents to be managed by the newly installed PowerChute Server. Select the Agents on the left and click Add, or click New to manually enter an Agent address. When all changes are completed, click Apply to send your configuration profile to each of the selected Agents. Note: The Device List Configuration dialog box automatically discovers PowerChute Agents on the local network segment. With the Deluxe version of the software, you can discover Agents on other network segments by clicking on Configure Discovery. STEP 3: Install the PowerChute Business Edition Console Install the PowerChute Console on any of your desktop, workstation or laptop computers. The PowerChute Console may be installed on multiple computers if you typically manage your computers and/or software from different locations. Click on the Install button for a standard installation, or click on the Upgrade button to install over an existing installation. STEP 4: Add UPS systems to your network For each new UPS added to your network, do the following: 1. Repeat STEP 1: Install the PowerChute Business Edition Agent on the computer connected to the new UPS. 2. Select Configure Device List under the Tools menu in the PowerChute Business Edition Console to discover and add the new PowerChute Agent. Silent Installation of a Windows Agent This feature is only available with the Deluxe version of PowerChute Business Edition. With a normal, non-silent installation it is usually necessary to respond to prompts during the installation. Silent installations do not prompt for input because they already have the answers. Step 1: Creating a Silent Installation Answer File 1. Remove all components of PowerChute from your working computer. 2. Copy the bin\agent folder from the PowerChute CD to a local folder such as C:\agent. 3. Launch a command prompt by selecting the Windows Start button and then Run, and typing command in the box. Click OK. 4. Make sure that a UPS is attached to the machine. 5. At the command prompt, type <agent path>setup.exe -r 5

e.g. C:\agent\setup.exe -r -r records the answers you provide during the installation process. During the installation, select the option to have PowerChute automatically detect the UPS. Then, during the silent installations, the UPS will be detected even if it is on a different port. 6. The installation creates a file named setup.iss (usually in the \System32 folder under your \Windows folder). Search to find it, if necessary. Copy it to the agent folder you created in step 2 above. Step 2: Performing a Silent Installation The silent installation uses the answer file you created in the previous section. 1. Copy the entire agent folder (containing the setup.iss file) to the computer where the silent installation is to be performed. Alternatively, you could copy the folder to a network drive and map to that drive from each installation computer. See an example involving a mapped drive W: below in step 3. 2. Launch a command prompt by selecting the Windows Start button and then Run, and typing command in the box. Click OK. 3. At the command prompt, type <agent path>setup.exe -s e.g. C:\agent\setup.exe -s e.g. W:\agent\setup.exe -s where w is a mapped network drive You can also use the -m argument to log the results in an SMS file whose name is status.mif. e.g. C:\agent\setup.exe -s -m To determine when the silent installation has completed, leave the command prompt window open until the prompt displays again (e.g. C:\agent>). It might take several minutes. 4. Close the command prompt window. 6

Supported UPS Models The Release Notes online help file, Relnotes.chm, typically located in C:\Program Files\APC\PowerChute Business Edition, contains information on the software and hardware requirements for this program. 7

Index A adding UPS systems to your network 5 Agent installing 3 Windows silent installation 5 C Confirm Mode 4 Console installing 5 D Deluxe version 5 G Getting Started 1 I Install button 4 installation procedure 3 upgrading 3 installing the PowerChute Business Edition Agent 3 installing the PowerChute Business Edition Console 5 installing the PowerChute Business Edition Server 4 L Linux 3 N NetWare 3 O overview 1 P PowerChute Business Edition Agent description 2 PowerChute Business Edition Components 2 PowerChute Business Edition Console description 2 PowerChute Business Edition Server description 2 product overview 1 S Server installing 4 silent installation 5 simple-signaling 4 Solaris 3 supported UPS models 2 T Timer Mode 4 U Upgrade button 4 upgrade installation 3 UPS systems adding to network 5 W Windows 3

APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests. www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. www.apc.com/support/ Global support searching APC Knowledge Base and using e-support. Contact an APC Customer Support center by telephone or e-mail. Regional centers: Direct InfraStruXure Customer Support Line APC headquarters U.S., Canada Latin America Europe, Middle East, Africa (1)(877)537-0607 (toll free) (1)(800)800-4272 (toll free) (1)(401)789-5735 (USA) (353)(91)702000 (Ireland) Japan (0) 35434-2021 Australia, New Zealand, South Pacific area (61) (2) 9955 9366 (Australia) Local, country-specific centers: go to www.apc.com/support/contact for contact information. Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support. Entire contents copyright 2005 American Power Conversion. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC, the APC logo, PowerChute, Smart-UPS, and Back-UPS are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only. *990-2289* 990-2289 05/2005