VC series BALANCED HYDRONIC VALVES 2 -WAY AND 3 -WAY



Similar documents
XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VU53S; VU54S; VU443A; VU444A; VU843A; VU844A Fan Coil Valves and Actuators

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

AMX300 DirectConnect Mixing Valve Kits

3/2-way Solenoid Valve, direct-acting, NC or NO

Automatic control equipment for HVAC systems

PRESSURE REDUCING CONTROL VALVE

! WARNING. Before using product, read and understand instructions.

T7079A,B Solid State Remote Temperature Controllers

Series 71, 72, and 76 Modutrol IV Motors

Assisted lift operated 2/2-way solenoid valves Type EV250B

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

STC 3S A Series Solenoid Valves

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Butterfly Valves PN 6/10/16 for flanged connection

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Operators manual Basic water heater

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Submersion/Insertion Toroidal Sensor

Oil and Coolant Circulating Heating System. Model - OCSM

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

V47 Series Temperature Actuated Modulating Water Valves

HERZ-Thermal Actuators

VOYAGER 570G. 744A Sprayer Control

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

Cable Plug acc. to DIN EN , Form A

Powers Controls TH 192 S Single Temperature Room Thermostat

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Cooling system components, removing and installing

Stainless Steel Single and Dual Circulation Kits

stainless steel pre-assembled manifolds

T7560A,B,C Digital Wall Module

System 8. ü ( System 8

Unit 24: Applications of Pneumatics and Hydraulics

Model SETR-50 and SETR-51 Trim Tab Control

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

A99B Series Temperature Sensors

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

POWERS Controls No. 4 Pneumatic Damper Actuator

Line to Refrigerator Ice/Water Dispenser

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Cooling system components, removing and installing

3 Port Solenoid Valve

Series Hose Reels

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

V94 BULK TAPE DEGAUSSER

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Why and How we Use Capacity Control

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

UV100A Ultraviolet Air Treatment System

Transformer oil cooler ALFA A02

Drayton Digistat +2RF/+3RF

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Data sheet ECC 12 and 22

Select Radiators Installation Guide

Proportional pressure regulators VPPE

MP8000 Series Pneumatic Valve Actuators

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

Single sub-base valve

Working Pressure - Hose Ends

IMPORTANT DOCUMENTATION DO NOT DISCARD!

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Electric Rotary Actuator - On/Off or programmable control actuator

Digital inductive conductivity transmitter

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Permanent Magnet Motor Kit, Magnetic Reed Type. (SKY-ReedMotorKit) Instructions

Utility Distribution Systems

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Model 43AP Pneumatic Controller, Style B

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

NITROUS TRANSFER PUMP INSTRUCTIONS

STABITHERM INSTALLATION & SERVICE BOOKLET

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Installation Instructions

Transcription:

VC series BALANCED HYDRONIC VALVES 2 -WAY AND 3 -WAY APPLICATION PRODUCT HANDBOOK The VC series balanced hydronic valves allow greater control of hot and/or cold water flow. The VC series balanced hydronic valves are designed for both domestic boiler heating and domestic cooling applications. Subject to change without notice. Printed in the Netherlands. Contents General page Description 2 Series overview 3 Technical Construction and operation 4 Specifications 6 Dimensions 8 Valve selection chart 9 Installation and operation Installation data 10 Adjustment and service data 12 Various Quality assurance statement 13 Approvals and standards 14 Ordering information 15 Standard product examples 16 Fitting for 1/2 and 15 mm valves 17 Fitting for 3/4 and 22 mm valves 19 Fitting for 1 and 28 mm valves 20 Accessories 21 EN2R--9011 0108R2--NE

