INTRODUCTION. The principles of which are to:



Similar documents
Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

A Complete Solution for Method Linearity in HPLC and UHPLC

A4, Empower3 Processing Tips and Tricks

Earning Customer Loyalty

Evaluating System Suitability CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x

STANDARD OPERATING PROCEDURES

Optimize Your Process Operations by Improving Process Monitoring

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

Empower Software Data Acquisition and Processing

Agilent Television Power Consumption Testing. Application Note

Third Party Instrument Control with Chromeleon Chromatography Data System (CDS) Software

Quick Start Guide Chromeleon 7.2

Image Lab Software for the GS-900 Densitometer

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Fractional Distillation and Gas Chromatography

Agilent Automotive Power Window Regulator Testing. Application Note

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

WATERS QUANTITATIVE ANALYSIS solutions

802.11ac Power Measurement and Timing Analysis

Thermo Scientific SIEVE Software for Differential Expression Analysis

Who We Are. Denis Thiery Chairman and Chief Executive Officer

Uses of Derivative Spectroscopy

The Theory of HPLC. Gradient HPLC

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Signal, Noise, and Detection Limits in Mass Spectrometry

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Using Chromeleon in a Networked Environment

Lawson Talent Management

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

[ Care and Use Manual ]

PCI Express 1.0 (2.5 GT/s) Protocol Test

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

AppsLab Library. A new online platform for Thermo Fisher Scientific applications and methods. Susanne Kramer, Ph.D. Product Manager AppsLab Library

Living up to Life. Leica LAS Live Image Builder Dynamic Software for Fast Widefield Imaging and Extended Depth of Focus

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

Performance 2016: Global Stock Markets

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

Alignment and Preprocessing for Data Analysis

OCTOBER Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology

Lawson Business Intelligence. Solutions for Healthcare

QIAsymphony RGQ Protocol Sheet

Agilent U2000 Series USB Power Sensors

Global Investing 2013 Morningstar. All Rights Reserved. 3/1/2013

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

Corporate Office Von Karman Ave Suite 150 Irvine, California Toll Free: Fax:

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

ELECTRON SPIN RESONANCE Last Revised: July 2007

What is Eluent Generation?

CISCO MDS 9000 FAMILY PERFORMANCE MANAGEMENT

Purchasing Managers Index (PMI ) series are monthly economic surveys of carefully selected companies compiled by Markit.

PXI and AXIe Modular Instrumentation

We decided that we would build IFS Applications on standards so our customers would not be locked into any particular technology. We still do.

1.5 GHz Active Probe TAP1500 Datasheet

Agilent Balanced Measurement Example: Differential Amplifiers

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

einvoice A fully automated digital solution for companies of all sizes

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

Report on Government Information Requests

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

PRODUCT DATA. PULSE WorkFlow Manager Type 7756

Agilent 87421A/87422A Power Supply

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

Thermo Scientific Qtegra Intelligent Scientific Data Solution Software. Delivering quality. Driving productivity

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

10 Reasons to Choose Image-based ID Readers. White Paper

MERCER S COMPENSATION ANALYSIS AND REVIEW SYSTEM AN ONLINE TOOL DESIGNED TO TAKE THE WORK OUT OF YOUR COMPENSATION REVIEW PROCESS

Performance 2015: Global Stock Markets

Direct and Reflected: Understanding the Truth with Y-S 3

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

PXI and AXIe Modular Instrumentation

Background Information

Using Borland Deployment Op-Center to manage CaliberRM, StarTeam, and Mercury TestDirector server environments

NEW LMS 400. The LMS 400 Laser Measurement System Pole position for robotics and material handling. Product Information

White Paper. 10 Reasons to Choose Image-based Barcode Readers

How To Motivate and Retain Key Employees

Report on Government Information Requests

TDS5000B, TDS6000B, TDS/CSA7000B Series Acquisition Modes

ProteinPilot Report for ProteinPilot Software

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

Performance 2013: Global Stock Markets

Pesticide Analysis by Mass Spectrometry

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Global Economic Briefing: Global Inflation

Guidance for Industry

The big pay turnaround: Eurozone recovering, emerging markets falter in 2015

How does a venture capitalist appraise investment opportunities?

