A-4000 Oil Indicator



Similar documents
T and T Single Input Receiver-Controllers Installation and Calibration

MP8000 Series Pneumatic Valve Actuators

T-4000 Series Room Thermostat Adjusting Instructions*

Model 43AP Pneumatic Controller, Style B

V47 Series Temperature Actuated Modulating Water Valves

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Your safety and the safety of others are very important.

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Installing a Probe. Typical Installation

Model 2128 AIR COMPRESSOR PUMP Operating Instructions

Instructions For SF 6 Refill Kit

Product/Technical Bulletin

NITROUS TRANSFER PUMP INSTRUCTIONS

POWERS CONTROL RC 195 Single Input Receiver-Controller

REAL CHAMBERS CORPORATION SQL PRE-INSTALLATION/ SITE PREPARATION MANUAL

Powers Controls TH 192 S Single Temperature Room Thermostat

Compressor Service & Maintenance Manual

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

TE-6300P Series Temperature Sensors

Recharge Procedure for Telemark TVP-2000 and TVP-3500

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Watts Pure Water Systems

SureSite Magnetic Liquid Level Indicator

L /96. Haldex INSTALLATION INSTRUCTIONS HALDEX PURE AIR PLUS EXTENDED PURGE KIT (DQ6027) HEAVY DUTY CANISTER KIT (DQ6028)

INSTALLATION MANUAL MODEL RP-100

P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

A99B Series Temperature Sensors

PC1131 Electric Air Compressor

Water Pump Replacement

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

RC 195 Multiple Input Receiver-Controller

Installation S19-220PT S19-220BPT. Wall-Mounted Eyewash with Plastic Bowl. Wall-Mounted Eyewash with Stainless Steel Bowl.

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

TYPE E Main Valve Sizes 3 /8 through 12

PC1130 Electric Air Compressor

INSTALLATION MANUAL MODEL RP-150

Dryaire Desiccant System

Rexroth Hydraulic Pump A10VO Series User Manual

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Owner s Manual & Safety Instructions

Operation & Maintenance Manual

MODEL G300 BRAKE BLEEDER

WIKA INSTRUMENT CORPORATION

Operation and Service Guide: Showers

T-4000 Series Pneumatic Room Thermostats

MP-4V Heavy Duty Riveter / 39048

Easy Tool Retracting System CMC-SR2159ER36

Fisher 377 Trip Valve

for DS3 R3 USER HANDBOOK

2740 Whitten Rd Bldg 103 Memphis, TN Telephone

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

ALERT SERVICE BULLETIN December 2012 ENGINE FIRE EXTINGUISHER BOTTLE STEM INSPECTION

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

This equipment has been certified by ITS/ETL to meet or excees SAE J1990 and J1991 for AR512 series and SAE J2099 and J2210 for AR500 series

Model 41 Nullmatic Pressure Regulators

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear

AMX300 DirectConnect Mixing Valve Kits

The Unique Accelabar Flow Meter

Air Eliminators and Combination Air Eliminators Strainers

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)

1000-LB. TRAILER JACK OWNER S MANUAL

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

SLP 1.85 Ratio Offset Rocker Arms with Valve Springs, LS3

FLUSHOMETER - TANK SYSTEM

Your safety and the safety of others are very important.

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

H Service Data Sheet 1 of 8

Subject: 2005 Air Conditioning Service Guidelines

NUMBER: 08 DD15-10 S.M. REF.: 3.2 ENGINE: DD15 DATE: September 2008

OWNER S MANUAL. FOOTWORKS tm Faucet Controller. Foot Operated Faucet Control Valves for Commercial Sinks

Compressed Air Filters

2006 HEADSHOK Service Video #1

PREPIPED LIQUID FUEL MANIFOLDS PLPM

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Installation Instructions S

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

HYDROFOK (Cable & Tube Blowing Machine with Hydraulic Power Unit)

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

STEERING SYSTEM - POWER

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Thermostatic valve Type AVTA

Type 119 Control Valve

A High Bill Usually Means a Leak

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

General Purpose ph/orp Sensors

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

Reasons for reissue of this instruction sheet are provided in Section 5, REVISION SUMMARY.

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

Element D Services Plumbing

Flat Bottom Long Ram Hydraulic Jack

Transcription:

64-272- 0, Rev. B Product Bulletin A-4000 Issue Date 0316 A-4000 Oil Indicator The A-4000 Oil indicator is a calibrated measuring instrument used to detect aerosol-mist levels of oil entrainment that may be present in compressed air systems. Sensitivity of the indicator is limited only by the total number of hours it is allowed to remain on the air supply system. The indictor is sensitive enough to measure a concentration of oil entrainment as low as.01 PPM (.012 mg/m 3 ) in a compressed air system. It can be used in systems with line pressures between 10 and 125 PSIG (70 and 875 kpa). Application Oil entrainment in the control air supply to the pressure reducing valve may eventually have an adverse effect on the control system performance. Since some oil entrainment is inherent to lubricated compressors, all oil lubricated compressor installations must include factory approved oil filters to be reliably acceptable. The indicator can be used in two ways. Either it can be used to check for oil carryover from the compressor or it can be used to check out any filtered air supply source before connecting it to the system and also every few months after the system becomes operative. Once the needle valve of the oil indicator has been opened, one continuous uninterrupted exposure is recommended for greatest accuracy. Operation When the needle valve of the oil indicator is open, less than 2 SCIM/PSIG (.08 ml/s/kpa) will flow through the calibrated plastic tube. Any oil present in the air will then carry a red oil soluble dye up the tube, coloring a white material in the tube. The rate of color travel will be proportional to the amount of oil present. The parts per million (PPM) value of oil entrained in the air can be determined using the conversion chart included with the instrument. After use, the needle valve should be closed and left in the line and the cartridge removed. At the time of the next test, a replacement cartridge will need to be installed on the needle valve fitting. Specifications Fig. 1: A-4000 Oil Indicator Installed in Air Line 2016 Johnson Controls, Inc. 1 Part No. 64-272-0, Rev. B Code No. LIT-718070