DESCRIPTION The VC series 2--position hydronic valves are used in domestic and small commercial applications to control the flow of hot and/or cold water. They consist of an actuator, valve and a cartridge assembly. 2--way valves are designed for ON--OFF zone control of domestic systems. 3--way valves can be piped for either diverting or mixing valve applications in domestic central heating and/or cooling systems. Both versions can be used to control individual fan coil, baseboard radiator or convector applications. Depending on the model selected they can be controlled by a low or line voltage SPST or SPDT controller, such as a room thermostat, aquastat or flow switch. The VC series hydronic valves are designed to take avantage of sinusoidal valve actuator travel and therefore operate silently and without water hammer. Through internal logic the actuator only takes power while driving the valve to the commanded position. The actuator head is removable without affecting the integrity of the water system. All actuator versions are interchangeable with any valve body, offering the highest flexibility for boiler production line assembly and maintenance. The valve piston construction allows for port sealing that is independent of the differential pressure across the valve. Flow through the 2--way valve can be in either direction, so the ports are not designated. 3--way valves are suitable for both diverting water from AB to A or to B and from A or B to AB. 2 EN2R -9011 0108R2 -NE

FEATURES 2--way or 3--way body Wide variety of pipe connections including: ISO 7--1 (BSP. Pl) BSP.T NPT Sweat Compression Flare Control by a low or line voltage SPST or SPDT control 24 Vac, 100... 130 Vac or 200... 240 Vac actuators available SPDT auxiliary switch available Quick connect electrical connections or 1000 mm leads Minimal actuator power consumption Double insulated actuator Pressure differential up to 4 bar 1... 95 _C fluid temperature 0... 65 _C ambient temperature Quick and easy replacement of moving parts Actuator head installation does not require draining of the system. 3 EN2R -9011 0108R2 -NE

CONSTRUCTION AND OPERATION All moving and sealing parts of the valve are constructed in the cartridge assembly. The ports are sealed with O --rings on the outer surface of the piston. When the valve stem is driven down to open port A the water will flow through the hollow piston to the other port. In case of a 3--way valve with the piston driven down port B is sealed, allowing flow between port AB and port A. With the stem up the flow is between port AB and port B. The VC series hydronic valves offer a variety of versions of pipe connections to suit the different applications. The valve pressure loss characteristic is dependent on the pipe connection/dimensions For the actual valve rating please refer to the specification section. Fig. 1. When the valve reaches the fully open position the cam closes switch SW 1 and opens the switch SW 2. When the need for heat is satified, the controller contacts open, RLY1 is de--energized and the valve motor driven through SW 1 and the NC contacts of SW 3. When the valve reaches fully closed position, the cam closes SW 2 and opens SW 1. The valve is ready for the next call for heat. For both types of actuator a power failure will leave the valve at the position it was interrupted. When power is restored, the valve will respond to controller demand. 3- way diverter valve 3- way diverter valve with an SPDT (3- wire) actuator On a call for heat, the NO controller contacts close, the valve closes port B and opens port A. When port A is in the fully open position, the cam closes limit switch SW 1 and opens limit switch SW 2. When the need for heat is satisfied the NC controller contacts close, energizing the valve through SW 1 causing port A to close. When port A is fully closed the cam closes SW 2 and opens SW 1. The valve is ready for the next call for heat. 3- way diverter valve with an SPST (2- wire and common) actuator On a call for heat, the controller contacts close, RLY 1 is energized making the NO contacts in switch SW 3, causing port B to close and port A to open. When port A reaches the fully open position the cam closes switch SW 1 and opens the switch SW 2. When the need for heat is satified, the controller contacts open. RLY 1 is de--energized making the NC contacts in SW 3 and port A is driven closed through SW1 and the NC contacts of SW 3. When port A is in the fully closed position, the cam closes SW 2 and opens SW 1. The valve is ready for the next call for heat. 2- way valve Fig. 2. For both types of actuator a power failure will leave the valve at the position it was when interrupted. When power is restored, the valve will respond to controller demand. 2- way valve with an SPDT (3- wire) actuator On a call for heat, the NO controller contacts close and the valve opens. When the valve is fully open, the cam closes switch SW 1 and opens switch SW 2. When the need for heat is satisfied the NC controller contacts close, energizing the valve through SW 1 and closing the valve. When the valve is fully closed the cam closes SW 2 and opens SW 1. The valve is ready for the next call for heat. 2- way valve with an SPST (2- wire and common) actuator On a call for heat, the controller contacts close, RLY 1 is energized making the NO contacts in switch SW 3 causing the valve to open. Wiring Fig. 3. and 4. show wiring connections for SPDT and SPST controllers on either 2--way valves or 3--way valves. Port A open and closed denotes valve open and closed for 2--way, and AB--B open and AB--B open for 3--way valves respectively. Ona2--wayvalve: Port A open denotes valve open Ona3--wayvalve: Port A open denotes flow through AB--A Port A closed denotes flow through AB--B For mixed low/line voltage, the cable assembly version recommended. 4 EN2R -9011 0108R2 -NE