The EliA System Time for the essentials Cost efficient and flexible A boost in service for your laboratory and your clinicians

Accuracy counts! SENSORS WITH ANALOG OUTPUT

Lecture 1: The intertemporal approach to the current account

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Application Note # EDS-10 Advanced light element and low energy X-ray analysis of a TiB 2 TiC SiC ceramic material using EDS spectrum imaging

Mass and Resolution Calibration for New Triple-Stage Quadrupole Mass Spectrometers. Rob Grothe Thermo Fisher Scientific, San Jose, CA

Transcription:

Taking the Pain Out of Chromatographic Peak Integration Shaun Quinn, 1 Peter Sauter, 1 Andreas Brunner, 1 Shawn Anderson, 2 Fraser McLeod 1 1 Dionex Corporation, Germering, Germany; 2 Dionex Corporation, Sunnyvale, CA, USA INTRODUCTION Peak detection and integration are fundamental tasks in chromatography, most often done using chromatography software. Enabling software to detect and integrate the peaks as desired (or as required by laboratory rules) is challenging and time-consuming. Common challenges in peak detection include: Distinguishing peaks from noise Correctly identifying the underlying baseline Maintaining correct peak and baseline detection throughout a sequence of chromatograms Correctly handling rider peaks and other unresolved peaks Ideally, these challenges should be addressed using detection parameters so that the same treatment can be applied across multiple chromatograms automatically, thereby minimizing variations introduced by different operators. However, finding parameter combinations that produce the desired results has often been a tedious process, causing many chromatographers to give up and resort to manual integration, which is subjective and labor-intensive. In this presentation we look at a new peak detection algorithm that addresses these issues by separating peak detection from baseline determination. It uses second-derivative signal analysis, providing reliable and consistent peak detection even if the underlying baselineshape changes. An easy to use interface that guides the user through the correct set-up of peak detection parameters is also shown. Examples of how the tools quickly solve problems with real-world chromatograms will be given. Chromeleon 7 Introduces Cobra Cobra is Chromeleon 7 s new peak detection algorithm that in essence simplifies integration for all chromatographers. In designing Chromeleon 7, Dionex introduced the concept of Operational Simplicity TM. The principles of which are to: Minimize the number of steps needed to perform any task Make all steps easy to understand and easy to use Minimize time needed perform any task Cobra is the new algortihm that adheres to these principles providing consistent and reliable peak detection across multiple chromatograms. With the introduction of Cobra, Chromeleon 7 provides the Cobra Wizard; an easy to use interface that guides the user through the correct set-up of peak detection parameters required by Cobra. Define the integration range, specify the smoothing width, and then identify the smallest peak to be integrated. With these settings the Cobra peak detection algorithm instantly integrates the peaks of each chromatogram within a sequence accurately and concisely (Figure 1). In three easy steps Cobra has enough detail to integrate all chromatograms within a sequence. With the new algorithm and assistant, chromatographers can get more accurate, reproducible results much faster and more reliably.