Installation In order for the oil indicator to properly measure a given oil entrainment, sufficient exposure time is required. The length of exposure time is inversely proportional to the pressure at the point of installation. When using the indicator to check for oil carryover from the compressor, it should be installed at the discharge of the tank. When using the indicator to measure oil entrainment in the air supply system, it should be installed between the oil filter and the pressure reducing valve (PRV). At this point, dry high pressure air will be present, resulting in the best accuracy and fastest indication. Note: In humid air, moisture may wash traces of dye up the tube, creating a light pink area above the dark red area. When calculating oil entrainment, measure only to the top of the dark red column. Locations involving excessive moisture, temperature, or velocity should be avoided. The indicator valve should remain closed except during the measuring period. For pressures above 125 PSIG (875 kpa) or below 10 PSIG (70 kpa), consult the factory.! WARNING: If the pressure exceeds 125 PSIG or the retaining nut is loosened, the oil indicator tube could blow out of the compression fitting, creating a hazardous condition. The indicator must be mounted within 45 of an upright position for best possible performance. Fittings (1/8 in N.P.T.) are provided on both high and low pressure sides of all A-4000 series filter and reducing station assemblies. Any other mounting location will require a 1/8 in. N.P.T. mounting tee as shown in Fig. 1. Before installing a replacement cartridge, first check that the needle valve on the existing installation is closed all the way by making sure that the needle valve handle (see Fig. 2) is fully rotated in a clockwise direction. Install the replacement cartridge (see Fig. 3) by tightening the lower 1/8 in. nut in place. Note: Do not disturb the factory adjusted torque on the upper 3/16 in. retaining nut that holds the plastic tube in place. Also make sure that the indicator scale can be conveniently viewed before tightening the cartridge in place. Readings and Measurements 1. Before taking a measurement, fill out the record tag furnished with the oil indicator. Record the line pressure or the average pressure (if it varies at the point of installation). 2. Fully rotate the needle valve handle (see Fig. 2) counterclockwise to open it and record the time that the needle valve was opened on the record tag. Slide the record tag over the oil indicator to avoid misplacing it. 3. At the following times and locations, visual inspections of the oil indicators should be made: A. When checking for compressor oil carryover, inspection should be made after 4 hours at the compressor discharge. B. When checking for oil entrainment in the air supply, inspection should be made after 40 hours between the oil filter and the PRV. 4. Judging from the rate of color travel established at the time of the first inspection, schedule the final reading of the indicator (and needle valve shut-off) at approximately 1 unit (marked "1.0" on the scale), and preferably not more than 1-1/2 units (marked "1.5" on the scale). 5. Close the needle valve, remove the oil indicator cartridge, and record the time. Leave the needle valve in the air line for future testing purposes. 6. Record the units of color travel (as read from the indicator scale) and the total time in hours. Fig. 2: Dimensions in./mm 2 A-4000 Product Bulletin

Fig. 3: A-4000-121 Replacement Cartridge Oil Concentration Determination (See Fig. 4) 1. If color travel is 1 unit at the final reading time, find the Total Hours on the right side of the conversion chart and the Pressure on the bottom of the chart. The point where Hours and Pressure intersect is the parts per million of oil concentration. 2. If the final reading occurs at other than 1 unit of color travel, divide the units traveled by the total hours to find the Rate of Color Travel. 3. Find the Rate of Color Travel on the left side of the conversion chart and the Pressure on the bottom of the chart. The point where Rate and Pressure intersect is the parts per million of oil concentration. For any Rate of Color Travel beyond 0.24 units/hr., the measured rate should be divided by any factor which will bring it into the range of the chart. This number should then be used to determine the oil concentration (PPM). This concentration must then be multiplied by the same factor used previously to determine the actual oil concentration. Example: The Rate of Travel on the high pressure side of a PRV (80 PSIG [560 kpa]) is found to be 0.5 units/hr. Divide this rate by five (0.5 5 = 0.1 units/hr) to bring it into the range of the conversion chart. Locate this new rate on the chart, showing a concentration of 1.4 PPM. Multiply this concentration by the previous factor (1.4 5 = 7.0 PPM) to obtain the actual oil concentration in the air being tested. A-4000 Product Bulletin 3

European Single Point of Contact: NA/SA Single Point of Contact: APAC Single Point of Contact: WESTENDHOF 3 45143 ESSEN GERMANY 507 E MICHIGAN ST MILWAUKEE WI 53202 USA C/O CONTROLS PRODUCT MANAGEMENT NO. 22 BLOCK D NEW DISTRICT WUXI JIANGSU PROVINCE 214142 CHINA 4 A-4000 Product Bulletin

Notes Controls Group 507 E. Michigan Street P.O. Box 423 Milwaukee, WI 53202 Printed in U.S.A. A-4000 Product Bulletin 5