Fig. 3. Logic sequence diagram with 3 wire actuator for SPDT controller Fig. 4. Logic sequence diagram with 2 wire + common actuator for SPST controller 5 EN2R -9011 0108R2 -NE

SPECIFICATIONS Voltage 24 V, 50/60 Hz Blue 100... 130 V, 50/60 Hz Black 200... 240 V, 50/60 Hz Red Colour -coded label Power consumption 6 Watt maximum at nominal voltages (during valve position change only) 6 VA for transformer and wiring Maximum power time: 15% Endswitchrating 2.2 A inductive from 5... 120 Vac 1.0 A inductive above 120... 277 Vac Minimum dc switching capbility: 0.05A 24 Vdc Nominal timing Valve opens in 6 seconds @ 60 Hz (20% longer @ 50 Hz) Electrical termination Molex TM (header# 39--30--1060) Requires mating connector receptacle/housing # 39--01--2060 Contacts: Mini--Fit 5556 series With integral 1000 mm (39 ) leadwire cable Pipe fitting sizes Seetable1. Fig. 5. 3 -way valve diverting flow characteristic at constant pressure on port AB Table1.Pipefittingsizes Pipe fitting sizes 3/8 1/2 3/4 1 15 mm 22 mm 28 mm Note: N -- not threaded Flare E E -- -- -- -- -- I -- internally threaded E--externally threaded Inverted flare -- I -- -- -- -- -- Sweat -- N N N -- -- -- BSPP -- I E, I E, I -- -- -- BSPT -- I I -- -- -- -- NPT -- -- I I -- -- -- Compression fitting -- -- -- -- I E E Terminal Action Wire colour 1 Com* Orange 2 Neutral Blue 3 Closed** Brown 4 NO* Grey 5 NC* White 6 Open** Black * Terminals 1, 4 and 5 are only connected if an auxiliary switch is used. NO, NC refers to port A closed position ** Refers to port A (closed or open) NOTE: For mixed voltages (low/line voltage) thecableassemblyversionis recommended Molex TM version Lead wire cable Fig. 6. Wiring terminal colour coding 6 EN2R -9011 0108R2 -NE