In reality, integration is extremely complex and diverse. Chromatographic data systems have to decipher many different variants and effects such as peaks of varying symmetries, overlapping peaks, valleys, varying sizes of peaks and size ratios, shallow peak rises and declines: extreme fronting or tailing, shifting apexes and valleys of unresolved peaks, baselines with large sloping background absorption and background noise, etc. (Figure 3). 1. Define the integration range. 2. Select the narrowest peak. Cobra is a new peak detection algorithm. It uses advanced signal processing to distinguish true peaks from noise and sophisticated curve fitting techniques to accurately locate peak maxima and inflection points. 3. Select the smallest peak to be integrated. Figure 1. Cobra Wizard. Cobra Peak Detection Algorithm Reliable chromatographic quantification depends upon accurate and reproducible peak integration. Integration of chromatographic peaks determines the area under the peak, the height of the peak and the peak s retention time. This information is used for all subsequent calculations, such as calibration or analysis of unknowns. In simplistic terms, integration involves summing the detector output from peak start to peak end. To achieve this, integration is composed of two distinct events: it is started and then terminated. Peak start and end points define where integration commences and terminates and are identified by significant changes in detector output or by the rate of change of the detector output. Defining peak boundaries however is extremely challenging. In an ideal world chromatographic peaks (Figure 2) would be perfectly symmetrical with pronounced detector signal changes that clearly identify peak start and end. Figure 3. Typical chromatography. Cobra correctly integrates all types of chromatograms using just a few parameters. A fundamental requirement of Cobra is having an optimal number of data points of the order of 10 to 40 to sufficiently characterize the chromatography detection signal of a component peak. Cobra then uses an adaptive Savitsky-Golay smoothing function followed by transformation into a 2nd derivative, assessing the 2nd derivative against automatic thresholds based on signal characteristics. Since the noise is amplified when differences are calculated, Cobra adopts an adaptive Savitsky-Golay smoother to remove the noise without losing valuable information. The second derivative of a chromatographic signal can recognize composite peaks. Assessing the second derivative of a peak also reduces the effects of background and ensures that points of inflection and peak maxima are accurately and consistently identified if the background absorption has lower curvature than the analyte peak. For example, the following two chromatograms show a peak of the same analyte, but one has a large sloping background absorption (Figure 4). The first derivative of these two signals is shown in the center (Figure 5). You can see that the difference between the pure analyte chromatogram (grey) and the chromatogram with interference (blue) is reduced. This effect is considerably enhanced in the second derivative (Figure 6). In this case, the chromatogram of the pure analyte and the chromatogram with interference are almost identical. Figure 2. Idyllic chromatographic peak. 2 Taking the Pain Out of Chromatographic Peak Integration

3.5 1.0 Figure 4. Overlayed chromatograms. 0.50 0.121 0 0.18 620 630 640 650 660 670 678 Figure 7. Local minimum and maximum. Figure 5. First derivative. 7.0 1.28 2.0 0.20 Figure 6. Second derivative. Identifying Peaks In the second derivative of the chromatogram, noise thresholds are automatically determined (as represented by the red dashed lines in Figures 7 and 8 below). The local minimum below the thresholds lower limit is the peak apex. The points of inflection or local maxima above the thresholds are peak start and end (Figure 7). Baseline is interpolated between points where curvature crosses the upper noise threshold limit (Figure 8). 0.1 0.35 209 300 400 500 600 700 730 Figure 8. Baseline interpolation. However, the baseline profile may not be a direct point to point interpolation if more than one peak is eluted on top of it. In a situation with an unresolved peak group, analysts have several choices for determining the location of the chromatogram s baseline profile. The most common options for drawing the baseline between two peaks: drop, valley, tangential skim, exponential skim, and Gaussian skim. 3