Table 2. Wiring connections and valve movements Actuator type Connections 2 -way valve Cable model Molex TM movement model 3--wire (for SPDT controller) 2--wire + common (for SPST controller) Blue & brown energized Black de--energized Blue & black energized Brown de--energized Blue & brown energized Brown and black open Blue & brown energized Brown and black closed Pin #2 & 3 energized Pin #6 de --energized Pin #2 & 6 energized Pin #3 de --energized Pin #2 & 3 energized Pin #3 and 6 open Pin #2 & 3 energized Pin#3and6closed Closes Opens Closes Opens 3 -way valve movement A port closes B port closes A port closes B port closes Ambient temperature 0... 65 _C 10 Fluid temperature 1... 95 _C (120 _C short duration peak) Kv 6,0 Shipping storage temperature --40... 65 _C Pressure rating Static: 20 bar Burst: 100 bar Maximum operating pressure differential 4 bar Flow rate (m 3 /h) 1 Kv 5,0 Kv 5,3 Kv 3,0 Kv 2,1 Flow rating Dependent upon body configuration (see fig. 5., 7. and 8.) Flow rate Q m 3 /h to be calculated as: Q = Kv p(bar) Pressure loss αp (bar)tobecalculatedas: 0,1 bar 0,001 0,01 0,1 kpa 0,1 1 10 Pressure loss Fig. 7. Valve pressure loss characteristic for 2 -way valves 10 p = Q Kv 2 Flow 2-way Flow can be in either direction Valve is closed without the actuator mounted 3-way Flow can be diverting (AB to A or B) or mixing (A or B to AB). Port A is closed without the actuator mounted Flow rate (m 3 /h) 1 Kv 6,4 Kv 7,0 Kv 3,4 Kv 7,7 Kv 2,6 Valve material Body: bronze Cartridge: Ryton TM (polyphenylene sulphide) Noryl TM (polyphenylene oxide) O --ring seals: EPDM rubber Stem: stainless steel Actuator cover: Noryl TM (94V--0) Actuator base: Ryton TM (94V--0) 0,1 bar kpa 0,001 0,01 0,1 0,1 1 10 Pressure loss Fig. 8. Valve pressure loss characteristic for 3 -way valves 7 EN2R -9011 0108R2 -NE

DIMENSIONS (NOMINAL) Pipe fitting 2 -way valve 3 -way valve Dim. C mm Dim. D mm Nom. flow rating - Kv Dim. C mm Dim. E mm 1 / 2 Sweat 98 111 3.0 98 136 3.6 1 / 2 BSPT (internal thread) 98 111 3.0 98 136 3.4 3 / 8 flare (no adapter) 98 111 2.1 98 136 2,6 1 / 2 flare (no adapter) 98 111 2.9 98 136 3.4 1 / 2 inverted flare (no adapter) 98 111 3.1 98 136 3.6 1 / 2 BSPP/15 mm (internal thread) 98 111 3.0 98 136 3.4 22 mm compression fitting* 112 113 5.3 112 140 7.1 3 / 4 BSPP (external thread) 94 113 5.3 94 130 6.9 3 / 4 BSPP (internal thread) 94 113 5.3 94 130 7.0 3 / 4 BSPT (internal thread) 94 113 5.3 94 130 7.0 3 / 4 NPT (internal thread) 94 113 5.4 94 130 7.4 3 / 4 Sweat 94 113 5.0 94 132 6.4 28 mm compression fitting* 116 113 6.0 116 147 7.7 1 BSPP (internal thread) 94 113 6.0 94 136 7.7 1 BSPP (external thread) 94 113 6.0 94 136 7.7 1 NPT (internal thread) 94 113 6.0 94 136 7.7 1 Sweat 94 113 6.0 94 136 7.7 * Includes compression nuts and olives Nom. flow rating - Kv 2 -way valve 3 -way valve 94 68 94 68 90 90 D E A B AB C C Fig. 9. Valve dimensions 8 EN2R -9011 0108R2 -NE

VALVE SELECTION CHART A ACTUATORS Description Designation Nominal timing @ 50 Hz: 7 seconds 24 V (50... 60 Hz) 3wireforSPDTstat. -- with Molex TM connector 2010 -- with 1000 mm cable 2011 3 wire for SPDT stat.(w/spdt aux. sw.) -- with Molex TM connector 2610 -- with 1000 mm cable 2611 2 wire + com. for SPST stat. -- with Molex TM connector 8010 -- with 1000 mm cable 8011 2 wire + com. for SPST stat. (w/spdt aux. sw) -- with Molex TM connector 8610 -- with 1000 mm cable 8611 100... 130 V (50... 60 Hz) 3wireforSPDTstat. -- with Molex TM connector 6010 -- with 1000 mm cable 6011 3 wire for SPDT stat. (w/spdt aux. sw.) -- with Molex TM connector 6610 -- with 1000 mm cable 6611 2 wire + com. for SPST stat. -- with Molex TM connector 4010 -- with 1000 mm cable 4011 2 wire + com. for SPST stat. (w/spdt aux. sw.) -- with Molex TM connector 4610 -- with 1000 mm cable 4611 200... 240 V (50... 60 Hz) 3wireforSPDTstat. -- with Molex TM connector 6012 -- with 1000 mm cable 6013 3 wire for SPDT stat.(w/spdt aux. sw.) -- with Molex TM connector 6612 -- with 1000 mm cable 6613 2 wire + com. for SPST stat. -- with Molex TM connector 4012 -- with 1000 mm cable 4013 2 wire + com. for SPST stat. (w/spdt aux. sw.) -- with Molex TM connector 4612 -- with 1000 mm cable 4613 B BODY Description Designation C CARTRIDGE Kv Designation 2 -way valves 1 /2 Sweat AA 1 /2 BSPT (internal thread) AB 3 /8 Flare (no adapter) AC 1 /2 Flare (no adapter) AD 1 /2 Inverted Flare (no adapter) AE 1 /2 BSPP (internal thread)* AF 22 mm Compression fitting** AG 3 /4 BSPP (external thread) AH 3 /4 BSPP (internal thread) AJ 3 /4 BSPT (internal thread) AK 3 /4 NPT (internal thread) AL 3 /4 Sweat AM 28 mm Compression fitting** AN 1 BSPP (internal thread) AP 1 BSPP (external thread) AQ 1 NPT (internal AR 1 Sweat AS 1 BSPT (internal thread) AT 3 -way valves 1 /2 Sweat MA 3 /8 Flare (no adapter) MB 1 /2 Flare (no adapter) MC 1 /2 Inverted Flare (no adapter) MD 1 /2 BSPP (internal thread)* ME 22 mm Compression fitting** MF 3 /4 BSPP (external thread) MG 3 /4 BSPP (internal thread) MH 3 /4 BSPT (internal thread) MJ 3 /4 NPT (internal thread) MK 3 /4 Sweat ML 28 mm Compression fitting** MM 1 /2 BSPT (internal thread) MN 1 BSPP (internal thread) MP 1 BSPP (external thread) MQ 1 NPT (internal MR 1 Sweat MS 1 BSPT (internal thread) MT 2 -way valves 3.0 10 3.2 10 2.1 10 2.3 10 3.1 10 3.0 10 5.3 10 5.3 10 5.3 10 5.3 10 5.4 10 5.0 10 6.0 10 6.0 10 6.0 10 6.0 10 6.0 10 6.0 10 3 -way valves 3.6 60 2,6 60 3,4 60 3.6 60 3.4 60 7.1 60 6.9 60 7.0 60 7.0 60 7,4 60 6.4 60 7.7 60 3.4 60 7.7 60 7.7 60 7.7 60 7.7 60 7.7 60 * The valve end fittings are internally machined to accept 15 mm compression fittings. ** Compression fittings included CUSTOMER SPECIAL PACKAGING Description Designation 00 Standard Designation 01... 99 Customer special assigned by Honeywell Unit pack - (10 per overpack) Egg crate (20) E (20 actuators per pack) (10 body/cartidge(s) per pack) Note: Order in multiples of 20 actuators & 20 valves for egg crate pack. Example: A VC 4612 MM 6000 valve has a 200/240 V, 50/60 Hz, 6 second nominal timing actuator (with a SPDT auxiliary switch) for operation by a SPST thermostat suitable for Molex TM connection. The valve has a 3--way body with 28 mm compression fittings rated at 7.7 Kv & 60 psi differential. Shipped in unit pack. 9 EN2R -9011 0101R1 -NE