SmartPeaks Integration Assistant Chromeleon 7 addresses these issues, providing chromatographers with the simplest of interfaces designed in accordance with Dionex s Operational Simplicity principles. SmartPeaks integration assistant produces desired results quickly and intuitively. The user simply selects a region of the chromatogram and SmartPeaks graphically displays available integration options, such as valley-to-valley baselines or exponential skims (Figure 10). When the user selects an option, SmartPeaks adds the corresponding parameters and values to the processing method so that the desired integration is automatically applied to all chromatograms in the sequence. This process takes just a few seconds eliminating the trial-and-error process of adjusting integration. Figure 9. Baseline Profiles: 1. Drop Perpendicular, 2. Valley to Valley, 3. Tangential Skim, 4. Exponential skim, 5. Gaussian Skim The drop method involves the addition of a vertical line from the valley between the peaks to the horizontal baseline. The vertical line is drawn between the start and stop points of the peak group. The valley method sets start and stop points at the valley between the peaks, thus integrating each peak separately. Skim procedures separate the small peak from the larger parent with separate baselines. The parent peak is integrated from its starting point to the apparent end of the peak group. The small peak s baseline starts at the valley between the peaks and ends when the signal nears the baseline. The area under the skimmed peak is added to the parent peak, not the skimmed peak. This approach has been described also as a tangent integration method and the small peak variously labeled a skim, shoulder, or rider peak. Figure 10: SmartPeaks Several variations of the skim procedure are possible. Tangential draws a straight line from the valley to the end of the peak. Figure 9 shows an exponential skim baseline. An exponential function is used to create curvature in the skim line in an attempt to approximate the underlying baseline of the parent peak. Using an exponential function a curved baseline is drawn under the skimmed peak. Alternatively Gaussian skim tends to more accurately reproduce the Gaussian shape of the parent peak. The complexity and errors increase as resolution decreases, and the valley of unresolved peaks shifts adding to a chromatographer s woes. Understanding these methods and techniques and being able to assign the correct integration parameters are extremely difficult tasks, even for the most experienced chromatographer. 4 Taking the Pain Out of Chromatographic Peak Integration

New Intelligent Parameters Integration is extremely complex and challenging but critical to accurate quantitative analysis. Chromeleon 7 s new detection algorithm Cobra not only simplifies the peak detection and integration process but also provides new adaptable and flexible parameters to assist chromatographers achieve the best results. Minimum Relative Area is one such parameter. Minimum Relative Area rejects peaks, if their minimum area is below a given threshold. The minimum area is measured, on a first pass basis, relative to the sum of all peaks (total area) in a chromatogram. Conclusion Chromeleon 7 is a next generation chromatography data system that delivers intelligent functionality while maintaining operational simplicity. Critical data analysis is achieved accurately and reliably using powerful features of Cobra. The Cobra Wizard and SmartPeaks integration assistant aid and guide the chromatographer to perform the required data manipulations quickly, easily and reproducibly. Using Chromeleon 7, laboratories gain a significant boost in overall efficiency and productivity. Chromeleon 7 is Simply Intelligent. An example of its use is for an analytical method that generates a chromatogram with peaks of interest and other smaller non-related peaks. The requirement is to total the peak response throughout a chromatogram. Typically to ensure that the smaller unwanted peaks are not included the minimum area detection parameter is set to exclude non-related peaks from being integrated. However within a sequence the analyte concentration can vary and the main analyte peaks may drop below the prescribed minimum area threshold. Using the Minimum Relative Area parameter peaks of interest that drop below the prescribed mimimum area will still be detected and integrated because they are greater than the minimum threshold of the current chromatograms total area (Figure 11). Minimum Relative Area Figure 11. Minimum Relative Area. Even though area of main peak drops below level of non-detected peaks in previous chromatogram, the main peak is still integrated. Chromeleon is a registered trademark and Operational Simplicity, Cobra, and SmartPeaks are trademarks of Dionex Corporation. Passion. Power. Productivity. Dionex Corporation North America Europe Asia Pacific 1228 Titan Way P.O. Box 3603 U.S./Canada (847) 295-7500 Austria (43) 1 616 51 25 Benelux (31) 20 683 9768; (32) 3 353 4294 Denmark (45) 36 36 90 90 France (33) 1 39 30 01 10 Germany (49) 6126 991 0 Sunnyvale, CA South America Ireland (353) 1 644 0064 Italy (39) 02 51 62 1267 Sweden (46) 8 473 3380 94088-3603 Brazil (55) 11 3731 5140 Switzerland (41) 62 205 9966 United Kingdom (44) 1276 691722 (408) 737-0700 www.dionex.com Australia (61) 2 9420 5233 China (852) 2428 3282 India (91) 22 2764 2735 Japan (81) 6 6885 1213 Korea (82) 2 2653 2580 Singapore (65) 6289 1190 Taiwan (886) 2 8751 6655 LPN 2297-01 06/09 2009 Dionex Corporation