INSTALLATION IMPORTANT Take care that installer is a trained experienced service person. When installing this product read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. Check the ratings given in the instructions and on the product to make sure it is suitable for your application. Always conduct a thorough checkout after installation. CAUTION Switch off power supply before making electrical connections to prevent electrical shock and equipment damage. It is advisable to remove the actuator head from the valve body for ease of installation. Fit the actuator head in the most convenient position for wiring. On sweat fitted valves, the cartridge is shipped loose or is removed to avoid being damaged during the solder operation. On 24 Volt systems, never short circuit the valve coil terminals as this may burn out the heat anticipator in the thermostat. To remove the actuator head 25 mm clearance is needed above the actuator. Plumbing (see fig. 10.) The valve may be plumbed in any angle but preferably not with the actuator head below the horizontal level of the valve body. Make sure there is enough room around the actuator head for servicing or replacement. When used to form a part of a central heating system, do not locate it where it will block the system vent, cold feed or any bypass when the valve is closed Mount the valve directly in the tube or pipe. Do not grip actuator head while making and thightening plumbing connections. Either hold valve body in your hand or attach adjustable spanner across the hexagonal or flat faces on the valve body. Compression models For compression fitted models, tighten the compression nuts enough to make a watertight seal. Take care not to overtighten. Maximum torque limit is 33 ft--lb for the 22 mm compression fitting and 48 ft--lb for the 28 mm compression fitting. Fig. 10. Plumbing Sweat models On sweat fitted valves, the cartridge is shipped loose to avoid being damaged during the solder operation. Remove valve actuator from body and solder the connecting pipes in accordance with normal soldering practices. After soldering and valve has cooled, remove cartridge assembly from plastic bag, insert into the valve body and tighten down with enclosed wrench until it bottoms out. Do not overtighten (maximum torque is 40 ft--lb). The top surface of the cartridge will be flush with the top edge of the body casting. Replace valve actuator. 10 EN2R -9011 0108R2 -NE

To install a replacement actuator head IMPORTANT Installation of a new actuator head does not require draining the system providing the valve body and cartridge assembly remain in the pipe line. Disconnect power supply before servicing to avoid electrical shock or equipment damage. Disconnect leadwires to actuator head, or depress tabonmolex TM connector and remove. Where appropriate, label wires for rewiring. The actuator head is automatically latched to the valve (see fig. 11.) To remove lift up on the latch mechanism located directly below the red manual open lever. Press the actuator head down towards the valve body with moderate hand force and turn counter--clockwise by 1 / 8 turn (45 degrees) simultaneously. Lift the actuator head off the valve body. NOTE: The actuator can also be installed at right angles to the valve body but in this position the latch mechanism is not engaged. Install the new actuator head by reversing the process. Reconnect leadwires or Molex TM connector. Restore power. Fig. 11. Latch mechanism 11 EN2R -9011 0108R2 -NE

ADJUSTMENT, CHECKOUT AND SERVICE Manual opener The manual opener can be manipulated when in the up position. The motorized valve can be opened by firmly pushing the red manual lever down to midway and in (only possible if the actuator is in the upper position). This holds all ports in the open position and with auxiliary switch models the NO switch is closed. Ports A and B of 3--way valves are opened. This manual open position may be used for filling, venting or draining the system or for opening the valve in case of power failure. The valve can be restored manually to the closed position by depressing the red manual lever ligthly and then pulling it out. The valve actuator returns to the automatic position when power is restored. Checkout Raise the setpoint of the thermostat above room temperature to initiate a call for heat. Valve position indicator should move downward to the open position. For all auxiliary switch models, monitor the control devices. 2--way valve: check that the valve opens, the auxiliary switch (if present) closes and at the end of the opening stroke the circuit to the circulator or another valve is made. 3--way valve: check that port A opens, port B closes, the auxiliary switch (if present) operates and at the end of the opening stroke the circuit to the circulaotr or another valve is made. Lower the set point of the thermostat below room temperature. Observe the control devices. 2--way valve: check that the valve closes and all auxiliary equipment stops. 3--way valve: check that port A closes and all auxiliary equipment stops. Service WARNING The VC series hydronic valves should be serviced by trained, experienced service personnel. If the valve is leaking, drain system or isolate valve from the system. Check to see if the cartridge needs to be replaced. If the gear train of the motor is damaged, replace the actuator assembly. NOTE: The VC series hydronic valves are designed and tested for silent operation in properly designed and installed systems. However, water noises may occur as a result of excessive water velocity. Piping noises may occur in high temperature (over 100 _C) systems with insufficient water pressure. 12 EN2R -9011 0108R2 -NE

QUALITY ASSURANCE STATEMENT The quality system is described in Honeywell Limited s Quality Manual and supporting operational procedures and instructions. The quality system is approved by Quality Management Institute (accredited by the Standards Council of Canada and RvC) against certificate 001082 and is reviewed annually. The quality organisation is responsible for defining, maintaining, improving and verification of the quality systems in the field of design, production process and field quality service. Each production operation has manufacturing instructions containing work procedures, set--up information, quality standards and quality checks. All products are tested prior to shipping. Assembly inspection is conducted by the assembly workers. All inspections (incoming and assembly) are performed by trained personel and according inspection procedures. 13 EN2R -9011 0108R2 -NE

STANDARDS AND APPROVALS Approvals The VC series balanced hydronic valves 200... 240 V and 24 V versions meet the Low Voltage Directive 73/23/EEC (EN 60730--1 and --2 --8) and EMC Directive 89/336/EEC for incorporation in household electrical applications according to EN 60335 series. 14 EN2R -9011 0108R2 -NE

ORDERING INFORMATION Before ordering please determine the following: The body type: 2--way or 3--way. See Valve selection chart page 9 The actuator voltage: 24, 100... 130 or 200... 240 Vac. See Valve selection chart page 9 Thepipefittingsize: to do this first determine the flow rating (Kv) required. Refer to Dimensions page 6 to select the pipe fitting that is applicable. Then, contact your Honeywell account manager who will assist you in determing the order specification number. Order from: Your nearest Honeywell branch office. Your local Honeywell agent or wholesaler. NOTE: Most models of valves and replacement components will be available under TRADELINE label. Ask your wholesaler for details. VC 4013 MG 60 00 E Product family specifier Accessories and packing specifier -- this letter denotes the packaging and accessory configurations for complete devices and merchandised items Actuator specifier -- the first digit denotes a standard Honeywell control circuit series. -- the second, third and fourth digits denote actuator and termination variations Customizing specifier -- expresses variations in a valve configuration which consists of a product family, actuator, body and cartridge -- 00 is standard configuration Body specifier -- a first letter from A to L denotes 2--way operation, whereas M to Z denotes 3--way operation -- the second letter accommodates first letter variations Cartridge specifier -- a number from 10 to 59 denotes 2--way operation, whereas 60 to 99 de notes 3--way operation. Fig. 12. Model number chart 15 EN2R -9011 0108R2 -NE

STANDARD PRODUCT EXAMPLES NOTE: The letter Z denotes the absence of a component VC2010MG 6000 VC2010 actuator packed with a MG6000 body VC2010ZZ 00E Egg crate with 20 actuators type 2010 VC Z MG6000E Egg crate with 10 bodies type MG6000 VC2010ZZ00 Actuator only VC ZZ 6000 Cartridge for 3--way valve Minimum quantity 10 pcs VC ZZ 1000 Cartridge for 2--way valve Minimum quantity 10 pcs 16 EN2R -9011 0108R2 -NE

FITTINGS FOR 1/2 AND 15 MM VALVE FAMILY (COMMONLY USED WITH VC VALVES) 98.0 98.0 A A 46.0 AB B B Fig. 13. Finished dimensions of 1/2 or 15 mm bronze bodies (VC valves) Gasket Metal flange Loose brass nut Pipe has paralel threads Pipe is soldered or threaded into metal flange (solder joint shown) Fig. 14. 1/2 BSPP external (G 1/2 B) Fig. 16. 1/2 BSPP internal (Rp 1/2 ) Loose brass nut Pipe has 45_ flare Loose nut Loose ferrule (compression ring) Fig. 17. 1/2 BSPP internal (Rp 1/2 ) using ferrule & nut for sealing 15 mm outer diameter pipe North America 1/2 pipe (5/8 outer diameter) Fig. 15. 1/2 flare 17 EN2R -9011 0108R2 -NE

Pipe has 45_ flare Loose nut Pipe has 45_ flare Loose nut For North America 3/8 pipe (1/2 outer diameter) Fig. 18. 3/8 flare For North America 1/2 pipe (5/8 outer diameter) Fig. 20. 1/2 inverted flare North America 1/2 pipe sweat fitting Pipe is sweat soldered into valve body Fig. 19. 1/2 Sweat 18 EN2R -9011 0108R2 -NE

FITTINGS FOR 3/4 AND 22 MM VALVE FAMILY (COMMONLY USED WITH VC VALVES) 93.2 93.2 A B A B B 1) AB Fig. 21. Finished dimensions of 3/4 or 22 mm bronze bodies (VC valves) Metal flange Gasket Loose brass nut Pipe has parallel threads 1) B = 39.9 1) B = 39.9 Pipe is soldered or threaded into metal flange (solder joint shown) Fig. 22. 3/4 BSPP external (G 3/4 B) Fig. 24. 3/4 BSPP internal (Rp 3/4) Pipe has tapered threads Loose ferrule (olive) * Loose brass nut * 1) B = 39.9 Fig. 25. 3/4 BSPT internal (Rc 3/4) or NPT internal Pipe is slip fit into valve body Using ferrule and nut for sealing 22 mm outerdiameter pipe. 1) B = 39.9 * Compression nut and olive are supplied with the valve body. Fig. 23. 22 mm compression (external thread) Pipe is sweat soldered into 1) valve body B = 42 North America 3/4 pipe sweat fitting Fig. 26. 3/4 Sweat 19 EN2R -9011 0108R2 -NE

FITTINGS FOR 1 AND 28 MM VALVE FAMILY (COMMONLY USED WITH VC VALVES) 93.2 93.2 45.5 A AB B A B Fig. 27. Finished dimensions of 1 or 28 mm bronze bodies (VC valves) Gasket Metal flange Loose brass nut Pipe has tapered threads Pipe is soldered or threaded into metal flange (solder joint shown) Fig. 28. 1 BSPP external (G 1 B) Fig. 31. 1 BSPT internal (Rc 1) or 1 NPT internal Loose ferrule (olive) * Loose brass nut * Pipe is sweat soldered into valve body Fig. 32. 1 Sweat Pipe is slip fit into valve body Using ferrule and nut for sealing 28 mm outerdiameter pipe. * Compression nut and olive are supplied with the valve body. Fig. 29. 28 mm compression (external thread) Pipe has parallel threads Fig. 30. 1 BSPP internal (Rp 1) 20 EN2R -9011 0108R2 -NE

ACCESSORIES Replacement cartridge (includes change tool) Cartridge for 2- way valve -- order number: VCZZ1000 -- supplied in overpacks of 10 units Cartridge for 3- way valve -- ordernumber: VCZZ6000 -- supplied in overpacks of 10 units Molex TM connector with wires CAUTION Not to be used for line voltage or mixed low/line voltage applications. 3-wire Molex TM connector, length 5 -- ordernumber: 40.007.035-001 6-wire Molex TM connector, length 5 -- ordernumber: 40.007.035-002 3-wire Molex TM connector, length 1000 mm -- ordernumber: 40.007.035-005 Home and Building Control Combustion Controls Center Europe Honeywell BV Phileas Foggstraat 7 7821 AJ Emmen The Netherlands Tel: +31 ( -)591 695911 Fax: +31 ( -)591 695200 http://europe.hbc.honeywell.com 21 EN2R -9011 0108R2 -NE